FEMAXI-V benchmarking study on peak temperature and fission gas release prediction of PWR rod fuel
The present paper reports a study of FEMAXI-V code and related report on code benchmarking. Capabilities of the FEMAXI-V code to predict the thermal and fission gas release have been tested on MOX fuels in LWRs which has been done in SCK{center_dot}CEN and Belgonucleaire by using PRIMO MOX rod BD8 irradiation experiment after V Sobolev as reported O. J. Ott. Base irradiation in the BR3 reactor, the BD8 rod was transported to CEA-Saclay for irradiation in the OSIRIS reactor (ramp power excursion). The irradiation device used for the PRIMO ramps was the ISABELLE 1 loop, installed on a movable structure of the core periphery. The power variations were obtained by inwards/backwards movements of the loop in the core water. The preconditioning phase for rod BD8 occurred at a peak power level of 189 W/cm with a hold time of 27 hours. The subsequent power excursion rate amounted to 77 W/ (cm.min), reaching a terminal peak power level of 395 W/cm that lasted for 20 hours.