Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EPRI”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Extending Component Lifetime And Improving Inverter Reliability (ECLAIIR)

Inverter reliability remains one of the most persistent challenges limiting the performance, availability, and economic viability of utility‑scale photovoltaic (PV) plants. Industry data consistently show that inverters account for the highest share of corrective maintenance events and unplanned outages across PV fleets. These failures result in energy losses, increased O&M costs, and reduced confidence in long‑term solar asset performance. Motivated by these challenges, this project—Extending Component Lifetime and Improving Inverter Reliability (ECLAIIR)—was undertaken to systematically investigate inverter degradation and failure mechanisms, develop predictive maintenance capabilities, and establish data‑driven pathways to improve service life and reduce the Levelized Cost of Energy (LCOE) for large‑scale PV systems. The primary goal of the project was to identify pre‑failure signatures in string inverters using both lab‑based accelerated lifetime testing and field‑based data and to develop predictive maintenance algorithms that can anticipate inverter faults before they occur. Through collaboration with inverter testing laboratory, solar PV plant owner, and failure‑analysis experts, the project advanced the technical understanding of inverter reliability. By instrumenting inverters with thermistors, humidity sensors, power‑quality meters, and acoustic sensors, the research established how multiple sensing modalities can reliably detect deviations from normal behavior hours to days before failure. These findings substantially enhance scientific understanding of inverter failure kinetics and provide the PV industry with the most comprehensive cross‑OEM characterization of early‑stage failure indicators reported to date. Technically, the project demonstrated the effectiveness of predictive maintenance by developing and validating the PreDICT (Predictive Diagnostics of PV Inverters Using Condition Monitoring and Trend Analysis) framework—a multi‑layer diagnostic architecture combining peer‑to‑peer analytics, historical trend modeling, and advanced machine‑learning techniques such as the Sequential Conditional Variational Autoencoder (SCVAE). This predictive model achieved more than 90% accuracy in detecting pre‑failure conditions and provided up to four days of lead time before inverter failure in field scenarios. Economically, the project’s LCOE analysis showed that predictive maintenance can reduce lifetime energy losses and minimize corrective maintenance interventions. Modeling indicated that, depending on inverter failure rates and replacement timelines, predictive maintenance can significantly reduce LCOE impacts associated with inverter downtime: from as high as 19.4% under conventional maintenance strategies to 0.1%–10.17% when predictive analytics are adopted. These results confirm that predictive maintenance is both technically feasible and economically advantageous for utilities and plant operators. The project’s findings also have broad public benefit. By improving inverter reliability and reducing downtime, predictive maintenance directly increases electricity generation from existing PV assets. Enhanced reliability lowers operational costs for utilities, which can translate over time into lower energy costs for consumers. Furthermore, the project’s technical publications, conference presentations, and industry workshops ensure that knowledge gained is shared broadly across the solar industry, supporting workforce development and enabling utilities of all sizes to adopt modern asset‑health monitoring practices. The retrofitting case study and service‑life prediction framework further support informed decision‑making for aging PV fleets, helping operators extend system life and reduce electronic waste. In summary, the ECLAIIR project significantly advanced the state of knowledge on inverter degradation, demonstrated the technical and economic value of predictive maintenance, and delivered actionable tools and insights that support more reliable, cost‑effective, and sustainable PV plant operation. The outcomes of this project will continue to inform utility practices, guide inverter design improvements, and strengthen the long‑term performance of solar assets nationwide.

