Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diffraction pattern”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Fluctuation cepstral scanning transmission electron microscopy of mixed-phase amorphous materials

Four-dimensional scanning transmission electron microscopy (4D-STEM) is a versatile analytical tool for characterizing materials structural properties. However, extending such analysis to disordered materials is challenging, especially in technologically important samples with mixed ordered and disordered phases. Here, in this work, we present a new 4D-STEM method, called fluctuation cepstral STEM (FC-STEM), based on the fluctuation analysis of cepstral transform of diffraction patterns. The peaks in the associated transformation relate to inter-atomic distances in a thin sample. By varying the real-space range over which fluctuations are calculated, distinct ordered and disordered phases can be mapped in a diffractive image reconstruction. We demonstrate the principles of FC-STEM by characterizing a silicon anode, harvested from a cycled lithium-ion battery. A mixture of amorphous and nanocrystalline silicon, graphitic carbon, and electrolyte by-products is identified and mapped. Comparisons with conventional electron imaging and energy-dispersive X-ray spectroscopy show that FC-STEM is highly effective for the structure determination of mixed-phase amorphous materials.

36 MATERIALS SCIENCE↗

Denoising atomic resolution 4D scanning transmission electron microscopy data with tensor singular value decomposition

Tensor singular value decomposition (SVD) is a method to find a low-dimensional representation of data with meaningful structure in three or more dimensions. Here, tensor SVD has been applied to denoise atomic-resolution 4D scanning transmission electron microscopy (4D STEM) data. On data simulated from a SrTiO 3 [100] perfect crystal and a Si [110] edge dislocation, tensor SVD achieved an average peak signal-to-noise ratio (PSNR) of ~40 dB, which matches or exceeds the performance of other denoising methods, with processing times at least 100 times shorter. On experimental data from SrTiO 3 [100] and LiZnSb [11 2 ¯ 0]/GaSb [110] samples, tensor SVD denoises multiple GB 4D STEM data sets in ten minutes on a typical personal computer. Denoising with tensor SVD improves both convergent beam electron diffraction patterns and virtual-aperture annular dark field images.

36 MATERIALS SCIENCE↗

Three-dimensional coherent Bragg imaging of spontaneously rotating nanoparticles

Series of coherent diffraction patterns were collected from crystalline gold nanoparticles as these rotated under the influence of a focused X-ray beam. The resulting movies show the (111) Bragg peaks crossing the Ewald sphere, and the frames can be assembled into three-dimensional diffraction volumes and phased.

60 nm truncated-octrahedral gold nanoparticles↗

Neutron diffraction probing hydrogen in monoclinic H 2 VOPO 4

Light hydrogen atoms are resolvable with neutrons; however, the massive incoherent background inhibits the diffraction quality. To improve the signal, isotope treatment by deuteration becomes a prerequisite for a successful crystallographic understanding of hydrogen-containing materials by neutron diffraction. Thanks to the low-background and high-resolution time-of-flight neutron diffractometer, this work demonstrates a direct and successful measurement of high-quality neutron diffraction patterns of H 2 VOPO 4 powders, a precursor of a high-capacity alkali-ion battery cathode. The Rietveld refinement identifies the hydrogen coordinates, occupancy, and thermal parameters in the H 2 VOPO 4 lattice. Finally, the result highlights the unique capability of neutron diffraction for the structure characterization of hydrogen-containing materials, potentially without requiring costly and possibly artifact-inducing deuteration for neutron diffraction.

36 MATERIALS SCIENCE↗

Multiple origins of extra electron diffractions in fcc metals

Diffuse intensities in the electron diffraction patterns of concentrated face-centered cubic solid solutions have been widely attributed to chemical short-range order, although this connection has been recently questioned. This article explores the many nonordering origins of commonly reported features using a combination of experimental electron microscopy and multislice diffraction simulations, which suggest that diffuse intensities largely represent thermal and static displacement scattering. A number of observations may reflect additional contributions from planar defects, surface terminations incommensurate with bulk periodicity, or weaker dynamical effects.

