Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Compilation and analysis of charge asymmetry measurements from electron and positron scattering on nucleon and nuclei

World data on the lepton-charge asymmetry in the elastic and inelastic lepton scattering off the proton and nuclei are compiled and discussed. After reviewing the published results, we compare the elastic data to a model calculation of the two-photon-exchange mechanism. We show that the existing data do not provide any evidence for enhancement of the two-photon contribution. At confidence level 95% the data allow to exclude the two-photon exchange as an explanation for the difference between Rosenbluth and polarization transfer measurements of proton electromagnetic form factors.

74 ATOMIC AND MOLECULAR PHYSICS↗

Investigation of novel decay B _____ ____(2S)____K at BaBar

We investigate the undocumented B meson decay, B{sup +} {yields} {Psi}(2S){omega}K{sup +}. The data were collected with the BaBar detector at the SLAC PEP-II asymmetric-energy e{sup +}e{sup -} collier operating at the {gamma}(4S) resonance, a center-of-mass energy of 10.58 GeV/c{sup 2}. The {gamma}(4S) resonance primarily decays to pairs of B-mesons. The BaBar collaboration at the PEP-II ring was located at the SLAC National Accelerator Laboratory and was designed to study the collisions of positrons and electrons. The e{sup -}e{sup +} pairs collide at asymmetric energies, resulting in a center of mass which is traveling at relativistic speeds. The resulting time dilation allows the decaying particles to travel large distances through the detector before undergoing their rapid decays, a process that occurs in the in the center of mass frame over extremely small distances. As they travel through silicon vertex trackers, a drift chamber, a Cerenkov radiation detector and finally an electromagnetic calorimeter, we measure the charge, energy, momentum, and particle identification in order to reconstruct the decays that have occurred. While all well understood mesons currently fall into the qq model, the quark model has no a priori exclusion of higher configuration states such as qqqq which has led experimentalists and theorists alike to seek evidence supporting the existence of such states. Currently, there are hundreds of known decay modes of the B mesons cataloged by the Particle Data Group, but collectively they only account for approximately 60% of the B branching fraction and it is possible that many more exist.

36 MATERIALS SCIENCE↗

Peak radiated power measurement of the DOE Mark II container tag with integrated ST-676 sensor radio frequency identification device.

The total peak radiated power of the Department of Energy Mark II container tag was measured in the electromagnetic reverberation chamber facility at Sandia National Laboratories. The tag's radio frequency content was also evaluated for possible emissions outside the intentional transmit frequency band. No spurious emissions of any significance were found, and the radiated power conformed to the manufacturer's specifications.

99 GENERAL AND MISCELLANEOUS↗

XUV frequency-comb metrology on the ground state of helium

The operation of a frequency comb at extreme ultraviolet (xuv) wavelengths based on pairwise amplification and nonlinear upconversion to the 15th harmonic of pulses from a frequency-comb laser in the near-infrared range is reported. It is experimentally demonstrated that the resulting spectrum at 51 nm is fully phase coherent and can be applied to precision metrology. The pulses are used in a scheme of direct-frequency-comb excitation of helium atoms from the ground state to the 1s4p and 1s5p {sup 1} P{sub 1} states. Laser ionization by auxiliary 1064 nm pulses is used to detect the excited-state population, resulting in a cosine-like signal as a function of the repetition rate of the frequency comb with a modulation contrast of up to 55%. Analysis of the visibility of this comb structure, thereby using the helium atom as a precision phase ruler, yields an estimated timing jitter between the two upconverted-comb laser pulses of 50 attoseconds, which is equivalent to a phase jitter of 0.38 (6) cycles in the xuv at 51 nm. This sets a quantitative figure of merit for the operation of the xuv comb and indicates that extension to even shorter wavelengths should be feasible. The helium metrology investigation results in transition frequencies of 5 740 806 993 (10) and 5 814 248 672 (6) MHz for excitation of the 1s4p and 1s5p {sup 1} P{sub 1} states, respectively. This constitutes an important frequency measurement in the xuv, attaining high accuracy in this windowless part of the electromagnetic spectrum. From the measured transition frequencies an eight-fold-improved {sup 4}He ionization energy of 5 945 204 212 (6) MHz is derived. Also, a new value for the {sup 4}He ground-state Lamb shift is found of 41 247 (6) MHz. This experimental value is in agreement with recent theoretical calculations up to order m{alpha}{sup 6} and m{sup 2}/M{alpha}{sup 5}, but with a six-times-higher precision, therewith providing a stringent test of quantum electrodynamics in bound two-electron systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