14 SOLAR ENERGY↗

Laboratory Evaluation of Commercial Utility Microgrid Controller Test Results

The functional requirements of many microgrid controllers (MGCs) are expanding and evolving to meet growing utility and community needs. At a high level, the utility microgrid controller serves resilience and reliability use cases by coordinating transitions between grid-connected and islanded states and by managing the system during island operations. This includes control scenarios that require the microgrid controller to use flexible microgrid boundaries, maintain energy balance, coordinate with peer systems, and manage grid-forming (GFM) and grid-following (GFL) distributed energy resources (DER). In order to evaluate these functional enhancements, microgrid controller test plans must also be developed to ensure that the implemented controllers provide adequate performance. This report provides MGC test plans for both island operation and transition functions. The functions covered in this report include feeder level energy management, island constraint management, secondary voltage and frequency control, black start, and synchronized reconnection. This second edition update also includes results from applying the tests to a commercial utility microgrid controller. These results evaluate the performance and reliability of the controller under various operational scenarios. It identifies specific areas where the controller excels and highlights gaps that need to be addressed for future enhancements. The application of these test plans on real-world system behavior provides insights on commercial equipment readiness for field deployment. These test cases can be applied to utility-managed microgrid controllers that exclusively manage utility-owned equipment; the tests also apply to third-party managed microgrid controllers that coordinate with utility- and customer-owned equipment. The report can also be used by technology developers and project developers in industry to evaluate control strategies and performance characteristics for community microgrid controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Field Demonstration and Adoption Impacts of an Affordable Thermoelectric Heat Pump

This study presents the design, field validation, and utility impacts of an air source heat pump that uses thermoelectric (TE) technology to provide supplemental heating at outside air temperatures below 17°F. Conventional heat pumps experience reduced heating capacity and COP at low outdoor temperatures due to the temperature difference between the source and demand sides of the vapor compression cycle. Consequently, during colder months, supplemental heating such as electric resistance or natural gas furnace is often needed to provide additional warmth, which increases the overall equipment and energy costs. To address this challenge, a TE subcooler (an array of solid-state, thermoelectric modules that provides heat pumping using non-vapor compression technique) is fabricated and integrated with the vapor compression cycle of a conventional air-source heat pump. In colder ambient conditions, TE subcooler exchanges heat with the refrigerant to provide additional subcooling, thereby enhancing the capacity of the heat pump. The operation of thermoelectric-integrated heat pump was demonstrated in an occupied single-family home in Nashville, TN. The TE subcooler increased the system’s heating capacity at 15°F outdoor temperature by 25–30% and reduced electricity demand by 10%. It also met the heating load in the house without supplemental electric resistance down to 5°F outdoors, delivering the additional heat at nearly 80% greater efficiency compared to electric resistance heating. With a modest first cost increment of 10–15% over conventional single-speed heat pumps, this approach offers a promising, energy-efficient solution to accelerate residential heat pump adoption in the U.S.

KRISHNAMOORTHY, Sreenidhi [Electric Power Research↗

Integration of a thermoelectric subcooler with an air‑source heat pump to enhance heating capacity and dehumidification

This study presents an innovative configuration of a thermoelectric subcooler (TES) integrated with an air-source heat pump (ASHP). The TES is installed in the liquid line, where it absorbs heat from the refrigerant. On its hot side, it discharges heat to the return air in heating mode or to the supply air in cooling mode, enabling year-round operation. The ASHP–TES system was evaluated under various conditions to reduce supplemental heating needs and improve dehumidification. Experimental heating tests revealed that activating the TES increased the heating capacity by 12%–20%. However, this occurred with a 7.6%–10% reduction in heating coefficient of performance (COP). In cooling mode, TES operation significantly improved moisture removal. The TES reduced the sensible heat ratio (SHR) and enhanced dehumidification, removing 20%–50% more moisture than a conventional system when meeting the same sensible load. The TES can be turned off to use the refrigerant subcooler for reheat supply air or turned on to substantially boost dehumidification. When meeting the same latent load, the ASHP–TES system achieved up to 33% energy savings compared with a conventional ASHP using resistance heating. Relative to a conventional ASHP paired with a whole-house dehumidifier, the ASHP–TES system provided up to 20% energy savings. These findings underscore the potential of TES integration to improve latent load control and enhance overall energy efficiency in hybrid ASHP systems, especially in cold and humid climates.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

IASCC of 304 SS in BWR environments: Effects of post-irradiation annealing and surface condition

To investigate the impact of low-temperature post-irradiation annealing (PIA) on the stress corrosion cracking of neutron-irradiated 304 stainless steel, constant extension rate tests were conducted in simulated boiling water reactor normal water chemistry (BWR-NWC) and hydrogenated water chemistry (HWC) environments. Ten tensile samples, comprising five as-irradiated and five PIA specimens, were prepared by electropolishing the gauge section of electric discharge machined (EDM) samples. Here, the annealing treatment reduced the yield strength from approximately 550 MPa to around 425 MPa and significantly restored the ductility and the strain hardening capability of the alloy. Consequently, the susceptibility of this material to irradiation-assisted stress corrosion cracking (IASCC) was effectively mitigated, which is more prominent in HWC, as evident from fractography, which indicated a decreased propensity for intergranular (IG) fracture. Furthermore, it was observed that the polished surface facilitated crack initiation more readily than the EDM surface, suggesting that the EDM process suppressed crack initiation to some extent.

