Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FEATURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

ON THE 10 mum SILICATE FEATURE IN ACTIVE GALACTIC NUCLEI

The 10 mum silicate feature observed with Spitzer in active galactic nuclei (AGNs) reveals some puzzling behavior. It (1) has been detected in emission in type 2 sources, (2) shows broad, flat-topped emission peaks shifted toward long wavelengths in several type 1 sources, and (3) is not seen in deep absorption in any source observed so far. We solve all three puzzles with our clumpy dust radiative transfer formalism. Addressing (1), we present the spectral energy distribution (SED) of SST1721+6012, the first type 2 quasar observed to show a clear 10 mum silicate feature in emission. Such emission arises in models of the AGN torus easily when its clumpy nature is taken into account. We constructed a large database of clumpy torus models and performed extensive fitting of the observed SED. We find that the cloud radial distribution varies as r {sup -1.5} and the torus contains 2-4 clouds along radial equatorial rays, each with optical depth at visual approx60-80. The source bolometric luminosity is approx3 x 10{sup 12} L{sub sun}. Our modeling suggests that approx<35% of objects with tori sharing these characteristics and geometry would have their central engines obscured. This relatively low obscuration probability can explain the clear appearance of the 10 mum emission feature in SST1721+6012 together with its rarity among other QSO2. Investigating (2), we also fitted the SED of PG1211+143, one of the first type 1 QSOs with a 10 mum silicate feature detected in emission. Together with other similar sources, this QSO appears to display an unusually broadened feature whose peak is shifted toward longer wavelengths. Although this led to suggestions of non-standard dust chemistry in these sources, our analysis fits such SEDs with standard galactic dust; the apparent peak shifts arise from simple radiative transfer effects. Regarding (3), we find additionally that the distribution of silicate feature strengths among clumpy torus models closely resembles the observed distribution, and the feature never occurs deeply absorbed. Comparing such distributions in several AGN samples we also show that the silicate emission feature becomes stronger in the transition from Seyfert to quasar luminosities.

79 ASTRONOMY AND ASTROPHYSICS↗

IMAGING SPECTROPOLARIMETRY WITH IBIS. II. ON THE FINE STRUCTURE OF G-BAND BRIGHT FEATURES

We present new results from first observations of the quiet solar photosphere performed through the Interferometric BIdimensional Spectrometer (IBIS) in spectropolarimetric mode. IBIS allowed us to measure the four Stokes parameters in the Fe I 630.15 nm and Fe I 630.25 nm lines with high spatial and spectral resolutions for 53 minutes; the polarimetric sensitivity achieved by the instrument is 3 x 10{sup -3} the continuum intensity level. We focus on the correlation which emerges between the G-band bright feature brightness and magnetic filling factor of {approx}10{sup 3} G (kG) fields derived by inverting the Stokes I and V profiles. In more detail, we present the correlation first in a pixel-by-pixel study of a {approx_equal}3'' wide bright feature (a small network patch) and then we show that such a result can be extended to all the bright features found in the data set at any instant of the time sequence. The higher the kilo-Gauss filling factor associated to a feature, the higher the brightness of the feature itself. Filling factors up to {approx_equal}35% are obtained for the brightest features. Considering the values of the filling factors derived from the inversion analysis of spectropolarimetric data and the brightness variation observed in the G-band data we put forward an upper limit for the smallest scale over which magnetic flux concentrations in intergranular lanes produce a G-band brightness enhancement ({approx_equal}0.''1). Moreover, the brightness saturation observed for feature sizes comparable to the resolution of the observations is compatible with the large G-band bright features being clusters of sub-arcsecond bright points. This conclusion deserves to be confirmed by forthcoming spectropolarimetric observations at higher spatial resolution.