A Novel Technique Applying Spectral Estimation to Johnson Noise Thermometry

Johnson noise thermometry is one of many important measurement techniques used to monitor the safety levels and stability in a nuclear reactor. However, this measurement is very dependent on the minimal electromagnetic environment. Properly removing unwanted electromagnetic interference (EMI) is critical for accurate drift-free temperature measurements. The two techniques developed by Oak Ridge National Laboratory (ORNL) to remove transient and periodic EMI are briefly discussed here. Spectral estimation is a key component in the signal processing algorithm used for EMI removal and temperature calculation. The cross-power spectral density is a key component in the Johnson noise temperature computation. Applying either technique requires the simple addition of electronics and signal processing to existing resistive thermometers. With minimal installation changes, the system discussed here can be installed on existing nuclear power plants. The Johnson noise system developed is tested at three locations: ORNL, Sandia National Laboratory, and the Tennessee Valley Authority’s Kingston Fossil Plant. Each of these locations enabled improvement on the EMI removal algorithm. Finally, the conclusions made from the results at each of these locations is discussed, as well as possible future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Quantifying and relating land-surface and subsurface variability in permafrost environments using lidar and surface geophsical datasets

The complexity of permafrost dynamics and its critical impact on climate feedbacks warrant continued development of advanced high-latitude terrestrial ecosystem characterization and monitoring approaches. In this study, we explore the value of remote sensing and surface geophysical data for characterizing land surface and subsurface properties and their linkages in an Alaskan Coastal Plain ecosystem. We base our study on data collected at the end of the 2011 growing season in the Barrow Environmental Observatory, where a nested suite of measurements were collected within a polygon-dominated region including: surface ground penetrating radar, electromagnetic, and electrical resistance tomography data; thaw depth, soil temperature and moisture content, soil texture, soil carbon and nitrogen content, and major and trace cations. Previously-collected lidar data were also available for the study. Analysis of the datasets, individually and in combination, revealed the utility of the methods for characterizing critical land-surface and subsurface properties and associated spatial zonation. Lidar analysis was performed to extract geomorphic metrics (such as slope, curvature, and directed distance of polygons), which potentially indicate drainage potential and permafrost deformation state. Cluster analysis of these lidar-obtained attributes suggested that the land surface can be grouped into three spatially coherent zones, each having a dominant geomorphic expression including: a high centered polygon zone, a low centered polygon zone and a transitional zone. Comparison of the geophysical attributes from radar, electrical resistance tomography, and electromagnetic data with point measurements suggests that the surface geophysical data can provide very high-resolution information about subsurface properties that affect ecosystem feedbacks to climate, such as thaw depth and moisture content. Cluster analysis suggested that the geophysical attributes also varied spatially in a systematic way, suggesting the presence of three laterally distinct subsurface zones. Analysis of zone-based subsurface point measurements suggests that the geophysically-defined zones have unique distributions of hydrological, thermal, and geochemical properties and that the subsurface (geophysically-based) and land-surface (lidar-based) zonation is consistent. Although the close linkage between land surface (polygonal geomorphology) and subsurface (active layer) variability revealed through our study is not surprising, to our knowledge this is the first study to document such relationships using high resolution and non-invasive approaches. This study suggests the potential of using coincident lidar and surface geophysical measurements to quantify land surface and subsurface properties (respectively) and their linkages, which are likely to play a role in terrestrial ecosystem evolution and feedbacks to climate. These findings open the way for future research focused on using combined geophysical and remote sensing datasets to estimate subsurface and land-surface properties in high resolution and over large regions as is needed for process understanding and numerical model initialization in high latitude terrestrial ecosystems.

Climate↗

Extended cavity laser absorption spectroscopy

Technologies for detecting absorption of electromagnetic radiation traveling through a measurement volume of interest are described herein. In a general embodiment, a laser is used to emit electromagnetic radiation through the measurement volume where absorption is desirably detected. An optical collector receives a portion of the radiation and directs a first fraction of the portion back to a gain medium of the laser, where the radiation is amplified and emitted again, and directs a second fraction to an optical sensor that can detect absorption in the measurement volume based upon attenuation of energy of the radiation. As the radiation feeds back to the gain medium and is emitted again, energy at attenuated wavelengths is amplified less than at other wavelengths. Thus, attenuation of energy of the radiation due to absorption in the measurement volume is cumulative, and relatively small absorptions are amplified, allowing smaller absorptions to be detected more easily.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of two-photon exchange effect with CLAS

