Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Methodology for Developing the REScheckTM Software through Version 4.4.3

The Energy Policy Act of 1992 (EPAct, Public Law 102-486) establishes the 1992 Model Energy Code (MEC), published by the Council of American Building Officials (CABO), as the target for several energy-related requirements for residential buildings (CABO 1992). The U.S. Department of Housing and Urban Development (HUD) and the U.S. Department of Agriculture (via Rural Economic and Community Development [RECD] [formerly Farmers Home Administration]) are required to establish standards for government-assisted housing that “meet or exceed the requirements of the Council of American Building Officials Model Energy Code, 1992.” CABO issued 1992, 1993, and 1995 editions of the MEC (CABO 1992, 1993, and 1995).

97 MATHEMATICS AND COMPUTING↗

Developing Commercial Code Precalculated Packages

ACEEE Building Summer Study Conference paper to discuss the Developing Commercial Code Precalculated Packages as related to Building Energy codes and standards.

Commercial Code Precalculated Packages, Building E↗

ACE Learning Series - Enforcement Toolkit

The Building Energy Codes Program (BECP) developed this toolkit to help the enforcement community achieve higher levels of compliance with building energy codes. Although this toolkit is not intended for use by designers, developers, homeowners or renters, building owners, or building operators, it may provide those individuals some insight into the issues facing the enforcement community.

IECC, building information modeling, HVAC, new con↗

Total System Performance Ratio—A Systems Based Approach for Evaluating HVAC System Efficiency

The prescriptive path is the most widely used approach for commercial code compliance in the United States. Though easy to implement, prescriptive approaches do not typically discriminate between minimally compliant, high-performing and poorly performing HVAC system configurations. Hence, to meet aggressive energy and carbon reduction goals, it is clear that energy codes will need to transition from prescriptive to performance-based approaches, a transition that is riddled with several challenges. This paper discusses a new HVAC system-based performance approach (HVAC System Performance) which provides a simpler solution to HVAV system evaluation compared to whole building performance, while keeping tradeoffs limited to specific building systems. The Total System Performance Ratio (TSPR) is a metric for evaluation of overall system efficiency instead of individual component efficiency, a solution which could also eventually facilitate the transition to a 100% performance-based code structure. TSPR is a ratio that compares the annual heating and cooling load of a building to the annual energy consumed by the building’s HVAC system. A calculation software tool has been developed for determining a building’s TSPR. Already incorporated into the 2018 Washington State Energy Code, this approach is also being evaluated by ASHRAE Standard 90.l Project Committee and has the potential to provide a comprehensive performance-based approach for HVAC system evaluation and analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A New Gold Mine? Achieving HVAC Energy Efficiency Through a System Metric

Washington State's Commercial Energy Code adopted a new energy metric called HVAC Total System Performance Ratio (TSPR) in 2019, a first in the codes world to regulate HVAC system efficiency. TSPR is a ratio of annual heating and cooling loads to the annual carbon emissions associated with the energy consumed by the HVAC system. TSPR provides a performance-based solution to evaluate and improve the overall HVAC design. The TSPR metric and its companion calculation tool were developed by Pacific Northwest National Laboratory (PNNL) with support from U.S. Department of Energy (DOE), Northwest Energy Efficiency Alliance (NEEA) and the City of Seattle. The new metric represents a significant shift in how HVAC design will meet code requirements. Utility programs can also leverage TSPR as a measure to determine energy savings and incentive amounts for HVAC retrofits. This paper describes the efforts by NEEA and its collaborators to prepare the market for TSPR adoption in code. This paper provides the pilot projects led by University of Washington Integrated Design Lab (IDL) to understand potential issues that could be faced by early adopters. This paper also covers how training and outreach provide engagement opportunities that can streamline code compliance, help address issues faced by early adopters and promote participation in utility programs. As Washington State works on the goals of 70% energy reduction and zero fossil-fuel greenhouse gas emission homes and buildings by the year 2031 , system level performance metrics will likely become increasingly more necessary and prevalent. This paper concludes that the HVAC TSPR requirement helps familiarize the HVAC industry with this approach and helps Washington achieve its long-term goals.

