Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Printed Circuit Board Based Rotating Coils for Measuring Sextupole Magnets

Here, the use of Printed Circuit Boards (PCBs) for the inductive pick-up windings of rotating coil probes has made the construction of these precision magnetic measurement devices much more accessible. This paper discusses the design details for PCBs which on each layer of the board provide for simultaneous analog bucking (suppression) of dipole, quadrupole, and sextupole field components so as to more accurately measure the higher order harmonic fields in sextupole magnets. Techniques to generate designs are discussed, as well as trade-offs to optimize sensitivity. Examples of recent sextupole PCBs and their performance are given.

43 PARTICLE ACCELERATORS↗

Magnetic Measurements and Alignment Results of LQXFA/B Cold Mass Assemblies at Fermilab

MQXFA production series quadrupole magnets are being built for the Hi-Lumi (HL) LHC upgrade by the U.S. Accelerator Upgrade Project (US-HL-LHC AUP). These magnets are being placed in pairs, as a cold mass, within cryostats at Fermilab, and are being tested to assess alignment and magnetic performance at Fermilab's horizontal test stand facility. The ~10 m - long assembly must meet stringent specifications for quadrupole strength and harmonic field integrals determination, magnetic axis position, and for magnet variations in positioning and local field profile. Here this paper describes the results of the magnetic and alignment measurements which characterize the first LQXFA/B assembly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the phase between strong and electromagnetic amplitudes in the decay J/ψ → ϕη

The first direct measurement of the relative phase between the strong and electromagnetic amplitudes for a J/ψ decaying into a vector-pseudoscalar final state is performed using 26 energy points of e + e − annihilation data between 3.00 GeV and 3.12 GeV. The data sets were collected by the BESIII detector with a total integrated luminosity of 452 pb −1 . By investigating the interference pattern in the cross section lineshape of e + e − → ϕη, the relative phase between the strong and electromagnetic amplitudes of J/ψ decay is determined to be within [133°, 228°] at 68% confidence level.

QCD↗

Electromagnetic Properties of (Gd, Y)Ba2Cu3Ox Superconducting Tapes With High Levels of Zr Addition

The dependence of the critical current density (J(c)) on the orientation of applied magnetic fields was studied in Zr-doped (Gd, Y)Ba2Cu3Ox tapes fabricated by metal organic chemical vapor deposition. The in-field performance of J(c) of (Gd, Y)Ba2Cu3Ox tapes with Zr-doping levels of 7.5-30 at.% was investigated up to 5 T over a temperature range of 40-77 K. The highest critical currents (I-c) at H parallel to c and the highest values of minimum Ic in angular dependence measurements were achieved in the tapes with 20% Zr doping over a broad range of temperature and magnetic field conditions measured. The electromagnetic properties have been related to the changes in BaZrO3 content and microstructure.

Liu, Y↗

FD-TD numerical simulation of an entire lightning strike on the C160 aircraft

Experimental transient electromagnetic field measurements were performed on a Transall C160 aircraft during in-flight lightning strikes. The data allow a test of the predictive capabilities of a three dimensional time domain finite difference code (ALICE) developed at ONERA in order to investigate lightning-aircraft interactions. Using a transfer function technique in the 3D code, it is shown that a bi-leader attached to an aircraft can be simulated by a linear model, and so the electromagnetic fields can be calculated anywhere on the vehicle. Comparison of experimental and numerical results were made for several lightning strikes. Skin current density and electromagnetic field distributions are discussed in detail.

Alliot, J. C.↗

Research in remote sensing of vegetation

The research topics undertaken were primarily selected to further the understanding of fundamental relationships between electromagnetic energy measured from Earth orbiting satellites and terrestrial features, principally vegetation. Vegetation is an essential component in the soil formation process and the major factor in protecting and holding soil in place. Vegetation plays key roles in hydrological and nutrient cycles. Awareness of improvement or deterioration in the capacity of vegetation and the trends that those changes may indicate are, therefore, critical detections to make. A study of the relationships requires consideration of the various portions of the electromagnetic spectrum; characteristics of detector system; synergism that may be achieved by merging data from two or more detector systems or multiple dates of data; and vegetational characteristics. The vegetation of Oregon is sufficiently diverse as to provide ample opportunity to investigate the relationships suggested above several vegetation types.

