Protective coatings for atomic oxygen susceptible spacecraft materials - STS-41G results

Sixteen materials consisting of metallizations, silicones, and FEP Teflon were applied as protective coatings to selected spacecraft material surfaces and exposed on STS-41G to the LEO atomic oxygen environment. Evaluations of their protective effectiveness were made through assessing their mass loss/gain characteristics, maintenance of base material optical properties, and imperviousness to atomic oxygen attack. Generally, all coatings provided some degree of protection for the underlying material. In some cases the overcoat appeared to be too thin thereby providing inadequate protection.

Whitaker, A. F.↗

Mass spectrometric studies of the electrical breakdown of thin polymer films

The composition of the neutral particles released during the electrical breakdown of 50-micron and 75-micron insulating films of the type used on spacecraft exteriors investigated experimentally using a time-of-flight mass spectrometer triggered by the breakdown event. The experimental apparatus is described in detail, and the results are presented in photographs. It is found that the particle flux from Teflon FEP and PFA films comprise mainly fluorocarbon fragments, some with mass 350 amu or greater, but the flux from Kapton oxygen-ion-beam treated Kapton, Tefzel, and Mylar comprises mainly molecules of mass 44 amu or less.

Kendall, B. R. F.↗

Coating a Hydrogen-Maser Chamber With CF4

Coating of carbon tetrafluoride formed on interior surface of atomic-hydrogen maser by allowing gas to freeze on surface. New coating enables maser to oscillate down to 26 K; most effective previous coating, fluorinated ethylene/polypropylene (FEP) copolymer allowed oscillation down to about 50 K.

Vessot, Robert F. C.↗

Inflatable-Seal Assembly For Cryogenic Fluids

Connector for cryogenic fluid lines quickly joined or separated, seals tightly, and reduces transfer of heat to fluid. Features redundant sealing rings inflated after joining so they wedge tightly against connector base, preventing leakage. Cylinder of FEP inflatable. Pair of threaded stainless-steel rings - one at each end of cylinder - secure cylinder in quick-disconnect assembly.

Buehler, Kurt↗

The NASA atomic oxygen effects test program

The NASA Atomic Oxygen Effects Test Program was established to compare the low earth orbital simulation characteristics of existing atomic oxygen test facilities and utilize the collective data from a multitude of simulation facilities to promote understanding of mechanisms and erosion yield dependence upon energy, flux, metastables, charge, and environmental species. Four materials chosen for this evaluation include Kapton HN polyimide, FEP Teflon, polyethylene, and graphite single crystals. The conditions and results of atomic oxygen exposure of these materials is reported by the participating organizations and then assembled to identify degrees of dependency of erosion yields that may not be observable from any single atomic oxygen low earth orbital simulation facility. To date, the program includes 30 test facilities. Characteristics of the participating test facilities and results to date are reported.

Banks, Bruce A.↗

ESCA study of several fluorocarbon polymers exposed to atomic oxygen in low earth orbit or within or downstream from a radio-frequency oxygen plasma

The ESCA (electron spectroscopy for chemical analysis) spectra of films of Tedlar, tetrafluoroethylene-hexafluoropropylene copolymer (in the form of a Teflon FEP coating on Kapton H, i.e., Kapton F), and polytetrafluoroethylene (Teflon or Teflon TFE), exposed to atomic oxygen O(3P) either in LEO on the STS-8 Space Shuttle or within or downstream from a radio-frequency oxygen plasma, were compared. The major difference in surface chemistry of Tedlar induced by the various exposures to O(3P) was a much larger uptake of oxygen when etched either in or out of the glow of an O2 plasma than when etched in LEO. In contrast, Kapton F exhibited very little surface oxidation during any of the three different exposures to O(3P), while Teflon was scarcely oxidized.

