Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Wide-field microwave magnetic field imaging with nitrogen-vacancy centers in diamond

Non-invasive imaging of microwave (MW) magnetic fields with microscale lateral resolution is pivotal for various applications, such as MW technologies and integrated circuit failure analysis. Diamond nitrogen-vacancy (NV) center magnetometry has emerged as an ideal tool, offering micrometer-scale resolution, millimeter-scale field of view, high sensitivity, and non-invasive imaging compatible with diverse samples. However, up until now, it has been predominantly used for imaging of static or low-frequency magnetic fields or, concerning MW field imaging, to directly characterize the same microwave device used to drive the NV spin transitions. In this work, we leverage an NV center ensemble in diamond for wide-field imaging of MW magnetic fields generated by a test device employing a differential measurement protocol. The microscope is equipped with a MW loop to induce Rabi oscillations between NV spin states, and the MW field from the device-under-test is measured through local deviations in the Rabi frequency. This differential protocol yields magnetic field maps of a 2.57 GHz MW field with a sensitivity of ∼9 μT Hz −1/2 for a total measurement duration of T=357 s, covering a 340 × 340 μm 2 field of view with a micrometer-scale spatial resolution and a device-under-test input power dynamic range of 30 dB. This work demonstrates a novel NV magnetometry protocol, based on differential Rabi frequency measurement, that extends NV wide-field imaging capabilities to imaging of weak MW magnetic fields that would be difficult to measure directly through standard NV Rabi magnetometry.

crystallographic defects↗

New generation bunch shape monitor for ion accelerators

Measuring longitudinal beam parameters is important for operation and development of high intensity linear accelerators, but it is notoriously difficult for proton and ion beams at non-relativistic energies. The Bunch Shape Monitor (BSM) is a device used for measuring the longitudinal bunch distribution in ion linacs. The existing BSM models have poor electron collection efficiency from the wire and are limited to one-dimensional measurements of the phase coordinate. In response to this problem, we have developed a new generation BSM with improved performance. The proposed design incorporates three major innovations: First, the collection efficiency was improved by adding a focusing field between the wire and the entrance slit, which will also allow measurements over a much wider dynamic range. Second, an improvement in the measurement speed was achieved by sampling longitudinal profiles of multiple energy slices simultaneously, where the BSM wire is placed at the exit of an ion spectrometer so that ions with different energies hit the wire at different horizontal coordinates along the wire. Finally, the design incorporates a motion system that can shift the wire and deflecting cavity together, enabling transverse profile measurements like a wire scanner. Here, in this paper, we will provide the design of the new BSM and report on its beam test results at the Spallation Neutron Source facility in Oak Ridge National Laboratory.

43 PARTICLE ACCELERATORS↗

Adaptive nonequilibrium design of actin-based metamaterials: Fundamental and practical limits of control

The adaptive and surprising emergent properties of biological materials self-assembled in far-from-equilibrium environments serve as an inspiration for efforts to design nanomaterials. In particular, controlling the conditions of self-assembly can modulate material properties, but there is no systematic understanding of either how to parameterize external control or how controllable a given material can be. Here, we demonstrate that branched actin networks can be encoded with metamaterial properties by dynamically controlling the applied force under which they grow and that the protocols can be selected using multi-task reinforcement learning. These actin networks have tunable responses over a large dynamic range depending on the chosen external protocol, providing a pathway to encoding “memory” within these structures. Interestingly, we obtain a bound that relates the dissipation rate and the rate of “encoding” that gives insight into the constraints on control—both physical and information theoretical. Taken together, these results emphasize the utility and necessity of nonequilibrium control for designing self-assembled nanostructures.