Crack initiation↗

Heating performance of an air source heat pump with a portable thermoelectric subcooler

This study investigates the heating performance of an integrated air-source heat pump (ASHP) with a thermoelectric subcooler (TES) module, revealing significant performance enhancements, particularly in colder temperatures. Results show that adding the portable TES boosts the ASHP's heating capacity, making it feasible for residential applications. The coefficient of performance (COP) for the TE system, which is influenced by condensing temperatures and ambient conditions, ranges from 1.51 to 2.07. If condensing temperatures are consistently maintained above 35 °C, a TE COP of approximately 2.07 is achievable, supporting system downsizing and reducing supplemental heating. When coupled with an oversized indoor coil, the TES-ASHP system delivers comparable heating to a baseline unit while achieving a 10 % higher COP. Capacity increases by 8.7 %–24 % with TES in colder conditions, though COP declines by 9 %–18 %, diminishing as temperatures drop. Compared to systems with supplemental heating, this setup achieves a COP 10 %–17 % higher. Future work will involve extended field testing in various climates, exploration of advanced materials for thermal efficiency, and assessment of alternative refrigerants to improve performance and sustainability. This integrated ASHP-TES system holds promise for increased efficiency and reduced environmental impact in cold climates.

Air source heat pump↗

Policy implications of net-zero emissions: A multi-model analysis of United States emissions and energy system impacts

Many countries, subnational jurisdictions, and companies are setting net-zero emissions goals; however, questions remain about strategies to reach these targets, policy measures, technology gaps, and economic impacts. Here, we investigate the potential policy implications of reaching economy-wide net-zero CO 2 emissions across the United States by 2050 using results from a multi-model comparison with 14 energy-economic models. Model results suggest that achieving net-zero CO 2 targets depends on policies that accelerate deployment of zero- and low-emitting technologies that have seen rapid cost reductions in recent years (including wind, solar, battery storage, and electric vehicles) as well as relatively nascent options (including carbon capture and storage, advanced biofuels, low-carbon hydrogen, advanced nuclear, and long-duration energy storage). While net-zero policies are likely to lower fossil fuel consumption, including considerable coal and petroleum reductions, achieving net-zero emissions does not necessarily mean phasing out all fossil fuels. Model results indicate that the Inflation Reduction Act’s energy and climate provisions amplify near-term decarbonization but that net-zero policies have larger impacts on long-run outcomes. Stringent climate policy can have large fiscal impacts on tax revenue and government spending—revenues from carbon pricing and subsidies for carbon removal range from 0.1 % to 3.7 % of GDP in 2050 across models. Each dollar per metric ton carbon price leads to a 0.06 % to 0.31 % reduction in economy-wide CO 2 emissions relative to a reference scenario with current policies. Spending on energy across the economy decreases relative to today for many models under reference and net-zero policies, especially as a share of GDP, due primarily to end-use electrification and energy efficiency.

54 ENVIRONMENTAL SCIENCES↗

Evolving Electricity Supply and Demand to Achieve Net-Zero Emissions: Insights from the EMF-37 Study