Liu, Bing↗

Technical Support Document for Version 3.9.1 of the COMcheck Software

This technical support document (TSD) is designed to explain the technical basis for the COMcheck software as originally developed based on the ANSI/ASHRAE/IES Standard 90.1-1989 (Standard 90.1-1989). Documentation for other national model codes and standards and specific state energy codes supported in COMcheck has been added to this report as appendices. These appendices are intended to provide technical documentation for features specific to the supported codes and for any changes made for state-specific codes that differ from the standard features that support compliance with the national model codes and standards. Beginning with COMcheck version 3.8.0, support for 90.1-1989, 90.1-1999, and the 1998 IECC and version 3.9.0 support for 2000 and 2001 IECC are no longer included, but those sections remain in this document for reference purposes.

Commercial buildings, HVAC, lighting, building env↗

Orange County Photovoltaic Project & Educational COmponent

The purpose of this report is to discuss the projects implemented, utilizing Department of Energy grant funds, to support the use and understanding of renewable energy in Orange County, Florida and the Greater Orlando Area. Orange County is located in the State of Florida and is most popularly referred to as Orlando. The greater Orlando area’s current population is 1,225,267 and in 2015 was the first destination to surpass 60 million visitors. Orange County utilized grant funds to add to the growing demand for access to charging stations by installing one level 2 dual NovaCharge CT4021 electric vehicle charging station at the Orange County/University of Florida Cooperative Extension Center. The charging station is considered a “smart” charger connected to a central network operated by a third party. Data collected includes the number of charging sessions, session start and end times, the electricity usage, greenhouse gases saved and other pertinent data used for reporting purposes. Orange County continues to support the use of electric vehicles in Metro Orlando and this project continues to bring awareness to our public regarding using alternative vehicles. Additionally, we offer all visitors to the Orange County/University of Florida Cooperative Extension Center free charges for their electric vehicles 24 hours a day. Since the operation of the charging station there have been 52 unique driver users, a total of 532.2258 kg of greenhouse gas savings and 159.03 gallons of gasoline savings. The installation of the additional electric vehicle charging station is part of a county-wide goal of promoting implementation of renewable energy technologies as well as supporting the use of electric vehicles including the Drive Electric Orlando & Florida programs. http://driveelectricorlando.com/ & ; http://www.driveelectricflorida.org/ . Grant funds were also used for Outreach and Educational efforts. Educational efforts about renewable energy were accomplished through the continued support as well as a proposed expansion and potential relocation of the Climate Change Education Center. The growth of the Climate Change Education Center focused on 2 educational subsectors. The first educational sector focused on an apprenticeship with university students. The second sector Orange County partnered with a hospitality college that held seminars to educate students in sustainability best practices that would influence the industry as a whole as students take jobs around the U.S. and other parts of the world. Orange County completed five of the originally proposed six educational seminars. The first seminar focused on community based social marketing techniques for driving sustainable behavior changes. The second seminar held was a green team workshop. The third seminar focused on urban sustainability planning. The fourth and fifth seminars held were Florida Energy Code workshops for building inspectors. A sixth transit oriented development seminar in partnership with Rollins College was explored, but was not conducted because the proposed on campus venue was not accessible for an extended period of time due to renovations. Additionally, an ENERGY STAR training program was conducted with students from the University of Central Florida; three of the five buildings assessed received ENERGY STAR ratings; one student completed the training and received their certification as an ENERGY STAR Specialist. Background: Location: Orange County is located in the central region of the State of Florida and is most popularly known for including the City of Orlando. The greater Orlando area’s current population is 1,225,267 and is home to large corporations such as Walt Disney World, Universal Studios Orlando, Ritz Carlton, Darden Restaurants, and the nation’s second largest convention center. Opportunities Identified: Encouraging Sustainability in Major Sectors: The Central Florida economy is largely dependent on the hospitality industry and in 2015 it was the first destination to surpass 60 million visitors. With over 60 million visitors each year, 120,000 hotel rooms, 4,000 restaurants, and 75 