Schrumpf, Barry J.↗

First Field Measurements of the 15 T Nb 3 Sn Dipole Demonstrator MDPCT1

Within the US Magnet Development Program (MDP) a 15 T Nb 3 Sn dipole was developed, to demonstrate a magnet design for a post-LHC pp Collider. Specifically, the magnet design is based on 60 mm aperture 4-layer shell-type coils, graded between the inner and outer layers to maximize the magnet performance. The cable in the two innermost layers has 28 strands 1.0 mm in diameter and the cable in the two outermost layers has 40 strands 0.7 mm in diameter. Both cables use RRP Nb3Sn wires produced by Bruker-OST. Magnet coils are surrounded by vertically-split thick iron laminations, con-nected by aluminum I-clamps, and a thick stainless-steel skin. The magnet was tested at the Vertical Magnet Test Facility (VMTF) at Fermilab. This paper reports the first results of magnetic measure-ments of the 15 T Nb 3 Sn dipole demonstrator including geometrical harmonics, coil magnetization and iron saturation effects. The ex-perimental data are compared with the magnetic calculations.

43 PARTICLE ACCELERATORS↗

Constraining nuclear matter parameters with GW170817

The tidal measurement of gravitational waves from the binary neutron star merger event GW170817 allows us to probe nuclear physics that suffers less from astrophysical systematics compared to neutron star radius measurements with electromagnetic wave observations. Recent research found strong correlation among neutron-star tidal deformabilities and certain combinations of nuclear parameters associated with the equation of state. These relations were then used to derive bounds on such parameters from GW170817 assuming that the relations and neutron star masses are known exactly. In this work, we expand on this important work by taking into account a few new considerations: (1) a broader class of equations of state; (2) correlations with the mass-weighted tidal deformability that was directly measured with GW170817; (3) how the relations depend on the binary mass ratio; (4) the uncertainty from equation of state variation in the correlation relations; (5) adopting the updated posterior distribution of the tidal deformability measurement from GW170817. Upon these new considerations, we find GW170817 90% confidence intervals on nuclear parameters (the incompressibility K 0 , its slope M 0 , and the curvature of symmetry energy K sym,0 at nuclear saturation density) to be 81 MeV ≤K 0 ≤362 MeV, 1556 MeV ≤M 0 ≤ 4971 MeV, and -259 MeV ≤Ksym, 0 ≤32 MeV, which are more conservative than previously found with systematic errors more properly taken into account.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of a 170-GHz frequency doubler with an array of planar diodes

Analysis of a planar diode multiplier from 85-170 GHz is described. The doubler uses a waveguide mount with two series pairs of diodes in a balanced structure. Because of the difficulties in conventional scale model measurements, numerical electromagnetic simulation based on the finite element method was chosen for the analysis, using a commercial program. To optimize the diode design, the de-embedded diode terminal impedance was studied, as well as the power balance between the diodes. The analysis showed that the matching of the diode impedance to that of the waveguide is quite sensitive to the diode substrate thickness. Thicknesses from 25-100 micron in GaAs were studied as well as 100-micron-thick quartz. The accuracy of the theoretical analysis was verified by careful measurements using a slotted line to determine the diode terminal impedance under large signal pump, for frequencies between 80 and 90 GHz. Good agreement between the measured and simulated diode terminal impedance was observed, although full agreement requires the addition of an empirical loss term. Several options are considered for the source of this loss.

