Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FREQUENCY MODULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Cooling of a mirror in cavity optomechanics with a chirped pulse

We investigate the response of a harmonically confined mirror to an optical pulse in cavity optomechanics. We show that when the pulsed coupling strength takes the form of a chirped pulse, thermal fluctuations of the mirror can be significantly transferred to the cavity field. In addition, the frequency modulation of the pulse could enable a better cooling performance by suppressing the sensitivity of the dependence of detuning and pulse areas. Using numerical investigations, we find that the pulsed cooling is mainly limited by the cavity-field decay rate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simultaneous detection of surface coverage and structure of krypton films on gold by helium atom diffraction and quartz crystal microbalance techniques

We describe a quartz crystal microbalance setup that can be operated at low temperatures in ultra high vacuum with gold electrode surfaces acting as substrate surface for helium diffraction measurements. By simultaneous measurement of helium specular reflection intensity from the electrode surface and resonance frequency shift of the crystal during film adsorption, helium diffraction data can be correlated to film thickness. In addition, effects of interfacial viscosity on the helium diffraction pattern could be observed. To this end, first, flat gold films on AT cut quartz crystals were prepared which yield high enough helium specular reflection intensity. Then the crystals were mounted in the helium diffractometer sample holder and driven by means of a frequency modulation driving setup. Different crystal geometries were tested to obtain the best quality factor and preliminary measurements were performed on Kr films on gold surfaces. While the crystal structure and coverage of krypton films as a function of substrate temperature could successfully be determined, no depinning effects could be observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modes in a pulse-modulated radio-frequency dielectric-barrier glow discharge

This letter reports an experimental study of a pulse-modulated radio-frequency dielectric-barrier discharge in atmospheric helium. By controlling the duty cycle at a modulation frequency of 10 and 100 kHz, the 13.56 MHz discharge is shown to operate in three different glow modes: the continuum mode, the discrete mode, and the transition mode. By investigating plasma ignition, residual electrons during power off are found to affect different glow modes. Duty cycle dependences of power density, gas temperature, optical emission intensities at 706 and 777 nm are used to capture clearly the characteristics of the three glow modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Three axis vector atomic magnetometer utilizing polarimetric technique

The three axis vector magnetic field measurement based on the interaction of a single elliptically polarized light beam with an atomic system is described. The magnetic field direction dependent atomic responses are extracted by the polarimetric detection in combination with laser frequency modulation and magnetic field modulation techniques. The magnetometer geometry offers additional critical requirements like compact size and large dynamic range for space application. Further, the three axis magnetic field is measured using only the reflected signal (one polarization component) from the polarimeter and thus can be easily expanded to make spatial array of detectors and/or high sensitivity field gradient measurement as required for biomedical application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle-in-cell simulations of kinetic effects in plasma-based backward Raman amplification in underdense plasmas

A one dimensional particle-in-cell study of the kinetic effects involved in plasma-based backward Raman amplification is presented for nonrelativistic laser pulses interacting in underdense thermal plasmas. Simulations are performed to study how effects such as particle heating and trapping, frequency modulations, and wave breaking of the plasma wave can change with different plasma conditions. The result of this parametric scan of plasma density and temperature is the identification of optimal plasma conditions for amplification of an ultrashort seed laser pulse by a pump laser of nonrelativistic intensity. The relevance of this study to possible experimental scenarios is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rotational Spectra in 29 Vibrationally Excited States of Interstellar Aminoacetonitrile

We report a detailed spectroscopic investigation of the interstellar aminoacetonitrile, a possible precursor molecule of glycine. Using a combination of Stark and frequency-modulation microwave and millimeter wave spectroscopies, we observed and analyzed the room-temperature rotational spectra of 29 excited states with energies up to 1000 cm{sup −1}. We also observed the {sup 13}C isotopologues in the ground vibrational state in natural abundance (1.1%). The extensive data set of more than 2000 new rotational transitions will support further identifications of aminoacetonitrile in the interstellar medium.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimisation of parameters of Raman laser pulse compression in a plasma for its implementation using the PEARL laser facility (IAP RAS)

