Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FREQUENCY STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Feasibility of an Accelerometer-Based Structural Health Monitoring System for the LANL Blast Tube

A modeling- and simulation-based study was conducted on the feasibility of implementing an accelerometer-based SHM system on the Los Alamos National Laboratory blast tube. A blast tube experiment was modeled using the Abaqus explicit finite element solver. A custom user subroutine was written to apply test-like pressure loading to the inside surface of the blast tube. The subroutine applies analytically defined pressure loads derived from tracer output taken from a Compressible Flow Computational Fluid Dynamics Solver model of the blast tube. Five unique versions of the model were created: an undamaged reference model at 65°F was used as the baseline and compared to equivalent models at 10°F and 100°F. These three models were compared to models with small damage at the reference temperature. The two types of damage considered were a radial (circumferential) crack in the main tube body and a longitudinal crack in the supports. Acceleration outputs were extracted from accelerometer bodies included in the model and were post processed using a variety of standard SHM techniques. Different potential features signaling failure were extracted and compared using statistical methods in the time and frequency domains. A method was identified that clearly shows that differences in structural response resulting from the modeled damage can be differentiated from the structural response resulting from changing environmental conditions. However, the amount of damage applied to create observable differences in the accelerometer data was so large that simpler methods of damage detection would be more cost effective in locating damage.

42 ENGINEERING↗

Event Log / Raw Data

The WFIP3 event log is a curated record spanning 578 days of meteorological phenomena and field observations that complements the campaign’s high-frequency measurements. The log combines manually documented daily weather discussions with automatically derived indicators of key atmospheric processes, providing standardized, publicly available context to support model evaluation, forecast verification, and case-study selection for offshore boundary-layer research.

17 WIND ENERGY↗

The muon g-2 experiment at Fermilab

The E989 collaboration has recently published the most precise measurement of the muon anomalous magnetic moment $a_\mu$ with an uncertainty of $0.46\,\mathrm{ppm}$. The new experimental world average of $a_\mu$ deviates by 4.2 standard deviations from the Standard Model prediction provided by the Muon g-2 Theory Initiative. Emerging results from ab-initio lattice QCD calculations for hadron-physics contributions allow to scrutinize this tantalizing hint for physics beyond the Standard Model for the first time in a three way comparison. To extract the value of $a_\mu$ a frequency comparison experiment is performed with spin-polarized muons confined in a superbly controlled electric and magnetic field environment. A measurement of the difference between the Larmor and the cyclotron frequency, the so-called anomalous spin precession frequency, is combined with a high-precision measurement of the magnetic field environment which is performed using nuclear magnetic resonance techniques. I discussed the most recent result of the Fermilab Muon g-2 experiment's first physics data run performed in 2018. I reported on the experimental improvements implemented for the subsequent science runs that will allow the collaboration to achieve the ultimate goal of $0.14\,\mathrm{ppm}$ uncertainty on $a_\mu$.

Fertl, Martin↗

Measurement of the muon spin precession frequency using the straw tracking detectors at the Fermilab Muon g-2 experiment