36 MATERIALS SCIENCE↗

Advanced High Brilliance X-Ray Source

The possibility to dramatically increase the efficiency of laboratory based protein structure measurements through the use of polycapillary X-ray optics was investigated. This project initiated April 1, 1993 and concluded December 31, 1996 (including a no cost extension from June 31, 1996). This is a final report of the project. The basis for the project is the ability to collect X-rays from divergent electron bombardment laboratory X-ray sources and redirect them into quasiparallel or convergent (focused) beams. For example, a 0.1 radian (approx. 6 deg) portion of a divergent beam collected by a polycapillary collimator and transformed into a quasiparallel beam of 3 millradian (0.2 deg) could give a gain of 6(exp 2)/0.2(exp 2) x T for the intensity of a diffracted beam from a crystal with a 0.2 deg diffraction width. T is the transmission efficiency of the polycapillary diffraction optic, and for T=0.5, the gain would be 36/0.04 x O.5=45. In practice, the effective collection angle will depend on the source spot size, the input focal length of the optic (usually limited by the source spot-to-window distance on the x-ray tube) and the size of the crystal relative to the output diameter of the optic. The transmission efficiency, T, depends on the characteristics (fractional open area, surface roughness, shape and channel diameter) of the polycapillary optic and is typically in the range 0.2-0.4. These effects could substantially reduce the expected efficiency gain. During the course of this study, the possibility to use a weakly focused beam (0.5 deg convergence) was suggested which could give an additional 10-20 X efficiency gain for small samples . Weakly focused beams from double focusing mirrors are frequently used for macromolecular crystallography studies. Furthermore the crystals are typically oscillated by as much as 2 deg during each X-ray exposure in order to increase the reciprocal space (number of crystal planes) sampled and use of a slightly convergent beam could, in principle, provide a similar sampling benefit without oscillation. Although more problematic, because of complications in analyzing the diffraction patterns, it was also suggested that even more extreme beam convergence might be used to give another order of magnitude intensity gain and even smaller focused spot size which could make it possible to study smaller protein crystals than can be studied using standard laboratory based X-ray diffraction systems. This project represents the first systematic investigation of these possibilities. As initially proposed, the contract included requirements for design, purchase, evaluation and delivery of three polycapillary lenses to the Laboratory for Structural Biology at MSFC and demonstration of such optics at MSFC for selected protein crystal diffraction applications.

Gibson, Walter M.↗

Derived crystal structure of martensitic materials by solid–solid phase transformation

A mathematical description of crystal structure is proposed consisting of two parts: the underlying translational periodicity and the distinct atomic positions up to the symmetry operations in the unit cell, consistent with the International Tables for Crystallography. By the Cauchy–Born hypothesis, such a description can be integrated with the theory of continuum mechanics to calculate a derived crystal structure produced by solid–solid phase transformation. In addition, the expressions for the orientation relationship between the parent lattice and the derived lattice are generalized. Additionally, the derived structure rationalizes the lattice parameters and the general equivalent atomic positions that assist the indexing process of X-ray diffraction analysis for low-symmetry martensitic materials undergoing phase transformation. The analysis is demonstrated in a CuAlMn shape memory alloy. From its austenite phase (L2 1 face-centered cubic structure), it is identified that the derived martensitic structure has orthorhombic symmetry Pmmn with the derived lattice parameters a d = 4.36491, b d = 5.40865 and c d = 4.2402 Å, by which the complicated X-ray Laue diffraction pattern can be well indexed, and the orientation relationship can be verified.

