Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FORENSIC SCIENCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Detection of Acetone Processing of Castor Bean Mash for Forensic Investigation of Ricin Preparation Methods

The toxic protein ricin is of concern as a potential biological threat agent (BTA) Recently, several samples of ricin have been seized in connection with biocriminal activity. Analytical methods are needed that enable federal investigators to determine how the samples were prepared, to match seized samples to potential source materials, and to identify samples that may have been prepared by the same method using the same source materials. One commonly described crude ricin preparation method is acetone extraction of crushed castor beans. Here we describe the use of solid-phase microextraction and headspace analysis of crude ricin preparation samples to determine whether they were processed by acetone extraction. In all cases, acetone-extracted bean mash could be distinguished from un-extracted mash or mash extracted with other organic solvents. Statistical analysis showed that storage in closed containers for up to 109 days had no effect on acetone signal intensity. Signal intensity in acetone-extracted mash decreased during storage in open containers, but extracted mash could still be distinguished from un-extracted mash after 94 days.

59 BASIC BIOLOGICAL SCIENCES↗

DICER: A new instrument at LANSCE to constrain neutron capture rates on radionuclides

With very few exceptions, direct measurements of neutron capture rates on radionuclides have not been possible. A number of indirect methods have been pursued such as the surrogate method, the γ-ray strength function method, the Oslo method and the β-Oslo method. Substantial effort has been devoted to quantify the usually large systematic errors that accompany the results from these techniques. A new instrument has been developed at the Los Alamos Neutron Science Center (LANSCE) to provide more accurate data on several radionuclides relevant to nuclear criticality safety, radiochemical diagnostics, astrophysics, nuclear forensics and nuclear security, by measuring the transmission of neutrons through radioactive samples and studying resonance properties. The Device for Indirect Capture on Radionuclides (DICER) and associated radionuclide production at the Isotope Production Facility (IPF), both at LANSCE, as well radioactive sample fabrication, have been under development the last few years. A description of the new apparatus, data on a few mid-weight stable isotopes and efforts on radionuclide measurements will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Round-robin 230 Th– 234 U age dating of bulk uranium for nuclear forensics

In an inter-laboratory measurement comparison study, four laboratories determined 230 Th– 234 U model ages of uranium certified reference material NBL U050 using isotope dilution mass spectrometry. The model dates determined by the participating laboratories range from 9 March 1956 to 19 October 1957, and are indistinguishable given the associated measurement uncertainties. As a result, these model ages are concordant with to slightly older than the known production age of NBL U050.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Use of Stable Isotopes in Forensic Analysis of Microorganisms

The use of isotopic signatures for forensic analysis of biological materials is well-established, and the same general principles that apply to interpretation of stable isotope content of C, N, O, and H apply to the analysis of microorganisms. Heterotrophic microorganisms derive their isotopic content from their growth substrates, which are largely plant and animal products, and the water in their culture medium. Thus the isotope signatures of microbes are tied to their growth environment. The C, N, O, and H isotope ratios of spores have been demonstrated to constitute highly discriminating signatures for sample matching. They can rule out specific samples of media and/or water as possible production media, and can predict isotope ratio ranges of the culture media and water used to produce a given sample. These applications have been developed and tested through analyses of approximately 250 samples of Bacillus subtilis spores and over 500 samples of culture media, providing a strong statistical basis for data interpretation. A Bayesian statistical framework for integrating stable isotope data with other types of signatures derived from microorganisms has been able to characterize the culture medium used to produce spores of various Bacillus species, leveraging isotopic differences in different medium types and demonstrating the power of data integration for forensic investigations.

59 BASIC BIOLOGICAL SCIENCES↗

Comparing results of X-ray diffraction, µ-Raman spectroscopy and neutron diffraction when identifying chemical phases in seized nuclear material, during a comparative nuclear forensics exercise

This work presents the results for identification of chemical phases obtained by several laboratories as a part of an international nuclear forensic round-robin exercise. In this work powder X-ray diffraction (p-XRD) is regarded as the reference technique. Neutron diffraction produced a superior high-angle diffraction pattern relative to p-XRD. Requiring only small amounts of sample, µ-Raman spectroscopy was used for the first time in this context as a potentially complementary technique to p-XRD. The chemical phases were identified as pure UO 2 in two materials, and as a mixture of UO 2 , U 3 O 8 and an intermediate species U 3 O 7 in the third material.

36 MATERIALS SCIENCE↗

Evaluation of the Radioactive Material Released in the Harborview Research and Training Building and Some Implications for Emergency Response

