Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data centers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A Novel and Scalable Method for Microencapsulating Salt Hydrate Phase Change Materials in Core–Shell Fibers

Phase change materials (PCMs) are in high demand for applications such as thermal energy storage in buildings, electronics cooling, and thermal management of electric vehicle batteries and data centers. Among these materials, salt hydrate PCMs are particularly attractive due to their high thermal energy storage capacity and low cost. However, they suffer from two major issues: leakage in the melted phase and phase segregation during phase transitions. Microencapsulation is the primary process capable of addressing both of these challenges. However, there is no reliable or scalable method available for microencapsulating salt hydrate PCMs. As a result, the full potential of salt hydrates for building and data center applications has yet to be realized. In this work, we present an innovative method for the microencapsulation of salt hydrate PCMs using a co‐axial pushing technique. This process creates core–shell fibers, with the salt hydrate as the core and a polymer as the shell. Our approach demonstrates strong potential for scalable microencapsulation of salt hydrate PCMs. In conclusion, achieving scalability could enable their widespread use in applications such as data center cooling, battery thermal management, and building climate control.

Sharma, Jaswinder [Oak Ridge National Laboratory (↗

NREL Cooling Evaluation Capabilities

Panel presentation providing an overview of the Energy Systems Integration Facility (ESIF). Provided examples of thermal and power testing of computer components. Showcased the ESIF data center and testing capabilities for computer equipment at scale.

center↗

Reliability of Copper Inverse Opal Surfaces for Extreme-Heat-Flux Micro-Coolers in Low-Global-Warming-Potential Refrigerant R-1233zd Pool Boiling Experiments

This presentation provides a brief snapshot of the InterPACK paper InterPACK2023-113781. The paper explores copper inverse opal (CIO) surface reliability in pool boiling experiments in water and a new, low-global-warming-potential (GWP = 1) hydrofluoroolefin (HFO) refrigerant R-1233zd. The CIO-based structure is intended to develop enhanced two-phase heat transfer surfaces for extreme-heat-flux (approximately 1 kW/cm2) micro-coolers. In this study, a limited number of pool boiling experiments were performed using water and HFO-1233zd fluid, and the reliability of the CIO-based surfaces was evaluated. Critical heat flux (CHF) values in HFO-1233zd at 40 Degrees Celsius to 45 Degrees Celsius saturation temperatures and the corresponding saturation pressures were also measured. The CHF values with the refrigerant are significantly lower compared to those with water, but the refrigerant allows for a wider usable temperature range in the end application of the micro-coolers and is not limited to data centers with controlled ambient conditions. Reliability experiments with CIO surface samples - involving pool boiling with water on the CIO surfaces for approximately 48 hours and with HFO-1233zd for 144 hours - showed no structural degradation of the enhanced surface or any significant performance drop in heat transfer coefficients. The CIO surface samples in water were oxidized, most likely due to the presence of air in water and in the experimental vessel.

critical heat flux↗

A Framework for Streamlining Large Load Interconnection: An Assessment of Current Practices and Emerging Strategies for Fair and Efficient Load Interconnection Processes

This report focuses on current perceptions, challenges, and processes related to interconnection of LELs to the grid; while these loads include several types of entities, the primary focus of this work is on data centers, the largest current driver of this growth. It begins by summarizing relevant context related to load growth in the United States, including key stakeholder perceptions as data center deployment drive historic load growth nationwide. It then reviews the current landscape of large load interconnection processes and challenges and then proposes a framework of potential strategies intended to support a more consistent, streamlined, and fair approach to load interconnection. This framework is adapted from solutions proposed or adopted to address similar challenges faced in generator interconnection queues as well as notable reforms currently being proposed or enacted for large loads that could be more widely adopted.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Classical and quantum compression for edge computing: the ubiquitous data dimensionality reduction

Edge computing aims to address the challenges associated with communicating and transferring large amounts of data generated remotely to a data center in a timely and efficient manner. A central pillar of edge computing is local (i.e., at- or near-source) data processing capability so that data transfer to a data center for processing can be minimized. Data compression at the edge is therefore a natural component of edge workflows. Here we present a survey of data compression algorithms with a focus on edge computing. Not all compression algorithms can accommodate the data type heterogeneity, tight processing and communication time constraints, or energy efficiency requirement characteristics of edge computing. We discuss specific examples of compression algorithms that are being explored in the context of edge computing. We end our review with a brief survey of emerging quantum compression techniques that are of importance in quantum information processing, including the proposed concept of quantum edge computing.