79 ASTRONOMY AND ASTROPHYSICS↗

IDENTIFICATION OF THREE NEW PROTOPLANETARY NEBULAE EXHIBITING THE UNIDENTIFIED FEATURE AT 21 {mu}m

Among its great findings, the Infrared Astronomical Satellite mission showed the existence of an unidentified mid-IR feature around 21 {mu}m. Since its discovery, this feature has been detected in all C-rich protoplanetary nebulae (PPNe) of intermediate spectral type (F-G) and-weakly-in a few PNe and asymptotic giant branch (AGB) stars, but the nature of its carriers remains unknown. In this paper, we show the detection of this feature in the spectra of three new stars transiting from the AGB to the PN stage obtained with the Spitzer Space Telescope. Following a recent suggestion, we try to model the spectral energy distributions of our targets with amorphous carbon and FeO, which might be responsible for the unidentified feature. The fit thus obtained is not completely satisfactory, since the shape of the feature is not well matched. In an attempt to relate the unidentified feature to other dust features, we retrieved mid-IR spectra of all 21 {mu}m sources currently known from Infrared Space Observatory and Spitzer online archives and noticed a correlation between the flux emitted in the 21 {mu}m feature and that emitted at 7 and 11 {mu}m (polycyclic aromatic hydrocarbon bands and hydrogenated amorphous carbon broad emission). Such a correlation may point to a common nature of the carriers.

79 ASTRONOMY AND ASTROPHYSICS↗

A complete census of silicate features in the mid-infrared spectra of active galaxies

We present a comprehensive study of the silicate features at 9.7 and 18 μm of a sample of almost 800 active galactic nuclei (AGNs) with available spectra from the Spitzer InfraRed Spectrograph (IRS). We measure the strength of the silicate feature at 9.7 μm, S {sub 9.7}, before and after subtracting the host galaxy emission from the IRS spectra. The number of type 1 and 2 AGNs with the feature in emission increases by 20 and 50%, respectively, once the host galaxy is removed, while 35% of objects with this feature originally in absorption exhibit it in even deeper absorption. The peak of S {sub 9.7}, λ{sub peak}, has a bimodal distribution when the feature is in emission, with about 65% of the cases showing λ{sub peak}>10.2 μm. Silicates can appear in emission in objects with mid-infrared (MIR) luminosity spanning over six orders of magnitude. The derived distributions of the strength of the silicate features at 9.7 and 18 μm provide a solid test bed for modeling the dust distribution in AGNs. Clumpiness is needed in order to produce absorption features in unobscured AGNs and can also cause the silicates to be in absorption at 9.7 μm and in emission at 18 μm in type 1 sources. We find the “cosmic” silicates of Ossenkopf et al. to be more consistent with the observations than Draine's “astronomical” silicates. Finally, we discuss the possibility of a foreground absorber to explain the deep silicate absorption features in the MIR spectra of some type 2 AGNs.

79 ASTRONOMY AND ASTROPHYSICS↗

The effective field theory of inflation models with sharp features

We describe models of single-field inflation with small and sharp step features in the potential (and sound speed) of the inflaton field, in the context of the Effective Field Theory of Inflation. This approach allows us to study the effects of features in the power-spectrum and in the bispectrum of curvature perturbations, from a model-independent point of view, by parametrizing the features directly with modified ''slow-roll'' parameters. We can obtain a self-consistent power-spectrum, together with enhanced non-Gaussianity, which grows with a quantity β that parametrizes the sharpness of the step. With this treatment it is straightforward to generalize and include features in other coefficients of the effective action of the inflaton field fluctuations. Our conclusion in this case is that, excluding extrinsic curvature terms, the only interesting effects at the level of the bispectrum could arise from features in the first slow-roll parameter ε or in the speed of sound c{sub s}. Finally, we derive an upper bound on the parameter β from the consistency of the perturbative expansion of the action for inflaton perturbations. This constraint can be used for an estimation of the signal-to-noise ratio, to show that the observable which is most sensitive to features is the power-spectrum. This conclusion would change if we consider the contemporary presence of a feature and a speed of sound c{sub s} < 1, as, in such a case, contributions from an oscillating folded configuration can potentially make the bispectrum the leading observable for feature models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The future of primordial features with 21 cm tomography

