Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EYES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Standard-Fractionated Radiotherapy for Optic Nerve Sheath Meningioma: Visual Outcome Is Predicted by Mean Eye Dose

Purpose: Radiotherapy has shown its efficacy in controlling optic nerve sheath meningiomas (ONSM) tumor growth while allowing visual acuity to improve or stabilize. However, radiation-induced toxicity may ultimately jeopardize the functional benefit. The purpose of this study was to identify predictive factors of poor visual outcome in patients receiving radiotherapy for ONSM. Methods and Materials: We conducted an extensive analysis of 10 patients with ONSM with regard to clinical, radiologic, and dosimetric aspects. All patients were treated with conformal radiotherapy and subsequently underwent biannual neuroophthalmologic and imaging assessments. Pretreatment and posttreatment values of visual acuity and visual field were compared with Wilcoxon's signed rank test. Results: Visual acuity values significantly improved after radiotherapy. After a median follow-up time of 51 months, 6 patients had improved visual acuity, 4 patients had improved visual field, 1 patient was in stable condition, and 1 patient had deteriorated visual acuity and visual field. Tumor control rate was 100% at magnetic resonance imaging assessment. Visual acuity deterioration after radiotherapy was related to radiation-induced retinopathy in 2 patients and radiation-induced mature cataract in 1 patient. Study of radiotherapy parameters showed that the mean eye dose was significantly higher in those 3 patients who had deteriorated vision. Conclusions: Our study confirms that radiotherapy is efficient in treating ONSM. Long-term visual outcome may be compromised by radiation-induced side effects. Mean eye dose has to be considered as a limiting constraint in treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ion therapy for uveal melanoma in new human eye phantom based on GEANT4 toolkit

Radiotherapy with ion beams like proton and carbon has been used for treatment of eye uveal melanoma for many years. In this research, we have developed a new phantom of human eye for Monte Carlo simulation of tumors treatment to use in GEANT4 toolkit. Total depth−dose profiles for the proton, alpha, and carbon incident beams with the same ranges have been calculated in the phantom. Moreover, the deposited energy of the secondary particles for each of the primary beams is calculated. The dose curves are compared for 47.8 MeV proton, 190.1 MeV alpha, and 1060 MeV carbon ions that have the same range in the target region reaching to the center of tumor. The passively scattered spread-out Bragg peak (SOBP) for each incident beam as well as the flux curves of the secondary particles including neutron, gamma, and positron has been calculated and compared for the primary beams. The high sharpness of carbon beam's Bragg peak with low lateral broadening is the benefit of this beam in hadrontherapy but it has disadvantages of dose leakage in the tail after its Bragg peak and high intensity of neutron production. However, proton beam, which has a good conformation with tumor shape owing to the beam broadening caused by scattering, can be a good choice for the large-size tumors.

61 RADIATION PROTECTION AND DOSIMETRY↗

Out of the Corner of My Eye: Foveal Semantic Load Modulates Parafoveal Processing in Reading.

In two experiments, we examined the impact of foveal semantic expectancy and congruity on parafoveal word processing during reading. Experiment 1 utilized an eye-tracking gaze contingent display change paradigm, and Experiment 2 measured event-related brain potentials (ERP) in a modified RSVP paradigm to track the time-course of foveal semantic influences on convert attentional allocation to parafoveal word processing. Furthermore, eye-tracking and ERP data converged to reveal graded effects of semantic foveal load on parafoveal processing.

97 MATHEMATICS AND COMPUTING↗

Origami silicon optoelectronics for hemispherical electronic eye systems

Digital image sensors in hemispherical geometries offer unique imaging advantages over their planar counterparts, such as wide field of view and low aberrations. Deforming miniature semiconductor-based sensors with high-spatial resolution into such format is challenging. Here we introduce a simple origami approach for fabricating single-crystalline silicon-based focal plane arrays and artificial compound eyes that have hemisphere-like structures. Convex isogonal polyhedral concepts allow certain combinations of polygons to fold into spherical formats. Using each polygon block as a sensor pixel, the silicon-based devices are shaped into maps of truncated icosahedron and fabricated on flexible sheets and further folded either into a concave or convex hemisphere. These two electronic eye prototypes represent simple and low-cost methods as well as flexible optimization parameters in terms of pixel density and design. Results demonstrated in this work combined with miniature size and simplicity of the design establish practical technology for integration with conventional electronic devices.

