Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diode lasers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Spectral features and thermal resistance of 976-nm cw laser diodes with a power up to 15 W

The spectral characteristics of cw laser diodes with a maximum reliable power of 15 W mounted on F-mount heat sinks are studied. It is found that the spectrum envelopes have features at emission powers exceeding 5 – 7 W. A method for determining the maximum of a spectrum envelope under the conditions of its broadening and appearance of features is discussed. The thermal resistance of diodes is determined experimentally at pump currents from threshold to maximum (14 A) and is found to be 2.25 K W{sup -1} at a current of 10 A and 1.5 K W{sup -1} at a current of 4 A. The results obtained are compared with the literature data. The adequacy of using the thermal resistance parameter for comparing and estimating thermal characteristics of laser diodes is considered. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NASA direct detection laser diode driver

TRW has developed a prototype driver circuit for GaAs laser diodes as part of the NASA/Goddard Space Flight Center's Direct Detection Laser Transceiver (DDLT) program. The circuit is designed to drive the laser diode over a range of user-selectable data rates from 1.7 to 220 Mbps, Manchester-encoded, while ensuring compatibility with 8-bit and quaternary pulse position modulation (QPPM) formats for simulating deep space communications. The resulting hybrid circuit has demonstrated 10 to 90 percent rise and fall times of less than 300 ps at peak currents exceeding 100 mA.

Seery, B. D.↗

Reliability improvements in tunable Pb1-xSnxSe diode lasers

Recent developments in the technology of Pb-salt diode lasers which have led to significant improvements in reliability and lifetime, and to improved operation at very long wavelengths are described. A combination of packaging and contacting-metallurgy improvements has led to diode lasers that are stable both in terms of temperature cycling and shelf-storage time. Lasers cycled over 500 times between 77 K and 300 K have exhibited no measurable changes in either electrical contact resistance or threshold current. Utilizing metallurgical contacting process, both lasers and experimental n-type and p-type bulk materials are shown to have electrical contact resistance values that are stable for shelf storage periods well in excess of one year. Problems and experiments which have led to devices with improved performance stability are discussed. Stable device configurations achieved for material compositions yielding lasers which operate continuously at wavelengths as long as 30.3 micrometers are described.

Linden, K. J.↗

CTE-tuned pyrolytic graphite (PG) substrate to minimize joining stress between laser diode and the substrate

A pyrolytic graphite (PG) substrate and laser diode package includes a substrate body having a PG crystalline structure with a basal plane oriented at a pre-determined orientation angle as measured from a longitudinal axis of a heat generating material, such as a laser diode, mounted on a surface of the PG substrate, so that a coefficient of thermal expansion (CTE) of the PG substrate is substantially matched with a CTE of the material.

Patra, Susant K.↗

CTE-tuned pyrolytic graphite (PG) substrate to minimize joining stress between laser diode and the substrate

A pyrolytic graphite (PG) substrate and laser diode package includes a substrate body having a PG crystalline structure with a basal plane oriented at a pre-determined orientation angle as measured from a longitudinal axis of a heat generating material, such as a laser diode, mounted on a surface of the PG substrate, so that a coefficient of thermal expansion (CTE) of the PG substrate is substantially matched with a CTE of the material.

Patra, Susant↗

Generation of 369.4 nm Radiation by Efficient Doubling of a Diode Laser

The trapped ytterbium ion frequency standard under development at JPL is designed to supply ultra-stable reference signals to be used in spacecraft tests of general relativity and other science experiments. Only diode lasers meet the requirements of low power comsumption and small size for use aboard spacecraft, but diode lasers are not currently available at 369.4 nm wavelength. It is therefore necessary to employ frequency doubling methods to reach this frequency with diode lasers. Here we present the characteristics of the resonant cavity doubling system we have designed and preliminary UV conversion results.

ultra-stable↗

Characterization of High-power Quasi-cw Laser Diode Arrays

NASA s requirements for high reliability, high performance satellite laser instruments have driven the investigation of many critical components; specifically, 808 nm laser diode array (LDA) pump devices. Performance and comprehensive characterization data of Quasi-CW, High-power, laser diode arrays is presented.