theme parks and attractions, the local hospitality industry provided a wealth of opportunity to reduce greenhouse gas emissions through building energy efficiency and renewable energy. Accordingly, Central Florida is an ideal training ground for teaching best practices for sustainability focused on the hospitality industry. Meeting the Growing Demand for Electric Vehicle Infrastructure: According to the 2014 U.S Clean Tech Leadership Index Report, nationwide electric vehicle ownership in the top 50 largest metro areas increased sharply in 2013; the Orlando Metro Area was ranked #5 in the nation in in terms of electric vehicle charging stations per one million people. Additionally, the Orange County 2014-2015 Annual Sustainable Orange County Report indicated there are 300 electric vehicle charging stations in Central Florida (roughly 300 charging stations within ~70 mile radius available to our residents of Orange County). By increasing and improving access to charging stations, Orange County supports the growing demand for renewable energy technologies. Project Achievements/Accomplishments: Installed an Electric Charging Station: Orange County utilized grant funds to install one level 2 dual NovaCharge CT4021 electric vehicle charging station at the Orange County/University of Florida Cooperative Extension Center. The charging station is considered a “smart” charger connected to a central network operated by a third party that monitors the number of charging sessions, session start and end times, the electricity usage, greenhouse gases saved and other pertinent data. During the six months of operation of the charging station there have been 52 unique driver users of the charging station; a total of 532.2258 kg of greenhouse gas savings and 159.03 gallons of gasoline savings. Operation and Potential Relocation of the Orange County Climate Change Education Center: The Climate Change Education Center, originally located within the Orange County Convention Center, served as a central place to inform and educate commercial and residential sectors of environmental, health, and economic benefits of renewable energy, energy efficiency, and greenhouse gas emission reductions. Grant funds were used to pay for the rent required to maintain a lease at the Convention Center, conduct five educational workshops, and for planned upgrades to the Center displays highlighting a number of energy efficiency and renewable energy projects implemented at the Orange County Convention Center and Downtown Orange County. An initial design concept for an upgraded Climate Change Education Center and educational displays was proposed. However, after the Convention Center determined the space occupied by the Climate Change Education Center; a feasibility study for relocation to the proposed area was conducted in October 2013. In December 2013, it was determined that the desired location of the for the Climate Change Education Center at the Orange County Extension Education Center provided too many construction challenges for relocation with too many building retrofits and access problems, including lack of access for loading and unloading exhibits as well as roof drainage relocations and sewer service connection issues. Another suitable location for relocating the Climate Change Education Center could not be located so the project was terminated. The Climate Change Education Center is no longer in existence in Orange County and has been eliminated. Grant funds were used to pay for marketing services for a state wide marketing program including solar & other renewable energy technologies for rebranding and developing marketing materials including web site design and updating. A website was maintained and updated the www.PowerUpGreenEnergy.com website (no longer in service). Sustainability Training for the Hospitality Industry and Major Sectors: To introduce energy efficiency and renewable energy concepts to the hospitality industry, Orange County partnered with a hospitality college that held seminars to educate students in sustainability best practices that would influence the industry as a whole as students take jobs around the U.S. and other parts of the world. Orange County completed five of the originally proposed six education seminars. Seminar topics included: driving sustainable behavior change through community based social marketing; green team programs; urban sustainability planning; and Florida Energy Code workshops for building inspectors. In partnership with Rollins College, a sixth seminar focused on transit-oriented development was explored, but was not conducted due to extended renovations at the proposed on-campus venue. Green Job Training Development: To promote green industry development and on-the-job training in occupations that encourage energy efficiency and resource reduction, Orange County piloted an ENERGY STAR training and apprenticeship program with students from the University of Central Florida; three students applied for the program; one student completed the training and received their certification as an ENERGY STAR specialist; three of the five buildings assessed received ENERGY STAR Ratings.