DIODE MULTIPLIER↗

Probe Station and Near-Field Scanner for Testing Antennas

A facility that includes a probe station and a scanning open-ended waveguide probe for measuring near electromagnetic fields has been added to Glenn Research Center's suite of antenna-testing facilities, at a small fraction of the cost of the other facilities. This facility is designed specifically for nondestructive characterization of the radiation patterns of miniaturized microwave antennas fabricated on semiconductor and dielectric wafer substrates, including active antennas that are difficult to test in traditional antenna-testing ranges because of fragility, smallness, or severity of DC-bias or test-fixture requirements. By virtue of the simple fact that a greater fraction of radiated power can be captured in a near-field measurement than in a conventional far-field measurement, this near-field facility is convenient for testing miniaturized antennas with low gains.

Zaman, Afroz↗

The Effects of the Local Environment on a Compact Radio Interferometer I: Cross-Coupling in the Tianlai Dish Pathfinder Array

The visibilities measured by radio astronomical interferometers include non-astronomical correlated signals that arise from the local environment of the array. These correlated signals are especially important in compact arrays such as those under development for 21cm intensity mapping. The amplitudes of the contaminated visibilities can exceed the expected 21cm signal and represent a significant systematic effect. We study the receiver noise radiated by antennas in compact arrays and develop a model for how it couples to other antennas. We apply the model to the Tianlai Dish Pathfinder Array (TDPA), a compact array of 16, 6-m dish antennas. The coupling model includes electromagnetic simulations, measurements with a network analyzer, and measurements of the noise of the receivers. We compare the model to drift-scan observations with the array and set requirements on the level of antenna cross-coupling for 21cm intensity mapping instruments. Here, we find that for the TDPA, cross-coupling would have to be reduced by three orders of magnitude in order to contribute negligibly to the visibilities.

21cm intensity mapping↗

Robust electromagnetically guided endoscopic procedure using enhanced particle swarm optimization for multimodal information fusion

Purpose: Electromagnetically guided endoscopic procedure, which aims at accurately and robustly localizing the endoscope, involves multimodal sensory information during interventions. However, it still remains challenging in how to integrate these information for precise and stable endoscopic guidance. To tackle such a challenge, this paper proposes a new framework on the basis of an enhanced particle swarm optimization method to effectively fuse these information for accurate and continuous endoscope localization. Methods: The authors use the particle swarm optimization method, which is one of stochastic evolutionary computation algorithms, to effectively fuse the multimodal information including preoperative information (i.e., computed tomography images) as a frame of reference, endoscopic camera videos, and positional sensor measurements (i.e., electromagnetic sensor outputs). Since the evolutionary computation method usually limits its possible premature convergence and evolutionary factors, the authors introduce the current (endoscopic camera and electromagnetic sensor’s) observation to boost the particle swarm optimization and also adaptively update evolutionary parameters in accordance with spatial constraints and the current observation, resulting in advantageous performance in the enhanced algorithm. Results: The experimental results demonstrate that the authors’ proposed method provides a more accurate and robust endoscopic guidance framework than state-of-the-art methods. The average guidance accuracy of the authors’ framework was about 3.0 mm and 5.6° while the previous methods show at least 3.9 mm and 7.0°. The average position and orientation smoothness of their method was 1.0 mm and 1.6°, which is significantly better than the other methods at least with (2.0 mm and 2.6°). Additionally, the average visual quality of the endoscopic guidance was improved to 0.29. Conclusions: A robust electromagnetically guided endoscopy framework was proposed on the basis of an enhanced particle swarm optimization method with using the current observation information and adaptive evolutionary factors. The authors proposed framework greatly reduced the guidance errors from (4.3, 7.8) to (3.0 mm, 5.6°), compared to state-of-the-art methods.

60 APPLIED LIFE SCIENCES↗

Electromagnetic bias of 36-GHz radar altimeter measurements of MSL

The data reduction techniques used to determine the magnitude of electromagnetic (EM) bias in radar altimeter measurements of mean sea level (MSL) area described. Particular attention is given to the bias reduction scheme developed specifically for the Surface Contour Radar (SCR) instrument of the Ocean Topography Experiment (TOPEX). The SCR makes it possible to determine the amount of the backscattered power due to EM reflectance per unit area by measuring both the return power and elevation. Variations of backscattered power for different sea states are determined as a function of displacement of the MSL. On the basis of the recent SCR observations from aircraft, a standard error due to EM bias is predicted for MSL measurements performed with a satellite altimeter radar operating at a frequency of 36 GHz. The obtained standard error was 1 percent for regions with waves 1.9-5.5 meters in height.