42 ENGINEERING↗

Spectral optimization simulation of white light based on the photopic eye-sensitivity curve

Spectral optimization simulation of white light is studied to boost maximum attainable luminous efficacy of radiation at high color-rendering index (CRI) and various color temperatures. The photopic eye-sensitivity curve V(λ) is utilized as the dominant portion of white light spectra. Emission spectra of a blue InGaN light-emitting diode (LED) and a red AlInGaP LED are added to the spectrum of V(λ) to match white color coordinates. It is demonstrated that at the condition of color temperature from 2500 K to 6500 K and CRI above 90, such white sources can achieve spectral efficacy of 330–390 lm/W, which is higher than the previously reported theoretical maximum values. We show that this eye-sensitivity-based approach also has advantages on component energy conversion efficiency compared with previously reported optimization solutions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

THE ALLEN TELESCOPE ARRAY FLY'S EYE SURVEY FOR FAST RADIO TRANSIENTS

The relatively unexplored fast radio transient parameter space is known to be home to a variety of interesting sources, including pulsars, pulsar giant pulses, and non-thermal emission from planetary magnetospheres. In addition, a variety of hypothesized but as-yet-unobserved phenomena such as primordial black hole evaporation and prompt emission associated with coalescing massive objects have been suggested. The 2007 announcement by Lorimer et al. of the detection of a bright (30 Jy) radio pulse that was inferred to be of extragalactic origin and the subsequent consternation have demonstrated both the need for wide-field surveys characterizing the fast-transient parameter space and the potential utility of bright radio pulses as probes of the interstellar medium and intergalactic medium. Here we present results from the 450 hr, 150 deg{sup 2} Fly's Eye survey for bright dispersed radio pulses at the Allen Telescope Array (ATA). The Fly's Eye Spectrometer produces 128 channel power spectra over a 209 MHz bandwidth, centered at 1430 MHz, on 44 independent signal paths originating with 30 independent ATA antennae. Data were dedispersed between 0 and 2000 pc cm{sup -3} and searched for pulses with dispersion measures greater than 50 pc cm{sup -3} between 625 {mu}s and 5 s in duration. No pulses were detected in the survey, implying a limiting rate of less than 2 sky{sup -1} hr{sup -1} for 10 ms duration pulses having apparent energy densities greater than 440 kJy {mu}s, or mean flux densities greater than 44 Jy. Here we present details of the instrument, experiment, and observations, including a discussion of our results in light of other single pulse searches.

79 ASTRONOMY AND ASTROPHYSICS↗

A Unified Protocol for CRISPR/Cas9-Mediated Gene Knockout in Tephritid Fruit Flies Led to the Recreation of White Eye and White Puparium Phenotypes in the Melon Fly

Abstract Tephritid fruit flies are among the most invasive and destructive agricultural pests worldwide. Over recent years, many studies have implemented the CRISPR/Cas9 genome-editing technology to dissect gene functions in tephritids and create new strains to facilitate their genetics, management, and control. This growing literature allows us to compare diverse strategies for delivering CRISPR/Cas9 components into tephritid embryos, optimize procedures, and advance the technology to systems outside the most thoroughly studied species within the family. Here, we revisit five years of CRISPR research in Tephritidae and propose a unified protocol for candidate gene knockout in fruit flies using CRISPR/Cas9. We demonstrated the efficiency of our protocol by disrupting the eye pigmentation gene white eye (we) in the melon fly, Zeugodacus cucurbitae (Coquillett) (Diptera: Tephritidae). High rates of somatic and germline mutagenesis were induced by microinjecting pre-assembled Cas9-sgRNA complexes through the chorion of embryos at early embryogenesis, leading to the rapid development of new mutant lines. We achieved comparable results when targeting the we orthologue in the oriental fruit fly, Bactrocera dorsalis (Hendel) (Diptera: Tephritidae), illustrating the reliability of our methods when transferred to other related species. Finally, we functionally validated the recently discovered white pupae (wp) loci in the melon fly, successfully recreating the white puparium phenotype used in suppression programs of this and other major economically important tephritids. This is the first demonstration of CRISPR-based genome-editing in the genus Zeugodacus, and we anticipate that the procedures described here will contribute to advancing genome-editing in other non-model tephritid fruit flies.