On 2 May 2019, during the 137 Cs source recovery operation, a source capsule in a research irradiator containing approximately 77.1 TBq was breached. Based on a geometric reconstruction analysis of the damage to the capsule, approximately 46.3 GBq (0.04%) was impacted by the chop saw (grinder) inside a mobile hot cell on the loading dock at the University of Washington Harborview Research and Training (HRT) Building. A very small fraction of the material impacted, less than 1%, was released from the mobile hot cell and then to the rest of the HRT Building. The objectives of this project were to assess the accidental release of 137 CsCl and its implications related to emergency response methods and the ramifications of 137 CsCl transport. The phenomenology of this event was also compared with past alkali halide dispersal events. The vast number of measurements and samples collected by the remediation contractors, the Department of Energy’s Nuclear Emergency Support Team, and the small number of retrospective samples collected by the authors informed the analysis. The techniques included (1) autoradiography and electron microscopy of samples collected from the HRT Building and the irradiator, (2) 3D visualization of deposition on surfaces and within the ventilation system, and (3) a study of the damage to the source capsule to evaluate the Cs particle size and particle composition due to the grinding accident. Subsequently, the cesium contaminant transport through the numerous pathways in the building was reconstructed to assess the deposition on surfaces as a function of particle size. Furthermore, the implications for emergency response are relevant to data quality and management. A Data Quality Objective guides data collection methods so that they have appropriate accuracy and precision for the intended application. Recommendations were made with respect to the sample collection protocols and archiving of samples.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

The Power of Exclusion using Automated Osteometric Sorting: Pair‐Matching,

Abstract This study compares the original pair‐matching osteometric sorting model ( J Forensic Sci 2003 ;48:717) against two new models providing validation and performance testing across three samples. The samples include the Forensic Data Bank, USS Oklahoma , and the osteometric sorting reference used within the Defense POW / MIA Accounting Agency. A computer science solution to generating dynamic statistical models across a commingled assemblage is presented. The issue of normality is investigated showing the relative robustness against non‐normality and a data transformation to control for normality. A case study is provided showing the relative exclusion power of all three models from an active commingled case within the Defense POW / MIA Accounting Agency. In total, 14,357,220 osteometric t ‐tests were conducted. The results indicate that osteometric sorting performs as expected despite reference samples deviating from normality. The two new models outperform the original, and one of those is recommended to supersede the original for future osteometric sorting work.

Lynch, Jeffrey James↗

Spectral Data Fusion From Handheld Laser-Induced Breakdown Spectroscopy (LIBS) and X-ray Fluorescence (XRF) Analyzers for Improved Detection of Cerium in a Simulated Dispersal Accident

Here, this work implements a mid-level data fusion methodology on spectral data from handheld X-ray fluorescence and laser-induced breakdown spectroscopy analyzers to quantify plutonium surrogate (CeO 2 ) contamination in soil samples for the first time. Spectral data from each analyzer were used independently to train supervised machine learning regressions to predict Ce concentration. Fused features from both data sets were then used to train the same models, comparing prediction performance by evaluating model precision and sensitivity. Fusing principal component scores from the two sensors yielded an order of magnitude improvement in precision and sensitivity of predictions made with an artificial neural network, compared to predictions made by models trained on independent sensor data. As a result, a boosted ensemble trained on the fused spectral features yielded an ideal predictor with root-mean-squared error on the order of 10 –6 and calculated limit of detection order 10 –5 wt %.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TA-55 Plutonium Facility Fact Sheet

At the Los Alamos National Laboratory (LANL), virtually all plutonium operations occur within the Plutonium Facility at Technical Area 55 (TA-55). TA-55 is the nation’s most modern plutonium science and manufacturing facility, and is the only fully operational, full capability plutonium facility in the nation. TA-55 supports a wide range of national security programs that involve: 1) stockpile stewardship. 2) plutonium processing. 3) nuclear materials stabilization. 4) materials disposition. 5) nuclear forensics. 6) nuclear counter-terrorism. 7) nuclear energy. Operations at TA-55 maintain a critical skill base of plutonium expertise across a broad suite of technical capabilities. These capabilities form a center of excellence for actinide science and technology, including world-class manufacturing for solving significant national security challenges.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A non-destructive internal nuclear forensic investigation at Argonne: discovery of a Pu planchet from 1948

A plutonium alpha standard dating from 1948 was discovered at Argonne National Laboratory and characterized using a number of non-destructive analytical techniques. The principle radioactive isotope was found to be 239 Pu and unique ring structures were found across the surface of the deposition area. Due to chronological constraints on possible sources and its high isotopic purity, the plutonium in the sample was likely produced by the Oak Ridge National Lab X-10 Reactor. As a result, it is proposed that the rings are resultant through a combination of polishing and electrodeposition, though the hypothesis fails to address a few key features of the ring structures.

239Pu↗

DICER: A new instrument at LANSCE to constrain neutron capture rates on radionuclides

. With very few exceptions, direct measurements of neutron capture rates on radionuclides have not been possible. A number of indirect methods have been pursued such as the surrogate method, the γ-ray strength function method, the Oslo method and the β-Oslo method. Substantial effort has been devoted to quantify the usually large systematic errors that accompany the results from these techniques. A new instrument has been developed at the Los Alamos Neutron Science Center (LANSCE) to provide more accu rate data on several radionuclides relevant to nuclear criticality safety, radiochemical diagnostics, astrophysics, nuclear forensics and nuclear security, by measuring the transmission of neutrons through radioactive samples and studying resonance properties. The Device for Indirect Capture on Radionuclides (DICER) and as sociated radionuclide production at the Isotope Production Facility (IPF), both at LANSCE, as well radioactive sample fabrication, have been under development the last few years. A description of the new apparatus, data on a few mid-weight stable isotopes and efforts on radionuclide measurements will be presented.

Nuclear Criticality Safety Program (NCSP)↗