Walsh, E. J.↗

Performance and Commissioning of the BigBite Timing Hodoscope for Nucleon Form Factor Measurements at Jefferson Lab

The BigBite Timing Hodoscope detector is the primary subject of this thesis. The Super BigBite Spectrometer is a Jefferson Lab Hall A Collaboration project that has and will continue to measure nucleon electromagnetic form factors. This spectrometer includes the Timing Hodoscope which provides high resolution particle timing data for scattered electrons in the electron arm of BigBite. The Timing Hodoscope utilizes 90, 25 × 25 × 600 mm3 scintillator bars stacked on top of each other to form a single detector plane, and these bars are connected to 180 photo-multiplier tubes via light guides. Particles collide with the scintillating material creating a shower of optical photons and these particle events in the bars are collected to generate signals that are readout by the data acquisition (DAQ) electronics. NINO ASIC amplifier-discriminator cards output signals from the photo-multiplier tubes into analogue and logic signals, which are sent to analogue-to-digital (ADC) and time-to-digital (TDC) converter data acquisition readout modules. This data is then used for analysis of the detector. The focus of this thesis is the construction, commissioning, calibration, and performance of the BigBite Timing Hodoscope before and during the first of five nucleon electromagnetic form factor experiments at Jefferson Lab Hall A. Before the neutron magnetic form factor, G n M, experiment, cosmic ray data was collected during commissioning to confirm proper operation of the Timing Hodoscope electronics by observing the ADC and TDC data. Commissioning studies for charge normalization, gain matching, and other ADC and TDC detector data variables were performed before moving the detector into Hall A. Following installation in Hall A, several calibration studies were implemented to fine-tune the detector in preparation for use in the experiment. The calibration studies included analysis of timing cuts, TDC alignment, the time-walk effect, time difference offsets, and scintillator velocity corrections. Once the Timing Hodoscope was well-calibrated, data-taking during the experiment commenced and the beam-on-target data was used to characterize the Timing Hodoscope performance during the G n M experiment run-time. The performance analysis included studies observing energy deposit, cluster size, rates, accidentals, pile-up, tracking efficiency, position resolution, and time resolution. After application of physics cuts to ensure a data set comprised of particle tracks corresponding to elastic electrons, which is the main data of interest for measurement of G n M, the Timing Hodoscope is shown on average across all kinematic settings to have a >98% tracking efficiency, a position resolution of 4-6 cm in the non-dispersive plane and 1.5-2 cm in the dispersive plane, and a time resolution of 500-750 ps. These performance results are compared to a GEANT4 based performance simulation of the BigBite Timing Hodoscope for reference, showing to what degree the measured performance values match those taken from the simulation.

Marinaro, Ralph↗

Structural trends in atomic nuclei from laser spectroscopy of tin

Tin is the chemical element with the largest number of stable isotopes. Its complete proton shell, comparable with the closed electron shells in the chemically inert noble gases, is not a mere precursor to extended stability; since the protons carry the nuclear charge, their spatial arrangement also drives the nuclear electromagnetism. We report high-precision measurements of the electromagnetic moments and isomeric differences in charge radii between the lowest 1/2 + , 3/2 + , and 11/2 - states in 117–131 Sn, obtained by collinear laser spectroscopy. Supported by state-of-the-art atomic-structure calculations, the data accurately show a considerable attenuation of the quadrupole moments in the closed-shell tin isotopes relative to those of cadmium, with two protons less. Linear and quadratic mass-dependent trends are observed. While microscopic density functional theory explains the global behaviour of the measured quantities, interpretation of the local patterns demands higher-fidelity modelling.