14 SOLAR ENERGY↗

ACE Learning Series - Compliance Toolkit

The compliance toolkit describes the steps that should be taken by the build community to make sure that their buildings meet the requirements of the energy codes in effect where the buildings are being built and that the building designs are well-documented so that the enforcement community can quickly and easily determine if the building meets the requirement of the energy code.

IECC, building specifications, code compliance, ne↗

Developing Commercial Code Precalculated Packages

ACEEE Building Summer Study Conference paper to discuss the Developing Commercial Code Precalculated Packages as related to Building Energy codes and standards.

2016 ACEEE Summer Study on Energy Efficiency in Bu↗

Building America Best Practices Series - Volume 11: Builders Challenge Guide to 40% Whole-House Energy Savings in the Marine Climate

This best practices guide is the eleventh in a series of guides for builders produced by the U.S. Department of Energy’s Building America Program. This guide book is a resource to help builders design and construct homes that are among the most energy-efficient available, while addressing issues such as building durability, indoor air quality, and occupant health, safety, and comfort. With the measures described in this guide, builders in the marine climate (portions of Washington, Oregon, and California) can achieve homes that have whole house energy savings of 40% over the Building America benchmark (a home built to mid-1990s building practices roughly equivalent to the 1993 Model Energy Code) with no added overall costs for consumers. These best practices are based on the results of research and demonstration projects conducted by Building America’s research teams. The guide includes information for managers, designers, marketers, site supervisors, and subcontractors, as well as case studies of builders who are successfully building homes that cut energy use by 40% in the marine climate. This document is available on the web at www.buildingamerica.gov. This report was originally cleared 06-29-2010. This version is Rev 1 cleared in Nov 2010.

Builders Challenge↗

Exergy Analysis of Heating Options for Buildings in the Pacific Northwest

A framework for quantifying environmental impact in future energy codes is explored based on exergy analysis. An example exergy analysis is performed that quantifies the environmental impact of electric resistance heating with exergetic efficiency of only 13% compared to 30% and 40% for air source and ground source heat pumps. This provides motivation for removing electric resistance as a space heating option in future energy codes in the Northwest.

Dillon, Heather↗

Energy Reporting: Device Demonstration, Communication Protocols, and Codes and Standards

Energy reporting is the principle that all energy-using devices in buildings should be able to track their own energy use and report this to the local network. Energy reporting can provide building owners with easy access to highly granular energy use data. This report makes the case that energy reporting should become a free basic feature of all devices, and reports on a project intended to move us towards that goal. The project collected a set of demonstration devices with energy reporting features, including products that were modified by the project team or the manufacturer, or are already available for sale. To show these devices operating live at meetings and conferences, the team created a management system that queries the energy reporting devices for their data, stores the data, and displays it in compelling visualizations. The devices covered a wide range, including heating, ventilation, and air conditioning (thermostat and air purifier); lighting (individual bulb, task light, and auto-dimming overhead light); a vehicle charger; a water heater; electronics (notebook personal computer and universal serial bus charger); and three external meters (one integral with a dimming light switch). The demonstration uses a variety of communication protocols. The report reviews existing communication protocols that support energy reporting and describes how to use them with a proposed reference data model for energy reporting. It also assesses ways that energy codes and standards processes can be leveraged to drive energy reporting technology into the market. Energy reporting could ultimately save California on the order of 2.5 terawatt-hours per year and about $0.8 billion per year. Energy reporting is a highly practical technology with minimal (sometimes no) cost to consumers and manufacturers. This report discusses creation of the energy reporting devices themselves, analysis and recommendations for data models and protocols for energy reporting, and energy codes and standards implications of energy reporting technology. While energy reporting does not directly save energy, it provides information for better decision-making to save energy in changing equipment operation, maintenance, and replacement.

devices↗

Air Handling Unit Shutdowns During Scheduled Unoccupied Hours: US Commercial Building Stock Prevalence and Energy Impact

