Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electron Beam Collimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Guiding and collimation of laser-accelerated proton beams using thin foils followed with a hollow plasma channel

It is proposed that guided and collimated proton acceleration by intense lasers can be achieved using an advanced target—a thin foil followed by a hollow plasma channel. For the advanced target, the laser-accelerated hot electrons can be confined in the hollow channel at the foil rear side, which leads to the formation of transversely localized, Gaussian-distributed sheath electric field and resultantly guiding of proton acceleration. Further, due to the hot electron flow along the channel wall, a strong focusing transverse electric field is induced, taking the place of the original defocusing one driven by hot electron pressure in the case of a purely thin foil target, which results in collimation of proton beams. Two-dimensional particle-in-cell simulations show that collimated proton beams with energy about 20 MeV and nearly half-reduced divergence of 26° are produced at laser intensities 10{sup 20 }W/cm{sup 2} by using the advanced target.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrons in the ionospheric source cone - Evidence for runaway electrons as carriers of downward Birkeland currents

Extremely intense field-aligned fluxes of low energy electrons have been observed with ISIS-2 streaming out of the ionosphere at auroral latitudes. Fluxes in excess of 10 billion per sq cm sec ster at energies below 500 eV with peak fluxes from 10 to 100 eV were detected at 1400 km. The electrons are very strongly field-aligned, having pitch angles confined within 10 deg of the magnetic field. Since they are so intense and so highly collimated they cannot be produced by atmospheric backscattering of a primary auroral beam. These electrons are sometimes associated with ionospheric ions that have been accelerated transverse to the magnetic field. They occur in regions of downward field-aligned current, and may thus be carriers of the current, thus far unidentified. It is suggested that they are runaway electrons from the ionosphere produced by a downward field-aligned component of the electric field.

Klumpar, D. M.↗

The development programme of cathodes and electron guns for the Hollow Electron Lenses of the High Luminosity LHC project1

The High Luminosity LHC project (HL-LHC) foresees the construction and installation of important new equipment to increase the performance of the LHC machine. The Hollow Electron Lens (HEL) is a promising system to control the beam halo. It improves the beam collimation system of the HL-LHC and mitigates possible equipment damage in case of failure scenarios from halo losses. The halo can store up to 30 MJ energy. The specifications for this new device are quite demanding. The source, an electron gun with an annular shaped cathode, has to deliver a current up to 5 A. This is five times higher than the current in the existing electron lenses in Fermi and Brookhaven national laboratories. This note describes the programme carried out to design and test high-perveance guns equipped with two types of high-performance scandate cathodes. The size of the final gun is now considerably smaller than the one of the first prototype, allowing a reduction of diameter and cost of the superconducting magnet system used to steer the electron beam. The tests carried out at FNAL, BVERI and BJUT demonstrated that the developed cathodes fulfil the specifications and can supply a 5 A fully Space Charge Limited (SCL) current.

43 PARTICLE ACCELERATORS↗

Design of high-performance guns for the HL-LHC HEL

The High Luminosity LHC project (HL-LHC) foresees the construction and installation of important new equipment to increase the performance of the LHC machine. The Hollow Electron Lens (HEL) is a promising system to control the beam halo. It improves the beam collimation system of the HL-LHC and mitigates possible equipment damage in case of failure scenarios from halo losses. The halo can store up to 30 MJ energy. The specifications for this new device are quite demanding. The source, an electron gun with an annular shaped cathode, must deliver a current up to 5 A. Additionally, this is five times higher than the current in the existing electron lenses in Fermi and Brookhaven national laboratories. This note describes the programme carried out to design and test high-perveance guns equipped with two types of high-performance scandate cathodes. The size of the final gun for the HL-LHC lenses is now considerably smaller than the one of the first prototype, allowing a reduction of diameter and cost of the superconducting magnet system used to steer the electron beam. The tests carried out at FNAL, BVERI and BJUT demonstrated that the developed cathodes fulfil the specifications and can supply a 5 A fully Space Charge Limited (SCL) current.

