Experimental study of R452B and R454B as drop-in replacement for R410A in split heat pumps having tube-fin and microchannel heat exchangers

The objective of this study is to experimentally evaluate two residential split heat pumps using low-GWP refrigerants, i.e., R452B and R454B, and compare the results against R410A. In this work, each heat pump used the same model of two-speed scroll compressor, the same indoor blower and outdoor fan. However, they were distinguished by the indoor and outdoor heat exchanger types: tube-fin heat exchangers (TFHXs) in one case, and microchannel heat exchangers (MCHXs) in the other. The two heat pumps were extensively evaluated following the test conditions for two-speed SEER (cooling seasonal energy efficiency rating)/HSPF (heating seasonal performance factor) ratings.In general, these results show that R452B and R454B are good replacement candidates for R410A for heat pump using tube-fin heat exchangers and microchannel heat exchangers. R452B and R454B led to lower capacities. In the TFHX heat pump, on average, compared to the performance of R410A, the cooling capacity of R452B is 96%; the heating capacity of R452B is 91%; the cooling capacity of R454B is 95%, the heat capacity of R454B is 89%. In the MCHX heat pump, the cooling capacity of R452B is 97%; the heating capacity of R452B is 97%; the cooling capacity of R454B is 98%, the heat capacity of R454B is 97%. With respect to cooling and heating seasonal performances, in the TFHX heat pump, the SEERs of R452B and R454B are 1.5% lower than R410A. HSPFs of the three refrigerants are identical. In the MCHX heat pump, R454B has 7% higher SEER, and R452B has 2% higher SEER than R410A; in heating mode, R454B has the same HSPF as R410A, while R452B is 4% more efficient. The compressor lubricant overheating issue of R452B and R454B, at low ambient heating condition, high stage, should be noticed.

42 ENGINEERING↗

Experimental investigation on phase change material–based finned tube heat exchanger for thermal energy storage and building envelope thermal management

Phase change materials (PCMs) are attractive solutions for thermal energy storage (TES) applications by absorbing and releasing large amounts of latent heat during solid–liquid phase transitions. However, their relatively low thermal conductivity requires novel heat exchanger–based solutions to improve the power density and overall energy storage efficiency of the TES system. This work presents the design and experimental results of a finned tube heat exchanger to store collected natural thermal energy from a building envelope in a latent-based TES and to release it later for building heating/cooling applications. We experimentally evaluate the finned tube heat exchanger and evaluate the performance of TES in reducing building heating and cooling loads over 3–4 h of desired time of operation (e.g., peak load). The optimized design allows for maximum energy density by minimizing the heat exchanger volume, and the system is evaluated experimentally using commercially available heat exchanger materials and an organic PCM. Here, the experimental results reveal that the TES system is able to charge and discharge stored latent energy within 3–4 h, matching peak building electricity demand duration under an average fluid flow rate of 0.136 kg/s and temperature difference of 5.55 °C. Importantly, such optimized designs illuminate a path toward TES designs that are low-cost, scalable, and optimized for thermal energy and power availability under the desired time of operation.

25 ENERGY STORAGE↗

Evaluation and development of flow condensation correlations using the data from low GWP refrigerants in an axial micro-fin aluminum tube

To mitigate global warming, the world is transitioning to refrigerants with low global warming potential (GWP). Supporting this shift requires a model that can accurately predict the heat transfer and pressure drop of new refrigerants, crucial for designing efficient heat exchangers. Existing models, however, are largely based on currently deployed refrigerants and primarily developed for unexpanded micro-fin tubes with spiral angles of 6° to 30°. Their applicability to new refrigerants, especially in expanded micro-fin tubes, is uncertain. This study assesses the performance of four well-known condensation models for six emerging refrigerants—R-32, R-454B, R-454C, R-455A, R-1234yf, and R-1234ze(E)—against experimental data. Initially, the Han and Lee (2005) model shows the best prediction accuracy with a mean absolute deviation (MAD) of 22.1 %. To enhance the accuracy of heat transfer models for new refrigerants and geometries with large temperature glides, two approaches are proposed. Here, the first approach applies a simple correction factor, reducing the MAD of the Cavallini et al. (2009) model from 68.2 % to 15.4 %. The second approach uses the variable metric method for minimization, fitting new constants to the data. This optimization results in the Kedzierski and Goncalves (1997) model achieving the highest accuracy, with a MAD of 13.1 %. For pressure drop models, the Cavallini et al. (1997) model is the most accurate with a MAD of 6.4 %, followed by the Haraguchi et al. (1993) model with a MAD of 9.4 %. Due to its simplicity, the Haraguchi et al. (1993) model is a practical option for predicting frictional pressure drop.