Golub, Morton A.↗

Vacuum ultraviolet radiation/atomic oxygen synergism in materials reactivity

Experimental results are presented which indicate that low fluxes of vacuum UV (VUV) radiation exert a pronounced influence on the atomic oxygen reactivity of such fluorocarbon and fluorocarbon spacecraft materials as the FEP Teflon and PCTFE that are under consideration for the Space Station Freedom. With simultaneous exposure to VUV fluxes comparable to those experienced in LEO, the reactivity of these materials becomes comparable to that of Kapton; VUV radiation has also been shown to increase the reactivity of Kapton with thermal-energy oxygen atoms.

Koontz, Steven↗

Low-Wear Ball-Bearing Separator

Proposed ball-bearing separator for use in cryogenic pump stronger and more resistant to wear. Consists of molded plastic-and-metal composite ring imbued with solid lubricant and containing embedded metal ring. Obtains combination of strength and lubricity. Before molding and machining, ring includes tooling portion for handling and indexing. Molded composite blend of PTFE and fluorinated ethylene/propylene (FEP) filled with brass and bronze powder and molybdenum disulfide powder.

Hawkinson, Elden L.↗

LDEF contaminants analysis data

Modification of surface texture for Ram Facing FEP Teflon on the Long Duration Exposure Facility (LDEF) satellite is documented. Photos of changes in surface texture if thermal blanket material with position on tray C-08 are presented. Infrared spectra and photographic documentation of molecular film deposits on LDEF surfaces by location is reported. Results of a survey of the functional groups and elemental composition of the brown film found widely distributed on the surface of LDEF is shown. A partial photographic catalog of LDEF particulate contaminants is included. A set of photos of particles collected or photographed in place on the surface of LDEF is shown. Particle counts and surface obscuration data for the LDEF satellite are reported. The surface data in tables and charts is presented for the LDEF satellite by location.

Crutcher, E. Russ↗

Effects of LDEF flight exposure on selected polymeric films and thermal control coatings

The characterization of polymeric films and thermal control coatings which were exposed for five years and ten months to the low-Earth environment is reported. Changes in solar absorptance, thermal emittance, and transmission are compared to laboratory control specimens. Sputter-deposited metallic coatings are shown to eliminate atomic oxygen erosion of resin matrix composite materials. The effects of long-term atomic oxygen exposure to metallized FEP Teflon film is characterized. Chemical characterization of polymeric films indicates that although surface erosion occurs, the molecular structure of the basic polymeric film has not changed significantly in response to this exposure.

Slemp, Wayne S.↗

Chemical characterization of selected LDEF polymeric materials

The chemical characterization of selected polymeric materials which received exposure on the LDEF is reported. The specimens examined include silvered fluorinated ethylene propylene (FEP) teflon thermal blanket material, polysulfone matrix resin/graphite fiber reinforced composites, and several high performance polymer films. These specimens came from numerous LDEF locations and, thus, received different environmental exposures. The results of infrared, thermal, x ray photoelectron, and various solution property analyses have shown no significant change at the molecular level in the polymer that survived exposure. However, scanning electron and scanning tunneling microscopies show resin loss and a texturing of the surface of some specimens which resulted in a change in optical properties. The potential effect of a silicon containing molecular contamination on these materials is addressed. The possibility of continued post-exposure degradation of some polymeric films is also proposed.

Young, Philip R.↗

Space environmental effects on silvered Teflon thermal control surfaces

Cumulative space environmental effects on silver/fluorinated ethylene propylene (Ag/FEP) were a function of exposure orientation. Samples from nineteen silvered Teflon (Ag/FEP) thermal control surfaces recovered from the Long Duration Exposure Facility (LDEF) were analyzed to determine changes in this material as a function of position on the spacecraft. Although solar absorptance and infrared emittance of measured thermal blanket specimens are relatively unchanged from control specimen values, significant changes in surface morphology, composition, and chemistry were observed. We hypothesize that the FEP surfaces on the LDEF are degraded by UV radiation at all orientations, but that the damaged material has been removed by erosion from the blankets exposed to atomic oxygen flux and that contamination is masking the damage in some areas on the trays flanking the trailing edge.