Commercial buildings account for 18% of U.S. energy consumption, with 44% used for heating, ventilation, and air conditioning (HVAC). American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) 90.1 requires HVAC systems to shutdown fans and outdoor air ventilation during unoccupied times, only allowing fans to cycle on, without outdoor air, to maintain thermostat setpoints. However, it is minimally understood how often existing building operations align with energy code requirements and the energy implications of not doing so. This study used building automation system data from 843 buildings containing 5706 air handling units (AHUs) to determine three unoccupied AHU shutdown control schemes ranging in efficiency and then estimated their prevalence in the U.S. commercial building stock, segmented by building type. ComStock was then used to analyze the energy savings potential of implementing the most energy efficient unoccupied shutdown control scheme in non-participating buildings across the U.S commercial building stock. Results show that only 23% of AHUs align completely with the ASHRAE 90.1 requirement. ComStock modeling results show 4% annual stock energy savings by switching all non-participating buildings to the most efficient scheme, with 19% annual energy savings demonstrated for the median building switching from the least efficient scheme to the most efficient. Findings also show 114.5 TBtu electricity and 75.8 TBtu natural gas fuel savings when converting to the most efficient scheme. Furthermore, these findings help stakeholders understand the high prevalence of buildings not aligning with the ASHRAE-90.1 requirements for unoccupied AHU shutdowns and the energy savings potential of utilizing the most efficient unoccupied AHU shutdown scheme.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

State of the States 2010: The Role of Policy in Clean Energy Market Transformation

This report builds on the emerging body of literature seeking to identify quantitative connections between clean energy policy and renewable energy. The methods presented test the relationships between a broad set of policies and clean energy resources (energy efficiency, biomass, geothermal, solar, and wind). Energy efficiency findings are an initial foray into this type of analysis and indicatesignificant connections between reduced energy use and buildings codes, energy efficiency resource standards (in some cases), and electricity price. Renewable energy findings specify that there is most often a relationship between state policies and solar and wind development, indicating that while policies might apply to a wide variety of renewable resources, further tailoring of policyspecifics to resource needs may lead to increased development of a wider variety of renewable energy resources. Further research is needed to refine the connections between clean energy development and policy, especially in the area of the impact of the length of time that a policy has been in place.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

ANSI/ASHRAE/IES Standard 90.1-2013 Preliminary Determination: Qualitative Analysis

Section 304(b) of the Energy Conservation and Production Act (ECPA), as amended, requires the Secretary of Energy to make a determination each time a revised version of ASHRAE Standard 90.1 is published with respect to whether the revised standard would improve energy efficiency in commercial buildings. When the U.S. Department of Energy (DOE) issues an affirmative determination on Standard 90.1, states are statutorily required to certify within two years that they have reviewed and updated the commercial provisions of their building energy code, with respect to energy efficiency, to meet or exceed the revised standard. This report provides a preliminary qualitative analysis of all addenda to ANSI/ASHRAE/IES Standard 90.1-2010 (referred to as Standard 90.1-2010 or 2010 edition) that were included in ANSI/ASHRAE/IES Standard 90.1-2013 (referred to as Standard 90.1-2013 or 2013 edition).

determination↗

State of the States 2010: The Role of Policy in Clean Energy Market Transformation

This report builds on the emerging body of literature seeking to identify quantitative connections between clean energy policy and renewable energy. The methods presented test the relationships between a broad set of policies and clean energy resources (energy efficiency, biomass, geothermal, solar, and wind). Energy efficiency findings are an initial foray into this type of analysis and indicate significant connections between reduced energy use and buildings codes, energy efficiency resource standards (in some cases), and electricity price. Renewable energy findings specify that there is most often a relationship between state policies and solar and wind development, indicating that while policies might apply to a wide variety of renewable resources, further tailoring of policy specifics to resource needs may lead to increased development of a wider variety of renewable energy resources. Further research is needed to refine the connections between clean energy development and policy, especially in the area of the impact of the length of time that a policy has been in place.

09 BIOMASS FUELS↗