59 BASIC BIOLOGICAL SCIENCES↗

Dissecting neurofilament tail sequence-phosphorylation-structure relationships with multicomponent reconstituted protein brushes

Neurofilaments (NFs) are multisubunit, bottlebrush-shaped intermediate filaments abundant in the axonal cytoskeleton. Each NF subunit contains a long intrinsically disordered tail domain, which protrudes from the NF core to form a “brush” surrounding each NF. Precisely how the tails’ variable charge patterns and repetitive phosphorylation sites mediate their conformation within the brush remains an open question in axonal biology. We address this problem by grafting recombinant NF tail protein constructs NF-Light, -Medium, and -Heavy (NFL, NFM, and NFH) to surfaces, yielding protein brushes of defined stoichiometry that can be phosphorylated in vitro. Atomic force microscopy measurements reveal that brush height depends on composition monotonically but not always linearly for binary NFL:NFM or NFL:NFH systems, and that NFM-based brushes are highly extended, while brushes incorporating the much larger NFH are surprisingly compact even after multisite phosphorylation. Complementary self-consistent field theory (SCFT) predicts multilayer brush morphologies for NFM and phosphorylated NFH brushes. Further experiments and SCFT analysis with designed mutants reveal that N-terminal negative charges in the NFH tail repel phosphorylated residues to generate the multilayer morphology, while the C-terminal charge-neutral region contributes to multilayer brush morphology but not total brush height. Charge-shuffled NFM variants show that charge segregation promotes brush collapse near physiological ionic strengths. Collectively, this study supports a role for NFM in establishing a dynamic range for NF brush conformation, lending insight into previous in vitro and in vivo findings. More broadly, this work establishes a platform for dissecting contributions of disordered protein sequence to conformation at interfaces.

Science & Technology - Other Topics↗

Bistable random momentum transfer in a linear on-chip resonator

Optical switches and bifurcation rely on the nonlinear response of materials. Here, we demonstrate linear temporal bifurcation responses in a passive multimode microresonator, with strongly coupled chaotic and whispering gallery modes (WGMs). In microdisks, the chaotic modes exhibit broadband transfer within the deformed cavities, but their transient response is less explored and yields a random output of the analog signal distributed uniformly from “0” to “1.” Here, we build chaotic states by perturbing the multimode microring resonators with densely packed silicon nanocrystals on the waveguide surface. In vivo measurements reveal random and “digitized” output that ONLY populates around 0 and 1 intensity levels. The bus waveguide mode couples first to chaotic modes, then either dissipates or tunnels into stable WGMs. This binary pathway generates high-contrast, digitized outputs. In conclusion, the fully passive device enables real-time conversion of periodic clock signals into binary outputs with contrasts exceeding 12.3 dB, data rates of up to 10 7 · bits per second, and 20 dB dynamic range.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Enhancements to the New TREAT Automatic Reactor Control System (ARCS)

The Transient Reactor Test (TREAT) facility recently replaced the automatic reactor control system (ARCS). Here, this paper discusses some of the enhancements that were made during the ARCS replacement such as calculations to take into account the nonadiabatic effects and increasing the dynamic range for power and period indication. This paper also discusses upgrades that had been planned but were unable to implemented and potential upgrades for the future.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In-line measurements of below-the-surface food deformation during drying with an interference-based optical fiber strain sensor

Real-time measurements of food deformation are important for quality control in drying, yet they pose significant challenges. In this study, we developed an interference-based optical fiber strain sensor to enable in-line, continuous, below-the-surface strain measurements in drying of soft food samples. Compared to a strain resolution of 8 × 10 -4 at zero strain and 7.2 × 10 -3 at 0.20 strain reported in our previously published work, the present study achieves markedly improved resolutions of 1.3 × 10 -4 at zero strain and 7.8 × 10 -4 at 0.25 strain, which strains are the lower and higher boundaries of the dynamic range, respectively. This nearly order-of-magnitude improvement is attributed to the unique interference-based sensing mechanism, no need for calibration to convert optical signals to strain, and the system-design-enabled immunity to fiber-disk misalignments and light source intensity fluctuations. To demonstrate the in-line process monitoring, deformation measurements of fresh banana slices and sugar cookie doughs were carried out in a benchtop oven and an industrial-scale hot-air pilot dryer, respectively. In both dryers, strain measurements were continuously measured during the whole drying process at various depths and radii below the sample surfaces, with the strains up to 25%. Computer vision was used only in the benchtop drying to confirm the faithfulness of the fiber sensor measurements and cannot provide below-the-surface measurements. The measured spatiotemporal deformation allowed us to confirm the shell-hardening effect and to determine the speed and location of large deformation changes in the whole drying process, the latter of which is related to the sample cracking. To the best of the authors’ knowledge, this study is the first to report on an interferometry-based fiber sensor to measure food deformation. This sensor and the sensing mechanism have high potential for real-time process monitoring and control to prevent over-drying or cracking during drying processes.