43 PARTICLE ACCELERATORS↗

Laser Metrology for an Optical-Path-Length Modulator

Laser gauges have been developed to satisfy requirements specific to monitoring the amplitude of the motion of an optical-path-length modulator that is part of an astronomical interferometer. The modulator includes a corner-cube retroreflector driven by an electromagnetic actuator. During operation of the astronomical interferometer, the electromagnet is excited to produce linear reciprocating motion of the corner-cube retroreflector at an amplitude of 2 to 4 mm at a frequency of 250, 750, or 1,250 Hz. Attached to the corner-cube retroreflector is a small pick-off mirror. To suppress vibrations, a counterweight having a mass equal to that of the corner-cube retroreflector and pick-off mirror is mounted on another electromagnetic actuator that is excited in opposite phase. Each gauge is required to measure the amplitude of the motion of the pick-off mirror, assuming that the motions of the pick-off mirror and the corner-cube retroreflector are identical, so as to measure the amplitude of motion of the corner- cube retroreflector to within an error of the order of picometers at each excitation frequency. Each gauge is a polarization-insensitive heterodyne interferometer that includes matched collimators, beam separators, and photodiodes (see figure). The light needed for operation of the gauge comprises two pairs of laser beams, the beams in each pair being separated by a beat frequency of 80 kHz. The laser beams are generated by an apparatus, denoted the heterodyne plate, that includes stabilized helium-neon lasers, acousto-optical modulators, and associated optical and electronic subsystems. The laser beams are coupled from the heterodyne plate to the collimators via optical fibers.

Gursel, Yekta↗

Absolute elastic differential electron scattering cross sections for He - A proposed calibration standard from 5 to 200 eV

Absolute differential, integral, and momentum-transfer cross sections for electrons elastically scattered from helium are reported for the impact energy range of 5 to 200 eV. Angular distributions for elastically scattered electrons are measured in a crossed-beam geometry using a collimated, differentially pumped atomic-beam source which requires no effective-path-length correction. Below the first inelastic threshold the angular distributions were placed on an absolute scale by use of a phase-shift analysis. Above this threshold, the angular distributions from 10 to 140 deg were fitted using the phase-shift technique, and the resulting integral cross sections were normalized to a semiempirically derived integral elastic cross section. Depending on the impact energy, the data are estimated to be accurate to within 5 to 9%.

Register, D. F.↗

Multibeam tomotherapy: A new treatment unit devised for multileaf collimation, intensity-modulated radiation therapy

A fully integrated system for treatment planning, application, and verification for automated multileaf collimator (MLC) based, intensity-modulated, image-guided, and adaptive radiation therapy (IMRT, IGRT and ART, respectively) is proposed. Patient comfort, which was the major development goal, will be achieved through a new unit design and short treatment times. Our device for photon beam therapy will consist of a new dual energy linac with five fixed treatment heads positioned evenly along one plane but one electron beam generator only. A minimum of moving parts increases technical reliability and reduces motion times to a minimum. Motion is allowed solely for the MLCs, the robotic patient table, and the small angle gantry rotation of {+-}36 deg. . Besides sophisticated electron beam guidance, this compact setup can be built using existing modules. The flattening-filter-free treatment heads are characterized by reduced beam-on time and contain apertures restricted in one dimension to the area of maximum primary fluence output. In the case of longer targets, this leads to a topographic intensity modulation, thanks to the combination of 'step and shoot' MLC delivery and discrete patient couch motion. Owing to the limited number of beam directions, this multislice cone beam serial tomotherapy is referred to as 'multibeam tomotherapy.' Every patient slice is irradiated by one treatment head at any given moment but for one subfield only. The electron beam is then guided to the next head ready for delivery, while the other heads are preparing their leaves for the next segment. The 'Multifocal MLC-positioning' algorithm was programmed to enable treatment planning and optimize treatment time. We developed an overlap strategy for the longitudinally adjacent fields of every beam direction, in doing so minimizing the field match problem and the effects of possible table step errors. Clinical case studies show for the same or better planning target volume coverage, better organ-at-risk sparing, and comparable mean integral dose to the normal tissue a reduction in treatment time by more than 50% to only a few minutes in comparison to high-quality 3-D conformal and IMRT treatments. As a result, it will be possible to incorporate features for better patient positioning and image guidance, while sustaining reasonable overall treatment times at the same time. The virtual multibeam tomotherapy design study TOM'5-CT contains a dedicated electron beam CT (TOM'AGE) and an objective optical topometric patient positioning system (TOPOS registered ). Thanks to the wide gantry bore of 120 cm and slim gantry depths of 70 cm, patients can be treated very comfortably, in all cases tumor-isocentrically, as well as with noncoplanar beam arrangements as in stereotactic radiosurgery with a couch rotation of up to {+-}54 deg. . The TOM'5 treatment unit on which this theoretical concept is based has a stand-alone depth of 40 cm and an outer diameter of 245 cm; the focus-isocenter distance of the heads is 100 cm with a field size of 40 cmx7 cm and 0.5 cm leaves, which operate perpendicular to the axis of table motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

KEKCB electron cyclotron resonance charge breeder at TRIAC

The KEKCB is an electron cyclotron resonance (ECR) ion source for converting singly charged ions to multicharged ones at Tokai Radioactive Ion Accelerator Complex. By using the KEKCB, singly charged gaseous and nongaseous ions were converted to multicharged ones of A/q{approx_equal}7 with efficiencies of 7% and 2%, respectively. The conversion efficiency was found to be independent of the lifetime of the radioactive nuclei having lifetimes of the order of one second. Three collimators located at the entrance and the exit of the KEKCB defined the beam axis and facilitated beam injection. Grinding and washing the surfaces of aluminum electrode and plasma chamber dramatically reduced impurities originating from the ECR plasma of the KEKCB.