This paper explores the role of electricity in achieving economy-wide net-zero CO2 emissions by 2050 in the United States based on results from 17 models as part of the 37th Stanford Energy Modeling Forum (EMF-37). In the study's Net-Zero scenario, the models use diverse pathways to achieve net-zero emissions by 2050, with gross energy-related residual emissions ranging from 17.2 to 66.6 % of 2020 levels. Electricity consistently emerges as central to achieving net-zero, with models projecting rapid electrification of end-uses and rapidly declining CO2 intensity of electricity. However, the extent of electrification and the technology mix to decarbonize the power sector vary considerably across models. In the Net-Zero scenario, electricity is projected to evolve from ~20 % of final energy in 2020 to 17-63 % in 2050 across the models driven by electrification in all sectors-buildings, industry, and transportation-and, to a lesser extent by direct air capture. By 2050, total electricity consumption increases by 24-176 % (relative to 2020), accompanied by significant expansion in renewable electricity production. Together, solar and wind generation grows by 175-834 %, supplying 45-90 % of total electricity in 2050, with wind achieving slightly higher shares than solar. Electricity storage technologies are deployed at scale to support wind and solar generation. The electricity generation mix varies across models: some project almost complete reliance on renewables, while others see a substantial role for natural gas, often with carbon capture and storage. This paper synthesizes the rich diversity of modeling approaches and results, highlighting differing views on how key drivers of electricity demand and supply might evolve.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Transportation in net-zero emissions futures: Insights from the EMF-37 model intercomparison study

Transportation is currently the largest source of U.S. anthropogenic CO 2 emissions, at about a third of the total. Achieving net-zero emissions by mid-century will require substantial reductions in transportation emissions across passenger and freight travel. Here we leverage a model intercomparison study to explore the role of transportation in scenarios achieving net-zero economy-wide CO 2 emissions by 2050. We find the transport sector is poised to play the most significant role in reducing demand-side emissions, mostly driven by technology substitution, as modeling results suggest a limited role for mode shifting and for reduced use of personal car travel in the U.S. Among various technology solutions, models show agreement that passenger on-road vehicles will largely transition to electric vehicles (EVs), while solutions to decarbonize heavier travel modes are more diverse and include greater use of liquid biofuels and hydrogen. Research should continue to investigate the evolution of on-road electrification, the role of biofuels and hydrogen across heavier travel modes, and the role of mode shifting and travel behavior change to support personal transportation decarbonization at national and regional scales to temper the rapid growth in clean fuel and electricity demand.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Laser repair welding of irradiated alloy 182

Welding repair of irradiated nickel-based alloys, such as Alloy 182, poses a significant challenge due to helium-induced cracking (HeIC) and grain boundary degradation (GBD) in the heat affected zone, driven by helium accumulation at grain boundaries and welding-induced tensile stresses. This study investigates the weldability of irradiated Alloy 182 up to 15 wppm doped boron using both conventional laser welding and the Auxiliary Beam Stress Improved (ABSI) laser welding technique. While HeIC was observed at the weld toe of the entry pass in both methods due to the higher effective heat input associated with the initial pass directly on the base metal, no additional cracking occurred elsewhere, even at elevated helium concentrations. Optical and scanning electron microscopy analysis revealed that the ABSI technique, which introduces additional compressive stresses to counteract solidification-induced tensile stresses, significantly reduced GBD formation, lowering its total count from 1,230 to 339 and decreasing both average and maximum GBD lengths. In conclusion, these results demonstrate that the ABSI technique is a promising approach to mitigate helium-induced damage and improve the weldability of irradiated Alloy 182, offering a viable solution for structural repairs for long-term operation of existing nuclear reactors.

grain boundary degradation↗

A model to assess Zircaloy’s mechanical property changes following a transient beyond critical heat flux

Maintaining the integrity of nuclear fuel rods is essential for ensuring public health and safety in nuclear power generation. During reactor operation, this integrity is confirmed by demonstrating compliance with established regulatory acceptance criteria. For moderate-frequency events, such as limiting transients and anticipated operational occurrences (AOOs), the current fuel integrity criterion is based on preventing boiling transition. This criterion assumes that prevention of boiling transition will prevent excessive cladding heating and, thus, fuel failure during normal operations. While conservative, this approach places significant constraints on core design, fuel cycle economics, and a plant’s ability to perform major power uprates, leading to suboptimal fuel utilization and inefficient carbon-free energy production. A more efficient approach could be achieved by revising the failure criterion to a material-specific limit rather than strictly preventing the boiling transition, since boiling transition per se is not a cause of fuel cladding failure. Here, as a result, a new licensing framework based on material properties, termed time-at-temperature (t@T), is needed. This approach would allow for brief periods of post–critical heat flux operation during an AOO without compromising safety. Implementing the t@T licensing strategy requires a robust technical foundation in material properties, which must be established through comprehensive data collection on both unirradiated and irradiated fuel and cladding materials. This foundation would enable the development of a safety basis that ensures safe operation while providing greater flexibility and efficiency for reactor operation. This paper documents a thorough review of the available data to establish a baseline knowledge that can inform the development of cladding mechanical models, as well as identify experimental data gaps that need to be addressed in future research. Machine learning and data informatics were utilized to extract the importance of parameters on the t@T parameter. Industry tools were used to perform baseline analyses to define the relevant transient conditions for data analysis. The subsequent review successfully identified applicable experimental data, as well as sufficient data to evaluate changes in cladding mechanical properties following an AOO transient. Rather than developing new models, this work coupled existing irradiation annealing and recrystallization models to calculate changes in hardness, yield stress, and ultimate tensile stress following an AOO event. The findings from this review were summarized to highlight the experimental data needs required to fill remaining gaps and support the development of future t@T licensing methodologies.

