Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Exercise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Blind Benchmark Exercise for Spent Nuclear Fuel Decay Heat

The decay heat rate of five spent nuclear fuel assemblies of the pressurized water reactor type were measured by calorimetry at the interim storage for spent nuclear fuel in Sweden. Calculations of the decay heat rate of the five assemblies were performed by 20 organizations using different codes and nuclear data libraries resulting in 31 results for each assembly, spanning most of the current state-of-the-art practice. The calculations were based on a selected subset of information, such as reactor operating history and fuel assembly properties. The relative difference between the measured and average calculated decay heat rate ranged from 0.6% to 3.3% for the five assemblies. The standard deviation of these relative differences ranged from 1.9% to 2.4%.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An international model validation exercise on radionuclide transfer and doses to freshwater biota.

Under the International Atomic Energy Agency (IAEA)'s EMRAS (Environmental Modelling for Radiation Safety) program, activity concentrations of {sup 60}Co, {sup 90}Sr, {sup 137}Cs and {sup 3}H in Perch Lake at Atomic Energy of Canada Limited's Chalk River Laboratories site were predicted, in freshwater primary producers, invertebrates, fishes, herpetofauna and mammals using eleven modelling approaches. Comparison of predicted radionuclide concentrations in the different species types with measured values highlighted a number of areas where additional work and understanding is required to improve the predictions of radionuclide transfer. For some species, the differences could be explained by ecological factors such as trophic level or the influence of stable analogues. Model predictions were relatively poor for mammalian species and herpetofauna compared with measured values, partly due to a lack of relevant data. In addition, concentration ratios are sometimes under-predicted when derived from experiments performed under controlled laboratory conditions representative of conditions in other water bodies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Assessment of doses in contaminated urban areas: modelling exercise based on Fukushima data

State-of-the-art dose assessment models were applied to estimate doses to the population in urban areas contaminated by the Fukushima Daiichi Nuclear Power Plant accident. Assessment results were compared among five models, and comparisons of model predictions with actual measurements were also made. Assessments were performed using both probabilistic and deterministic approaches. Predicted dose distributions for indoor and outdoor workers from a probabilistic approach were in good agreement with the actual measurements. In addition, when the models were applied to assess the doses to the representative person, based on a concept recommended by the International Commission on Radiological Protection and in the International Atomic Energy Agency Safety Standards, it was evident that doses to the representative person obtained with a deterministic approach were always higher than those obtained with a probabilistic approach using the same model.

dose assessment↗

GenomeTrakr proficiency testing for foodborne pathogen surveillance: an exercise from 2015

Pathogen monitoring is becoming more precise as sequencing technologies become more affordable and accessible worldwide. This transition is especially apparent in the field of food safety, which has demonstrated how whole-genome sequencing (WGS) can be used on a global scale to protect public health. GenomeTrakr coordinates the WGS performed by public-health agencies and other partners by providing a public database with real-time cluster analysis for foodborne pathogen surveillance. Because WGS is being used to support enforcement decisions, it is essential to have confidence in the quality of the data being used and the downstream data analyses that guide these decisions. Routine proficiency tests, such as the one described here, have an important role in ensuring the validity of both data and procedures. In 2015, the GenomeTrakr proficiency test distributed eight isolates of common foodborne pathogens to participating laboratories, who were required to follow a specific protocol for performing WGS. Resulting sequence data were evaluated for several metrics, including proper labelling, sequence quality and new single nucleotide polymorphisms (SNPs). Illumina MiSeq sequence data collected for the same set of strains across 21 different laboratories exhibited high reproducibility, while revealing a narrow range of technical and biological variance. The numbers of SNPs reported for sequencing runs of the same isolates across multiple laboratories support the robustness of our cluster analysis pipeline in that each individual isolate cultured and resequenced multiple times in multiple places are all easily identifiable as originating from the same source.