Stephen, Mark A.↗

MicroPulse DIAL (MPD) – a diode-laser-based lidar architecture for quantitative atmospheric profiling

Abstract. Continuous water vapor and temperature profiles are critically needed for improved understanding of the lower atmosphere and potential advances in weather forecasting skill. Ground-based, national-scale profiling networks are part of a suite of instruments to provide such observations; however, the technological method must be cost-effective and quantitative. We have been developing an active remote sensing technology based on a diode-laser-based lidar technology to address this observational need. Narrowband, high-spectral-fidelity diode lasers enable accurate and calibration-free measurements requiring a minimal set of assumptions based on direct absorption (Beer–Lambert law) and a ratio of two signals. These well-proven quantitative methods are known as differential absorption lidar (DIAL) and high-spectral-resolution lidar (HSRL). This diode-laser-based architecture, characterized by less powerful laser transmitters than those historically used for atmospheric studies, can be made eye-safe and robust. Nevertheless, it also requires solar background suppression techniques such as narrow-field-of-view receivers with an ultra-narrow bandpass to observe individual photons backscattered from the atmosphere. We discuss this diode-laser-based lidar architecture's latest generation and analyze how it addresses a national-scale profiling network's need to provide continuous thermodynamic observations. The work presented focuses on general architecture changes that pertain to both the water vapor and the temperature profiling capabilities of the MicroPulse DIAL (MPD). However, the specific subcomponent testing and instrument validation presented are for the water vapor measurements only. A fiber-coupled seed laser transmitter optimization is performed and shown to meet all of the requirements for the DIAL technique. Further improvements – such as a fiber-coupled near-range receiver, the ability to perform quality control via automatic receiver scanning, advanced multi-channel scalar capabilities, and advanced processing techniques – are discussed. These new developments increase narrowband DIAL technology readiness and are shown to allow higher-quality water vapor measurements closer to the surface via preliminary intercomparisons within the MPD network itself and with radiosondes.

Spuler, Scott M.↗

High-power AlGaAs channeled substrate planar diode lasers for spaceborne communications

A high power channeled substrate planar AlGaAs diode laser with an emission wavelength of 8600 to 8800 A was developed. The optoelectronic behavior (power current, single spatial and spectral behavior, far field characteristics, modulation, and astigmatism properties) and results of computer modeling studies on the performance of the laser are discussed. Lifetest data on these devices at high output power levels is also included. In addition, a new type of channeled substrate planar laser utilizing a Bragg grating to stabilize the longitudinal mode was demonstrated. The fabrication procedures and optoelectronic properties of this new diode laser are described.

Connolly, J. C.↗

Stirling-Cycle Cooling For Tunable Diode Laser

Miniature Stirling-cycle cooler effective in continously cooling PbSnTe tunable diode laser to stable operating temperature near 80 K. Simplifies laboratory diode-laser spectroscopy and instruments for use aboard aircraft and balloons.

Durso, Santo S.↗

"Application of Tunable Diode Laser Spectrometry to Isotopic Studies for Exobiology"

Computer-controlled electrically-activated valves for rapid gas-handling have been incorporated into the Stable Isotope Laser Spectrometer (SILS) which now permits rapid filling and evacuating of the sample and reference gas cells, Experimental protocols have been developed to take advantage of the fast gas handling capabilities of the instrument and to achieve increased accuracy which results from reduced instrumental drift during rapid isotopic ratio measurements. Using these protocols' accuracies of 0.5 del (0.05%) have been achieved in measurements of 13C/12C in carbon dioxide. Using the small stable isotope laser spectrometer developed in a related PIDDP project of the Co-I, protocols for acquisition of rapid sequential calibration spectra were developed which resulted in 0.5 del accuracy also being achieved in this less complex instrument. An initial version of software for automatic characterization of tunable diode lasers has been developed and diodes have been characterized in order to establish their spectral output properties. A new state-of-the-art high operating temperature (200 K) mid infrared diode laser was purchased (through NASA procurement) and characterized. A thermo-electrically cooled mid infrared tunable diode laser system for use with high temperature operation lasers was developed. In addition to isotopic ratio measurements of carbon and oxygen, measurements of a third biologically important element (15N/14N in N2O gas) have been achieved to a preliminary accuracy of about 0.2%. Transfer of the basic SILS technology to the commercial sector is proceeding under an unfunded Space Act Agreement between NASA and SpiraMed, a medical diagnostic instrument company. Two patents have been issued. Foreign patents based on these two US patents have been applied for and are expected to be issued. A preliminary design was developed for a thermo-electrically cooled SILS instruments for application to planetary space flight exploration missions.