Detecting a deviation from a featureless primordial power spectrum of fluctuations would give profound insight into the physics of the primordial Universe. Depending on their nature, primordial features can either provide direct evidence for the inflation scenario or pin down details of the inflation model. Thus far, using the cosmic microwave background (CMB) we have only been able to put stringent constraints on the amplitude of features, but no significant evidence has been found for such signals. Here we explore the limit of the experimental reach in constraining such features using 21 cm tomography at high redshift. A measurement of the 21 cm power spectrum from the Dark Ages is generally considered as the ideal experiment for early Universe physics, with potentially access to a large number of modes. We consider three different categories of theoretically motivated models: the sharp feature models, resonance models, and standard clock models. We study the improvements on bounds on features as a function of the total number of observed modes and identify parameter degeneracies. The detectability depends critically on the amplitude, frequency and scale-location of the features, as well as the angular and redshift resolution of the experiment. We quantify these effects by considering different fiducial models. Our forecast shows that a cosmic variance limited 21 cm experiment measuring fluctuations in the redshift range 30 ≤ z ≤ 100 with a 0.01-MHz bandwidth and sub-arcminute angular resolution could potentially improve bounds by several orders of magnitude for most features compared to current Planck bounds. At the same time, 21 cm tomography also opens up a unique window into features that are located on very small scales.

79 ASTRONOMY AND ASTROPHYSICS↗

CMB polarization features from inflation versus reionization

The angular power spectrum of the cosmic microwave background temperature anisotropy observed by WMAP has an anomalous dip at l{approx}20 and a bump at l{approx}40. One explanation for this structure is the presence of features in the primordial curvature power spectrum, possibly caused by a step in the inflationary potential. The detection of these features is only marginally significant from temperature data alone. However, the inflationary feature hypothesis predicts a specific shape for the E-mode polarization power spectrum with a structure similar to that observed in temperature at l{approx}20-40. Measurement of the CMB polarization on few-degree scales can therefore be used as a consistency check of the hypothesis. The Planck satellite has the statistical sensitivity to confirm or rule out the model that best fits the temperature features with 3{sigma} significance, assuming all other parameters are known. With a cosmic variance limited experiment, this significance improves to 8{sigma}. For tests of inflationary models that can explain both the dip and the bump in temperature, the primary source of uncertainty is confusion with polarization features created by a complex reionization history, which, at most, reduces the significance to 2.5{sigma} for Planck and 5{sigma}-6{sigma} for an ideal experiment. Smoothing of the polarization spectrum by a large tensor component only slightly reduces the ability of polarization to test for inflationary features, as does requiring that polarization is consistent with the observed temperature spectrum, given the expected low level of TE correlation on few-degree scales. If polarized foregrounds can be adequately subtracted, Planck will supply valuable evidence for or against features in the primordial power spectrum. A future high-sensitivity polarization satellite would enable a decisive test of the feature hypothesis and provide complementary information about the shape of a possible step in the inflationary potential.

79 ASTRONOMY AND ASTROPHYSICS↗

ASDFL: An adaptive super‐pixel discriminative feature‐selective learning for vehicle matching

Abstract There are a large number of cameras in modern transportation system that capture numerous vehicle images continuously. Therefore, automatic analysis of these vehicle images is helpful for traffic flow management, criminal investigations and vehicle inspections. Vehicle matching, which aims to determine whether two input images depict an identical vehicle, is one of the core tasks in vehicle analysis. Recent relevant studies have focused on local feature extraction instead of global extraction, since local details can provide crucial cues to distinguish between cars. However, these methods do not select local features; that is, they do not assign weights to local features. Therefore, in this research, we systematically study the vehicle matching task, and present a novel annotation‐free local‐based deep learning method called Adaptive super‐pixel discriminative feature‐selective learning (ASDFL) to address this issue. In ASDFL, vehicle images are segmented into clusters of super‐pixels of similar size by considering the location and colour similarities of pixels without using any component‐level annotation. These super‐pixels are deemed to be the virtual components of vehicles. Moreover, a convolutional neural network is used to extract the deep features of these virtual components. Thereafter, an instance‐specific mask generation module driven by the extracted global features is enhanced to produce a mask to select the most distinctive virtual components of each vehicle image pair in the feature space. Finally, the vehicle matching task is accomplished by classifying the selected virtual component features of each imaged vehicle pair. Extensive experiments on two popular vehicle identification benchmarks demonstrate that our method is 1.57% and 0.8% more accurate than the previous baselines in a vehicle matching task on the VeRi and VehicleID datasets, respectively, which demonstrates the effectiveness of our method.