47 OTHER INSTRUMENTATION↗

Emerging protein sequencing technologies: proteomics without mass spectrometry?

Liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been a leading method for proteomics for 30 years. Advantages provided by LC-MS/MS are offset by significant disadvantages, including cost. Recently, several non-mass spectrometric methods have emerged, but little information is available about their capacity to analyze the complex mixtures routine for mass spectrometry. Areas Covered: We review recent non-mass-spectrometric methods for sequencing proteins and peptides, including those using nanopores, sequencing by degradation, reverse translation, and short-epitope mapping, with comments on bioinformatics challenges, fundamental limitations, and areas where new technologies will be more or less competitive with LC-MS/MS. In addition to conventional literature searches, instrument vendor websites, patents, webinars, and preprints were also consulted to give a more up-to-date picture. Expert Opinion: Many new technologies are promising. However, demonstrations that they outperform mass spectrometry in terms of peptides and proteins identified have not yet been published, and astute observers note important disadvantages, especially relating to the dynamic range of single-molecule measurements of complex mixtures. Still, even if the performance of emerging methods proves inferior to LC-MS/MS, their low cost could create a different kind of revolution: a dramatic increase in the number of biology laboratories engaging in new forms of proteomics research.

59 BASIC BIOLOGICAL SCIENCES↗

Time-resolved particle image velocimetry

Time-resolved particle image velocimetry (TR-PIV) has become widespread in fluid dynamics. Essentially a velocity field movie, the dynamic content provides temporal as well as spatial information, in contrast to conventional PIV offering only statistical ensembles of flow quantities. From these time series arise further analyses such as accelerometry, space-time correlations, frequency spectra of turbulence including spatial variability, and derivation of pressure fields and forces. The historical development of TR-PIV is chronicled, culminating in an assessment of the current state of technology in high-repetition-rate lasers and high-speed cameras. Commercialization of pulse-burst lasers has expanded TR-PIV into more flows, including the compressible regime, and has achieved MHz rates. Particle response times and peak locking during image interrogation require attention but generally are not impediments to success. Accuracy considerations are discussed, including the risks of noise and aliasing in spectral content. Oversampled TR-PIV measurements allow use of multi-frame image interrogation methods, which improve the precision of the correlation and raise the velocity dynamic range of PIV. In combination with volumetric methods and data assimilation, a full four-dimensional description of a flow is not only achievable but becoming standardized. Lastly, a survey of exemplary applications is followed by a few predictions concerning the future of TR-PIV.

47 OTHER INSTRUMENTATION↗

Photon number resolving detection with a single-photon detector and adaptive storage loop

Abstract Photon number resolving (PNR) measurements are beneficial or even necessary for many applications in quantum optics. Unfortunately, PNR detectors are usually large, slow, expensive, and difficult to operate. However, if the input signal is multiplexed, photon ‘click’ detectors, that lack an intrinsic PNR capability, can still be used to realize photon number resolution. Here, we investigate the operation of a single click detector, together with a storage line with tunable outcoupling. Using adaptive feedback to adjust the storage outcoupling rate, the dynamic range of the detector can in certain situations be extended by up to an order of magnitude relative to a purely passive setup. An adaptive approach can thus allow for photon number variance below the quantum shot noise limit under a wider range of conditions than using a passive multiplexing approach. This can enable applications in quantum enhanced metrology and quantum computing.