The measurement of the anomalous magnetic dipole moment of the muon ($a_{\mu}$) has long stood as an excellent precision test of the Standard Model (SM). The Fermilab Muon g-2 experiment has recently finished data-taking and in July 2023 published its latest determination of $a_\mu$ with a world-leading precision of 0.2\,ppm. In this publication, it surpassed the systematic uncertainty goal defined in the TDR. The analyses of a dataset approximately four times larger than this recent publication is now underway. The principle measurement of the Muon g-2 experiment measures $a_{\mu}$ by taking the ratio of two frequencies; the anomalous precession frequency ($\omega_a$) and the muon-weighted magnetic field of the experiment's storage ring measured from the precession frequency of protons in water using nuclear magnetic resonance (NMR) probes. In all publications to date, $\omega_a$ has been determined using energy deposits in the 24 calorimeters. However, the Fermilab experiment has t wo straw tracker detectors measuring the time and momentum of charged particles which can in principle also be used to to measure $\omega_a$ and such a measurement can provide an invaluable cross-check of the calorimeter result with different, and reduced, systematic uncertainties. This thesis presents the first (blinded) determination of $\omega_a$ using just charged tracks from the straw tracking detectors as opposed to calorimeter energy deposits. This analysis was undertaken using the Run-2/3 dataset which represents approximately 25\% of the final dataset. A total uncertainty of 2.19\,ppm on $\omega_a$ was obtained which is dominated by the statistical uncertainty of 2.16\,ppm. Additionally two new methodologies important to the analysis of the straw tracking data have been developed: one to better determine the track arrival time ($t_0$) and one to determine the level of pileup in the tracking detectors. The new $t_0$ algorithm which incorporates angular information improves t he resolution on the determination of the $t_0$ by a factor of two and results in 19\% more tracks being successfully reconstructed. The data from the trackers is also used to determine the beam profile that weights the magnetic field in the determination of $a_\mu$ and in determining several of the systematic uncertainties in the calorimeter-based $\omega_a$ analysis. A detailed study of the impact of the internal alignment of the tracker, the $t_0$ and pileup on the determination of the beam position was undertaken and propagated through to an uncertainty in the $\omega_a$ determination. These uncertainties were used in the Fermilab Muon g-2 experiment's recent publication in Phys. Rev. Lett.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Numerical schemes for a multi-species BGK model with velocity-dependent collision frequency

Here, we consider a kinetic description of multi-species gas mixture modeled with Bhatnagar-Gross-Krook (BGK) collision operators, in which the collision frequency varies not only in time and space but also with the microscopic velocity. In this model, the Maxwellians typically used in standard BGK operators are replaced by a generalization of such target functions, which are defined by a variational procedure. In this paper we present a numerical method for simulating this model, which uses an Implicit-Explicit (IMEX) scheme to minimize a certain potential function, mimicking the Lagrange functional that appears in the theoretical derivation. We show that theoretical properties such as conservation of mass, total momentum and total energy as well as positivity of the distribution functions are preserved by the numerical method, and illustrate its usefulness and effectiveness with numerical examples.

97 MATHEMATICS AND COMPUTING↗

Mounted Accelerometer Frequency Response of Adhesive Products and Aluminum Frame Quick Mounts

An accelerometer mounting technique has large implications on the frequency range and accuracy of the measurement, with stiffness and the mass relative to the monitored structure as the primary concerns. The International Organization for Standardization (ISO) gives an extensive list in 5348:2021, detailing mounting methods, and provides recommendations for testing mounts that are not specifically defined. In the nuclear industry on the laboratory scale, there is a need for vibration measurements for predictive maintenance and process monitoring that are nondestructive and capable of working in high-temperature environments. Commercial adhesive products with easy application and removal were tested as nondestructive methods, while quick mounts to a commonly used aluminum frame were tested as nondestructive and have potential applicability in high-temperature environments. The sinusoidal excitation method was used, measuring frequencies from 50 Hz to 10 kHz in one-third octave band intervals, utilizing three accelerometers and comparing the results to those obtained with the stud-mounting method. Using the lowest ±3 dB threshold across each accelerometer, foam dots and poster strips were not successful, and foam tapes were accurate up to 2000 Hz, hose clamps and zip ties up to 800 Hz, and a custom 3D printed mount up to 1000 Hz. Knowing the limitations of each mounting technique allows for accurate measurements within the appropriate range.

