Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electrical Safety”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Static Electric Fields and Lightning Over Land and Ocean in Florida Thunderstorms

Natural cloud-to-ground (CG) lightning and the charge structure of the associated clouds behave differently over land and ocean. Existing literature has raised questions over the years on the behavior of thunderstorms and lightning over oceans, and there are still open scientific questions. We expand on the observational datasets by obtaining identical electric field observations over coastal land, near-shore, and deep ocean regions during both clear air and thunderstorm periods. Oceanic observations were obtained using two 3-meter NOAA buoys that were instrumented with Campbell Scientific electric field mills to measure the static electric fields. These data were compared to selected electric field records from the existing on-shore electric field mill suite of 31 sensors at Kennedy Space Center (KSC). CG lightning occurrence times, locations and peak current values for both on-shore and ocean were provided by the U.S. National Lightning Detection Network. The buoy instruments were first evaluated on-shore at the Florida coast, to calibrate field enhancements and to confirm proper behavior of the system in elevated-field environments. The buoys were then moored 20NM and 120NM off the coast of KSC in February (20NM) and August (120NM) 2014. Statistically larger CG peak currents were reported over the deep ocean for first strokes and for subsequent strokes with new contacts points. Storm-related static fields were significantly larger at both oceanic sites, likely due to decreased screening by nearby space charge. Time-evolution of the static field during storm development and propagation indicated weak or missing lower positive charge regions in most storms that initiated over the deep ocean, supporting one mechanism for the observed high peak currents in negative first strokes over the deep ocean. This project also demonstrated the practicality of off-shore electric field measurements for safety-related decision making at KSC.

Electric Fields↗

Cable Tester Box

Cables are very important electrical devices that carry power and signals across multiple instruments. Any fault in a cable can easily result in a catastrophic outcome. Therefore, verifying that all cables are built to spec is a very important part of Electrical Integration Procedures. Currently, there are two methods used in lab for verifying cable connectivity. (1) Using a Break-Out Box and an ohmmeter this method is time-consuming but effective for custom cables and (2) Commercial Automated Cable Tester Boxes this method is fast, but to test custom cables often requires pre-programmed configuration files, and cables used on spacecraft are often uniquely designed for specific purposes. The idea is to develop a semi-automatic continuity tester that reduces human effort in cable testing, speeds up the electrical integration process, and ensures system safety. The JPL-Cable Tester Box is developed to check every single possible electrical connection in a cable in parallel. This system indicates connectivity through LED (light emitting diode) circuits. Users can choose to test any pin/shell (test node) with a single push of a button, and any other nodes that are shorted to the test node, even if they are in the same connector, will light up with the test node. The JPL-Cable Tester Boxes offers the following advantages: 1. Easy to use: The architecture is simple enough that it only takes 5 minutes for anyone to learn how operate the Cable Tester Box. No pre-programming and calibration are required, since this box only checks continuity. 2. Fast: The cable tester box checks all the possible electrical connections in parallel at a push of a button. If a cable normally takes half an hour to test, using the Cable Tester Box will improve the speed to as little as 60 seconds to complete. 3. Versatile: Multiple cable tester boxes can be used together. As long as all the boxes share the same electrical potential, any number of connectors can be tested together.

Lee, Jason H.↗

Pilots’ Perspectives on Urban Air Mobility Safety Challenges and Potential Solutions

As electric vertical takeoff and landing air taxis make their way to urban airspace operations within the United States National Airspace System, many research efforts are underway to identify and understand pertinent issues needed to support the influx of new, passenger-carrying, air vehicles over highly dense, urban communities. The primary focus of the Urban Air Mobility (UAM) Pilot/Provider of Services for UAM Information Exchange and Contingency Airspace Management Procedures study was to gather subjective data from subject matter experts concerning current-day airspace operations to identify potential gaps and improvements needed to support and sustain near-term UAM operations. These potential gaps and improvements will form the foundation for the development of initial information exchange requirements between the on-board pilot in command and other key entities. This paper focuses on the in-flight incapacitated pilot scenario from Phase I of the study, which gathered data from helicopter and general aviation fixed-wing pilots.