97 MATHEMATICS AND COMPUTING↗

High-Efficiency Quantum Dot Lasers as Comb Sources for DWDM Applications

The trend of data center transceivers is to increase bandwidth while simultaneously decreasing their size, power consumption, and cost. While data center links have previously relied on vertical-cavity surface-emitting lasers (VCSELs) or in-plane lasers using coarse wavelength division multiplexing (WDM) to encode data, recently, dense WDM (DWDM) has moved to the forefront for next-generation links. Several approaches exist as light sources for DWDM links; DFB arrays, nonlinear microcombs, and semiconductor mode-locked lasers (MLLs). This paper focuses on quantum dot MLLs (QDMLLs), which currently offer the best efficiency, simplicity, and size. The efficiency of optical combs generated by QDMLLs is analyzed in depth in this study.

Dumont, Mario (ORCID:000000023956612X)↗

Propane Fueling Infrastructure Trends: A Decade in Review

This report provides information on propane fueling infrastructure and industry trends over the last 10 years. It is informed primarily by propane fueling station location data collected through the Alternative Fuels Data Center's Alternative Fueling Station Locator from 2011 through 2021. Industry stakeholders, including the Propane Education & Research Council (PERC) and other members of the Alternative Fuels Data Center Station Locator Propane Working Group, also provided data and additional context around trends seen in the data.

33 ADVANCED PROPULSION SYSTEMS↗

Ultra-low thermal resistance and pressure drop copper and copper-tungsten diamond-shaped pin fin cold plates for liquid cooling of electronics

Modern and future data centers face increasing cooling challenges due to increasing chip thermal design power and die size, along with the need to reduce energy consumption used for cooling. High performance cooling solutions that maintain a low chip junction temperature are needed to ensure electronics reliability. This work develops an ultra-low thermal resistance and low pressure drop 75 mm × 75 mm cold plate, intended for next-generation electronics cooling. The cold plate features an array of diamond-shaped pin fins and integrated copper tungsten heat spreader, selected for its low coefficient of thermal expansion which reduces thermomechanical deformation and allows for closer integration of the cold plate with silicon dies. Starting with 300 candidate designs, three-dimensional computational fluid dynamics simulations predict the thermal-hydraulic performance of cold plate subsections. The highest performing geometries are evaluated with high fidelity simulations. Four cold plates are manufactured for experiments: three with diamond-shaped pin fins and one with straights fins for comparison purposes. The cold plates are fabricated from copper-tungsten (CuW), copper (Cu), or aluminum-silicon-magnesium alloy (AlSi10Mg). The diamond-shaped pin fins achieve a roughly 15 % lower thermal resistance compared to the conventional straight fin microchannel. The highest performing design achieves a chip-to-coolant (including thermal interface material) thermal resistance of 9.0 K/kW in CuW and 6.9 K/kW in Cu under a 1 kW heat load with an inlet-to-outlet pressure drop of 9.0 kPa and water as the working fluid. This work demonstrates ultra-low thermal resistance and pressure drop cold plates for large die, high heat load applications, and shows that CuW is an attractive cold plate material for improved reliability in next generation data center cooling.