47 - OTHER INSTRUMENTATION↗

Micromovements and discomfort associated with flight mission with helmet operation tasks with different levels of cognitive workload

When performing stationary tasks under elevated cognitive workload, individuals must perform continual muscle contractions to maintain stability of the body, resulting in fatigue of the postural muscles. When the muscles perform these contractions in a prolonged manner, the body potentially responds through small changes in body movements—micromovements that may lead to discomfort. The study purpose was to evaluate impact of cognitive load on micromovements. The micromovements were measured during three different cognitive workloads; low, medium, and high. The NASA-TLX score was used to evaluate the perceived mental workload and discomfort was assessed by visual analog scale. In total, 60 subjects (30 males and 30 females) were recruited and performed cognitive tasks that simulated flight operations such as changing the radio frequency based on air traffic control messages, balancing the fuel levels in simulated fuel tanks, and aiming a reticle in a designated moving target using the cyclic control. Cognitive load was defined by the frequency of events. Micromovements were defined by changes in the center of pressure (COP) of the seat pan and COP standard deviation. It was found that the high cognitive workloads had the highest NASA-TLX scores including mental demands, temporal demands, and effort. The neck area had the highest overall levels of discomfort followed by upper back. The highest standard deviation for COP shift and number of micromovements occurred for medium cognitive workloads. In conclusion, while there were some interesting trends, few trends reached a statistical significance due to high variability among subjects for the outcome variables.

60 APPLIED LIFE SCIENCES↗

Engineering local strain for single-atom nuclear acoustic resonance in silicon

Mechanical strain plays a key role in the physics and operation of nanoscale semiconductor systems, including quantum dots and single-dopant devices. In this report we describe the design of a nanoelectronic device, where a single nuclear spin is coherently controlled via nuclear acoustic resonance (NAR) through the local application of dynamical strain. The strain drives spin transitions by modulating the nuclear quadrupole interaction. We adopt an AlN piezoelectric actuator compatible with standard silicon metal–oxide–semiconductor processing and optimize the device layout to maximize the NAR drive. We predict NAR Rabi frequencies of order 200 Hz for a single 123Sb nucleus in a wide region of the device. Spin transitions driven directly by electric fields are suppressed in the center of the device, allowing the observation of pure NAR. Using electric field gradient-elastic tensors calculated by the density-functional theory, we extend our predictions to other high-spin group-V donors in silicon and to the isoelectronic 73Ge atom.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Discovering new forces with gravitational waves from supermassive black holes

Supermassive black hole binary mergers generate a stochastic gravitational wave background detectable by pulsar timing arrays. While the amplitude of this background is subject to significant uncertainties, the frequency dependence is a robust prediction of general relativity. Here we show that the effects of new forces beyond the Standard Model can modify this prediction and introduce unique features into the spectral shape. In particular, we consider the possibility that black holes in binaries are charged under a new long-range force, and we find that pulsar timing arrays are capable of robustly detecting such forces. Supermassive black holes and their environments can acquire charge due to high-energy particle production or dark sector interactions, making the measurement of the spectral shape a powerful test of fundamental physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gravitational Waves and Proton Decay: Complementary Windows into Grand Unified Theories

Proton decay is a smoking gun signature of grand unified theories (GUTs). Searches by Super-Kamiokande have resulted in stringent limits on the GUT symmetry-breaking scale. The large-scale multipurpose neutrino experiments DUNE, Hyper-Kamiokande, and JUNO will either discover proton decay or further push the symmetry-breaking scale above 10 16 GeV. Another possible observational consequence of GUTs is the formation of a cosmic string network produced during the breaking of the GUT to the standard model gauge group. The evolution of such a string network in the expanding Universe produces a stochastic background of gravitational waves which will be tested by a number of gravitational wave detectors over a wide frequency range. We demonstrate the nontrivial complementarity between the observation of proton decay and gravitational waves produced from cosmic strings in determining SO(10) GUT-breaking chains. We show that such observations could exclude SO(10) breaking via flipped SU(5) × U(1) or standard SU(5), while breaking via a Pati-Salam intermediate symmetry, or standard SU(5) × U(1), may be favored if a large separation of energy scales associated with proton decay and cosmic strings is indicated. We note that recent results by the NANOGrav experiment have been interpreted as evidence for cosmic strings at a scale of ~10 14 GeV. This would strongly point toward the existence of GUTs, with SO(10) being the prime candidate. We show that the combination with already available constraints from proton decay allows us to identify preferred symmetry-breaking routes to the standard model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Review of the Application Piezoelectric Actuators for SRF Cavity Tuners