Qin, Rong↗

Correlative feature analysis on FFDM

Identifying the corresponding images of a lesion in different views is an essential step in improving the diagnostic ability of both radiologists and computer-aided diagnosis (CAD) systems. Because of the nonrigidity of the breasts and the 2D projective property of mammograms, this task is not trivial. In this pilot study, we present a computerized framework that differentiates between corresponding images of the same lesion in different views and noncorresponding images, i.e., images of different lesions. A dual-stage segmentation method, which employs an initial radial gradient index (RGI) based segmentation and an active contour model, is applied to extract mass lesions from the surrounding parenchyma. Then various lesion features are automatically extracted from each of the two views of each lesion to quantify the characteristics of density, size, texture and the neighborhood of the lesion, as well as its distance to the nipple. A two-step scheme is employed to estimate the probability that the two lesion images from different mammographic views are of the same physical lesion. In the first step, a correspondence metric for each pairwise feature is estimated by a Bayesian artificial neural network (BANN). Then, these pairwise correspondence metrics are combined using another BANN to yield an overall probability of correspondence. Receiver operating characteristic (ROC) analysis was used to evaluate the performance of the individual features and the selected feature subset in the task of distinguishing corresponding pairs from noncorresponding pairs. Using a FFDM database with 123 corresponding image pairs and 82 noncorresponding pairs, the distance feature yielded an area under the ROC curve (AUC) of 0.81{+-}0.02 with leave-one-out (by physical lesion) evaluation, and the feature metric subset, which included distance, gradient texture, and ROI-based correlation, yielded an AUC of 0.87{+-}0.02. The improvement by using multiple feature metrics was statistically significant compared to single feature performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image features for misalignment correction in medical flat-detector CT

Purpose: Misalignment artifacts are a serious problem in medical flat-detector computed tomography. Generally, the geometrical parameters, which are essential for reconstruction, are provided by preceding calibration routines. These procedures are time consuming and the later use of stored parameters is sensitive toward external impacts or patient movement. The method of choice in a clinical environment would be a markerless online-calibration procedure that allows flexible scan trajectories and simultaneously corrects misalignment and motion artifacts during the reconstruction process. Therefore, different image features were evaluated according to their capability of quantifying misalignment. Methods: Projections of the FORBILD head and thorax phantoms were simulated. Additionally, acquisitions of a head phantom and patient data were used for evaluation. For the reconstruction different sources and magnitudes of misalignment were introduced in the geometry description. The resulting volumes were analyzed by entropy (based on the gray-level histogram), total variation, Gabor filter texture features, Haralick co-occurrence features, and Tamura texture features. The feature results were compared to the back-projection mismatch of the disturbed geometry. Results: The evaluations demonstrate the ability of several well-established image features to classify misalignment. The authors elaborated the particular suitability of the gray-level histogram-based entropy on identifying misalignment artifacts, after applying an appropriate window level (bone window). Conclusions: Some of the proposed feature extraction algorithms show a strong correlation with the misalignment level. Especially, entropy-based methods showed very good correspondence, with the best of these being the type that uses the gray-level histogram for calculation. This makes it a suitable image feature for online-calibration.