Hemminger, C. S.↗

LDEF materials data analysis: Representative examples

Results of measurements on silverized teflon, heat shrink tubing and nylon tie downs on the wire harness clamps, silvered hex nuts, and contamination deposits are presented. We interpret the results in terms of our microenvironments exposure model and locations on the Long Duration Exposure Facility (LDEF). Distinct changes in the surface properties of FEP were observed as a function of UV exposure. Significant differences in outgassing characteristics were detected for hardware on the interior row 3 relative to identical hardware on the interior row 3 relative to identical hardware on nearby rows. The implications for in service performance are reviewed.

Pippin, H. Gary↗

LDEF thermal control coatings post-flight analysis

The optical, physical, and chemical properties of selected spacecraft thermal control coatings, exposed for 10 months and 5.8 years on the leading edge (Row 9) of the LDEF, are reported. The following coatings were used: quartz/silver optical solar reflector; silvered FEP Teflon; S-13GLO, YB-71, and A-276 white paints; black paint; and sputter deposited coatings over graphite-epoxy composite substrates. The solar absorptance, total normal emittance, scanning electron and X-ray photoelectron microscopy, and X-ray diffraction analyses will be compared for the control, the 10 month exposed, and the 5.8 year exposed specimens. Data suggests that the high atomic flux over the last 6 months of the LDEF mission may have influenced the results from from this coatings experiment.

Slemp, Wayne S.↗

Radiation-induced insulator discharge pulses in the CRRES Internal Discharge Monitor satellite experiment

The Internal Discharge Monitor (IDM) is designed to observe electrical pulses from common electrical insulators in space service. The IDM is flying on the Combined Release and Radiation Effects Satellite (CRRES). The sixteen insulator samples include G10 circuit boards, FR4 and PTFE fiberglass circuit boards, FEP Teflon, alumina, and wires with common insulations. The samples are fully enclosed, mutually isolated, and space radiation penetrates 0.02 cm of aluminum before striking the samples. The IDM results indicate the rate at which insulator pulses occur. Pulsing began on the seventh orbit. The maximum pulse rate occurred near orbit 600 when over 50 pulses occurred. The average pulse rate is approximately two per orbit, but nearly half of the first 600 orbits experienced no pulses. The pulse rate per unit flux of high energy electrons has not changed dramatically over the first ten months in space. These pulse rates are in agreement with laboratory experience on shorter time scales. Several of the samples have never pulsed. IDM pulses are the seeds of larger satellite electrical anomalies. The pulse rates are compared with space radiation intensities, L shell location, and spectral distributions from the radiation spectrometers on CRRES.

Frederickson, A. R.↗

Some results of the oxidation investigation of copper and silver samples flown on LDEF

The Long Duration Exposure Facility (LDEF) Mission provides a unique opportunity to study the long term effects of the space environment on materials. The LDEF has been deployed in orbit on 7 April 1984 by the shuttle Challenger in an almost circular orbit with a mean altitude of 477 km and an inclination of 28.5 degrees. It was retrieved from its decayed orbit of 335 km by the shuttle Columbia on 12 January 1990 after almost 6 years in space. The LDEF is a 12-sided, 4.267 m diameter, and 9.144 m long structure. The experiments, placed on trays, are attached to the twelve sides and the two ends of the spacecraft. The LDEF was passively stabilized with one end of the spacecraft always pointing towards the earth center and one of the sides (row 9) always facing the flight direction. The materials investigated originate from the Ultra-Heavy Cosmic Ray Experiment (UHCRE). The main objective is a detailed study of the charge spectra of ultraheavy cosmic-ray nuclei from zinc to uranium and beyond, using solid-state track detectors. Besides the aluminium alloy used for the experiment, UHCRE comprises several other materials. The results of space exposure for two of them, the copper grounding strips and the thermal covers (FEP Teflon/Ag/Inconel) painted black on the inner side (Chemglaze Z306), are presented.