Large SRF Linacs and HEP experiments require accurate frequency control, which is achieved using cavity tuners typically actuated by the piezoelectric ceramic stacks. The piezoelectric ceramic stacks became ’standard’ components of the SRF cavity tuner and, depending on the application, could be operated in the different environment: in air, at cryogenic temperature, in vacuum, and submerged in liquid helium. Different applications place different requirements on the piezo actuators, but the important parameters, common to all applications, are the lifetime and reliability of the actuators. Several R&D programs targeting the development of reliable piezo actuators are reviewed in this contribution.

43 PARTICLE ACCELERATORS↗

Magnetic Field Analysis for Fermilab Muon $g-2$

The Muon g-2 experiment E989 at Fermilab measures the anomalous magnetic moment of the muon $a_\mu$ with improved precision compared to the Brookhaven (E821) experiments. The Brookhaven results are in tension with the Standard Model by more than $3\sigma$. The determination of $a_\mu$ requires the measurement of both the muon anomaly frequency, $\omega_a$, and the magnetic field, $\mathbf{B}$, that confines muons in a storage ring. The field is monitored by a set of coordinated nuclear magnetic resonance (NMR) measurements. NMR probes at fixed locations above and below the storage region constantly monitor the field. An in-vacuum trolley equipped with 17 NMR probes maps the muon storage region, and a special water-based NMR probe provides the calibration for the trolley probes. This presentation focuses on the determination of the time-dependent field maps from combining the fixed probe measurements and the trolley maps. The field maps are combined with the muon distribution to derive the average field observed by the muons during the measurement. These proceedings will cover the analysis from the first data run.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with significantly curved x-ray optics

High-accuracy metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate X-ray light with nanometer-scale wavelengths. The current capabilities and possibility for improvements in X-ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. In the case of Fizeau interferometry, metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for measuring slightly curved X-ray optics. However, for even moderately curved aspherical X-ray mirrors the flat-reference calibration is not sufficiently accurate and stitching Fizeau interferometer-based surface metrology is used to mitigate the problem. But still, the retrace and aberration errors, as well as the limited spatial resolution, described with the instrument transfer function (ITF), can be transferred into the optical surface topography of X-ray mirrors obtained in stitching metrology. For ITF calibration, we have developed an original technique, based on test standards structured as two-dimensional (2D) highly-randomized (HR) binary pseudo-random arrays (BPRAs). The technique employs the unique properties of the HR BPRA patterns in the spatial frequency domain., i.e. the inherent 2D power spectral density of the HR BPRA pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. Here, we explore technological, metrological, and analytical aspects essential for calibration of the retrace and aberration errors of Fizeau interferometers using different types of tilted test samples, including a super-polished reference mirror for the re-trace calibration and the uniformly redundant array (URA) BPRA standards for the geometrical distortion (aberration) calibration. While the first method was previously demonstrated by researchers at DIAMOND Light Source, a method based on the URA BPRA is described and demonstrated here for the first time. We outline the design and fabrication process used in fabrication of URA BPRA test standards, and present the results of application of the URA BPRA standards demonstrating the high efficacy of our approach to geometrical distortion calibration of Fizeau interferometers. We also discuss the possible sources of unexpected peculiarities of the systematic errors, including an astigmatic character of the retrace error, observed with Fizeau interferometers at the Advanced Light Source X-Ray Optics Laboratory.