60 APPLIED LIFE SCIENCES↗

SU-E-J-206: A Comparison of Different Hardware Design Approaches for Feature-Supported Optical Head-Tracking with Respect to Angular Dependencies

Purpose: Recent research has shown that optical features significantly improve marker-less optical head-tracking for cranial radiotherapy. Simulations, however, showed that these optical features, which are used to derive tissue thickness, depend on the incident angle of the IR scanning laser beam and the perspective of the camera analyzing the reflective patterns. We present an experimental analysis determining which is the most robust optical setup concerning angular influences. Methods: In three consecutive experiments, the incident angle of the laser (1), the perspective of the camera (2) or both simultaneously (3, ‘inBeam’-perspective) were changed with respect to the target. We analyzed how this affects feature intensity. These intensities were determined from seven concentric regions of interest (ROIs) around the laser spot. Two targets were used: a tissue-like silicone phantom and a human's forehead. Results: For each experiment, the feature intensity generally decreases with increasing angle. We found that the optical properties of the silicone phantom do not fit the properties of human skin. Furthermore, the angular influence of the laser on the features is significantly higher than the perspective of the camera. With the ‘inBeam’- perspective, the smoothest decays of feature intensity were found. We suppose that this is because of a fixed relationship between both devices. This smoothness, suggesting a predictable functional relationship, may simplify angle compensation for machine learning algorithms. This is particularly prominent for the medial ROIs. The inner ROIs highly depend on the angle and power of the laser. The outer ROIs show less angular dependency but the signal strength is critically low and prone to artifacts. Therefore and because of the smooth decays, medial ROIs are a suitable tradeoff between susceptibility, signal-noise-ratio and distance to the center of the laser spot. Conclusion: For tissue thickness correlated feature acquisition, the medial ROIs with the ‘inBeam’-setup provide most valuable features This work was supported by Varian Medical Systems Inc. (Palo Alto, CA, USA). In addition, this work was supported by the Graduate School for Computing in Medicine and Life Sciences funded by Germany's Excellence Initiative [DFG GSC 235/1].

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-A-12A-04: Quantitative Texture Features Calculated in Lung Tissue From CT Scans Demonstrate Consistency Between Two Databases From Different Institutions

Purpose: To evaluate the consistency of computed tomography (CT) scan texture features, previously identified as stable in a healthy patient cohort, in esophageal cancer patient CT scans. Methods: 116 patients receiving radiation therapy (median dose: 50.4Gy) for esophageal cancer were retrospectively identified. For each patient, diagnostic-quality pre-therapy (0-183 days) and post-therapy (5-120 days) scans (mean voxel size: 0.8mm×0.8mm×2.5mm) and a treatment planning scan and associated dose map were collected. An average of 501 32x32-pixel ROIs were placed randomly in the lungs of each pre-therapy scan. ROI centers were mapped to corresponding locations in post-therapy and planning scans using the displacement vector field output by demons deformable registration. Only ROIs with mean dose <5Gy were analyzed, as these were expected to contain minimal post-treatment damage. 140 texture features were calculated in pre-therapy and post-therapy scan ROIs and compared using Bland-Altman analysis. For each feature, the mean feature value change and the distance spanned by the 95% limits of agreement were normalized to the mean feature value, yielding normalized range of agreement (nRoA) and normalized bias (nBias). Using Wilcoxon signed rank tests, nRoA and nBias were compared with values computed previously in 27 healthy patient scans (mean voxel size: 0.67mm×0.67mm×1mm) acquired at a different institution. Results: nRoA was significantly (p<0.001) larger in cancer patients than healthy patients. Differences in nBias were not significant (p=0.23). The 20 features identified previously as having nRoA<20% for healthy patients had the lowest nRoA values in the current database, with an average increase of 5.6%. Conclusion: Despite differences in CT scanner type, scan resolution, and patient health status, the same 20 features remained stable (i.e., low variability and bias) in the absence of disease changes for databases from two institutions. Identification of these features is the first step towards quantifying radiation-induced changes between preand post-therapy scans. Supported, in part, by NIH Grant Nos. S10 RR021039, and P30 CA14599, the Virginia and D. K. Ludwig Fund for Cancer Research, Imaging Research Institute, Biological Sciences Division, The University of Chicago, and The Institute for Translational Medicine Pilot Award, The University of Chicago.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRA-10: Prognostic Value of Intra-Radiation Treatment FDG-PET and CT Imaging Features in Locally Advanced Head and Neck Cancer