36 MATERIALS SCIENCE↗

3D Reconstruction of a High-Energy Diffraction Microscopy Sample Using Multi-modal Serial Sectioning with High-Precision EBSD and Surface Profilometry

High-energy diffraction microscopy (HEDM) combined with in situ mechanical testing is a powerful nondestructive technique for tracking the evolving microstructure within polycrystalline materials during deformation. This technique relies on a sophisticated analysis of X-ray diffraction patterns to produce a three-dimensional reconstruction of grains and other microstructural features within the interrogated volume. However, it is known that HEDM can fail to identify certain microstructural features, particularly smaller grains or twinned regions. Characterization of the identical sample volume using high-resolution surface-specific techniques, particularly electron backscatter diffraction (EBSD), can not only provide additional microstructure information about the interrogated volume but also highlight opportunities for improvement of the HEDM reconstruction algorithms. In this study, a sample fabricated from undeformed “low solvus, high refractory” nickel-based superalloy was scanned using HEDM. The volume interrogated by HEDM was then carefully characterized using a combination of surface-specific techniques, including epi-illumination optical microscopy, zero-tilt secondary and backscattered electron imaging, scanning white light interferometry, and high-precision EBSD. Custom data fusion protocols were developed to integrate and align the microstructure maps captured by these surface-specific techniques and HEDM. The raw and processed data from HEDM and serial sectioning have been made available via the Materials Data Facility (MDF) at https://doi.org/10.18126/4y0p-v604 for further investigation.

36 MATERIALS SCIENCE↗

Carbon in the Allende meteorite - Evidence for poorly graphitized carbon rather than carbyne

A carbon-rich acid residue from the Allende carbonaceous chondrite was examined by high-resolution transmission electron microscopy (HRTEM) and also by analytical electron microscopy. A TEM mount of this residue that has previously been reported to contain carbyne forms of carbon was shown to contain sheet silicate contaminants. These sheet silicate grains give electron diffraction patterns similar to those reported for carbynes, thus raising questions about the previous report of carbynes in this residue. Furthermore, two crystals from a glacier microspherule, which had previously been identified as carbyne VIII, were shown by microanalysis to be talc. In view of these observations it is suggested that identifications of carbyne by electron diffraction should be supported by microanalyses of the individual grains. HRTEM investigations of the Allende carbon indicate that it is a poorly crystalline graphite, structurally similar to 'glassy' carbon

Smith, P. P. K.↗

Structural modulation and spin glassiness upon oxidation in oxygen storage material LnFeMnO 4+x for Ln = Y, Lu, and Yb

The mixed valence multiferroic LnFe 2+ Fe 3+ O 4 (where Ln = Y, Lu, and Yb) can reversibly uptake oxygen into its lattice, which is evidenced by a crystallographic phase transition along with the appearance of structural modulations. In this study, we show that the Mn-substituted version of this multiferroic can also be readily oxidized to LnFe 3+ Mn 3+ O 4.5 revealing similar oxygen storage behavior. Through neutron, electron, and synchrotron x-ray diffraction studies, we observe a structural modulation that we attribute to a displacement wave in the fully oxidized compound. This wave exhibits commensurability with a wavevector q = (-2/7, 1/7, 0). Bond valence summation analysis of plausible interstitial oxygen positions suggests that oxygen insertion likely occurs at the middle of the Fe/Mn–O bipyramid layers. The structural modulation of LnFeMnO 4.5 is two-dimensional, propagates along the ab-plane, and is highly symmetric as 12 identical modulation vectors are observed in the diffraction patterns. The nature of the lanthanide, Ln 3+ , does not seem to influence such modulations since we observe identical satellite reflections for all three samples of Ln = Y, Lu, and Yb. Both LnFeMnO 4 and LnFeMnO 4.5 display spin glassy behavior with 2D short-range magnetic ordering being observed in LnFeMnO 4 . Analysis of the neutron diffraction data reveals a correlation length of ~10 nm. Upon oxidation to LnFeMnO 4.5 , the short-range magnetic order is significantly suppressed.