Sullivan, Nicholas M. (ORCID:0000000248447296)↗

Accurate predictions from small boxes: variance suppression via the Zel'dovich approximation

Simulations have become an indispensable tool for accurate modelling of observables measured in galaxy surveys, but can be expensive if very large dynamic range in scale is required. We describe how to combine Lagrangian perturbation theory models with N-body simulations to reduce the effects of finite computational volume in the prediction of ensemble average properties in the simulations within the context of control variates. In particular we use the fact that Zel'dovich displacements, computed during initial condition generation for any simulation, correlate strongly with the final density field. Since all the correlators of biased tracers can be computed with arbitrary precision for these displacements, pairing the Zel'dovich `simulation' with the N-body realization allows hundredfold reductions in sample variance for power spectrum or correlation function estimation. Additionally, Zel'dovich control variates can accurately extend matter or tracer field emulators to larger scales than previously possible, as well as improving measurements of statistics in simulations which are inherently limited to small volumes, such as hydrodynamical simulations of galaxy formation and reionization.

79 ASTRONOMY AND ASTROPHYSICS↗

Precision redshift-space galaxy power spectra using Zel'dovich control variates

Numerical simulations in cosmology require trade-offs between volume, resolution and run-time that limit the volume of the Universe that can be simulated, leading to sample variance in predictions of ensemble-average quantities such as the power spectrum or correlation function(s). Sample variance is particularly acute at large scales, which is also where analytic techniques can be highly reliable. This provides an opportunity to combine analytic and numerical techniques in a principled way to improve the dynamic range and reliability of predictions for clustering statistics. In this paper we extend the technique of Zel'dovich control variates, previously demonstrated for 2-point functions in real space, to reduce the sample variance in measurements of 2-point statistics of biased tracers in redshift space. We demonstrate that with this technique, we can reduce the sample variance of these statistics down to their shot-noise limit out to k ~ 0.2 h Mpc -1 . This allows a better matching with perturbative models and improved predictions for the clustering of e.g. quasars, galaxies and neutral Hydrogen measured in spectroscopic redshift surveys at very modest computational expense. We discuss the implementation of ZCV, give some examples and provide forecasts for the efficacy of the method under various conditions.

79 ASTRONOMY AND ASTROPHYSICS↗

Multi-amplifier Sensing Charge-coupled Devices for Next Generation Spectroscopy

We present characterization results and performance of a prototype Multiple-Amplifier Sensing (MAS) silicon charge-coupled device (CCD) sensor with 16 channels potentially suitable for faint object astronomical spectroscopy and low-signal, photon-limited imaging. The MAS CCD is designed to reach sub-electron readout noise by repeatedly measuring charge through a line of amplifiers during the serial transfer shifts. Using synchronized readout electronics based on the Dark Energy Spectroscopic Instrument CCD controller, we report a read noise of 1.03 e$^{−}$ rms pix$^{−1}$ at a speed of 26 μs pix$^{−1}$ with a single-sample readout scheme where charge in a pixel is measured only once for each output stage. At these operating parameters, we find the amplifier-to-amplifier charge transfer efficiency (ACTE) to be >0.9995 at low counts for all amplifiers but one for which the ACTE is 0.997. This charge transfer efficiency falls above 50,000 electrons for the read-noise optimized voltage configuration we chose for the serial clocks and gates. The amplifier linearity across a broad dynamic range from ∼300 to 35,000 e$^{−}$ was also measured to be ±2.5%. We describe key operating parameters to optimize on these characteristics and describe the specific applications for which the MAS CCD may be a suitable detector candidate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the DUNE photodetectors and study of the event burst phenomenon

The Deep Underground Neutrino Experiment (DUNE) is an upcoming neutrino physics experiment that will answer some of the most compelling questions in particle physics and cosmology. The DUNE far detectors employ silicon photomultipliers (SiPMs) to detect light produced by charged particles interacting in a large liquid argon time projection chamber (LArTPC). The SiPMs are photosensors consisting of an array of single-photon avalanche diodes (SPAD) operating in Geiger mode. Their high sensitivity and dynamic range, as well as the possibility to fill large surfaces with high-granularity sensors, makes them an ideal choice for DUNE. An international consortium of research groups is currently engaged in a systematic comparison of the performances of the SiPM models that have been custom developed for DUNE by two manufacturers. Such detailed studies, which include gain measurements and a structure study of the dark count rate at 77 K, are meant to determine the best choice of the photodetection system for DUNE, as well as characterize the response of the chosen detectors for the DUNE simulation. Moreover, an investigation of a newly observed phenomenon, in which quick bursts of tens of events at close range are collected in individual SiPMs, is being carried out, which potentially impacts the design of future models and their implementation in particle physics experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of an architecture for front-end pixel binning in an integrating pixel array detector