The structure of the proton is one the most important and most studied topics in nuclear physics. However, discrepant measurements of the proton's electromagnetic form factor ratio, G{sub E}/G{sub M}, seriously jeopardize a definitive understanding of the proton's structure. Measurements of G{sub E}G{sub M} using the Rosenbluth separation technique disagree with those using polarization transfer methods by about a factor of three at Q{sup 2{approx}}5.6 GeV{sup 2}. It has been hypothesized that this discrepancy is due to two-photon exchange (TPE) effects that are not part of the usual radiative corrections. Theoretical corrections for the TPE effect are difficult due to the fact that a large number of excited nucleon states can contribute to the process. However, the TPE effect can be directly determined by measuring the ratio of the positron-proton to electron-proton elastic scattering cross sections, R = {sigma}(e{sup +})/{sigma}(e{sup -}), as the TPE effect changes sign with respect to the charge of the incident particle. A brief test run of a modified beamline and the CLAS detector at Jefferson Lab has resulted in the most precise measurements of the R to date. We will present results from the test run covering Q{sup 2}<0.8 GeV{sup 2} and 0.78{<=}{epsilon}{<=}0.97. In addition, the test run demonstrated the feasibility of producing a mixed electron/positron beam of good quality so that the measurements can be extended up to Q{sup 2{approx}}3.0 GeV{sup 2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The form factors of the nucleons

There has been much activity in the measurement of the elastic electromagnetic proton and neutron form factors in the last decade, and the quality of the data has been greatly improved by performing double-polarization experiments, in comparison with with previous unpolarized cross section data. Here we will review the experimental data base in view of the new results for the proton and the neutron, obtained at MIT-Bates, JLab and MAMI. The rapid evolution of phenomenological models triggered by these high-precision experiments will be discussed. In particular, the possibility that the proton is non-spherical in its ground state, and that the transverse charge density are model independently defined in the infinite momentum frame. Likewise, flavor decomposition of the nucleon form factors into dressed u and d quark form factors, may give information about the quark-diquark structure of the nucleon. The current proton radius “crisis” will also be discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Theory Overview On Form Factors

I attempt to answer the question: What do electromagnetic form factors really measure?.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scalable multiphoton quantum metrology with neither pre- nor post-selected measurements

The quantum statistical fluctuations of electromagnetic fields establish a limit, known as the shot-noise limit, on the sensitivity of optical measurements performed with classical technologies. However, quantum technologies are not constrained by this shot-noise limit. In this regard, the possibility of using every photon produced by quantum sources of light to estimate small physical parameters, beyond the shot-noise limit, constitutes one of the main goals of quantum optics. Here, we experimentally demonstrate a scalable protocol for quantum-enhanced optical phase estimation across a broad range of phases, with neither pre- nor post-selected measurements. This is achieved through the efficient design of a source of spontaneous parametric downconversion in combination with photon-number-resolving detection. The robustness of two-mode squeezed vacuum states against loss allows us to outperform schemes based on N00N states, in which the loss of a single photon is enough to remove all phase information from a quantum state. In contrast to other schemes that rely on N00N states or conditional measurements, the sensitivity of our technique could be improved through the generation and detection of high-order photon pairs. This unique feature of our protocol makes it scalable. Furthermore, our work is important for quantum technologies that rely on multiphoton interference such as quantum imaging, boson sampling, and quantum networks.

36 MATERIALS SCIENCE↗

Relationship between electromagnetic and acoustic emissions during plastic deformation of gamma-irradiated LiF monocrystals

Simultaneous measurements of acoustic emissions (AE) and electromagnetic emissions (EME) during plastic deformation and destruction under uniaxial compression along <001> direction are made on LiF monocrystals after gamma irradiation by {sup 60}Co source. The irradiation doses are 1, 2, and 10 Mrad. The EME measurements in the radio-frequency range are carried out using two types of electromagnetic sensors: (i) a simple electrical stub antenna and (ii) a toroidal inductance coil. Two checking experiments on unirradiated crystals are performed as the starting point to discover the effect of gamma irradiation on acoustic and electromagnetic emissive ability of plastically deformed ionic crystals. Unirradiated LiF monocrystals demonstrate high-intensive EME at easy glide and work hardening stages, as well as at the fracture during destruction of the sample. At radiation doses more than {approx}1 Mrad, in the active loading stage the EME of LiF monocrystals vanishes, except few individual electromagnetic pulses (only at 1 and 2 Mrad doses), which are time correlated with well-defined drop-jumps on the loading diagram and therefore can be associated with macroscopic crack openings. Moderate electromagnetic activity in irradiated crystals occurs only in the final stage of deformation at the complete fracture of the sample. Thus, after gamma irradiation the formation of polarization currents due to dynamic interaction between charged vacancies and moving dislocations is suppressed, and only EME connected with the redistribution of the free charge on the crack branches is observed. Acoustic emission diagrams of low-irradiated LiF are typical for the work hardening stage in crystals containing a great amount of strong point stoppers. At larger irradiation doses the AE diagram displays quite different behavior at low- and high-loading regions with a sharp boundary between them. The low-loading region shows poor AE activity, which changes sharply into high-active burst-like emission with an increase in loading. The boundary between two regions shifts to higher loadings with radiation dose. The higher is the radiation dose the lower is the relative intensity of AE in the high-stressed region. The physical mechanisms of EME and AE in gamma-irradiated ionic crystals are discussed.