Purpose: To predict response to radiation treatment using computational FDG-PET and CT images in locally advanced head and neck cancer (HNC). Methods: 68 patients with State III-IVB HNC treated with chemoradiation were included in this retrospective study. For each patient, we analyzed primary tumor and lymph nodes on PET and CT scans acquired both prior to and during radiation treatment, which led to 8 combinations of image datasets. From each image set, we extracted high-throughput, radiomic features of the following types: statistical, morphological, textural, histogram, and wavelet, resulting in a total of 437 features. We then performed unsupervised redundancy removal and stability test on these features. To avoid over-fitting, we trained a logistic regression model with simultaneous feature selection based on least absolute shrinkage and selection operator (LASSO). To objectively evaluate the prediction ability, we performed 5-fold cross validation (CV) with 50 random repeats of stratified bootstrapping. Feature selection and model training was solely conducted on the training set and independently validated on the holdout test set. Receiver operating characteristic (ROC) curve of the pooled Result and the area under the ROC curve (AUC) was calculated as figure of merit. Results: For predicting local-regional recurrence, our model built on pre-treatment PET of lymph nodes achieved the best performance (AUC=0.762) on 5-fold CV, which compared favorably with node volume and SUVmax (AUC=0.704 and 0.449, p<0.001). Wavelet coefficients turned out to be the most predictive features. Prediction of distant recurrence showed a similar trend, in which pre-treatment PET features of lymph nodes had the highest AUC of 0.705. Conclusion: The radiomics approach identified novel imaging features that are predictive to radiation treatment response. If prospectively validated in larger cohorts, they could aid in risk-adaptive treatment of HNC.

60 APPLIED LIFE SCIENCES↗

TU-CD-BRB-07: Identification of Associations Between Radiologist-Annotated Imaging Features and Genomic Alterations in Breast Invasive Carcinoma, a TCGA Phenotype Research Group Study

Purpose: To determine associations between radiologist-annotated MRI features and genomic measurements in breast invasive carcinoma (BRCA) from the Cancer Genome Atlas (TCGA). Methods: 98 TCGA patients with BRCA were assessed by a panel of radiologists (TCGA Breast Phenotype Research Group) based on a variety of mass and non-mass features according to the Breast Imaging Reporting and Data System (BI-RADS). Batch corrected gene expression data was obtained from the TCGA Data Portal. The Kruskal-Wallis test was used to assess correlations between categorical image features and tumor-derived genomic features (such as gene pathway activity, copy number and mutation characteristics). Image-derived features were also correlated with estrogen receptor (ER), progesterone receptor (PR), and human epidermal growth factor receptor 2 (HER2/neu) status. Multiple hypothesis correction was done using Benjamini-Hochberg FDR. Associations at an FDR of 0.1 were selected for interpretation. Results: ER status was associated with rim enhancement and peritumoral edema. PR status was associated with internal enhancement. Several components of the PI3K/Akt pathway were associated with rim enhancement as well as heterogeneity. In addition, several components of cell cycle regulation and cell division were associated with imaging characteristics.TP53 and GATA3 mutations were associated with lesion size. MRI features associated with TP53 mutation status were rim enhancement and peritumoral edema. Rim enhancement was associated with activity of RB1, PIK3R1, MAP3K1, AKT1,PI3K, and PIK3CA. Margin status was associated with HIF1A/ARNT, Ras/ GTP/PI3K, KRAS, and GADD45A. Axillary lymphadenopathy was associated with RB1 and BCL2L1. Peritumoral edema was associated with Aurora A/GADD45A, BCL2L1, CCNE1, and FOXA1. Heterogeneous internal nonmass enhancement was associated with EGFR, PI3K, AKT1, HF/MET, and EGFR/Erbb4/neuregulin 1. Diffuse nonmass enhancement was associated with HGF/MET/MUC20/SHIP, and HGF/MET/RANBP9. Linear nonmass enhancement was associated with PIK3R1 and AKT activity. Conclusion: MRI-genomic association analysis revealed that several BRCA-associated gene features were associated with radiologist-annotated image features.