Munechika, Keiko↗

IGRINS RV: A Precision Radial Velocity Pipeline for IGRINS Using Modified Forward Modeling in the Near-infrared

Application of the radial velocity (RV) technique in the near-infrared is valuable because of the diminished impact of stellar activity at longer wavelengths, making it particularly advantageous for the study of late-type stars but also for solar-type objects. In this paper, we present the IGRINS RV open-source python pipeline for computing infrared RV measurements from reduced spectra taken with IGRINS, an R ≡ λ/Δλ ∼ 45,000 spectrograph with simultaneous coverage of the H band (1.49–1.80 μm) and K band (1.96–2.46 μm). Using a modified forward-modeling technique, we construct high-resolution telluric templates from A0 standard observations on a nightly basis to provide a source of common-path wavelength calibration while mitigating the need to mask or correct for telluric absorption. Telluric standard observations are also used to model the variations in instrumental resolution across the detector, including a yearlong period when the K band was defocused. Without any additional instrument hardware, such as a gas cell or laser frequency comb, we are able to achieve precisions of 26.8 m s{sup −1} in the K band and 31.1 m s{sup −1} in the H band for narrow-line hosts. These precisions are empirically determined by a monitoring campaign of two RV standard stars, as well as the successful retrieval of planet-induced RV signals for both HD 189733 and τ Boo A; furthermore, our results affirm the presence of the Rossiter–McLaughlin effect for HD 189733. The IGRINS RV pipeline extends another important science capability to IGRINS, with publicly available software designed for widespread use.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Preliminary Gap Analysis of Existing IEEE 1547 and IEEE 2800 Standards Towards GFM Technology

This document describes the tests that are conducted on generic grid-forming (GFM) distributed energy resource (DER) and inverter-based resource (IBR) models to check if the performance of the model aligns respectively with the IEEE Std 1547 TM -2018 and IEEE Std 2800 TM -2022 requirements. For the IEEE Std 1547 TM -2018 requirements, specifically the tests related to volt-var requirements and frequency droop requirements are conducted. For the IEEE Std 2800 TM -2022 requirements, specifically the tests conducted are related to reactive- power-voltage control requirements, active-power-frequency response requirements, voltage disturbance ride through requirements and phase jump ride through requirements. This is an initial draft/document. There are many more tests still yet to be done to further verify if the existing standards have a gap or inadvertent barrier to GFM technology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SAIL-Isotopologue (SAIL-iso) Field Campaign Report

The SAIL-iso project took place from November 19, 2022 to June 3, 2023 as part of the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Surface Atmosphere Integrated Field Laboratory (SAIL) project at the main project site in Gothic, Colorado. The project sought to use measurements of the stable isotopic composition of water vapor to better understand cloud-aerosol interactions in a remote mountainous watershed. Water vapor isotopologue and humidity measurements were determined using a Los Gatos Research Triple Water Vapor Isotope Analyzer (TWVIA). The instrument was deployed in the guest van and consists of three main components: a water vapor isotope analyzer, a Los Gatos Research Water Vapor Isotope Standard Source (WVISS), and a Los Gatos Research Dry Air Source. Ambient air samples were collected through an inlet located about one meter above roof of the shipping container. Samples were then delivered to the analyzer through Teflon tubing by use of an external pump to minimize the transport time between the inlet and analyzer. The inlet tubing was surrounded by a Briskheat heat trace and insulating material to ensure ambient air samples did not fall below the dew point and result in condensation. The analyzer uses cavity ringdown spectroscopy to report isotopic ratios of ambient air samples at a frequency of 1 Hz. The calibration unit of the instrument was used in conjunction with the dry air source to periodically measure the δ values of standard waters. It uses a nebulizer to push small water droplets into a hot chamber that vaporizes the water without fractionation. This vapor was then transported to the analyzer using a built-in compressor and the dry air source, which allows each standard with known δ values to be measured at a wide range of humidity values for post-measurement calibration of ambient air samples. Multiple sources of uncertainty are introduced at different stages during the data collection and processing. These include (1) instrument precision, (2) uncertainty in the secondary standards, (3) humidity-correction uncertainty, and (4) Vienna Standard Mean Ocean Water – Standard Light Antarctic Precipitation (VSMOW-SLAP) calibration uncertainty. Uncertainty from each step is propagated in quadrature to calculate a total uncertainty of each isotopologue. Uncertainty was determined to be 2.3‰ for δD and 0.4‰ for δ 18 O.