Cladding performance↗

Heat Loss Effects on Emissions in an NH 3 RRQL Combustor

Ammonia (NH 3 ) is a carbon-free energy carrier with an infrastructure for production, storage, and distribution. There is interest in direct NH 3 combustion, but managing pollutant emissions is a key challenge, particularly nitric oxides (NO x ) due to the fuel-bound nitrogen atom, nitrous oxide (N 2 O), which is a potent greenhouse gas, and unburned NH 3 , which is harmful to humans and the environment. Rich staged combustor concepts with extended primary residence times (τ res,primary ), like Rich-Relax- Quick-mix-Lean (RRQL), offer a viable pathway for direct NH 3 combustion with low levels of NO x formation. However, minimizing secondary emissions such as N 2 O and unburned NH 3 and hydrogen (H 2 ) remains a critical challenge. Prior atmospheric-pressure studies have demonstrated that RRQL operation with sufficiently long τ res,primary enables substantial NO x relaxation and promotes NH 3 cracking to H 2 , if heat losses from the relaxation stage are limited. However, the combined influence of elevated pressure and long residence time on RRQL performance has not been explored. The present work examines RRQL operation at pressures up to 5 bar and elevated τ res,primary . Exhaust measurements of NO x , NH 3 , and N 2 O are used to quantify the extent of NO x relaxation and NH 3 cracking under nonadiabatic conditions. To contextualize and quantify the effects of heat losses in the experimental data, chemical reactor networks (CRNs) incorporating prescribed heat loss rates are employed to assess the sensitivity of emissions to thermal losses in the relaxation stage. Collectively, the results demonstrate that management and quantification of heat losses are essential to preserve NO x relaxation and limit NH 3 and N 2 O emissions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measuring Climate and Water Risk across the Bulk Power System

As climate impacts increase and power systems transition to renewables, planners and operators need insights into climate risks to power generation and infrastructure to ensure reliable decision-making in the short and long-term. We present a standardized, consistent mechanism for utilities and system operators to evaluate the climate- and water-related risks of their current and future grid assets. Using a risk-based approach on the combined outcomes of high-fidelity climate drivers together with water and power system models, we examine the temperature and water availability impacts within the contiguous United States to power system assets at the water basin level in three different time periods and report resulting outcomes on lost capacity across different expansion scenarios and climate models. The results indicate that air temperature has the highest effect on derating. Changes in streamflow do not have a large impact on generation capacity at the national level. Electric sector buildout scenarios each have a unique regional risk profile, depending on the technology mix and total capacity, although risks from high temperatures are significant for both traditional and renewable energy generation. Stakeholders can use this approach to monitor effects of generation capacity losses and potential impacts as climate, generation mix, and infrastructure change.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Net Present Value Optimization of a Natural Gas Combined Cycle Plant with CO 2 Capture using a Water-Lean Solvent Considering Transient Electricity Price for Multiple Regions