Urban Air Mobility↗

Pilots’ Perspectives on Urban Air Mobility Safety Challenges and Potential Solutions

As electric vertical takeoff and landing air taxis make their way to urban airspace operations within the United States National Airspace System, many research efforts are underway to identify and understand pertinent issues needed to support the influx of new, passenger-carrying, air vehicles over highly dense, urban communities. The primary focus of the Urban Air Mobility (UAM) Pilot/Provider of Services for UAM Information Exchange and Contingency Airspace Management Procedures study was to gather subjective data from subject matter experts concerning current-day airspace operations to identify potential gaps and improvements needed to support and sustain near-term UAM operations. These potential gaps and improvements will form the foundation for the development of initial information exchange requirements between the on-board pilot in command and other key entities. This paper focuses on the in-flight incapacitated pilot scenario from Phase I of the study, which gathered data from helicopter and general aviation fixed-wing pilots.

Urban Air Mobility↗

Preliminary Measurements of Partial Discharge Inception Voltage Degradation with Constant Temperature Aging of Magnet Wire Twisted Pairs for Electric Aircraft Motors

Electric aircraft require high reliability electric motors to meet the stringent safety standards of the aviation industry. Motor winding insulation lifetime and reliability models for electric aircraft applications are needed to enable design of high reliability and high-performance electric motors for aviation applications. Three primary stresses effect the lifetime of motor winding insulation: thermochemical, mechanical, and electrical. This paper presents preliminary experiments on twisted pairs of magnet wire targeting understanding the thermo-chemical degradation of motor winding insulation through constant temperature thermal aging. Three types of magnet wire twisted pairs where tested: polyimide insulated magnet wire, epoxy coated polyimide insulated magnet wire, and epoxy potted polyimide magnet wire. The degradation of the samples over time at temperature was tracked using partial discharge inception voltage measurements. These initial experiments were used for development of procedures and expertise in partial discharge testing and thermo-chemical aging to inform future testing. The preliminary nature of these experiments should be noted when viewing the results. Lessons learned from the experiments are documented.

Thomas Tallerico↗

Static Electric Fields and Lightning Over Land and Ocean in Florida Thunderstorms

Natural cloud-to-ground (CG) lightning and the charge structure of the associated clouds behave differently over land and ocean. Existing literature has raised questions over the years on the behavior of thunderstorms and lightning over oceans, and there are still open scientific questions. We expand on the observational datasets by obtaining identical electric field observations over coastal land, near-shore, and deep ocean regions during both clear air and thunderstorm periods. Oceanic observations were obtained using two 3-meter NOAA buoys that were instrumented with Campbell Scientific electric field mills to measure the static electric fields. These data were compared to selected electric field records from the existing on-shore electric field mill suite of 31 sensors at Kennedy Space Center (KSC). CG lightning occurrence times, locations and peak current values for both on-shore and ocean were provided by the U.S. National Lightning Detection Network. The buoy instruments were first evaluated on-shore at the Florida coast, to calibrate field enhancements and to confirm proper behavior of the system in elevated-field environments. The buoys were then moored 20NM and 120NM off the coast of KSC in February (20NM) and August (120NM) 2014. Statistically larger CG peak currents were reported over the deep ocean for first strokes and for subsequent strokes with new contacts points. Storm-related static fields were significantly larger at both oceanic sites, likely due to decreased screening by nearby space charge. Time-evolution of the static field during storm development and propagation indicated weak or missing lower positive charge regions in most storms that initiated over the deep ocean, supporting one mechanism for the observed high peak currents in negative first strokes over the deep ocean. This project also demonstrated the practicality of off-shore electric field measurements for safety-related decision making at KSC.