36 MATERIALS SCIENCE↗

Neutron sub-micrometre tomography from scattering data

Neutrons are valuable probes for various material samples across many areas of research. Neutron imaging typically has a spatial resolution of larger than 20 µm, whereas neutron scattering is sensitive to smaller features but does not provide a real-space image of the sample. A computed-tomography technique is demonstrated that uses neutron-scattering data to generate an image of a periodic sample with a spatial resolution of ∼300 nm. The achieved resolution is over an order of magnitude smaller than the resolution of other forms of neutron tomography. This method consists of measuring neutron diffraction using a double-crystal diffractometer as a function of sample rotation and then using a phase-retrieval algorithm followed by tomographic reconstruction to generate a map of the sample's scattering-length density. Topological features found in the reconstructions are confirmed with scanning electron micrographs. This technique should be applicable to any sample that generates clear neutron-diffraction patterns, including nanofabricated samples, biological membranes and magnetic materials, such as skyrmion lattices.

nanoscience↗

Toward In Situ Synchrotron Mapping of Crystal Selection Processes during Crystal Growth

In this work, we present an automated and rapid method for non-destructive mapping of crystal grains in a rod-shaped sample. The approach was designed for application to in situ float-zone crystal growth experiments at an x-ray synchrotron source, but could be useful in other applications. The methods have been tested on a TiO 2 boule grown in an optical float zone furnace. The approach applies a statistical filter to polycrystalline diffraction patterns on 2D detectors to rapidly determine the degree of powder-quality 1of the signal. When larger crystals emerge in the growth, their position, size and shape can be tracked using an automated blob-tracking algorithm that follows individual Bragg peaks as a function of position in a grid-scan, even when multiple crystals are contributing spots to diffraction images. This method is found to be robust as the same crystal shape can be independently reconstructed using different sets of Bragg reflections. Image segmentation methods are then used to map out the polycrystalline grains. We also note that other information about crystal quality, such as mosaicity or strain state, may be inferred and mapped from the intensity variation of the Bragg peaks at different locations within the sample.

36 MATERIALS SCIENCE↗

In Situ Synchrotron X-ray Scattering Investigation of Cathodic ZIF-8 Deposition on Graphite Using 3D-Printed Cells

Electrochemical approaches provide unique means to fabricate thin films of metal organic frameworks (MOFs). However, the kinetics of electrochemical MOF deposition has not been quantitatively investigated so far. In this study, we report the first in situ measurements of electrochemical MOF growth using transmission synchrotron X-ray scattering. Electrochemical cells based on poly(lactic acid) with two windows were fabricated using fused-deposition modelling. Here, the resulting 3D-printed cells, the surface of which was coated with paraffin wax to prevent solvent percolation through the polymer material, were used to monitor the cathodic growth of zeolitic imidazolate framework-8 (ZIF-8) on graphite in a methanol solution containing ZnCl 2 and 2-methylimidazole (Hmim) at different cathodic potentials. The resulting time-resolved X-ray diffraction data showed a gradual increase in crystal size with negligible changes in crystal orientation during the cathodic ZIF-8 deposition. More importantly, the time-resolved data provided a means to quantitatively assess the kinetics of the cathodic ZIF-8 growth using the Gualtieri model, revealing that the cathodic potential and Hmim concentration affected crystal growth kinetics, but not nucleation kinetics. These ZIF-8 samples exhibited changes in X-ray diffraction pattern after being washed with methanol and dried in air, indicating that in situ measurements are essential to investigate mechanisms behind MOF electrodeposition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multilevel atomic structural model for interstratified opal materials

The structure of opal has long fascinated scientists. It occurs in a number of structural states, ranging from amorphous to exhibiting features of stacking disorder. Opal-CT, where C and T signify cristobalite- and tridymite-like interstratification, represents an important link in the length scales between amorphous and crystalline states. However, details about local atomic (dis)order and arrangements extending to long-range stacking faults in opal polymorphs remain incompletely understood. Here, a multilevel modeling approach is reported that considers stacking states in correlation with the abundance of C and T segments as a high-level structural parameter (i.e. not each atom). Optimization accounting for inter-tetrahedral bond lengths and angles and the regularity of the silicate tetrahedra is included as lower levels of structural parameters. Together, a set of parameters with both coarse-grained and atomistic features for different levels of structural details is refined. Structural disorder at the ~10–100 Å distance scale is evaluated using experimental pair distribution function and diffraction datasets, comparing peak intensities, widths and asymmetry. Here this work presents a complete multilevel structural description of natural opal-CT and explains many of the unusual features observed in X-ray powder diffraction patterns. This modeling approach can be adopted generally for analyzing layered materials and their assembly into 3D structures.