36 MATERIALS SCIENCE↗

Mutual Inductance Level Sensor for Use in Liquid Metals

Electromagnetic instrumentation capable of measuring the level of liquid metal has been developed at Argonne National Laboratory’s (ANL) Mechanisms Engineering Test Loop (METL). The mutual inductance level sensor (MILS) utilizes the electromagnetic coupling between two coil conductors and a surrounding liquid metal to determine the level of the liquid metal. Mineral insulated cables wrapped on a stainless steel core provide a durable sensor construction. The use of a sealed stainless steel thimble isolates the sensor from the high-temperature liquid metal, allowing for easy sensor maintenance. Modern digital electronics allow for reliable and accurate operation of the sensor. Two sensor variations have been designed and fabricated, and the first variation has seen extensive testing in a non-sodium testing stand as well as in the high-temperature sodium environment of METL. Electromagnetic finite-element analysis studies have been performed using the COMSOL Magnetic Fields Solver. Regular operation of the MILS will commence following in-situ calibration of the sensors in the METL environment.

36 MATERIALS SCIENCE↗

A New Measurement of the Neutron Electric Form Factor with the Super Bigbite Spectrometer Apparatus

Protons and neutrons, collectively known as nucleons, make up the nuclei at the core of atoms which form our world. The nucleon has been under intensive study for over 100 years, and yet we still do not fully understand the internal dynamics which govern properties like its spin or its mass-which contributes to almost all of the visible mass in the universe. These dynamics are governed by quantum chromodynamics(QCD), the predictions of which are experimentally tested at high energy accelerator facilities such as Jefferson Lab. TheGEN-II experiment (E12-09-016) is one such experiment. GEN-II is part of the Super Bigbite Spectrometer (SBS) experimental form factor pro gramme taking place in Hall A at Jefferson Lab, which aims to make precision measurements of the nucleon electromagnetic form factors(EMFFs)at record high values of squared four momentum transfer ¿2. EMFFs describe the electric and magnetic moment distributions within the nucleon. They can be measured through elastic electron scattering off the nucleon, and describe the recoil response of the target nucleon at a given energy scale. GEN-II is a double polarized semi-exclusive beam target asymmetry (BTA) experiment, seeking to measure the electric form factor of the neutron,¿¿ ¿,at three new values of squared four-momentum transfer¿2 =2.92,6.74and9.82GeV². The latter two points being at record high ¿2. The form factor is determined through measuring the BTA of quasielliptical scattering of a neutron from a polarized nuclear target. The experiment utilized the CEBAF accelerator to produce longitudinally polarized electrons up to ~85% polarization, which were scattered off neutrons within a novel polarized helium-3 (³He) target. This new polarized ³He target was employed by building on the technology of its precursors which existed in similar preceding experiments. This target was designed to operate at the high luminosities typical of Hall A, and reached a record breaking combination of polarization and beam intensity known as figure of merit, three times larger than those predecessors. The SBS collaboration designed and constructed two brand new high acceptance spectrometers for these experiments, an electron arm named Bigbite (BB) and a hadron arm named Super Bigbite. Both spectrometers featured a large acceptance EM dipole magnet, and complementary detector systems. The electron arm contained gaseous electronmultipliers(GEMs) which were used for high precision tracking of the scattered electrons, a heavy gas cherenkov (GRINCH) which was used for PID between electrons and pions, a plastic i ii scintillator timing hodoscope to provide high resolution timing of the start of events, and a pair of EM calorimeters (BBCal) which provided energy measurements of detected particles, and provided the experimental trigger. The hadron arm also contained a system of GEMs which will be utilized for future SBS experiments, and a hadron calorimeter designed to provide position, timing and energy measurements of the recoiling nucleon. The calibration of all detector subsystems, beam and target data is discussed, with a focus on novel timing calibrations to the hodoscope and hadron calorimeter. An analysis of selecting quasielliptical events and suppressing background contributions from a number of sources which contaminate the final event sample is given. The largest irreducible backgrounds are found to be from misidentified protons, timing accidentals and inelastic events. The physical asymmetry is measured and used to extract a value for the form factor ratio ¿¿ ¿/¿¿ ¿. High precision ¿2 data for ¿¿ ¿ is used to then extract ¿¿ ¿. This work finds at ¿2 = 2.92 GeV2 that ¿¿ ¿ = 0.0129+0.0019 -0.0020. This result is in statistical agreement with existing fits to world data, and predictions from the constituent quark model and Dyson–Schwinger equations, in this region of ¿2.