Lightning↗

Electric vehicle post-crash Recovery—Stranded energy issues and mitigation strategy

In post-crash situations, passengers, bystanders, and first responders are exposed to the immediate safety risks of stranded energy in electric vehicle (EV) batteries. Stranded energy is the energy remaining inside any undamaged or damaged battery following an accident. A potentially damaged battery with an unknown state of safety might go into thermal runaway in the absence of proper monitoring, diagnostics, controls, and handling—thereby leading to potential loss of life and property damage. Therefore, it is imperative to develop standard guidelines, diagnostic methods, and tools to handle stranded energy appropriately and minimize safety risks from immediately after an EV accident to final disposal or re-entry to the road. This perspective paper identifies the challenges associated with handling stranded energy and proposes some potential solution pathways. Further, we hope to draw attention of the research and development community, original equipment manufacturers, and policymakers for motivating new insights and research needs in mitigating safety implications associated with stranded energy.

25 ENERGY STORAGE↗

Commercialization of Lithium Battery Technologies for Electric Vehicles

We present that the currently commercialized lithium-ion batteries have allowed for the creation of practical electric vehicles, simultaneously satisfying many stringent milestones in energy density, lifetime, safety, power, and cost requirements of the electric vehicle economy. The next wave of consumer electric vehicles is just around the corner. Although widely adopted in the vehicle market, lithium-ion batteries still require further development to sustain their dominating roles among competitors. In this review, the authors survey the state-of-the-art active electrode materials and cell chemistries for automotive batteries. The performance, production, and cost are included. The advances and challenges in the lithium-ion battery economy from the material design to the cell and the battery packs fitting the rapid developing automotive market are discussed in detail. Additionally, new technologies of promising battery chemistries are comprehensively evaluated for their potential to satisfy the targets of future electric vehicles.

25 ENERGY STORAGE↗

Potential Operating Orbits for Fission Electric Propulsion Systems Driven by the SAFE-400

Safety must be ensured during all phases of space fission system design, development, fabrication, launch, operation, and shutdown. One potential space fission system application is fission electric propulsion (FEP), in which fission energy is converted into electricity and used to power high efficiency (Isp greater than 3000s) electric thrusters. For these types of systems it is important to determine which operational scenarios ensure safety while allowing maximum mission performance and flexibility. Space fission systems are essentially nonradioactive at launch, prior to extended operation at high power. Once high power operation begins, system radiological inventory steadily increases as fission products build up. For a given fission product isotope, the maximum radiological inventory is typically achieved once the system has operated for a length of time equivalent to several half-lives. After that time, the isotope decays at the same rate it is produced, and no further inventory builds in. For an FEP mission beginning in Earth orbit, altitude and orbital lifetime increase as the propulsion system operates. Two simultaneous effects of fission propulsion system operation are thus (1) increasing fission product inventory and (2) increasing orbital lifetime. Phrased differently, as fission products build up, more time is required for the fission products to naturally convert back into non-radioactive isotopes. Simultaneously, as fission products build up, orbital lifetime increases, providing more time for the fission products to naturally convert back into non-radioactive isotopes. Operational constraints required to ensure safety can thus be quantified.

Houts, Mike↗

Solid-State Architecture Batteries for Enhanced Rechargeability and Safety (SABERS) Beyond Li-Ion: Technology to Enable Next-Generation Sustainable Electric