54 ENVIRONMENTAL SCIENCES↗

Water vapor isotopic composition during TRACER IOP

The TRACER-Iso project took place from June 1 to September 30, 2022 as part of the intensive observation period (IOP) of the Tracking Aerosol Convection Interactions (TRACER) project at the main project site at the La Porte, Texas, municipal airport. The project sought to use measurements of the stable isotopic composition of water vapor to better understand cloud-aerosol interactions in deep convection in a polluted urban setting. Water vapor isotopologue and humidity measurements were determined using a Picarro L2130 Water Vapor Isotope Analyzer. The instrument was deployed in the guest van and consists of three main components: a water vapor isotope analyzer, and a Los Gatos Research Water Vapor Isotope Standard Source (WVISS), and a Los Gatos Research Dry Air Source. Ambient air samples were collected through an inlet located about one meter above roof of the shipping container. Samples were then delivered to the analyzer through teflon tubing by use of an external pump to minimize the transport time between the inlet and analyzer. The inlet tubing was surrounded by a Briskheat heat trace and insulating material to ensure ambient air samples did not fall below the dew point and result in condensation. The analyzer uses cavity ringdown spectroscopy to report isotopic ratios of ambient air samples at a frequency of 1 Hz. The calibration unit of the instrument was used in conjunction with the dry air source to periodically measure the δ values of standard waters. It uses a nebulizer to push small water droplets into a hot chamber that vaporizes the water without fractionation. This vapor was then transported to the analyzer using a built-in compressor and the dry air source, which allows each standard with known δ values to be measured at a wide range of humidity values for post-measurement calibration of ambient air samples. There are multiple sources of uncertainty introduced at different stages during the data collection and processing. These include (1) instrument precision, (2) uncertainty in the secondary standards, (3) humidity-correction uncertainty, and (4) VSMOW-SLAP calibration uncertainty. Uncertainty from each step is propagated in quadrature to calculate a total uncertainty of each isotopologue. Uncertainty was determined to be 2.3‰ for δD and 0.4‰ for δ18O.

54 ENVIRONMENTAL SCIENCES↗

Apodization Specific Fitting for Improved Resolution, Charge Measurement, and Data Analysis Speed in Charge Detection Mass Spectrometry

Short-time Fourier transforms with short segment lengths are typically used to analyze single ion charge detection mass spectrometry (CDMS) data either to overcome effects of frequency shifts that may occur during the trapping period or to more precisely determine the time at which an ion changes mass or charge, or enters an unstable orbit. The short segment lengths can lead to scalloping loss unless a large number of zero-fills are used, making computational time a significant factor in real-time analysis of data. Apodization specific fitting leads to a 9-fold reduction in computation time compared to zero-filling to a similar extent of accuracy. This makes possible real-time data analysis using a standard desktop computer. Rectangular apodization leads to higher resolution than the more commonly used Gaussian or Hann apodization and makes it possible to separate ions with similar frequencies, a significant advantage for experiments in which the masses of many individual ions are measured simultaneously. Equally important is a >20% increase in S/N obtained with rectangular apodization compared to Gaussian or Hann, which directly translates to a corresponding improvement in accuracy of both charge measurements and ion energy measurements that rely on the amplitudes of the fundamental and harmonic frequencies. Finally, combined with computing the fast Fourier transform in a lower-level language, this fitting procedure eliminates computational barriers and should enable real-time processing of CDMS data on a laptop computer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