Electron gun test report

Shock and vibration tests were performed to determine the electron optical properties of the electron gun. The test procedure included complete mechanical inspection including a dimensional check of all critical parts. Electrical inspection involved tests for dielectric strengths and element to element leakage resistance. All test circuits and equipment for each test are specified in the test plan.

Source record↗

Adding through-bolt holes to pin-fin cold plates

Spot-welding technique is less expensive than secondary-brazing and electron-beam methods. With procedure, standard plates can be modified in quantity for various mounting configurations without need for special tooling.

Ruppe, E. P.↗

Calibration method for an ultrasonic gray-scale recorder

Calibrated method for ultrasonic C-scanning is based on direct correlation of gray-scale response to electronic signal used. In procedure, optical density of reference recording is measured to generate curve of reflective intensity versus transmission.

Moorhead, P. E.↗

GSFC Preferred Parts List PPL-15

A listing is presented of preferred electronic parts, part upgrading procedures, part derating guidelines, and part screening procedures to be used in the selection, procurement, and application of parts for Goddard Space Flight Center space systems and ground support equipment.

Adolphsen, J. W.↗

Sporadic-E layers and unstable wind shears

Electron density profiles of sporadic-E layers have been observed with good height resolution using rocket-borne probes. These generally show a simple shape consistent with the effect of a linear wind shear acting on metallic ions. Occasionally more complex shapes have been recorded, including double peaks and, on one occasion, a nearly rectangular profile. A direct method of obtaining the wind profile from the concentration profile of metallic ions has been developed. The metallic ion concentration profile itself is obtained from the electron density profile. Both procedures derive from the steady-state continuity equation. For linear wind shears it is found that the maximum value of the shear is about 50 m/s/km which corresponds to a Richardson number of 1/4. Layers of complex shape are associated with non-linear wind shears in which the maximum shear considerably exceeds this value. It is concluded that the complex profiles of sporadic-E layers can be interpreted as an effect of unstable wind shears.

Smith, L. G.↗

Theoretical calculation of low-lying states of NaAr and NaXe

Potential curves as well as dipole moments and linking transition moments are calculated for the ground X 2 Sigma + and low lying excited A 2 Pi, B 2 Sigma +, C 2 Sigma +, (4) 2 Sigma +, (2) 2 Pi and (1) 2 Delta states of NaAr and NaXe. Calculations are performed using a self-consistent field plus configuration-interaction procedure with the core electrons replaced by an ab initio effective core potential. The potential curves obtained are found to be considerably less repulsive than the semiempirical curves of Pascale and Vandeplanque (1974) and to agree well with existing experimental data, although the binding energies of those states having potential minima due to van der Waals interactions are underestimated. Emission bands are also calculated for the X 2 Sigma + - C 2 Sigma + excimer transitions of NaAr and NaXe using the calculated transition moments and potential curves, and shown to agree well with experiment on the short-wavelength side of the maximum.

Laskowski, B. C.↗

Electrostatic discharge control for STDN stations

This manual defines the requirements and control methods necessary to control the effect of electrostatic discharges that damage or destroy electronic equipment components. Test procedures for measuring the effectiveness of the control are included.

Mckiernan, J.↗

The Goddard Space Flight Center preferred parts list, revision A

A listing is presented of preferred electronic parts, part upgrading procedures, part derating guidelines, and part screening procedures to be used in the selection, procurement, and application of parts for Goddard Space Flight Center space systems and ground support equipment.

Tyson, N. E.↗

Sodium hydroxide anodization of Ti-Al-4V adherends

The use of sodium hydroxide anodization (SHA) for Ti-6Al-4V adherends is examined. The SHA surface is evaluated using SEM, X-ray photoelectron spectroscopy, and Auger electron spectroscopy. The SHA procedures of Kennedy et al. (1983) were employed in this experiment. The photomicrographs of the SHA (sandblasted) and PSHA (sandblasted and pickled) oxide surface reveal that the two surfaces differ. The PSHA is patchy and similar to a chromic acid anodization surface and the porosity of the PSHA is more uniform than the SHA surface. The compositions of the surfaces are studied. It is noted that SHA is an effective pretreatment for Ti-6Al-4V adherends.