Global CO 2 emissions are increasing at about a 1.5% rate per year. Fossil fuel-based plants are one of the main contributors to this rise. In the power generation industry, fossil fuel plants are dominant, and many plants are under development. In this study, a natural gas combined cycle (NGCC) power plant with postcombustion capture using a leading water-lean solvent is considered. For optimal design and operating schedule, large-scale dynamic optimization is undertaken for net present value (NPV) optimization. The first principle dynamic model of NGCC is developed, including a model of the highly efficient H-class gas turbines. For computational tractability of the dynamic optimization problem, a reduced-order model is developed by using the Hankel singular value decomposition. A waterlean solvent, N-(2-ethoxyethyl)-3-morpholinopropan-1-amine, is used for carbon capture. A model of the capture system is developed in Aspen Plus, which is used to develop a reduced-order model by using ALAMO, a machine learning software. In addition, a reduced model of the CO 2 compression system with a dehydration unit is also considered. The integrated system is used for NPV optimization by using the Python-based PYOMO platform. The PCC process is analyzed for three configurations-conventional packed bed, rotating packed bed (RPB), and a combination of RPB and direct contact cooler. The NPV optimization is performed for 14 regional markets by considering year-long clustered and continuous locational marginal price data with a 1 h interval. Optimization results show that the PCC can achieve 90% CO 2 capture with a positive NPV for six regions. Sensitivity studies conducted by using the PCC configurations indicate that the process is economically feasible for 9 regions out of 14 regional electricity markets with NPV values in the range of 33−540 $MM.

cabon capture↗

Boiler Health Monitoring Using a Hybrid First Principles-Artificial Intelligence Model

Due to increased penetration of the intermittent renewables to the grid, pulverized coal (PC) plants are being forced to cycle their load frequently and rapidly, operate at low load condition for sustained period, and start up and shut down several hundred times in a year in the worst case. These severe operations are causing substantial damage to the boiler components compromising the reliability of PC plants. An online health monitoring tool can be instrumental in understanding the impacts of load-following and can eventually help PC plants to develop advanced process control strategies for improved flexibility without compromising safety nor reliability.

20 FOSSIL-FUELED POWER PLANTS↗

Intelligently Partitioned Phasor-EMT Hybrid Simulations of Large-Scale, High-IBR Power Systems

As the penetration level of power electronics-interfaced renewables such as photovoltaics (PV) and wind has surged in modern electric grids, new operational risks caused by the dynamics of those inverter-based resources (IBRs) are emerging in parallel. Lessons learned from various grid events include that the impact of IBRs on system-level grid stability will become prominent along with the increase of renewables and that the short-timescale dynamic impacts of IBRs on grid stability are not fully captured by current commercial dynamic simulation tools [1] [2]. For example, IBRs can be controlled to mitigate those destabilizing interactions, but conventional phasor-domain tools (e.g. PSS/E, PSLF) often cannot capture that; likewise, the existing electromagnetic transient (EMT) simulation tools (e.g. PSCAD, EMTP) can simulate detailed IBR controls, but for large power systems with many IBRs, slow simulation speeds severely impede the ability to study dynamic events [3] [4]. Massively paralleling simulations using high-performance computing (HPC) can help address this, especially now that cloud-based HPC capability is widely available, but today s EMT tools are not HPC-compatible, and parallelization of dynamic simulation solvers is not trivial because each region can dynamically affect the others. Thus, dynamic simulation of grids with very large numbers of IBRs potentially poses a barrier to the ongoing energy transition.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Industrial Electrification Technologies Booklet

Electrification refers to transitioning from fuel-powered systems to electrically-powered alternatives. In an industrial context, this primarily refers to the electrification of process heat, but there are also widespread opportunities to electrify space heating and cooling as well as onsite transportation (e.g., forklifts). Electrification does not refer to one particular technology, but a wide range of technologies that use different methods to transfer electrical energy into a usable form – usually heat.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Deployment of Digital Twins and Advanced Instrumentation to Identify Looseness Between Rotor Spider Arms and Rim Attachment in Hydro Turbines

The project aimed to develop a Virtual Sensor Digital Twin (VS-DT) to monitor rotor rim float displacement (RRFD) in legacy hydropower turbines. RRFD, if undetected, can cause rotor and stator damage, leading to costly repairs and safety concerns. The purpose of the VS-DT was to predict RRFD signals using existing conventional sensors instead of installing dedicated, costly physical sensors, thereby reducing operational costs and enhancing safety.

13 HYDRO ENERGY↗