Optimization of an area detector involves compromises between various parameters like frame rate, read noise, dynamic range and pixel size. We have implemented and tested a novel front-end binning design in a photon-integrating hybrid pixel array detector using the MM-PAD- 2.0 pixel architecture. In this architecture, the pixels can be optionally binned in a 2 x 2 pixel configuration using a network of switches to selectively direct the output of 4 sensor pixels to a single amplifier input. Doing this allows a trade-off between frame rate and spatial resolution. Tests show that the binned pixels perform well, but with some degradation on performance as compared to an un-binned pixel. The increased parasitic input capacitance does reduce the signal collected per x-ray as well as increases the noise of the pixel. Here, the increase in noise is, however, less than the factor of 2 increase one would observe for binning in post-processing. Spatial scans across the binned pixels show that no measured signal intensity is lost at the inner binning unit boundaries. In the high flux regime, at a 2 x 2 pixel wide beam spot (FWHM) size, binned mode responds linearly up to a photon flux of 10 7 x-rays/s, and performs comparably with un-binned mode up to a photon flux of 10 8 x-rays/s. While this study demonstrates a proof of concept for front-end binning in integrating detectors, we also identify changes to this early-stage prototype which can further improve the performance of binning pixel structures.

47 OTHER INSTRUMENTATION↗

Design, upgrade and characterization of the silicon photomultiplier front-end for the AMIGA detector at the Pierre Auger Observatory

AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory to complement the study of ultra-high-energy cosmic rays (UHECR) by measuring the muon content of extensive air showers (EAS). It consists of an array of 61 water Cherenkov detectors on a denser spacing in combination with underground scintillation detectors used for muon density measurement. Each detector is composed of three scintillation modules, with 10 m 2 detection area per module, buried at 2.3 m depth, resulting in a total detection area of 30 m 2 . Silicon photomultiplier sensors (SiPM) measure the amount of scintillation light generated by charged particles traversing the modules. In this paper, the design of the front-end electronics to process the signals of those SiPMs and test results from the laboratory and from the Pierre Auger Observatory are described. Compared to our previous prototype, the new electronics shows a higher performance, higher efficiency and lower power consumption, and it has a new acquisition system with increased dynamic range that allows measurements closer to the shower core. The new acquisition system is based on the measurement of the total charge signal that the muonic component of the cosmic ray shower generates in the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of the underground muon detector of the Pierre Auger Observatory

To obtain direct measurements of the muon content of extensive air showers with energy above 10 16.5 eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10 m 2 -modules, each segmented into 64 scintillators coupled to silicon photomultipliers (SiPMs). Direct access to the shower muon content allows for the study of both of the composition of primary cosmic rays and of high-energy hadronic interactions in the forward direction. As the muon density can vary between tens of muons per m 2 close to the intersection of the shower axis with the ground to much less than one per m 2 when far away, the necessary broad dynamic range is achieved by the simultaneous implementation of two acquisition modes in the read-out electronics: the binary mode, tuned to count single muons, and the ADC mode, suited to measure a high number of them. In this work, we present the end-to-end calibration of the muon detector modules: first, the SiPMs are calibrated by means of the binary channel, and then, the ADC channel is calibrated using atmospheric muons, detected in parallel to the shower data acquisition. The laboratory and field measurements performed to develop the implementation of the full calibration chain of both binary and ADC channels are presented and discussed. The calibration procedure is reliable to work with the high amount of channels in the UMD, which will be operated continuously, in changing environmental conditions, for several years.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A sub-picosecond digitally-controlled phase delay

The use of precision timing measurements will be a major tool at the HL-LHC, where it will be used to suppress pile-up and to search for long-lived particles. To control a reference clock with sub-picosecond accuracy, we have fabricated in the TSMC 65 nm process a digitally controlled phase shifter. It is composed of a chain of 66 cells, each with a digitally controlled planar wave guide with either a short or long delay. With this a reference clock’s phase can be controlled to a precision of 200 fs with dynamic range of 12 ps.

Instruments & Instrumentation↗