Penman, Gary [Univ. of Glasgow, Scotland (United K↗

THE TEMPERATURE OF THE COSMIC MICROWAVE BACKGROUND

The Far InfraRed Absolute Spectrophotometer data are independently recalibrated using the Wilkinson Microwave Anisotropy Probe data to obtain a cosmic microwave background (CMB) temperature of 2.7260 +- 0.0013. Measurements of the temperature of the CMB are reviewed. The determination from the measurements from the literature is CMB temperature of 2.72548 +- 0.00057 K.

79 ASTRONOMY AND ASTROPHYSICS↗

Reconstructing the massive black hole cosmic history through gravitational waves

The massive black holes we observe in galaxies today are the natural end-product of a complex evolutionary path, in which black holes seeded in proto-galaxies at high redshift grow through cosmic history via a sequence of mergers and accretion episodes. Electromagnetic observations probe a small subset of the population of massive black holes (namely, those that are active or those that are very close to us), but planned space-based gravitational wave observatories such as the Laser Interferometer Space Antenna (LISA) can measure the parameters of 'electromagnetically invisible' massive black holes out to high redshift. In this paper we introduce a Bayesian framework to analyze the information that can be gathered from a set of such measurements. Our goal is to connect a set of massive black hole binary merger observations to the underlying model of massive black hole formation. In other words, given a set of observed massive black hole coalescences, we assess what information can be extracted about the underlying massive black hole population model. For concreteness we consider ten specific models of massive black hole formation, chosen to probe four important (and largely unconstrained) aspects of the input physics used in structure formation simulations: seed formation, metallicity ''feedback'', accretion efficiency and accretion geometry. For the first time we allow for the possibility of 'model mixing', by drawing the observed population from some combination of the 'pure' models that have been simulated. A Bayesian analysis allows us to recover a posterior probability distribution for the ''mixing parameters'' that characterize the fractions of each model represented in the observed distribution. Our work shows that LISA has enormous potential to probe the underlying physics of structure formation.

79 ASTRONOMY AND ASTROPHYSICS↗

Engineered optical fibers and uses thereof

A system comprises an electromagnetic radiation source, a polarizing element, a mode converter, an optical fiber, and a measurement device. The polarizing element receives electromagnetic radiation produced by the electromagnetic radiation source and outputs linearly-polarized electromagnetic radiation having a linear polarization angle θ1. The mode converter converts the linearly-polarized electromagnetic radiation to an orbital angular momentum (OAM) mode of linearly-polarized electromagnetic radiation with topological charge Li. The OAM mode of linearly-polarized electromagnetic radiation is a superposition of first and second OAM modes with topological charges Li and opposite circular polarizations. The optical fiber supports propagation of the first and second OAM modes with an absolute effective index difference Δneff greater than or equal to 5×10−5, such that linearly-polarized electromagnetic radiation with linear polarization angle θ2 is emitted by the optical fiber. The measurement device is configured to determine a property of the electromagnetic radiation based on the polarization angle θ2.

Ramachandran, Siddharth↗

Final analysis of proton form factor ratio data at Q 2 = 4.0, 4.8, and 5.6 GeV 2

Recently published measurements of the proton electromagnetic form factor ratio R = μ p G E p /G M p at momentum transfers Q 2 up to 8.5 GeV 2 in Jefferson Lab Hall C deviate from the linear trend of previous measurements in Jefferson Lab Hall A, favoring a slower rate of decrease of R with Q 2 . While statistically compatible in the region of overlap with Hall A, the Hall C data hint at a systematic difference between the two experiments. This possibility was investigated in a reanalysis of the Hall A data. We find that the original analysis underestimated the background in the selection of elastic events. The application of an additional cut to further suppress the background increases the results for R, improving the consistency between Halls A and C.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