We consider Raman compression of laser pulses in a plasma under the conditions of an experiment planned at the Institute of Applied Physics of the Russian Academy of Sciences on the PEARL laser facility. The analysis is based on the equations describing, among other things, the effect of plasma dispersion and relativistic nonlinearity, as well as the dynamics of the field near the plasma wave breaking threshold. It is shown that the main limiting factors are excessive frequency modulation of the pump pulse and a too low plasma density in which the plasma wave breaking can occur. To reduce the negative influence of these effects, we suggest using an intense and short (on the order of the plasma period) seed laser pulse. Numerical simulation shows the possibility of a hundredfold increase in the intensity of the compressed pulse in comparison with the intensity of the pump pulse at a length of uniform plasma of 2 cm. (paper)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of Laser Nitriding on the Surface and Corrosion Properties of Ti-20Nb-13Zr Alloy in Artificial Saliva for Dental Applications

Ti alloys have been used for dentistry due to their lower density and improved compatibility. However, the resistance to corrosion and surface hardness of Ti alloys need to be improved to avoid the formation of debris, which affects the long-term biocompatibility. In the present work, the surface characteristics and corrosion protection in artificial saliva produced by laser nitriding of a new biomedical Ti-20Nb-13Zr at.% alloy have been investigated for dental applications. The laser nitrided and untreated alloy surfaces were examined using XRD, FE-SEM, x-ray photon spectroscopy, Vickers microhardness measurements, atomic force microscopy, scratch measurements, Raman spectroscopy, and surface energy measurements. The susceptibility of the laser nitrided TNZ alloy to corrosion in an artificial saliva medium was investigated by electrochemical corrosion tests, which were performed by utilizing open circuit potential monitoring, electrochemical frequency modulation, and electrochemical impedance spectroscopic methods. The findings revealed that a TiN layer formed on the alloy surface after nitriding. The surface hardness of the treated alloy was 2.4 times that of the as-received samples. Moreover, the results showed improved friction coefficient and hydrophilic surface characteristics. The corrosion analysis revealed that the compact and dense TiN layer produced during laser nitriding improved the corrosion resistance of the Ti-20Nb-13Zr sample in artificial saliva medium.

36 MATERIALS SCIENCE↗

Molecular-scale investigations of structures and surface charge distribution of surfactant aggregates by three-dimensional force mapping

Surface charges on nanoscale structures in liquids, such as biomolecules and nano-micelles, play an essentially important role in their structural stability as well as their chemical activities. These structures interact with each other through electric double layers (EDLs) formed by the counter ions in electrolyte solution. Although static-mode atomic force microscopy (AFM) including colloidal-probe AFM is a powerful technique for surface charge density measurements and EDL analysis on a submicron scale in liquids, precise surface charge density analysis with single-nanometer resolution has not been made because of its limitation of the resolution and the detection sensitivity. Here we demonstrate molecular-scale surface charge measurements of self-assembled micellar structures, molecular hemicylinders of sodium dodecyl sulfate (SDS), by three-dimensional (3D) force mapping based on frequency modulation AFM. The SDS hemicylindrical structures with a diameter of 4.8 nm on a graphite surface were clearly imaged. We have succeeded in visualizing 3D EDL forces on the SDS hemicylinder surfaces and obtaining the molecular-scale charge density for the first time. The results showed that the surface charge on the trench regions between the hemicylinders was much smaller than that on the hemicylinder tops. The method can be applied to a wide variety of local charge distribution studies, such as spatial charge variation on a single protein molecule.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Three-dimensional atomic force microscopy mapping at the solid-liquid interface with fast and flexible data acquisition

We present the implementation of a three-dimensional mapping routine for probing solid-liquid interfaces using frequency modulation atomic force microscopy. Our implementation enables fast and flexible data acquisition of up to 20 channels simultaneously. The acquired data can be directly synchronized with commercial atomic force microscope controllers, making our routine easily extendable for related techniques that require additional data channels, e.g., Kelvin probe force microscopy. Moreover, the closest approach of the tip to the sample is limited by a user-defined threshold, providing the possibility to prevent potential damage to the tip. The performance of our setup is demonstrated by visualizing the hydration structure above the calcite (10.4) surface in water.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dual channel self-oscillating optical magnetometer