59 BASIC BIOLOGICAL SCIENCES↗

Measurement of stray radiation within a scanning proton therapy facility: EURADOS WG9 intercomparison exercise of active dosimetry systems

Purpose: To characterize stray radiation around the target volume in scanning proton therapy and study the performance of active neutron monitors. Methods: Working Group 9 of the European Radiation Dosimetry Group (EURADOS WG9—Radiation protection in medicine) carried out a large measurement campaign at the Trento Centro di Protonterapia (Trento, Italy) in order to determine the neutron spectra near the patient using two extended-range Bonner sphere spectrometry (BSS) systems. In addition, the work focused on acknowledging the performance of different commercial active dosimetry systems when measuring neutron ambient dose equivalents, H{sup ∗}(10), at several positions inside (8 positions) and outside (3 positions) the treatment room. Detectors included three TEPCs—tissue equivalent proportional counters (Hawk type from Far West Technology, Inc.) and six rem-counters (WENDI-II, LB 6411, RadEye™ NL, a regular and an extended-range NM2B). Meanwhile, the photon component of stray radiation was deduced from the low-lineal energy transfer part of TEPC spectra or measured using a Thermo Scientific™ FH-40G survey meter. Experiments involved a water tank phantom (60 × 30 × 30 cm{sup 3}) representing the patient that was uniformly irradiated using a 3 mm spot diameter proton pencil beam with 10 cm modulation width, 19.95 cm distal beam range, and 10 × 10 cm{sup 2} field size. Results: Neutron spectrometry around the target volume showed two main components at the thermal and fast energy ranges. The study also revealed the large dependence of the energy distribution of neutrons, and consequently of out-of-field doses, on the primary beam direction (directional emission of intranuclear cascade neutrons) and energy (spectral composition of secondary neutrons). In addition, neutron mapping within the facility was conducted and showed the highest H{sup ∗}(10) value of ∼51 μSv Gy{sup −1}; this was measured at 1.15 m along the beam axis. H{sup ∗}(10) values significantly decreased with distance and angular position with respect to beam axis falling below 2 nSv Gy{sup −1} at the entrance of the maze, at the door outside the room and below detection limit in the gantry control room, and at an adjacent room (<0.1 nSv Gy{sup −1}). Finally, the agreement on H{sup ∗}(10) values between all detectors showed a direct dependence on neutron spectra at the measurement position. While conventional rem-counters (LB 6411, RadEye™ NL, NM2-458) underestimated the H{sup ∗}(10) by up to a factor of 4, Hawk TEPCs and the WENDI-II range-extended detector were found to have good performance (within 20%) even at the highest neutron fluence and energy range. Meanwhile, secondary photon dose equivalents were found to be up to five times lower than neutrons; remaining nonetheless of concern to the patient. Conclusions: Extended-range BSS, TEPCs, and the WENDI-II enable accurate measurements of stray neutrons while other rem-counters are not appropriate considering the high-energy range of neutrons involved in proton therapy.

07 ISOTOPE AND RADIATION SOURCES↗

Endurance Exercise Performance Is Reduced after 6-h Dives at 1.35 ATA When Breathing 100% Oxygen Compared with Air

ABSTRACT Introduction Long-duration dives on consecutive days reduces muscular performance, potentially affecting military personnel. However, a paucity of data exists on how breathing gases affect endurance performance. This study examined the influence of long-duration diving with different breathing gases on aerobic endurance and handgrip performance. Methods Twenty-three military divers completed a single 6-h dive (single dive [SD]) and five 6-h dives over consecutive days (dive week [DW]) with 30-min cycling intervals using air (AIR,n= 13) or 100% oxygen (OXY,n= 10). Before and after SD and DW, subjects completed a maximum handgrip strength test, a handgrip endurance test at 40% maximal strength, and a time to exhaustion run. Results Handgrip endurance decreased after DW in OXY (SD, 1.9 ± 0.0 vs 1.4 ± 0.3 min) compared with AIR (1.8 ± 0.0 vs 1.8 ± 0.2 min) (P< 0.001). Run time decreased after SD (Pre, 20.7 ± 10.4 min; Post, 16.6 ± 7.6 min;P= 0.039) and DW (Pre, 21.6 ± 9.0 min; Post, 11.2 ± 4.0 min;P< 0.001) in OXY and after overall diving in AIR (Pre, 26.5 ± 10.2 min; Post, 22.3 ± 7.5 min;P= 0.025). V̇O 2 decreased after diving only in AIR (Pre, 42.6 ± 3.4 mL·kg −1 ⋅min −1 ; Post, 40.4 ± 3.7 mL·kg −1 ⋅min −1 ;P= 0.010). There were no other significant effects. Conclusions Breathing 100% oxygen during long-duration dives on consecutive days may exacerbate decreases in aerobic endurance and impairs handgrip endurance compared with air. Additional research is needed to elucidate mechanisms of action and possible mitigation strategies.