60 APPLIED LIFE SCIENCES↗

TU-CD-BRB-10: 18F-FDG PET Image-Derived Tumor Features Highlight Altered Pathways Identified by Trancriptomic Analysis in Head and Neck Cancer

Purpose: Several quantitative features can be extracted from 18F-FDG PET images, such as standardized uptake values (SUVs), metabolic tumor volume (MTV), shape characterization (SC) or intra-tumor radiotracer heterogeneity quantification (HQ). Some of these features calculated from baseline 18F-FDG PET images have shown a prognostic and predictive clinical value. It has been hypothesized that these features highlight underlying tumor patho-physiological processes at smaller scales. The objective of this study was to investigate the ability of recovering alterations of signaling pathways from FDG PET image-derived features. Methods: 52 patients were prospectively recruited from two medical centers (Brest and Poitiers). All patients underwent an FDG PET scan for staging and biopsies of both healthy and primary tumor tissues. Biopsies went through a transcriptomic analysis performed in four spates on 4×44k chips (Agilent™). Primary tumors were delineated in the PET images using the Fuzzy Locally Adaptive Bayesian algorithm and characterized using 10 features including SUVs, SC and HQ. A module network algorithm followed by functional annotation was exploited in order to link PET features with signaling pathways alterations. Results: Several PET-derived features were found to discriminate differentially expressed genes between tumor and healthy tissue (fold-change >2, p<0.01) into 30 co-regulated groups (p<0.05). Functional annotations applied to these groups of genes highlighted associations with well-known pathways involved in cancer processes, such as cell proliferation and apoptosis, as well as with more specific ones such as unsaturated fatty acids. Conclusion: Quantitative features extracted from baseline 18F-FDG PET images usually exploited only for diagnosis and staging, were identified in this work as being related to specific altered pathways and may show promise as tools for personalizing treatment decisions.

60 APPLIED LIFE SCIENCES↗

WE-AB-204-04: Feature Selection and Clustering Optimization for Pseudo-CT Generation in MR-Based Attenuation Correction and Radiation Therapy Planning

Purpose: Accurate and robust photon attenuation derived from MR is essential for PET/MR and MR-based radiation treatment planning applications. Although the fuzzy C-means (FCM) algorithm has been applied for pseudo-CT generation, the input feature combination and the number of clusters have not been optimized. This study aims to optimize both for clinically practical pseudo-CT generation. Methods: Nine volunteers were recruited. A 190-second, single-acquisition UTE-mDixon with 25% (angular) sampling and 3D radial readout was performed to acquire three primitive MR features at TEs of 0.1, 1.5, and 2.8 ms: the free-induction-decay (FID), the first and the second echo images. Three derived images, Dixon-fat and Dixon-water generated by two-point Dixon water/fat separation, and R2* (1/T2*) map, were also created. To identify informative inputs for generating a pseudo-CT image volume, all 63 combinations, choosing one to six of the feature images, were used as inputs to FCM for pseudo-CT generation. Further, the number of clusters was varied from four to seven to find the optimal approach. Mean prediction deviation (MPD), mean absolute prediction deviation (MAPD), and correlation coefficient (R) of different combinations were compared for feature selection. Results: Among the 63 feature combinations, the four that resulted in the best MAPD and R were further compared along with the set containing all six features. The results suggested that R2* and Dixon-water are the most informative features. Further, including FID also improved the performance of pseudo-CT generation. Consequently, the set containing FID, Dixon-water, and R2* resulted in the most accurate, robust pseudo-CT when the number of cluster equals to five (5C). The clusters were interpreted as air, fat, bone, brain, and fluid. The six-cluster Result additionally included bone marrow. Conclusion: The results suggested that FID, Dixon-water, R2* are the most important features. The findings can be used to facilitate pseudo-CT generation for unsupervised clustering. Please note that the project was completed with partial funding from the Ohio Department of Development grant TECH 11-063 and a sponsored research agreement with Philips Healthcare that is managed by Case Western Reserve University. As noted in the affiliations, some of the authors are Philips employees.