Entomology↗

Radiobiology for eye plaque brachytherapy and evaluation of implant duration and radionuclide choice using an objective function

Purpose: Clinical optimization of Collaborative Ocular Melanoma Study (COMS) eye plaque brachytherapy is currently limited to tumor coverage, consensus prescription dosage, and dose calculations to ocular structures. The biologically effective dose (BED) of temporary brachytherapy treatments is a function of both chosen radionuclide R and implant duration T. This study endeavored to evaluate BED delivered to the tumor volume and surrounding ocular structures as a function of plaque position P, prescription dose, R, and T. Methods: Plaque-heterogeneity-corrected dose distributions were generated with MCNP5 for the range of currently available COMS plaques loaded with sources using three available low-energy radionuclides. These physical dose distributions were imported into the PINNACLE{sup 3} treatment planning system using the TG-43 hybrid technique and used to generate dose volume histograms for a T = 7 day implant within a reference eye geometry including the ciliary body, cornea, eyelid, foveola, lacrimal gland, lens, optic disc, optic nerve, retina, and tumor at eight standard treatment positions. The equation of Dale and Jones was employed to create biologically effective dose volume histograms (BEDVHs), allowing for BED volumetric analysis of all ROIs. Isobiologically effective prescription doses were calculated for T = 5 days down to 0.01 days, with BEDVHs subsequently generated for all ROIs using correspondingly reduced prescription doses. Objective functions were created to evaluate the BEDVHs as a function of R and T. These objective functions are mathematically accessible and sufficiently general to be applied to temporary or permanent brachytherapy implants for a variety of disease sites. Results: Reducing T from 7 to 0.01 days for a 10 mm plaque produced an average BED benefit of 26%, 20%, and 17% for {sup 103}Pd, {sup 125}I, and {sup 131}Cs, respectively, for all P; 16 and 22 mm plaque results were more position-dependent. {sup 103}Pd produced a 16%-35% BED benefit over {sup 125}I, whereas {sup 131}Cs produced a 3%-7% BED detriment, independent of P, T, and plaque size. Additionally, corresponding organ at risk physical doses were lowest using {sup 103}Pd in all circumstances. Conclusions: The results suggest that shorter implant durations may correlate with more favorable outcomes compared to 7 day implants when treating small or medium intraocular lesions. The data also indicate that implant duration may be safely reduced if the prescription physical dose is likewise diminished and that {sup 103}Pd offers a substantial radiobiological benefit over {sup 125}I and {sup 131}Cs irrespective of plaque position, implant duration, and tumor size.

61 RADIATION PROTECTION AND DOSIMETRY↗

TH-E-17A-10: Markerless Lung Tumor Tracking Based On Beams Eye View EPID Images

Purpose: Dynamic tumor tracking or motion compensation techniques have proposed to modify beam delivery following lung tumor motion on the flight. Conventional treatment plan QA could be performed in advance since every delivery may be different. Markerless lung tumor tracking using beams eye view EPID images provides a best treatment evaluation mechanism. The purpose of this study is to improve the accuracy of the online markerless lung tumor motion tracking method. Methods: The lung tumor could be located on every frame of MV images during radiation therapy treatment by comparing with corresponding digitally reconstructed radiograph (DRR). A kV-MV CT corresponding curve is applied on planning kV CT to generate MV CT images for patients in order to enhance the similarity between DRRs and MV treatment images. This kV-MV CT corresponding curve was obtained by scanning a same CT electron density phantom by a kV CT scanner and MV scanner (Tomotherapy) or MV CBCT. Two sets of MV DRRs were then generated for tumor and anatomy without tumor as the references to tracking the tumor on beams eye view EPID images. Results: Phantom studies were performed on a Varian TrueBeam linac. MV treatment images were acquired continuously during each treatment beam delivery at 12 gantry angles by iTools. Markerless tumor tracking was applied with DRRs generated from simulated MVCT. Tumors were tracked on every frame of images and compared with expected positions based on programed phantom motion. It was found that the average tracking error were 2.3 mm. Conclusion: This algorithm is capable of detecting lung tumors at complicated environment without implanting markers. It should be noted that the CT data has a slice thickness of 3 mm. This shows the statistical accuracy is better than the spatial accuracy. This project has been supported by a Varian Research Grant.