Sport Sciences↗

False Indications of Dose-Response Nonlinearity in Large Epidemiologic Cancer Radiation Cohort Studies; A Simulation Exercise

This study explores the likely prevalence of false indications of dose-response nonlinearity in large epidemiologic cancer radiation cohort studies (A-bomb survivors, INWORKS, Techa River). Reasons: Increasing numbers of tests of nonlinearity are being made in studies. Hypothesized nonlinear dose-response models have been justified to policy makers by analyses that rely in part on isolated findings that could be statistical fluctuations. After removing dose nonlinearity (linearization) by adjusting person-years of observation at each dose category, indications of nonlinearity, necessarily false, were counted in 5,000 randomized replications of six datasets. The average frequency of any false positive for five indicators of nonlinearity tested against a linear null was roughly 25% in Monte Carlo simulations per study, consistent with binomial calculations, increasing to ~50% within 6 studies assessed. Comparable frequencies were found using Akaike's information criterion (AIC) for model selection or multi-model averaging. False above-zero threshold doses were found more than 50% of the time, averaging to 0.05 Gy, consistent with findings in the 6 studies. Such bias, uncorrected, could distort meta-analyses of multiple studies, because meta-analyses can incorporate high P value findings. AIC-based correction for the extra threshold parameter lowered these false occurrences to 8 to 19%. Given the simulation rates, the possibility of false positives might be noted when isolated findings of nonlinearity are discussed in a regulatory context. When reporting a threshold dose with a P value > 0.05, it would be informative to note the expected high false prevalence rate due to bias.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Incorporating Full Elastodynamic Effects and Dipping Fault Geometries in Community Code Verification Exercises for Simulations of Earthquake Sequences and Aseismic Slip (SEAS)

ABSTRACT Numerical modeling of earthquake dynamics and derived insight for seismic hazard relies on credible, reproducible model results. The sequences of earthquakes and aseismic slip (SEAS) initiative has set out to facilitate community code comparisons, and verify and advance the next generation of physics-based earthquake models that reproduce all phases of the seismic cycle. With the goal of advancing SEAS models to robustly incorporate physical and geometrical complexities, here we present code comparison results from two new benchmark problems: BP1-FD considers full elastodynamic effects, and BP3-QD considers dipping fault geometries. Seven and eight modeling groups participated in BP1-FD and BP3-QD, respectively, allowing us to explore these physical ingredients across multiple codes and better understand associated numerical considerations. With new comparison metrics, we find that numerical resolution and computational domain size are critical parameters to obtain matching results. Codes for BP1-FD implement different criteria for switching between quasi-static and dynamic solvers, which require tuning to obtain matching results. In BP3-QD, proper remote boundary conditions consistent with specified rigid body translation are required to obtain matching surface displacements. With these numerical and mathematical issues resolved, we obtain excellent quantitative agreements among codes in earthquake interevent times, event moments, and coseismic slip, with reasonable agreements made in peak slip rates and rupture arrival time. We find that including full inertial effects generates events with larger slip rates and rupture speeds compared to the quasi-dynamic counterpart. For BP3-QD, both dip angle and sense of motion (thrust versus normal faulting) alter ground motion on the hanging and foot walls, and influence event patterns, with some sequences exhibiting similar-size characteristic earthquakes, and others exhibiting different-size events. These findings underscore the importance of considering full elastodynamics and nonvertical dip angles in SEAS models, as both influence short- and long-term earthquake behavior and are relevant to seismic hazard.

Geochemistry & Geophysics↗

Sandia National Laboratories results for the 2010 criticality accident dosimetry exercise, at the CALIBAN reactor, CEA Valduc France.

This document describes the personal nuclear accident dosimeter (PNAD) used by Sandia National Laboratories (SNL) and presents PNAD dosimetry results obtained during the Nuclear Accident Dosimeter Intercomparison Study held 20-23 September, 2010, at CEA Valduc, France. SNL PNADs were exposed in two separate irradiations from the CALIBAN reactor. Biases for reported neutron doses ranged from -15% to +0.4% with an average bias of -7.7%. PNADs were also exposed on the back side of phantoms to assess orientation effects.