Axial micro-fin tubes↗

The Effects of Threshold Voltage and Number of Fins per Transistor on the TID Response of GF 12LP Technology

This abstract presents a comprehensive analysis of total ionizing dose (TID) response in GlobalFoundries’ 12LP 12nm bulk FinFET technology using 10keV X-rays. Devices with higher threshold voltages (VTs) demonstrated lower increases in off-state leakage current (IDS,OFF) post-irradiation, highlighting the mitigating role of high VT in TID response. Our data shows that transistors with fewer fins exhibit superior TID resistance, implying lower susceptibility to radiation effects. Our study also probed two bias conditions, "Gate-On" and "Pass-Gate," with the former displaying more severe TID degradation. Interestingly, p-type devices displayed negligible degradation, underscoring their inherent resilience to TID effects. Additionally, medium thick n-type devices echoed the fin-count-dependent TID response observed in other transistor types, further strengthening our findings. These results underscore the importance of strategic transistor selection and design for enhancing the TID resilience of future CMOS FinFET architectures, particularly critical in radiation-intense environments.

42 ENGINEERING↗

Comparison of Shape Optimization Methods for Heat Exchanger Fins Using Computational Fluid Dynamics

Inverse design techniques are one way to leverage advances in 3D printing, artificial intelligence, and computational resources to achieve increased performance of heat exchangers. Two optimization techniques (genetic algorithm and particle swarm) and three geometry representations (binary level set, composite Bézier, and free form deformation) are used to increase the heat transfer and reduce the pressure drop of a heat exchanger fin. After running 210,810 OpenFOAM simulations, results indicate that a significant performance increase of the fin can be realized in less than 48 hrs, allowing for such a process to be integrated in traditional design processes. The best design increased the performance of the objective function, compared to the baseline rectangular geometry by 75%. A custom distributed infrastructure was built, allowing for all methods to reach 95% of the final objective values in a little over 4 hrs, handling 1674 OpenFoam simulations per hour.

42 ENGINEERING↗

High temperature study of flexible silicon-on-insulator fin field-effect transistors

We report high temperature electrical transport characteristics of a flexible version of the semiconductor industry's most advanced architecture: fin field-effect transistor on silicon-on-insulator with sub-20 nm fins and high-κ/metal gate stacks. Characterization from room to high temperature (150 °C) was completed to determine temperature dependence of drain current (I{sub ds}), gate leakage current (I{sub gs}), transconductance (g{sub m}), and extracted low-field mobility (μ{sub 0}). Mobility degradation with temperature is mainly caused by phonon scattering. The other device characteristics show insignificant difference at high temperature which proves the suitability of inorganic flexible electronics with advanced device architecture.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Aero-thermal numerical characterization of blunt fin-induced shock wave–boundary layer interaction and its control through leading-edge cooling injection

This study represents a novel evaluation of active flow control to alleviate the aerothermal penalties created by the blunt fin-induced shock wave–boundary layer interaction. The manuscript analyzes the effect of flow injection on a blunt fin-induced shock wave–boundary layer interaction via computational fluid dynamics simulations with various degrees of resolution. The impact on the mean flow topology and wall variables was investigated utilizing Reynolds-averaged Navier–Stokes simulations. Detached-eddy simulations revealed the low-frequency shock motion, shock wave–boundary layer, and horseshoe vortex interaction. The test article was exposed to two different incoming boundary layer thicknesses; the thicker boundary layer led to the appearance of larger turbulent scales. The Detached-eddy simulations revealed the time history of the shock wave–boundary layer interaction, focusing on the inception and development of the recirculated flow regions. Ultimately, spectral proper orthogonal decomposition was employed to identify the structures associated with the low-frequency shock motion caused by the shock wave–boundary layer interaction.

Lozano, Francisco (ORCID:0000000277871125)↗

Using system identification in modeling the yaw response of tail fins for small wind turbines with bearing friction

Here, we describe three main developments of our previous study of the nonlinear yaw dynamics of the tail fins for small wind turbines [Khedr et al., J. Renewable Sustainable Energy 16, 053305 (2024)]. First, the model constants derived from archived computational and experimental studies are adjusted by employing system identification (SI) to maximize the model's agreement with wind tunnel tests. This adjustment was done for high wind speeds, where yaw bearing friction can be ignored. When starting a turbine at low wind speed, however, friction can become important. Our second development is to implement a model for the frictional resistive torque and use SI to maximize its accuracy. These developments used wind tunnel experiments on generic delta, elliptical, and rectangular planforms that were described by Khedr et al. [J. Renewable Sustainable Energy 16, 053305 (2024)]. Since the aerodynamic and friction models employ a large number of constants, we describe ways to constrain the values using linearized solutions of the response equations for small and large yaw angles. Third, we test the generality of the aerodynamic and friction modeling using the complex planform from a commercial small turbine, for which limited theoretical and computational guidance is available in selecting the model constants. The model implemented with SI is shown to provide an accurate description of the yaw response of the complex planform. Guidelines are given for the use of wind tunnel tests to determine the model constants for tail fins of any planform.