Filbey, Jennifer A.↗

ENVIRONMENTAL SAMPLING AND ANALYSIS - GETTING IT RIGHT

The Department of Energy's Hanford Site in southeastern Washington State was established in the 1940s as part of the Manhattan Project. Hanford's role was to produce weapons-grade nuclear material for defense, and by 1989, when the Site's mission changed from operations to cleanup, Hanford had produced more than 60 percent of the nation's plutonium. The legacy of Hanford's production years is enormous in terms of nuclear and hazardous waste, especially the 270 billion gallons of contaminated groundwater and the 5 million cubic yards of contaminated soil. Managing the contaminated soil and groundwater are particularly important because the Columbia River, the lifeblood of the northwest and the nation's eighth largest river, bounds the Site. Fluor Hanford's Soil & Groundwater Remediation Project (S&GRP) integrates all of the activities that deal with remediating and monitoring the groundwater across the Site. The S&GRP uses a detailed series of steps to record, track, and verify information. The Sample and Data Management (SDM) Process consists of 10 integrated steps that start with the data quality objectives process that establishes the mechanism for collecting the right information with the right people. The process ends with data quality assessment, which is used to ensure that all quantitative data (e.g., field screening, fixed laboratory) are the right type, and of adequate quality to support the decision-making process. Steps 3 through 10 of the process are production steps and are integrated electronically. The detailed plans, procedures, and systems used day-to-day by the SDM process require a high degree of accuracy and reliability. Tools must be incorporated into the processes that minimize errors. This paper discusses all of the elements of the SDM process in detail.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A fully automatic method yielding initial models from high-resolution cryo-electron microscopy maps

Here, we report a fully automated procedure for the optimization and interpretation of reconstructions from cryo-electron microscopy (cryo-EM) data, available in Phenix as phenix.map_to_model. We applied our approach to 476 datasets with resolution of 4.5 Å or better, including reconstructions of 47 ribosomes and 32 other protein–RNA complexes. The median fraction of residues in the deposited structures reproduced automatically was 71% for reconstructions determined at resolutions of 3 Å or better and 47% for those at resolutions worse than 3 Å.

47 OTHER INSTRUMENTATION↗

Recommendations for clinical electron beam dosimetry: Supplement to the recommendations of Task Group 25

The goal of Task Group 25 (TG-25) of the Radiation Therapy Committee of the American Association of Physicists in Medicine (AAPM) was to provide a methodology and set of procedures for a medical physicist performing clinical electron beam dosimetry in the nominal energy range of 5-25 MeV. Specifically, the task group recommended procedures for acquiring basic information required for acceptance testing and treatment planning of new accelerators with therapeutic electron beams. Since the publication of the TG-25 report, significant advances have taken place in the field of electron beam dosimetry, the most significant being that primary standards laboratories around the world have shifted from calibration standards based on exposure or air kerma to standards based on absorbed dose to water. The AAPM has published a new calibration protocol, TG-51, for the calibration of high-energy photon and electron beams. The formalism and dosimetry procedures recommended in this protocol are based on the absorbed dose to water calibration coefficient of an ionization chamber at {sup 60}Co energy, N{sub D,w}{sup 60{sub C}{sub o}}, together with the theoretical beam quality conversion coefficient k{sub Q} for the determination of absorbed dose to water in high-energy photon and electron beams. Task Group 70 was charged to reassess and update the recommendations in TG-25 to bring them into alignment with report TG-51 and to recommend new methodologies and procedures that would allow the practicing medical physicist to initiate and continue a high quality program in clinical electron beam dosimetry. This TG-70 report is a supplement to the TG-25 report and enhances the TG-25 report by including new topics and topics that were not covered in depth in the TG-25 report. These topics include procedures for obtaining data to commission a treatment planning computer, determining dose in irregularly shaped electron fields, and commissioning of sophisticated special procedures using high-energy electron beams. The use of radiochromic film for electrons is addressed, and radiographic film that is no longer available has been replaced by film that is available. Realistic stopping-power data are incorporated when appropriate along with enhanced tables of electron fluence data. A larger list of clinical applications of electron beams is included in the full TG-70 report available at http://www.aapm.org/pubs/reports. Descriptions of the techniques in the clinical sections are not exhaustive but do describe key elements of the procedures and how to initiate these programs in the clinic. There have been no major changes since the TG-25 report relating to flatness and symmetry, surface dose, use of thermoluminescent dosimeters or diodes, virtual source position designation, air gap corrections, oblique incidence, or corrections for inhomogeneities. Thus these topics are not addressed in the TG-70 report.