61 RADIATION PROTECTION AND DOSIMETRY↗

SMS Software Training Exercise 101: SMS and Janam XP20 Data Entry with PSU Collectors

The LANL Sample Management System (SMS) is a software system written in JAVA that supports record keeping associated with handling of media and samples in the BioWatch program. During this portion of the class the instructor will provide: 1. A general overview of what SMS is, 2. How SMS may be configured, 3. How to launch and log-in to SMS, 4. How to accomplish data entry, 5. How to use the Tracking / Exposure History features, 6. How to use the Tracking / Data View and Edit data view features (a. Specifically cover editing a PSU Collector name).

99 GENERAL AND MISCELLANEOUS↗

Benchmarking Exercises To Validate The Updated ELLWF GoldSim Slit Trench Model

The Savannah River National Laboratory (SRNL) results of the 2008 Performance Assessment (PA) (WSRC, 2008) sensitivity/uncertainty analyses conducted for the trenches located in the EArea LowLevel Waste Facility (ELLWF) were subject to review by the United States Department of Energy (U.S. DOE) Low-Level Waste Disposal Facility Federal Review Group (LFRG) (LFRG, 2008). LFRG comments were generally approving of the use of probabilistic modeling in GoldSim to support the quantitative sensitivity analysis. A recommendation was made, however, that the probabilistic models be revised and updated to bolster their defensibility. SRS committed to addressing those comments and, in response, contracted with Neptune and Company to rewrite the three GoldSim models.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Joint IAEA/NNSA International Workshop Nuclear Forensics Methodologies for Practitioners 2013 Scenario Based Exercise – Version 4.0 Instructor’s Manual

[Participants will serve as border guards for Reimerland. They will be given brief instruction on the operation of hand-held RadioIsotope DetectorS (RIDS) and be provided an intelligence briefing that tells them to be on the lookout for suspicious activity at their post. Their instruction will include directing suspicious vehicles to a location for secondary screening. If, after secondary screening, suspicions of a criminal act involving nuclear and or radioactive materials remain, participants have been instructed to request assistance from the NLEA, who will then setup and manage a radiological crime scene. Participants will watch a demonstration of two vehicles containing radioactive materials driving through and setting off a portal monitor. The first vehicle, a semi-tractor trailer, sets off only a gamma alarm. After the driver provides a shipping manifest of fertilizer, participants, posing as border guards, are expected to waive this vehicle through inspection. The second vehicle, an SUV, set off both gamma and 2 neutron alarms. The alarming of the neutron monitor should prompt participants to set up a secondary inspection of the vehicle immediately. The driver of the vehicle indicates he is in legal possession of an industrial instrument containing an old 133Ba source that has decayed to a level no longer requiring official paperwork according to the IAEA and internationally accepted transportation regulations. Authorities have verified that the industrial source does fit the description of one that is sold commercially. However, upon setting up a secondary screening, participants will use hand-held detectors to locate several other radioactive sources emanating from a black duffle bag in the rear of the vehicle (Figure 1). Hand held detectors detect the presence of 133Ba, and Pu. Upon questioning, the driver only commits to having the 133Ba industrial source and cannot account for the detection of neutrons within his vehicle. Since neutron alarms also sounded, participants should indicate that a neutron alarm would be inconsistent with a 133Ba source alone and should therefore conclude further investigation is warranted. This will prompt participants to call in a response team from the NLEA to set up a radiological crime scene around the vehicle in question. The response team is able to shoot a 3-D X-ray radiograph of the duffle bag without moving it to ensure it is rendered safe and moveable without disturbing the contents in the field (Figure 2). At this point, the duffle bag is entered into inventory as evidence and a chain of custody form is initiated. Swipes are taken from the outer bag to confirm there is no dispersible contamination. The bag and its contents are considered valuable for the investigation by the lead investigator. He determines the duffle bag is safe to transport to RRL for evidence inventory and analysis. The duffle bag and its contents are packaged and sent off to the RRL.]

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Nuclear Security: Hypothetical Facility Exercise

The objectives of this sessions are to understand the basic function of the Hypothetical Facility; identify the different areas of the Hypothetical Facility.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