Sauke, Todd B.↗

New Framework to Prevent Catastrophic Damage to Laser Diodes

We created a new framework and conducted first set of validation experiments to characterized diode damage by back-irradiance from reflections for a range of device configurations and operating conditions. The work conducted provides evidence that previously observed back-irradiance induced catastrophic damage in diodes is thermally driven and allows estimation of diode lifetime through the new framework if specific back-irradiance and diode parameters are known. The enhanced ability to predict diode damage from back-irradiance will allow improved diode-pumped laser designs for a variety of defense, science, and industrial applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In situ stratospheric measurements of HNO3 and HCl near 30 km using the balloon-borne laser in situ sensor tunable diode laser spectrometer

In situ stratospheric measurements of the concentrations of the reservoir species HNO3 and HCl made during two flights of the high-resolution (0.0005/cm) balloon-borne laser in situ sensor instrument from Palestine, Texas, are reported. A measured HNO3 volume mixing ratio of 4.3 parts per billion by volume (ppbv) at 31 km altitude is about 1 ppbv larger than previously reported measurements at 32 deg N. An HCl mixing ratio of 1.6 ppbv at 29 km is in agreement with values obtained from earlier remote sensing techniques within the experimental uncertainties. Upper limits at 31 km of 0.4 ppbv for H2O2 and 0.2 ppbv for HOCl are also derived from analyses of spectra recorded near 1252/cm.

May, R. D.↗

Ohmic contacts for laser diodes

Requirements for ohmic contacts to laser diodes are discussed, and properties of Schottky barrier tunneling contacts are reviewed. A procedure is described for measuring contact resistance on fabricated laser material without the need for specially constructed samples and contact configurations. Measurements of contact resistance and estimates of specific contact resistance are given for Ti/Pt/Au contacts to surfaces with three different doping levels. It was found that below a p-type carrier concentration of 1 x 10 to the 19th per cu cm the contact resistance is likely to be too high for good device performance. At higher doping levels, a specific contact resistance as low as 2 x 10 to the -6th ohm sq cm was obtained. Oxide stripe lasers provided with the type of contact discussed in this paper have been operated without failures for periods up to 7 years at a current density at the contact of 6-8 kA/sq cm. It appears therefore that these contacts satisfy the need for low resistance and durability and that, at the same time, they do not cause any obvious material degradation.

Ladany, I.↗

Thermometry of an open spatially inhomogeneous flame by diode laser absorption spectroscopy

Features of a single-beam variant of diode laser absorption spectroscopy (DLAS) used for temperature measurements in a spatially inhomogeneous hot zone are studied. A flame temperature of a commercial burner is measured by using water molecule absorption lines. The flame is probed by a diode laser radiation at various heights and in various directions. The correctness of DLAS measurement results is verified by comparing DLAS data with temperatures measured by the method of coherent anti-Stokes scattering (CARS). It is shown that in homogeneous flame domains the temperatures obtained by both the methods coincide. Temperature inhomogeneity along the probe beam direction is a principal problem of DLAS, in which case the method yields information about some effective temperature along the light trace. The difference in data obtained by DLAS and CARS is estimated. In probing traces with temperature gradients the difference reaches 700 K. Possibilities of accounting for temperature inhomogeneities along the trace in DLAS measurements are discussed. A method of differential spectra is suggested, which in certain conditions can provide substantially better coincidence of results for the two methods. (laser spectroscopy)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The thickness design of unintentionally doped GaN interlayer matched with background doping level for InGaN-based laser diodes

In order to reduce the internal optical loss of InGaN laser diodes, an unintentionally doped GaN (u-GaN) interlayer is inserted between InGaN/GaN multiple quantum well active region and Al{sub 0.2}Ga{sub 0.8}N electron blocking layer. The thickness design of u-GaN interlayer matching up with background doping level for improving laser performance is studied. It is found that a suitably chosen u-GaN interlayer can well modulate the optical absorption loss and optical confinement factor. However, if the value of background doping concentration of u-GaN interlayer is too large, the output light power may decrease. The analysis of energy band diagram of a LD structure with 100 nm u-GaN interlayer shows that the width of n-side depletion region decreases when the background concentration increases, and may become even too small to cover whole MQW, resulting in a serious decrease of the output light power. It means that a suitable interlayer thickness design matching with the background doping level of u-GaN interlayer is significant for InGaN-based laser diodes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tunable diode laser measurements of HO2NO2 absorption coefficients near 12.5 microns

A tunable diode laser spectrometer has been used to measure absorption coefficients of peroxynitric acid (HO2NO2) near the 803/cm Q branch. HO2NO2 concentrations in a low-pressure flowing gas mixture were determined from chemical titration procedures and UV absorption spectroscopy. The diode laser measured absorption coefficients, at a spectral resolution of better than 0.001/cm, are about 10 percent larger than previous Fourier transform infrared measurements made at a spectral resolution of 0.06/cm.

May, R. D.↗