We report on a two-channel magnetometer based on nonlinear magneto-optical rotation in a Cs glass cell with buffer gas. The Cs atoms are optically pumped and probed by free running diode lasers tuned to the D{sub 2} line. A wide frequency modulation of the pump laser is used to produce both synchronous Zeeman optical pumping and hyperfine repumping. The magnetometer works in an unshielded environment, and a spurious signal from distant magnetic sources is rejected by means of differential measurement. In this regime the magnetometer simultaneously gives the magnetic field modulus and the field difference. Rejection of the common-mode noise allows for high-resolution magnetometry with a sensitivity of 2 pT/{radical}(Hz). This sensitivity, in conjunction with long-term stability and a large bandwidth, makes it possible to detect water proton magnetization and its free induction decay in a measurement volume of 5 cm{sup 3}.

74 ATOMIC AND MOLECULAR PHYSICS↗

Observation of proximities between spin-1/2 and quadrupolar nuclei: Which heteronuclear dipolar recoupling method is preferable?

We have recently shown that the dipolar-mediated heteronuclear multiple-quantum coherence (D-HMQC) method allows observing through-space proximities between spin-1/2 ({sup 1}H, {sup 13}C, {sup 31}P Horizontal-Ellipsis ) and quadrupolar ({sup 23}Na, {sup 27}Al Horizontal-Ellipsis ) nuclei. However, the D-HMQC effectiveness depends on the choice of the heteronuclear dipolar recoupling sequence. Here, we compare the efficiency and the robustness of four rotor-synchronized sequences: the symmetry-based ones, R4{sub 1}{sup 2}R4{sub 1}{sup -2} and its super-cycled version, SR4{sub 1}{sup 2}, and two schemes based on simultaneous amplitude and frequency modulations, denoted SFAM-1 and SFAM-2. For the SFAM methods, we point out efficient recoupling conditions that facilitate their experimental optimization and we introduce analytical expressions for the buildup of D-HMQC signal in the case of an isolated spin pair. We show that the main differences between these four sequences lie in the number of adjustable parameters and in their robustness with respect to chemical shift and homonuclear dipolar interactions. The relative performances of these four recoupling sequences are analyzed using average Hamiltonian theory, numerical simulations, and {sup 27}Al-{l_brace}{sup 31}P{r_brace} D-HMQC experiments on crystalline aluminophosphate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transient Laser Absorption Spectroscopy of CH2 near 780 nm

Bands in the CH{sub 2} {tilde b}{sup 1} B{sub 1}-{tilde a}{sup 1} A{sub 1} transition between 12,500 and 13,000 cm{sup -1} were recorded at Doppler-limited resolution using a transient frequency-modulation (FM) laser absorption spectrometer. Rotational levels in seven upper vibronic states: {tilde a}(a, 11, 0){sup 1,3}, {tilde a}(2, 6,0){sup 1}, {tilde b}(0, 2, 0){sup 4}, {tilde b}(1, 1, 0){sup 1,2}, and {tilde b}(0, 3, 0){sup 1} were assigned with the assistance of optical-optical double resonance (OODR) and ground state combination differences. Perturbations due to rotation-vibration coupling, anharmonic couplings, {ell}-resonance, as well as the Renner-Teller effect are discussed as sources of the irregular rotational patterns observed in the {tilde b}(0, 3, 0){sup 1}, {tilde b}(1, 1, 0){sup 1}, and {tilde a}(0, 11, 0){sup 3} vibronic levels.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SAR impulse response with residual chirps.

A Linear Frequency-Modulated (LFM) chirp is a function with unit amplitude and quadratic phase characteristic. In a focused Synthetic Aperture Radar (SAR) image, a residual chirp is undesired for targets of interest, as it coarsens the manifested resolution. However, for undesired spurious signals, a residual chirp is often advantageous because it spreads the energy and thereby diminishes its peak value. In either case, a good understanding of the effects of a residual LFM chirp on a SAR Impulse Response (IPR) is required to facilitate system analysis and design. This report presents an analysis of the effects of a residual chirp on the IPR. As reference, there is a rich body of publications on various aspects of LFM chirps. A quick search reveals a plethora of articles, going back to the early 1950s. We mention here purely as trivia one of the earlier analysis papers on this waveform by Klauder, et al.