74 ATOMIC AND MOLECULAR PHYSICS↗

Pulsed electromagnetic gas acceleration

Detailed measurements of the axial velocity profile and electromagnetic structure of a high power, quasi-steady MPD discharge are used to formulate a gasdynamic model of the acceleration process. Conceptually dividing the accelerated plasma into an inner flow and an outer flow, it is found that more than two-thirds of the total power in the plasma is deposited in the inner flow, accelerating it to an exhaust velocity of 12.5 km/sec. The outer flow, which is accelerated to a velocity of only 6.2 km/sec, appears to provide a current conduction path between the inner flow and the anode. Related cathode studies have shown that the critical current for the onset of terminal voltage fluctuations, which was recently shown to be a function of the cathode area, appears to reach an asymptote for cathodes of very large surface area. Detailed floating potential measurements show that the fluctuations are confined to the vicinity of the cathode and hence reflect a cathode emission process rather than a fundamental limit on MPD performance.

Jahn, R. G.↗

Electrical properties of methane hydrate + sediment mixtures: The σ of CH 4 Hydrate + Sediment

Knowledge of the electrical properties of multicomponent systems with gas hydrate, sediments, and pore water is needed to help relate electromagnetic (EM) measurements to specific gas hydrate concentration and distribution patterns in nature. We built a pressure cell capable of measuring in situ electrical properties of multicomponent systems such that the effects of individual components and mixing relations can be assessed. We first established the temperature-dependent electrical conductivity (σ) of pure, single-phase methane hydrate to be ~5 orders of magnitude lower than seawater, a substantial contrast that can help differentiate hydrate deposits from significantly more conductive water-saturated sediments in EM field surveys. We report σ measurements of two-component systems in which methane hydrate is mixed with variable amounts of quartz sand or glass beads. Sand by itself has low σ but is found to increase the overall σ of mixtures with well-connected methane hydrate. Alternatively, the overall σ decreases when sand concentrations are high enough to cause gas hydrate to be poorly connected, indicating that hydrate grains provide the primary conduction path. Our measurements suggest that impurities from sand induce chemical interactions and/or doping effects that result in higher electrical conductivity with lower temperature dependence. Finally, these results can be used in the modeling of massive or two-phase gas-hydrate-bearing systems devoid of conductive pore water. Further experiments that include a free water phase are the necessary next steps toward developing complex models relevant to most natural systems.

03 NATURAL GAS↗

Vertical Architecture Solution-Processed Quantum Dot Photodetectors with Amorphous Selenium Hole Transport Layer

Colloidal quantum dots (CQDs) provide wide spectral tunability and high absorption coefficients owing to quantum confinement and large oscillator strengths, which along with solution processability, allow a facile, low-cost, and room-temperature deposition technique for the fabrication of photonic devices. However, many solution-processed CQD photodetector devices demonstrate low specific-detectivity and slow temporal response. To achieve improved photodetector characteristics, limiting carrier recombination and enhancing photogenerated carrier separation are crucial. In this study, we develop and present an alternate vertical-stack photodetector wherein we use a solution-processed quantum dot photoconversion layer coupled to an amorphous selenium (a-Se) wide-bandgap charge transport layer that is capable of exhibiting single-carrier hole impact ionization and is compatible with active-matrix readout circuitry. This a-Se chalcogenide transport layer enables the fabrication of high-performance and reliable solution-processed quantum dot photodetectors, with enhanced charge extraction capabilities, high specific detectivity (D* ~ 0.5–5 × 10 12 Jones), fast 3 dB electrical bandwidth (3 dB BW ~ 22 MHz), low dark current density (J D ~ 5–10 pA/cm 2 ), low noise current (i n ~ 20–25 fW/Hz 1/2 ), and high linear dynamic range (LDR ~130–150 dB) across the measured visible electromagnetic spectrum (~405–656 nm).

77 NANOSCIENCE AND NANOTECHNOLOGY↗