17 WIND ENERGY↗

Experimental investigation of subcooled flow boiling of a 50/50 ethylene glycol/water mixture in finned rectangular aluminum channels

Subcooled flow boiling heat transfer experiments were performed with a 50/50 ethylene glycol/water mixture in a finned aluminum channel. The channel represented a hybrid electric vehicle power electronic cold plate receiving a 50/50 mixture from the radiator at 105 degrees C and 2atmospheres. Experiments used a range of mixture flow rates and both top- and bottom-heating situations. Boiling curves were generated, and subcooled flow boiling heat transfer coefficients were determined including the test channel fin effects. Subcooled flow boiling heat transfer coefficients showed a 25-30% increase compared to single-phase convection.

boiling curve↗

Effects of Pin Detached Space on Heat Transfer and Pin-Fin Arrays

Heat transfer and pressure characteristics in a rectangular channel with pin-fin arrays of partial detachment from one of the endwalls have been experimentally studied. The overall channel geometry (W=76.2 mm, E=25.4 mm) simulates an internal cooling passage of wide aspect ratio (3:1) in a gas turbine airfoil. With a given pin diameter, D=6.35 mm=¼E, three different pin-fin height-to-diameter ratios, H/D=4, 3, and 2, were examined. Each of these three cases corresponds to a specific pin array geometry of detachment spacing (C) between the pin tip and one of the endwalls, i.e., C/D=0, 1, 2, respectively. The Reynolds number, based on the hydraulic diameter of the unobstructed cross-section and the mean bulk velocity, ranges from 10,000 to 25,000. The experiment employs a hybrid technique based on transient liquid crystal imaging to obtain the distributions of the local heat transfer coefficient over all of the participating surfaces, including the endwalls and all the pin elements. Experimental results reveal that the presence of a detached space between the pin tip and the endwall has a significant effect on the convective heat transfer and pressure loss in the channel. The presence of pin-to-endwall spacing promotes wall-flow interaction, generates additional separated shear layers, and augments turbulent transport. In general, an increase in detached spacing, or C/D, leads to lower heat transfer enhancement and pressure drop. However, C/D=1, i.e., H/D=3, of a staggered array configuration exhibits the highest heat transfer enhancement, followed by the cases of C/D=0 and C/D=2, i.e., H/D=4 or 2, respectively.

42 ENGINEERING↗

Effect of Thermal Expansion Coefficient, Viscosity and Melting Range in Simulation of PCM Embedded Heat Exchangers With and Without Fins

Phase change material heat exchangers (PCMHX) have an important role in integrating renewable energy systems. PCMHX can offer high storage density at various temperatures of interest and can be used for grid load shifting purposes. Numerical models enable engineers to estimate PCMHX performance for different design parameters and operating conditions. Modeling phase change phenomena is challenging due to the complex time-dependent nature of the process. The accuracy of models is highly sensitive to PCM thermo-physical properties. Thermal expansion coefficient (β), viscosity (μ) and melting temperature range (MR) of a PCM are important properties, especially when natural convection is not negligible. In PCMHX modeling, using less than accurate values for these properties can have significant impact on the simulation outcomes. These properties and discussions thereof are not readily available in the literature. This paper presents a brief review of the literature and a numerical study investigating the model sensitivity to the above-mentioned properties for PCMHX with and without fins. CFD is used to evaluate the charging (melting) phenomena. The study quantifies the impact of uncertainty in these properties on the melting rate and temperature profile. Constant wall temperature was considered as heat source with no heat loss to ambient. Here, the results show that β and μ has significant effect on the melting rate and evolution of the melting front. For a non-finned domain when comparing results for different published values of β and μ, the deviation in melting time can be up to 12.9% and 57.6% respectively. For high wall temperatures, change in melting range did not impact melting time. But when the wall temperature is reduced, up to 9.8% deviation in melting time is observed.