43 PARTICLE ACCELERATORS↗

Extinction in the Mu2e Beam Line

The proposed Mu2e experiment at Fermilab has very specific requirements for the proton beam which is used to produce muons. It requires short proton bunches (<100 ns FW), separated by 1-2 musec. It is vital that the beam outside of the bunches be suppressed at a level of at least 10{sup 9} relative to the beam in the bunches. This note briefly presents the motivation for this 'extinction' requirement, and then describes how the experiment hopes to achieve it. Finally, possible techniques for measuring the extinction will be discussed.

43 PARTICLE ACCELERATORS↗

Nonlinear dynamics of proton beams with hollow electron lens in the CERN high-luminosity LHC

The design stored beam energy in the CERN high-luminosity large hadron collider (HL-LHC) upgrade is about 700 MJ, with about 36 MJ in the beam tails, according to estimates based on scaling considerations from measurements at the LHC. Such a large amount of stored energy in the beam tails poses serious challenges on its control and safe disposal. In particular, orbit jitters can cause significant losses on primary collimators, which can lead to accidental beam dumps, magnet quenches, or even permanent damage to collimators and other accelerator elements. Thus, active control of the diffusion speed of halo particles is necessary and the use of hollow electron lenses (HELs) represents the most promising approach to handle overpopulated tails at the HL-LHC. HEL is a very powerful and advanced tool that can be used for controlled depletion of beam tails, thus enhancing the performance of beam halo collimation. For these reasons, HELs have been recently included in the HL-LHC baseline. In this paper, we present detailed beam dynamics calculations performed with the goal of defining HEL specifications and operational scenarios for HL-LHC. The prospects for effective halo control in HL-LHC are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Stable long range proton acceleration driven by intense laser pulse with underdense plasmas

Proton acceleration is investigated by 2.5-dimensional particle-in-cell simulations in an interaction of an ultra intense laser with a near-critical-density plasma. It was found that multi acceleration mechanisms contribute together to a 1.67 GeV collimated proton beam generation. The W-BOA (breakout afterburner based on electrons accelerated by a wakefield) acceleration mechanism plays an important role for the proton energy enhancement in the area far from the target. The stable and continuous acceleration maintains for a long distance and period at least several pico-seconds. Furthermore, the energy scalings are also discussed about the target density and the laser intensity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Apparatus for GHz rate high duty cycle pulsing and manipulation of low and medium energy DC electron beams

An ElectroMagnetic-Mechanical Pulser can generate electron pulses at rates up to 50 GHz, energies up to 1 MeV, duty cycles up to 10%, and pulse widths between 100 fs and 10 ps. A modulating Transverse Deflecting Cavity (“TDC”) imposes a transverse modulation on a continuous electron beam, which is then chopped into pulses by an adjustable Chopping Collimating Aperture. Pulse dispersion due to the modulating TDC is minimized by a suppressing section comprising a plurality of additional TDC's and/or magnetic quadrupoles. In embodiments the suppression section includes a magnetic quadrupole and a TDC followed by four additional magnetic quadrupoles. The TDC's can be single-cell or triple-cell. A fundamental frequency of at least one TDC can be tuned by literally or virtually adjusting its volume. TDC's can be filled with vacuum, air, or a dielectric or ferroelectric material. Embodiments are easily switchable between passive, continuous mode and active pulsed mode.

Baryshev, Sergey V.↗

Quasimonoenergic collimated electrons from the ionization of nitrogen by a chirped intense laser pulse

A scheme is proposed for quasimonoenergic collimated GeV electrons generated during ionization of nitrogen by a chirped intense laser pulse. The electrons accelerated by a laser pulse without a frequency chirp are known for poor-quality beams. If a suitable frequency chirp is introduced, then the energy of the electrons increases significantly. It is shown that quasimonoenergic collimated GeV electrons can be produced using a right choice of laser spot size, frequency chirp, and pulse duration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Delivery validation of an automated modulated electron radiotherapy plan