47 OTHER INSTRUMENTATION↗

Characterisation of a cryostat using simultaneous, single-beam multiple-surface laser vibrometry

A novel range-resolved interferometric signal processing technique that uses sinusoidal optical frequency modulation is applied to multi-surface vibrometry, demonstrating simultaneous optical measurements of vibrations on two surfaces using a single, collimated laser beam, with a minimum permissible distance of 3.5 cm between surfaces. The current system, using a cost-effective laser diode and a fibre-coupled, downlead insensitive setup, allows an interferometric fringe rate of up to 180 kHz to be resolved with typical displacement noise levels of 8 pm · Hz{sup −05}. In this paper, the system is applied to vibrometry measurements of a table-top cryostat, with concurrent measurements of the optical widow and the sample holder target inside. This allows the separation of common-mode vibrations of the whole cryostat from differential vibrations between the window and the target, allowing any resonances to be identified.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A tuning fork based wide range mechanical characterization tool with nanorobotic manipulators inside a scanning electron microscope

This study proposes a tuning fork probe based nanomanipulation robotic system for mechanical characterization of ultraflexible nanostructures under scanning electron microscope. The force gradient is measured via the frequency modulation of a quartz tuning fork and two nanomanipulators are used for manipulation of the nanostructures. Two techniques are proposed for attaching the nanostructure to the tip of the tuning fork probe. The first technique involves gluing the nanostructure for full range characterization whereas the second technique uses van der Waals and electrostatic forces in order to avoid destroying the nanostructure. Helical nanobelts (HNB) are proposed for the demonstration of the setup. The nonlinear stiffness behavior of HNBs during their full range tensile studies is clearly revealed for the first time. Using the first technique, this was between 0.009 N/m for rest position and 0.297 N/m before breaking of the HNB with a resolution of 0.0031 N/m. For the second experiment, this was between 0.014 N/m for rest position and 0.378 N/m before detaching of the HNB with a resolution of 0.0006 N/m. This shows the wide range sensing of the system for potential applications in mechanical property characterization of ultraflexible nanostructures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photothermal excitation setup for a modified commercial atomic force microscope

High-resolution imaging in liquids using frequency modulation atomic force microscopy is known to suffer from additional peaks in the resonance spectrum that are unrelated to the cantilever resonance. These unwanted peaks are caused by acoustic modes of the liquid and the setup arising from the indirect oscillation excitation by a piezoelectric transducer. Photothermal excitation has been identified as a suitable method for exciting the cantilever in a direct manner. Here, we present a simple design for implementing photothermal excitation in a modified Multimode scan head from Bruker. Our approach is based on adding a few components only to keep the modifications as simple as possible and to maintain the low noise level of the original setup with a typical deflection noise density of about 15 fm/√(Hz) measured in aqueous solution. The success of the modification is illustrated by a comparison of the resonance spectra obtained with piezoelectric and photothermal excitation. The performance of the systems is demonstrated by presenting high-resolution images on bare calcite in liquid as well as organic adsorbates (Alizarin Red S) on calcite with simultaneous atomic resolution of the underlying calcite substrate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance and data analysis aspects of the new DIII-D monostatic profile reflectometer system

A new frequency-modulated profile reflectometer system, featuring a monostatic antenna geometry (using one microwave antenna for both launch and receive), has been installed on the DIII-D tokamak, providing a first experimental test of this measurement approach for profile reflectometry. Significant features of the new system are briefly described in this paper, including the new monostatic arrangement, use of overmoded, broadband transmission waveguide, and dual-polarization combination/demultiplexing. Updated data processing and analysis, and in-service performance aspects of the new monostatic profile reflectometer system are also presented. By using a raytracing code (GENRAY) to determine the approximate trajectory of the probe beam, the electron density (n{sub e}) profile can be successfully reconstructed with L-mode plasmas vertically shifted by more than 10 cm off the vessel midplane. Specifically, it is demonstrated that the new system has a capability to measure n{sub e} profiles with plasma vertical offsets of up to ±17 cm. Examples are also presented of accurate, high time and spatial resolution density profile measurements made over a wide range of DIII-D conditions, e.g., the measured temporal evolution of the density profile across a L-H transition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