Coefficient of thermal expansion↗

The Installation of Direct Water-Cooling Systems to Reduce Cooling Energy Requirements for High-Performance Computing Centers

A large cluster of High-Performance Computing (HPC) equipment at the Lawrence Livermore National Laboratory in California was retrofitted with an Asetek cooling system. The Asetek system is a hybrid scheme with water-cooled cold plates on high-heat-producing components in the information technology (IT) equipment, and with the remainder of the heat being removed by conventional air-cooling systems. In order to determine energy savings of the Asetek system, data were gathered and analyzed two ways: using top-down statistical models, and bottom-up engineering models. The cluster, “Cabernet”, rejected its heat into a facilities cooling water loop which in turn rejected the heat into the same chilled water system serving the computer-room air handlers (CRAHs) that provided the air-based cooling for the room. Because the “before” and “after” cases both reject their heat into the chilled water system, the only savings is due to reduction in CRAH fan power. The top-down analysis showed a 4% overall energy savings for the data center (power usage effectiveness (PUE) —the ratio of total data center energy to IT energy— dropped from 1.60 to 1.53, lower is better); the bottom-up analysis showed a 3% overall energy savings (PUE from 1.70 to 1.66) and an 11% savings for the Cabernet system by itself (partial PUE of 1.51). Greater savings, on the order of 15-20%, would be possible if the chilled water system was not used for rejecting the heat from the Asetek system. About 37% of the heat from the Cab system was rejected to the cooling water, lower than at other installations.

Earni, Shankar↗

RouteE: A Vehicle Energy Consumption Prediction Engine

The emergence of connected and automated vehicles and smart cities technologies create the opportunity for new mobility modes and routing decision tools, among many others. To achieve maximum mobility and minimum energy consumption, it is critical to understand the energy cost of decisions and optimize accordingly. The Route Energy prediction model (RouteE) enables accurate estimation of energy consumption for a variety of vehicle types over trips or sub-trips where detailed drive cycle data are unavailable. Applications include vehicle route selection, energy accounting and optimization in transportation simulation, and corridor energy analyses, among others. The software is a Python package that includes a variety of pre-trained models from the National Renewable Energy Laboratory (NREL). However, RouteE also enables users to train custom models using their own data sets, making it a robust and valuable tool for both fast calculations and rigorous, data-rich research efforts. The pre-trained RouteE models are established using NREL’s Future Automotive Systems Technology Simulator paired with approximately 1 million miles of drive cycle data from the Transportation Secure Data Center, resulting in energy consumption behavior estimates over a representative sample of driving conditions for the United States. Validations have been performed using on-road fuel consumption data for conventional and electrified vehicle powertrains. Transferring the results of the on-road validation to a larger set of real-world origin-destination pairs, it is estimated that implementing the present methodology in a green-routing application would accurately select the route that consumes the least fuel 90% of the time. The novel machine learning techniques used in RouteE make it a flexible and robust tool for a variety of transportation applications.

33 ADVANCED PROPULSION SYSTEMS↗

TASTI-GRID: An Overview of West Virginia’s Grid Resilience Challenges

West Virginia’s legacy as a top power producer with a legacy of mining and natural gas is well-known across the country. A state with historic underinvestment, vulnerability to natural hazards, and a large rural population – much of West Virginia’s critical energy infrastructure is beyond its recommended lifecycle at 75+ years old. West Virginian’s are feeling the effects of neighboring Virginia’s data center growth, as its grid interconnectedness with neighboring states have impacted energy affordability as power supply has not kept up with demand. The state aims to attract data centers to improve economic development, however, the age of infrastructure, utility reliability, weather-induced major outages, and cost of proposed improvements compound West Virginia’s resilience challenges.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Designing Energy-Efficient Quantum Computers Through Prediction and Reduction of Cooling Requirements for Cryogenic Electronics