All-electric vertical take-off and landing vehicles (eVTOL) for urban air mobility (UAM) concepts face numerous challenging technical barriers before their introduction into the consumer marketplace. The primary barrier to overcome is developing an energy storage system that meets rigorous aerospace safety and performance criteria. The performance metrics for eVTOL vehicles are at least two times greater than those of electric ground vehicles. Furthermore, inherently non-flammable batteries are essential for the safe operation of commercial electric aero vehicles. The SABERS concept proposes a battery that meets the critical performance criteria by developing a solid-state architecture battery utilizing a high-capacity sulfur-selenium cathode and lithium metal anode. The combination of sulfur and selenium offers a balanced energy-to-power density ratio, which can be tailored to the specific application by altering the stoichiometric ratios of sulfur to selenium. This hybrid cathode will be developed using NASA-patented holey graphene technology as a highly conductive, ultra-lightweight electrode scaffold. A solid-state electrolyte will be used as a safe, non-flammable replacement for the highly flammable liquid organic electrolytes currently in SOA lithium-ion batteries. This solid-state lithium-sulfur/selenium cell will be designed in a serial stacking configuration to enable the dense packaging of the battery cells. The serial stacking configuration is termed a bipolar stack, which has the advantages of reducing overall cell weight, simplifying the interfaced connections for the cell, and minimizing the cooling requirements. Lastly, the optimization of battery components will occur through a robust and rigorous combination of various computational modeling techniques covering multiple length scales. The expected result will be a fully solid-state battery with operational temperatures up to 150°C, providing the required energy density, discharge rates, and inherent safety to meet the strict aerospace mission performance criteria. The SABERS team employed novel materials development, computational modeling, and design-of-experiments (DOE) optimization studies in their research. This presentation will show the results of these studies and demonstrate a feasible path for solid-state cells with a specific energy greater than 400 Wh/kg to enable electric aircraft.

Computational Modeling↗

Potential applications of industrial wireless technologies in the future HTR - 18505

High Temperature Reactor (HTR) is a kind of promising nuclear reactor for supplying electricity and heat with inherent safety. The High Temperature Reactor-Pebble bed Modular reactor (HTR-PM) in China is equipped with the Distributed Control System (DCS) where wired network is applied mainly based on fiber. Considering the difficulty and cost of implementation, the flexibility of network configuration and maintenance, the industrial wireless network might be potential for some cases in the network of the next generation of HTR. Nowadays, there are several technologies available for choice, such as wireless HART, WIA-PA and ZigBee. Characteristics of these technologies are introduced. The most important factors for choice of the technology of network are the required reliability and latency tolerance of communication. Analysis and classification of the communications needed in the network of the HTR are carried out, and a comparison of popular industrial wireless technologies, including the reliability, the latency, the communication distance, and the difficulty and cost of implementation is made. Generally speaking, considering the low latency, high reliability and the compatibility with HART devices, wireless HART is promising. WIA-PA could be applied if redundant gateway is required. ZigBee might show its advantages in power consumption and cost. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dataset for: Electric Vulnerability Index: Targeted Energy Storage Implementation Metric

Uninterrupted access to electricity is critical to the safety and security of American households. More frequent and extreme emergency events increase outages across the country, disproportionately impacting vulnerable communities that experience the most frequent and longest outages, are most sensitive to the loss of electric power, and have the least capacity to adapt to these conditions. This study devises a metric, the Electric Vulnerability Index (EVI), and validates this metric against the 2021 Winter Storm Uri in Texas. Though not ubiquitous, similar trends were observed between adjacent areas with higher EVI and those with higher outage rates from this storm. EVI is offered as a viable approach to quantify a population’s vulnerability to electric outages and maps that index across the continental United States to aid policymakers, advocates, and energy system stakeholders in the targeted deployment of resilience solutions, such as energy storage, to communities most in need. This dataset includes the geopackage file containing all relevant attributes used to generate the maps used in the accompanying paper.

Kerby, Jessica [Pacific Northwest National Laborat↗

Say What? Effective communication is safe business

Ineffective safety communication can result in injury and even cost lives. With hazards surrounding workers, such as chemicals, electrical equipment and construction machinery, adequate safety messages and training are imperative for good business. Safety communication in the workplace is so important, it’s required in Washington State. WAC 296-800-130 requires employers to have a method of communicating and evaluating safety and health issues brought up by employers or employees in the workplace. Fortunately, there are lots of resources to help employers communicate with staff.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