CFD↗

Aerodynamic Characteristics at a Mach Number of 6.8 of Two Hypersonic Missile Configurations, One with Low-Aspect-Ratio Cruciform Fins and Trailing-Edge Flaps and One with a Flared Afterbody and All-Movable Controls

An investigation has been made to determine the aerodynamic characteristics in pitch at a Mach number of 6.8 of hypersonic missile configurations with cruciform trailing-edge flaps and with all-movable control surfaces. The flaps were tested on a configuration having low-aspect-ratio cruciform fins with an apex angle of 5 degrees; the all-movable controls were mounted at the 46.7-percent body station on a configuration having a 10 degrees flared afterbody. The tests were made through an angle-of-attack range of -2 degrees to 20 degrees at zero sideslip in the Langley 11-inch hypersonic tunnel. The results indicated that the all-movable controls on the flared-afterbody model should be capable of producing much larger values of trim lift and of normal acceleration than the trailing-edge-flap configuration. The flared-afterbody configuration had considerably higher drag than the cruciform-fin model but only slightly lower values of lift-drag ratio.

Bernot, P. T.↗

Space shuttle: Aerodynamic characteristics of a composite booster/040A orbiter launch configuration with fin and booster body configuration effect contribution

An investigation was made of the fin configuration and booster body configuration effects on a composite booster/040A orbiter launch configuration. Aerodynamic performance and stability characteristics in pitch and yaw were obtained. Configurations tested included two stepped cylindrical bodies of different lengths with a conical nose, four fin shapes of various sizes and aspect ratios mounted in different positions around the base of the bodies, two base flare angles and three 040A orbiter configurations. The orbiter variations included a tailless configuration and two tail sizes. A tailless booster launch configuration with deflected petals (expanded flare sectors) was also tested. The model scale was 0.003366. Data were converted to coefficient form in near real time, punched on cards, and tabulated. The cards used in conjunction with a Benson-Lehner plotter were used to provide plotted data. At the end of the test, tabulated input forms were completed for the SADSAC computer program to aid in publishing the final test data report.

Ainsworth, R. W.↗

Space shuttle: Aerodynamic characteristics of cone-cylinder-flare-fin configurations at Mach numbers of 1.96, 2.74, and 4.96 and angles of attack from 50 to 90 degrees

A 0.00227-scale parametric model of an LMSC/MSFC water recoverable booster was tested in the MSFC 14 x 14-inch trisonic wind tunnel. The purpose of the test was to obtain high angle of attack force and static stability data which could be used by MSFC in preliminary design and aerodynamic trade studies. These data were obtained using six-component internal strain gauge balances. One hundred forty-four different geometrical combinations were possible as all model parts were interchangeable (three nose cones, three cylinder lengths, four flare sections and three sets of fins, plus a no-fin case in combination with the other components). However, due to tunnel occupancy limitations, only the most representative combinations were tested. All configurations investigated were tested at Mach 1.96, 2.74 and 4.96 with data obtained at angles of attack from 50 degrees to 90 degrees and at angles of sideslip from -10 degrees to +10 degrees (at an angle of attack of 60 degrees).

Bradley, D.↗

Design and testing a high fuel volume fraction, externally finned, thermionic emitter.

A prototypical, high fuel volume fraction, thermionic emitter body was designed and tested. The emitter body is all tungsten, with a 1.40-cm ID, a 3.23-cm OD, and eight full-length axial fins. The emitter thickness is 0.15 cm while the fins and outer clad are 0.075 cm thick. Different methods of fabrication were used in making the test samples. Stress analysis was performed with a three-dimensional elastic code. Thermal testing of the samples, duplicating calculated radial temperature gradients, heatup and cooldown rates, and emitter body temperatures in operation, was performed with no structural failures noted (six heatup and cooldown cycles per sample). Further emitter analysis and testing is planned.

Peelgren, M. L.↗

Space shuttle: Stability and control effectiveness at high and low angles of attack and effects of variations in engine shround, fin, and drag petal configurations for the Boeing 0.008899-scale pressure-fed ballistic recoverable booster, model 979-160

Experimental aerodynamic investigations were carried out in the Boeing transonic and supersonic wind tunnels on a 0.008899-scale model of a proposed pressure-fed ballistic recoverable booster (BRB) configuration. The purpose of the test program was to determine the stability and control effectiveness of the basic configuration at high and low angles of attack, and to conduct parametric studies of various engine shroud, fin, and drag petal configurations. Six-component force data and base pressure data were obtained over a Mach number range of 0.35 to 4.0 at angles of attack of -5 to 25 and 55 to 85 at zero degrees sideslip and over a sideslip range of -10 to +10 at angles of attack ranging from -10 to 72.5. Two-component force data were also obtained with a fin balance on selected runs.

Hanson, R. L.↗