Purpose: Modulated electron radiation therapy (MERT) represents an active area of interest that offers the potential to improve healthy tissue sparing in treatment of certain cancer cases. Challenges remain however in accurate beamlet dose calculation, plan optimization, collimation method, and delivery accuracy. In this work, the authors investigate the accuracy and efficiency of an end-to-end MERT plan and automated delivery method. Methods: Treatment planning was initiated on a previously treated whole breast irradiation case including an electron boost. All dose calculations were performed using Monte Carlo methods and beam weights were determined using a research-based treatment planning system capable of inverse optimization. The plan was delivered to radiochromic film placed in a water equivalent phantom for verification, using an automated motorized tertiary collimator. Results: The automated delivery, which covered four electron energies, 196 subfields, and 6183 total MU was completed in 25.8 min, including 6.2 min of beam-on time. The remainder of the delivery time was spent on collimator leaf motion and the automated interfacing with the accelerator in service mode. Comparison of the planned and delivered film dose gave 3%/3mm gamma pass rates of 62.1%, 99.8%, 97.8%, 98.3%, and 98.7% for the 9, 12, 16, and 20 MeV, and combined energy deliveries, respectively. Delivery was also performed with a MapCHECK device and resulted in 3%/3 mm gamma pass rates of 88.8%, 86.1%, 89.4%, and 94.8% for the 9, 12, 16, and 20 MeV energies, respectively. Conclusions: Results of the authors’ study showed that an accurate delivery utilizing an add-on tertiary electron collimator is possible using Monte Carlo calculated plans and inverse optimization, which brings MERT closer to becoming a viable option for physicians in treating superficial malignancies.

60 APPLIED LIFE SCIENCES↗

Note: A real-time beam current density meter

We have developed a real-time beam current density meter for charged particle beams. It measures the mean current density by collimating a uniform and large diameter primary beam. The suppression of the secondary electrons and the deflection of the beam were simulated, and it was tested with a 105 keV Ar{sup 7+} ion beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulse Compression of Nd:YAG Laser with Stimulated Brillouin Scattering for Compton Backscattered X-ray Source

Compton backscattered x-ray source is developed in the energy region of a few hundred keV at Kansai Photon Science Institute of Japan Atomic Energy Agency (KPSI-JAEA). A remarkable feature of the Compton backscattered x-ray source is that the generated x-ray beam is a well-collimated and has a definite polarization property. The Compton backscattered x-ray source at KPSI-JAEA consists of the 150-MeV electron beam with the pulse duration of 24 ps accelerated by Microtron accelerator and a Nd:YAG laser with the pulse duration of 23 ns. At the first trial of the X-ray generation, the x-ray flux is not enough for actual use. As an actual x-ray source, it is important to increase the generated x-ray flux as much as possible. Thus, in order to increase the x-ray flux, we develop the pulse compression system for the Nd:YAG laser through the stimulated Brillouin scattering (SBS). The SBS pulse compression is characterized by its high conversion efficiency and by its simplicity of construction. On this article, we describe the present status of the SBS pulse compression for the Compton backscattered x-ray source at KPSI-JAEA.

07 ISOTOPE AND RADIATION SOURCES↗

Resonant excitation of coherent Cerenkov radiation in dielectric lined waveguides

We report the observation of coherent Cerenkov radiation in the terahertz regime emitted by a relativistic electron pulse train passing through a dielectric lined cylindrical waveguide. We describe the beam manipulations and measurements involved in repetitive pulse train creation including comb collimation and nonlinear optics corrections. With this technique, modes beyond the fundamental are selectively excited by use of the appropriate frequency train. The spectral characterization of the structure shows preferential excitation of the fundamental and of a higher longitudinal mode.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Report of AAPM Therapy Physics Committee Task Group 74: In-air output ratio, S{sub c}, for megavoltage photon beams

The concept of in-air output ratio (S{sub c}) was introduced to characterize how the incident photon fluence per monitor unit (or unit time for a Co-60 unit) varies with collimator settings. However, there has been much confusion regarding the measurement technique to be used that has prevented the accurate and consistent determination of S{sub c}. The main thrust of the report is to devise a theoretical and measurement formalism that ensures interinstitutional consistency of S{sub c}. The in-air output ratio, S{sub c}, is defined as the ratio of primary collision water kerma in free-space, K{sub p}, per monitor unit between an arbitrary collimator setting and the reference collimator setting at the same location. Miniphantoms with sufficient lateral and longitudinal thicknesses to eliminate electron contamination and maintain transient electron equilibrium are recommended for the measurement of S{sub c}. The authors present a correction formalism to extrapolate the correct S{sub c} from the measured values using high-Z miniphantom. Miniphantoms made of high-Z material are used to measure S{sub c} for small fields (e.g., IMRT or stereotactic radiosurgery). This report presents a review of the components of S{sub c}, including headscatter, source-obscuring, and monitor-backscattering effects. A review of calculation methods (Monte Carlo and empirical) used to calculate S{sub c} for arbitrary shaped fields is presented. The authors discussed the use of S{sub c} in photon dose calculation algorithms, in particular, monitor unit calculation. Finally, a summary of S{sub c} data (from RPC and other institutions) is included for QA purposes.

61 RADIATION PROTECTION AND DOSIMETRY↗