High safety and cycling stability of ultrahigh energy lithium ion batteries

High-nickel layered oxide Li-ion batteries (LIBs) dominate the electric vehicle market, but their potentially poor safety and thermal stability remain a public concern. Here, we show that an ultrahigh-energy LIB (292 Wh kg –1 ) becomes intrinsically safer when a small amount of triallyl phosphate (TAP) is added to standard electrolytes. TAP passivates the electrode-electrolyte interfaces and limits the maximum cell temperature during nail penetration to 55°C versus complete cell destruction (>950°C) without TAP. The downside of this reliable safety solution is higher interfacial impedance and hence lower battery power; however, thermal modulation for battery operation around 60°C can restore power completely. When cycled at 60°C, the cell stabilized with TAP achieved 2,413 cycles at 76% capacity retention. Such an unconventional combination of interface-passivating electrolyte additive with cell thermal modulation renders the most energy-dense LIBs even safer than LiFePO 4 chemistry, while enjoying high power and cycling stability concurrently.

25 ENERGY STORAGE↗

Quantitative Risk Assessment for Fuel Cell Electric Bus Hydrogen Storage and Refueling Facility

It is necessary to understand the safety implications and risk mitigation options for fuel cell electric bus fleet deployment, especially for related facilities responsible for operations such as production, storage, compression, and dispensing of hydrogen for use by the buses. In this report, we present a quantitative risk assessment for a potential fuel cell electric bus fleet that was motivated by efforts to improve resilience at the Portland International Airport but can be applicable to a range of hydrogen case studies and use cases. We estimated risk for a facility that produces, stores, compresses, and dispenses hydrogen for the fleet of buses, with a focus on individual risk to people in terms of annual frequency of fatality. We considered the frequency of hydrogen leaks that could result in harmful physical outcomes like jet fires or explosions, and the consequences of those outcomes for people. We created customized fault trees to calculate the frequencies of different sizes of leaks and event sequence diagrams to calculate ignition probabilities for the various leak sizes. We also leveraged the HyRAM+ toolkit to use these inputs to calculate overall risk for the facility, which we separated into one section responsible for producing, storing, and compressing hydrogen, and one section responsible for dispensing the hydrogen to the buses. We found that the dispensing area seemed to have a higher risk than the production/storage/compression area of the facility, largely because of the inclusion of a component with a high leak frequency (the heat exchanger used to cool the hydrogen before entering the vehicle, to prevent overheating and expansion of hydrogen in the onboard tank). For the example production and refueling facility we evaluated and the data we used for the analysis, the leak frequency had a larger impact on the risk differences between the two sections on the facility, compared to the physical outcome consequence, which was slightly different due to the varying fuel conditions, but not substantially different. Actions can be taken to prevent these hazards (e.g., lowering leak frequencies in system components) or to mitigate the consequences if they do occur (e.g., installing barriers to protect people if ignition events occur). The choice of which actions to take depends not only on safety considerations but also on space, time, staffing, feasibility, and financial constraints. Therefore, the quantitative risk assessment approach can help understand relative risk contributions from different components, leak sizes, consequences, and human actions, to prioritize risk reduction strategies and balance these parameters. The outcomes of this report may be useful for a variety of stakeholders working in the hydrogen, transportation, vehicle, and aviation sector, including those responsible for aspects like facility design, operations, and regulations. There is not a single value of risk that determines whether a hypothetical system is “safe” or not. The insights about risk mitigations may be leveraged, and the quantitative risk assessment approach can be applied to other case studies to understand risk priorities and contributions specific to different FCEB and hydrogen facility uses.

08 HYDROGEN↗

Passive safety device and internal short tested method for energy storage cells and systems

A passive safety device for an energy storage cell for positioning between two electrically conductive layers of the energy storage cell. The safety device also comprising a separator and a non-conductive layer. A first electrically conductive material is provided on the non-conductive layer. A first opening is formed through the separator between the first electrically conductive material and one of the electrically conductive layers of the energy storage device. A second electrically conductive material is provided adjacent the first electrically conductive material on the non-conductive layer, wherein a space is formed on the non-conductive layer between the first and second electrically conductive materials. A second opening is formed through the non-conductive layer between the second electrically conductive material and another of the electrically conductive layers of the energy storage device. The first and second electrically conductive materials combine and exit at least partially through the first and second openings to connect the two electrically conductive layers of the energy storage device at a predetermined temperature.