36 MATERIALS SCIENCE↗

Automated thematic mapping and change detection of ERTS-A images

The author has identified the following significant results. For the exploitation of the ERTS-1 images, both multispectral and spatial pattern recognition techniques are important. A multispectral recognition software program was successfully tested. A technique for the generation of resource boundaries has been successfully combined with terrain recognition software resulting in a regionalized terrain classification system. Digital registration of multispectral images has been achieved. Also, photointerpretation results from one test site are reported and the development of spatial terrain signatures from optical diffraction patterns is described.

Gramenopoulos, N.↗

The Metastable Persistence of Vapor-Deposited Amorphous Ice at Anomalously High Temperatures

Studies of the gas release, vaporization behavior and infrared (IR) spectral properties of amorphous and crystalline water ice have direct application to cometary and planetary outgassing phenomena and contribute to an understanding of the physical properties of astrophysical ices. Several investigators report anomalous phenomena related to the warming of vapor-deposited astrophysical ice analogs. However gas release, ice volatilization and IR spectral features are secondary or tertiary manifestations of ice structure or morphology. These observations are useful in mimicking the bulk physical and chemical phenomena taking place in cometary and other extraterrestrial ices but do not directly reveal the structural changes which are their root cause. The phenomenological interpretation of spectral and gas release data is probably the cause of somewhat contradictory explanations invoked to account for differences in water ice behavior in similar temperature regimes. It is the microstructure, micromorphology and microchemical heterogeneity of astrophysical ices which must be characterized if the mechanisms underlying the observed phenomena are to be understood. We have been using a modified Transmission Electron Microscope to characterize the structure of vapor-deposited astrophysical ice analogs as a function of their deposition, temperature history and composition. For the present experiments, pure water vapor is deposited at high vacuum onto a 15 K amorphous carbon film inside an Hitachi H-500H TEM. The resulting ice film (approx. 0.05 micrometers thick) is warmed at the rate of 1 K per minute and diffraction patterns are collected at 1 K intervals. These patterns are converted into radial intensity distributions which are calibrated using patterns of crystalline gold deposited on a small part of the carbon substrate. The small intensity contributed by the amorphous substrate is removed by background subtraction. The proportions of amorphous and crystalline material in each pattern are determined by subtracting a percentage of crystalline component relative to amorphous and pure crystalline endmembers. Vapor-deposited water ice undergoes two amorphous to amorphous structural transformations in the temperature range 15-130 K with important astrophysical implications. The onset of cubic crystallization occurs at 142-160 K (at 1K per minute heating rates) during which the 220 and 311 diffraction maxima appear and 0.1 micrometer crystallites can be seen in bright field images. This transition is time dependent.

Blake, David F.↗

Direct structural retrieval from gas-phase ultrafast diffraction data using a genetic algorithm

Ultrafast scattering techniques such as ultrafast electron diffraction and ultrafast x-ray diffraction have been utilized to elucidate the structural dynamics, reaction intermediates, and final products in molecular reactions following photoexcitation. The time-dependent structures are typically not directly retrieved from the experimental data, but they rely on comparison with calculations. The genetic algorithm (GA), a global optimization strategy, can be used to retrieve the molecular structures directly from diffraction patterns without any theoretical input. However, the robustness of the GA with respect to real experimental conditions such as a limited momentum transfer range, noise, and artifacts has not been studied in detail. In this work, we characterize the performance of the GA with simulated data that mimic realistic experimental conditions. We have developed and implemented a variant of the GA specific to diffraction measurements which performs better in the presence of imperfect data compared to the standard implementation of the GA. We demonstrate this method with both synthetic data and experimental ultrafast electron diffraction data on the UV-induced photodissociation of trifluoroiodomethane (C⁢F 3⁡ I) molecules.

74 ATOMIC AND MOLECULAR PHYSICS↗