Derooij, A.↗

Surface contamination on LDEF exposed materials

X-ray photoelectron spectroscopy (XPS) has been used to study the surface composition and chemistry of Long Duration Exposure Facility (LDEF) exposed materials including silvered Teflon (Ag/FEP), Kapton, S13GLO paint, quartz crystal monitors (QCM's), carbon fiber/organic matrix composites, and carbon fiber/Al Alloy composites. In each set of samples, silicones were the major contributors to the molecular film accumulated on the LDEF exposed surfaces. All surfaces analyzed have been contaminated with Si, O, and C; most have low levels (less than 1 atom percent) of N, S, and F. Occasionally observed contaminants included Cl, Na, K, P, and various metals. Orange/brown discoloration observed near vent slots in some Ag/FEP blankets were higher in carbon, sulfur, and nitrogen relative to other contamination types. The source of contamination has not been identified, but amine/amide functionalities were detected. It is probable that this same source of contamination account for the low levels of sulfur and nitrogen observed on most LDEF exposed surfaces. XPS, which probes 50 to 100 A in depth, detected the major sample components underneath the contaminant film in every analysis. This probably indicates that the contaminant overlayer is patchy, with significant areas covered by less that 100 A of molecular film. Energy dispersive x-ray spectroscopy (EDS) of LDEF exposed surfaces during secondary electron microscopy (SEM) of the samples confirmed contamination of the surfaces with Si and O. In general, particulates were not observed to develop from the contaminant overlayer on the exposed LDEF material surfaces. However, many SiO2 submicron particles were seen on a masked edge of an Ag/FEP blanket. In some cases such as the carbon fiber/organic matrix composites, interpretation of the contamination data was hindered by the lack of good laboratory controls. Examination of laboratory controls for the carbon fiber/Al alloy composites showed that preflight contamination was the most significant factor for all the contaminants generally detected at less than 1 atom percent, or detected only occasionally (i.e., all but Si, O, and C). Flight control surfaces, including sample backsides not exposed to space radiation or atomic oxygen flux, have accumulated some contamination on flight (compared to laboratory controls), but experimentally, the LDEF exposed surface contamination levels are generally higher for the contaminants Si and O. For most materials analyzed, Si contamination levels were higher on the leading edge surfaces than on the trailing edge surfaces. This was true even for the composite samples where considerable atomic oxygen erosion of the leading edge surfaces was observed by SEM. It is probable that the return flux associated with atmospheric backscatter resulted in enhanced deposition of silicones and other contaminants on the leading edge flight surfaces relative to the trailing edge. Although the Si concentration data suggested greater on-flight deposition of contaminants on the leading edge surfaces, the XPS analyses did not conclusively show different relative total thicknesses of flight deposited contamination for leading and trailing edge surfaces. It is possible that atomic oxygen reactions on the leading edge resulted in greater volatilization of the carbon component of the deposited silicones, effectively 'thinning' the leading edge deposited overlayer. Unlike other materials, exposed polymers such as Kapton and FEP-type Teflon had very low contamination on the leading edge surfaces. SEM evidence showed that undercutting of the contaminant overlayer and damaged polymer layers occurred during atomic oxygen erosion, which would enhance loss of material from the exposed surface.

Hemminger, Carol S.↗

Effects of the LDEF environment on the Ag/FEP thermal blankets

This presentation was made by Francois Levadou at the NASA Langley Research Center LDEF materials workshop, November 19-22, 1991. It represents the results to date on the examination of silvered teflon thermal blankets primarily from the Ultra-heavy Cosmic Ray Experiment and also from the blanket from the Park Seed Company experiment. ESA/ESTEC and Boeing conducted a number of independent measurements on the blankets and in particular on the exposed fluorinated ethylene-propylene (FEP) layer of the blankets. Mass loss, thickness, and thickness profile measurements have been used by ESA, Boeing, and NASA LeRC to determine recession and average erosion yield under atomic oxygen exposure. Tensile strength and percent elongation to failure data, surface characterization by ESCA, and SEM images are presented. The Jet Propulsion Laboratory analysis of vacuum radiation effects is also presented. The results obtained by the laboratories mentioned and additional results from the Aerospace Corporation on samples provided by Boeing are quite similar and give confidence in the validity of the data.

Levadou, Francois↗