25 ENERGY STORAGE↗

Progress in the development of the neutron flux monitoring system of the French GEN-IV SFR: simulations and experimental validations [ANIMMA--2015-IO-392]

France has a long experience of about 50 years in designing, building and operating sodium-cooled fast reactors (SFR) such as RAPSODIE, PHENIX and SUPER PHENIX. Fast reactors feature the double capability of reducing nuclear waste and saving nuclear energy resources by burning actinides. Since this reactor type is one of those selected by the Generation IV International Forum, the French government asked, in the year 2006, CEA, namely the French Alternative Energies and Atomic Energy Commission, to lead the development of an innovative GEN-IV nuclear- fission power demonstrator. The major objective is to improve the safety and availability of an SFR. The neutron flux monitoring (NFM) system of any reactor must, in any situation, permit both reactivity control and power level monitoring from startup to full power. It also has to monitor possible changes in neutron flux distribution within the core region in order to prevent any local melting accident. The neutron detectors will have to be installed inside the reactor vessel because locations outside the vessel will suffer from severe disadvantages; radially the neutron shield that is also contained in the reactor vessel will cause unacceptable losses in neutron flux; below the core the presence of a core-catcher prevents from inserting neutron guides; and above the core the distance is too large to obtain decent neutron signals outside the vessel. Another important point is to limit the number of detectors placed in the vessel in order to alleviate their installation into the vessel. In this paper, we show that the architecture of the NFM system will rely on high-temperature fission chambers (HTFC) featuring wide-range flux monitoring capability. The definition of such a system is presented and the justifications of technological options are brought with the use of simulation and experimental results. Firstly, neutron-transport calculations allow us to propose two in-vessel regions, namely the above-core and under-core structures. We verify that they comply with the main objective, that is the neutron power and flux distribution monitoring. HTFC placed in these two regions can detect an inadvertent control rod withdrawal that is a postulated initiating event for safety demonstration. Secondly, we show that the HTFC reliability is enhanced thanks to a more robust physical design and the fact that it has been justified that the mineral insulation is insensitive to any increase in temperature. Indeed, the HTFC insulation is subject to partial discharges at high temperature when the electric field between their electrodes is greater than about 200 V/mm or so. These discharges give rise to signals similar to the neutron pulses generated by a fission chamber itself, which may bias the HTFC count rate at start-up only. However, as displayed in Figure 1, we have experimentally verified that one can discriminate neutron pulses from partial discharges using online estimation of pulse width. Thirdly, we propose to estimate the count rate of a HTFC using the third order cumulant of its signal that is described by a filtered Poisson process. For such a statistic process, it is known that any cumulant, also called cumulative moment, is proportional to the process intensity that is here the count rate of a fission chamber. One recalls that the so-called Campbelling mode of such a detector is actually based on the signal variance, which is the second-order cumulant as well. The use of this extended Campbelling mode based on the third-order cumulant will permit to ensure the HTFC response linearity over the entire neutron flux range using a signal processing technique that is simple enough to satisfy design constraints on electric devices important for nuclear safety. We also show that this technique, named high order Campbelling method (HOC), is significantly more robust than another technique based on the change in the HTFC filling gas, which consists in adding a few percent of nitrogen. Finally, we also present an experimental campaign devoted to the required calibration process of the so-called HOC method. The Campbelling results show a good agreement with the simple pulse counting estimation at low count rates. It is also shown that the HOC technique provides a linear estimation of the count rates at higher power levels as well.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Consumer Guide to Electric Vehicles

Learn what an electric vehicle (EV) could mean for you, including fuel economy, emission reductions, cost savings, and fueling flexibility. This fact sheet from Energy Saver includes information on types of electric vehicles, how an EV could save you on fuel and money, how to charge an EV, and EV safety standards.

electric vehicles, EVs, BEVs, PHEVs, Energy Saver↗