Quantum computing has been identified as a “wild card” by the International Energy Agency in predicting future global data center energy usage. This is primarily because both uncertainty in the extent to which quantum computing will be adopted, and uncertainty in the power consumption of individual quantum data centers. Unlike the classical counterparts, quantum computers need to be maintained at near absolute zero, requiring energy-intensive cryogenic cooling systems. Therefore, as quantum computers scale up from existing 50 qubit technology demonstrations to the 10,000 to 100,000 qubit systems that will be able to solve complex problems, the energy consumption of both the electronics and the required cooling systems will also increase. To predict this scaling, this work analyzes the energy requirements for both computation and cooling of quantum hardware. We show that the energy requirements for cooling of quantum computers is determined by several computing system parameters, including the number and type of physical qubits, the operating temperature, the packaging efficiency of the system, and the split between circuits operating at cryogenic temperatures and those operating at room temperature. The energy requirements can then be found based on thermal system parameters such as cooling efficiency and cryostat heat transfer. Analysis of these parameters shows that the energy required for cooling is significantly larger than that required for computation, a reversal from energy usage patterns seen in conventional computing. The results and discussions provide a road-map for creating energy efficient quantum computers through the selection of computer architectures and cryogenic system configurations that minimize cooling requirements.

energy efficiency↗

FNET/GridEye: A Tool for Situational Awareness of Large Power Interconnetion Grids

This paper gives an overview of a wide-area measurement system deployed at the distribution level: FNET/GridEye, which consists of hundreds of sensors, communication and a data center. The sensors are utilized to take frequency, voltage phase angle and magnitude measurements from the ordinary 110 or 220V outlets in offices or residential houses. These measurements are continuously transmitted to the data center via Internet. Many applications have been implemented to monitor large-scale interconnected power grids, and interpret grid operation status to improve system operators' situational awareness capability. Some representative online and offline applications are presented in this paper, as well as several recently developed new applications.

Zhu, Lin↗

TURBO: Terabits/s Using Reconfigurable Bandwidth Optics (Final Report)

Large scale, big science applications are generating petabytes of data that need to be shared among multiple locations. Moving a petabyte of data at 100 Gb/s takes 22 hours. Reducing this to single digit hours or below is clearly attractive and with future applications anticipating exabyte scale transfers, multi-terabit per second capacities are needed. This scale of capacity is available using optical systems. Core optical systems have aggregate per fiber capacities on the order of 10 Tb/s and more than 100 Tb/s system experiments have been realized in the lab. But large optical capacities are not just reserved for the core as similar system capacities are available in metro networks right up to the enterprise, campus, or data center. In general, the same technology is used today in the metro area as in the long-haul networks—reconfigurable optical add drop multiplexing (ROADM) node-based wavelength division multiplexing (WDM) systems. Data centers already support massive internal capacities on the scale of 100’s of Tb/s. As new photonic integrated technologies mature, for example through initiatives such as the Integrated Photonics Innovative Manufacturing Institute (IP-IMI), the cost of optical interfaces is expected to decrease, and higher capacity and higher performance interfaces will become more affordable. This set of circumstances creates the potential that Tb/s capacities will be available at the enterprise and campus level to support large scale science network applications.

42 ENGINEERING↗

Cooling Matters: Benchmarking Large Language Models and Vision-Language Models on Liquid-Cooled Versus Air-Cooled H100 GPU Systems

The unprecedented growth in artificial intelligence (AI) workloads, recently dominated by large language models (LLMs) and vision-language models (VLMs), has intensified power and cooling demands in data centers. This study benchmarks LLMs and VLMs on two HGX nodes, each with 8× NVIDIA H100 graphics processing units (GPUs), using liquid and air cooling. Leveraging GPU Burn, Weights & Biases, and IPMItool, we collect detailed thermal, power, and computation data. Results show that the liquid-cooled systems maintain GPU temperatures between 41-50$^\circ$C, while the air-cooled counterparts fluctuate between 54-72$^\circ$C under load. This thermal stability of liquid-cooled systems yields 17% higher performance (54 TFLOPs/ GPU vs. 46 TFLOPs/GPU), performance-per-watt, reduced energy overhead, and greater system efficiency than the air-cooled counterparts. These findings underscore the energy and sustainability benefits of liquid cooling, offering a compelling path forward for hyperscale data centers seeking to optimize AI infrastructure. https://github.com/iscaas/Cooling-Matters.