61 RADIATION PROTECTION AND DOSIMETRY↗

Calculation of secondary electron trajectories in multistage depressed collectors for microwave amplifiers

Computational procedures are reported for treating power losses due to secondary electrons in multistage depressed collectors (MDC) for traveling wave tubes (TWT) and other O-type electron tubes. The MDC is modeled with an advanced, multidimensional computer program. Representative beams of secondary electrons are then injected at the points of impact of the primary beams. Separate programs are used to calculate representative beams of high-energy primary electron beams and of low-energy true secondaries. The recomputation of the MDC model including the true secondary beam allows determination of the secondary emission losses, and, if necessary, redesign of the MDC to improve performance. Recomputation of the MDC model including the primary beams is used to check on possible backstreaming from the MDC to the RF interaction structure of the tube. A comparison with experimentally measured values of TWT and MDC efficiencies is made.

Force, Dale A.↗

Transjugular Renal Biopsy: Our Experience and Technical Considerations

The purpose of this study was to describe the indications for and technique of transjugular renal biopsy (TJRB) and evaluate the efficacy and complications of this method. We performed a retrospective review of 59 patients who underwent TJRB using the Quick-core needle biopsy system (Cook, Letchworth, UK) over a 4-year period. The indications for obtaining renal biopsy included acute renal failure, chronic renal failure, nephrotic syndrome, and proteinuria with or without other associated disease. Indications for the transjugular approach included coagulopathy, biopsy of a solitary kidney or essentially single functioning kidney, simultaneous renal and hepatic biopsy, morbid obesity, and failed percutaneous biopsy. All but four cases were performed via the right internal jugular vein. The right, left, or both renal veins were cannulated in 41, 14, and 4 cases, respectively. Combined liver and renal biopsies were obtained in seven cases. Diagnostic biopsy specimens were obtained in 56 of 59 patients (95%). The number and size of tissue cores ranged from 1 to 9 mm and from 1 to 20 mm, respectively. The mean numbers of glomeruli per procedure on light microscopy and electron microscopy were 10.3 and 2.6, respectively. Specimens for immunohistology were acquired in 49 cases, of which 40 were adequate. Of the 56 successful TJRB procedures, 34 (61%) were associated with isolated capsular perforation (19), contained subcapsular leak (10), isolated collecting system puncture (1), and concurrent collecting system and capsular perforation (4). There was a significant increase in capsular perforation with six or more needle passes, although no significant correlation was seen between number of needle passes and complication. Six patients had minor complications defined as hematuria or loin pain. Seven patients developed major complications, of whom five received blood transfusion alone. Two required intervention: in one an arteriocalyceal fistula was embolized and the patient was temporarily dialyzed; the remaining patient required ureteric stenting. In conclusion, TJRB provides an adequate yield for diagnosis. Complication rates are relatively high, but patients are also at high risk from the conventional percutaneous approach. Patient selection and optimization are critical to avoid major complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electronic Properties of Electrical Vortices in Ferroelectric Nanocomposites from Large-Scale Ab Initio Computations

An original ab initio procedure is developed and applied to a ferroelectric nanocomposite, in order to reveal the effect of electrical vortices on electronic properties. Such procedure involves the combination of two large-scale numerical schemes, namely, the effective Hamiltonian (to incorporate ionic degrees of freedom) and the linear-scaling three-dimensional fragment method (to treat electronic degrees of freedom). The use of such procedure sheds some light into the origin of the recently observed current that is activated at rather low voltages in systems possessing electrical vortices. Finally, it also reveals a novel electronic phenomena that is a systematic control of the type of the band-alignment (i.e., type I versus type II) within the same material via the temperature-driven annihilation/formation of electrical topological defects.

band alignment↗

Looking for footprint of bulk metallic glass in electronic and phonon heat capacities of Cu{sub 55}Hf{sub 45−x}Ti{sub x} alloys

We report on the heat capacity investigation of Cu{sub 55}Hf{sub 45−x}Ti{sub x} metallic glasses. The most appropriate procedure to estimate low temperature electronic and phonon contributions has been determined. Both contributions exhibit monotonous Ti concentration dependence, demonstrating that there is no relation of either the electron density of states at the Fermi level or the Debye temperature to the increased glass forming ability in the Ti concentration range x = 15–30. The thermodynamic parameters (e.g., reduced glass temperature) remain better indicators in assessing the best composition for bulk metallic glass formation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Determination of secondary electron emission characteristics of lunar soil samples

A procedure is described for the determination of the 'apparent crossover voltage', i.e. the value of the primary (bombarding) electron energy at which an insulating sample surface changes the average sign of its charge. This apparent crossover point is characteristic of the secondary emission properties of insulating powders such as the lunar soil samples. Lunar core samples from well-defined, distinct soil layers are found to differ significantly in their secondary emission properties. This observation supports the suggestion that soil layers were deposited by an electrostatic transport process.

Gold, T.↗