60 APPLIED LIFE SCIENCES↗

SU-E-J-56: Static Gantry Digital Tomosynthesis From the Beam’s-Eye-View

Purpose We have designed a novel TumoTrak™ x-ray system that delivers 19 distinct kV views with the linac gantry stationary. It images MV treatment beam above and below the patient with a kV tomosysthesis slice image from the therapy beam’s-eye-view. Results will be high quality images without MLC shadowing for notable improvements relative to conventional fluoroscopic MV imaging and fluoroscopic kV imaging. Methods A complete design has a kV electron beam multisource X-ray tube that fits around the MV treatment beam path, with little interference with normal radiotherapy and unblocked by the multi-leaf-collimator. To simulate digital tomosynthesis, we used cone-beam CT projection data from a lung SBRT patient. These data were acquired at 125 kVp and 11 fps (0.4 mAs per projection). We chose 19 projections evenly spaced over 27° around one of the treatment angles (240°). Digital tomosynthesis reconstruction of a slice through the tumor was performed using iterative reconstruction. The visibility of the lesion was assessed for the reconstructed digital tomosynthesis (DTS), using fluoroscopy MV images acquired during radiation therapy, and a kV single projection image acquired at the same angle as the treatment field (240°). Results The fluoroscopic DTS images provide the best tumor contrast, surpassing the conventional radiographic and the in-treatment MV portal images. The electron beam multisource X-ray tube design has been completed and the tube is being fabricated. The estimated time to cycle through all 19 projections is 700 ms, enabling high frame-rate imaging. While the initial proposed use case is for image guided and gated treatment delivery, the enhanced imaging will also deliver superior radiographic images for patient setup. Conclusion The proposed device will deliver high quality planar images from the beam’s-eye-view without MLC obstruction. The prototype has been designed and is being assembled with first imaging scheduled for May 2015. L. Partain, J. Kwon, D. Boyd: NIH/SBIR R43CA192489-01. J. Rottmann, G. Zentai, R. Berbeco: NIH/NCI 1R01CA188446-01. R. Berbeco: E. Research Grant, Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Performance of "Moth Eye" Anti-Reflective Coatings for Solar Cell Applications

An inexpensive, effective anti-reflective coating (ARC) has been developed at the University of Florida to significantly enhance the absorption of light by silicon in solar cells. This coating has nano-scale features, and its microstructure mimics that of various night active insects (e.g. a moth's eye). It is a square array of pillars, each about 700 nm high and having a diameter of about 300 nm. Samples of silicon having this coating were exposed either to various combinations of either elevated temperature and humidity or to gamma irradiation ({sup 60}Co) at the Savannah River National Laboratory, or to a broad spectrum ultraviolet light and to a 532 nm laser light at the University of Florida. The anti-reflective properties of the coatings were unaffected by any of these environmental stresses, and the microstructure of the coating was also unaffected. In fact, the reflectivity of the gamma irradiated ARC became lower (advantageous for solar cell applications) at wavelengths between 400 and 1000 nm. These results show that this coating is robust and should be tested in actual systems exposed to either weather or a space environment. Structural details of the ARCs were studied to optimize their performance. Square arrays performed better than hexagonal arrays - the natural moth-eye coating is indeed a square array. The optimal depth of the templated nanopillars in the ARC was investigated. A wet etching technology for ARC formation was developed that would be less expensive and much faster than dry etching. Theoretical modeling revealed that dimple arrays should perform better than nipple arrays. A method of fabricating both dimple and nipple arrays having the same length was developed, and the dimple arrays performed better than the nipple arrays, in agreement with the modeling. The commercial viability of the technology is quite feasible, since the technology is scalable and inexpensive. This technology is also compatible with current industrial fabrication of solar cells.

14 SOLAR ENERGY↗

Using Eye-Tracking to Quantify Reverse Engineering Expertise

Software reverse engineering (RE) requires analysts to closely read and make decisions about code. Little is known about what makes an analyst successful, making it difficult to train new analysts or design tools to augment existing ones. The goal of this project was to quantify the eye movement behaviors supporting RE and code comprehension more generally. We applied eye-tracking methods from the language comprehension literature to understand where analysts direct their attention over time when completing tasks (e.g., function identification, bug detection). Across three studies, we manipulated aspects of code hypothesized to impact comprehension (e.g., variable name meaningfulness, code complexity) and presentation methods (e.g., line-by-line, free viewing, gaze-contingent moving window) to understand effects on accuracy and gaze patterns. Results showed clear benefits of meaningful variable names, and effects of expertise on global and line-specific viewing patterns. Findings could inspire empirically-supported tool or analytic adaptations that help to reduce analyst workload.

97 MATHEMATICS AND COMPUTING↗

Oculometer for remote tracking of eye movement

Prototype oculometer which tracks lateral eye position and measures the direction of the eyes optical axis, pupil size, and blink occurrence performs measurements on the subject on a real-time basis from a remote location.

Mason, K. A.↗

Eye point-of-regard system

System measures intersection of line of sight and eye point of regard /EPR/ for a human operator in visual scanning system. Device measures two head to reference angles with EPR system and adds them with eye to head angles, yielding a dc signal proportional to picture plane coordinates.

Jex, H. R.↗