60 APPLIED LIFE SCIENCES↗

Computer-aided breast MR image feature analysis for prediction of tumor response to chemotherapy

Purpose: To identify a new clinical marker based on quantitative kinetic image features analysis and assess its feasibility to predict tumor response to neoadjuvant chemotherapy. Methods: The authors assembled a dataset involving breast MR images acquired from 68 cancer patients before undergoing neoadjuvant chemotherapy. Among them, 25 patients had complete response (CR) and 43 had partial and nonresponse (NR) to chemotherapy based on the response evaluation criteria in solid tumors. The authors developed a computer-aided detection scheme to segment breast areas and tumors depicted on the breast MR images and computed a total of 39 kinetic image features from both tumor and background parenchymal enhancement regions. The authors then applied and tested two approaches to classify between CR and NR cases. The first one analyzed each individual feature and applied a simple feature fusion method that combines classification results from multiple features. The second approach tested an attribute selected classifier that integrates an artificial neural network (ANN) with a wrapper subset evaluator, which was optimized using a leave-one-case-out validation method. Results: In the pool of 39 features, 10 yielded relatively higher classification performance with the areas under receiver operating characteristic curves (AUCs) ranging from 0.61 to 0.78 to classify between CR and NR cases. Using a feature fusion method, the maximum AUC = 0.85 ± 0.05. Using the ANN-based classifier, AUC value significantly increased to 0.96 ± 0.03 (p < 0.01). Conclusions: This study demonstrated that quantitative analysis of kinetic image features computed from breast MR images acquired prechemotherapy has potential to generate a useful clinical marker in predicting tumor response to chemotherapy.

60 APPLIED LIFE SCIENCES↗

SU-D-202-02: Quantitative Imaging: Correlation Between Image Feature Analysis and the Accuracy of Manually Drawn Contours On PET Images

Purpose: To evaluate the correlation between image features and the accuracy of manually drawn target contours on synthetic PET images Methods: A digital PET phantom was used in combination with Monte Carlo simulation to create a set of 26 simulated PET images featuring a variety of tumor shapes and activity heterogeneity. These tumor volumes were used as a gold standard in comparisons with manual contours delineated by 10 radiation oncologist on the simulated PET images. Metrics used to evaluate segmentation accuracy included the dice coefficient, false positive dice, false negative dice, symmetric mean absolute surface distance, and absolute volumetric difference. Image features extracted from the simulated tumors consisted of volume, shape complexity, mean curvature, and intensity contrast along with five texture features derived from the gray-level neighborhood difference matrices including contrast, coarseness, busyness, strength, and complexity. Correlation between these features and contouring accuracy were examined. Results: Contour accuracy was reasonably well correlated with a variety of image features. Dice coefficient ranged from 0.7 to 0.90 and was correlated closely with contrast (r=0.43, p=0.02) and complexity (r=0.5, p<0.001). False negative dice ranged from 0.10 to 0.50 and was correlated closely with contrast (r=0.68, p<0.001) and complexity (r=0.66, p<0.001). Absolute volumetric difference ranged from 0.0002 to 0.67 and was correlated closely with coarseness (r=0.46, p=0.02) and complexity (r=0.49, p=0.008). Symmetric mean absolute difference ranged from 0.02 to 1 and was correlated closely with mean curvature (r=0.57, p=0.02) and contrast (r=0.6, p=0.001). Conclusion: The long term goal of this study is to assess whether contouring variability can be reduced by providing feedback to the practitioner based on image feature analysis. The results are encouraging and will be used to develop a statistical model which will enable a prediction of contour accuracy based purely on image feature analysis.

60 APPLIED LIFE SCIENCES↗