Latif, Imran↗

Integrating Energy-Efficient Computing with Computational Research to Accelerate Energy Technology

NREL's computational sciences center hosts the largest high performance computing (HPC) capabilities dedicated to energy research while functioning as a living laboratory for energy-efficient computing. NREL's HPC capabilities support the research needs of the Department of Energy's Office of Energy Efficiency and Renewable Energy (EERE). In ten years of operation, HPC use in EERE-sponsored research has grown by a factor of 30, including work in electricity generation, energy efficiency, transportation, and energy system modeling. This paper analyzes this research portfolio, providing examples of individual use cases. The paper documents NREL's history of operating one of the world's most energy-efficient data centers while examining pathways to reduce economic and environmental impact beyond reduction of Power Usage Efficiency (PUE). This paper concludes by examining the unique opportunities created for accelerating improvements in data center efficiency created by combining an HPC system dedicated to energy research and a research program in energy-efficient computing.

97 MATHEMATICS AND COMPUTING↗

Uncertain quantum computing futures and potential energy and physical resource impacts at scale

Considerable attention has recently focused on the vast energy and water demands of supercomputing, namely large-scale data centers that underpin artificial intelligence (AI), one of the great disruptors of contemporary society. Looking ahead some years from now, quantum computing is poised to disrupt established computing paradigms once again. Scientists and engineers are now working intensely to bring this century-old dream of physicists to fruition. Yet, as quantum computers begin to be integrated with classical supercomputing architectures, the implications for energy and physical resource use also need to be understood, especially how they compare to today’s AI data centers. These impacts have not yet been quantified by the research community – a notable gap in the literature, even if commercial-scale deployment of Quantum-Accelerated Computing Infrastructure (QuACI) is not expected for a few more years. This study is the first to conduct such an assessment. Using publicly available information from academic sources and private industry, we characterize multiple configurations of superconducting qubit-based, fault-tolerant quantum computers (FTQC) that could plausibly be deployed at scale in the 2030s and into the 2040s. By parameterizing these FTQC systems at a process level, we conduct a prospective scenario analysis to quantify their energy and physical resource needs. While these estimates are uncertain, given the current state of quantum technologies and their unknown future trajectories, important insights can already be drawn. One key finding is that while the electricity needs for a fleet of FTQCs are within the bounds of previous modeling studies that have explored high electricity demand futures, the needs for certain physical resources, namely water and helium-3, could pose bottlenecks to QuACI scale-up.

Computing↗

Optimal environmental and economic performance trade-offs for fifth generation district heating and cooling network topologies with waste heat recovery

Network topology greatly influences both the economic and environmental performance of fifth generation district heating and cooling (5GDHC) systems. In this study the optimal trade-offs between the environmental and economic performance of 5GDHC network topologies for a five-building district with waste heat recovery were explored. A life cycle assessment method was used to calculate the total life cycle CO 2 emissions (LCCO2) associated with the installation and operation of various network topologies. Twelve months of empirical data from a data center cooling system were analyzed to assess its suitability for integration into a 5GDHC system. The most suitable method for utilizing this waste heat was selected based on the ambient loop warm pipe setpoint, waste heat temperature, and district energy system configuration. A multi-objective optimization algorithm was used to select the 5GDHC network topology that provided the optimal trade-off between LCCO2 and life cycle cost (LCC). A trade-off parameter was employed to weigh the importance of each objective in the selection process. The results showed waste heat from the data center was suitable for integration into the 5GDHC system due to its availability and consistent temperature profile. When return temperatures of 25 °C or higher were available from the liquid-cooled system, direct pre-heating of the ambient loop warm pipe was found to be the most effective waste heat integration method. The selection of the network topology that provided the optimal trade-off between LCCO2 and LCC (optimal trade-off topology) was highly dependent on factors such as fuel prices, CO 2 prices, electricity CO 2 emissions factors, availability of waste heat, embodied CO 2 emissions associated with network installation and network infrastructure costs. Optimal trade-off topologies produced substantial LCCO2 reductions relative to corresponding LCC increases. LCCO2 reduction to LCC increase ratios from 5.78 to 117.79 were identified with CO 2 offset costs ranging from 4.77 to 60.08 ($/tCO 2 e).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