Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data centers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

The AMPTE IRM Science Data Center

The creation of artificial ion clouds is a major aspect of the AMPTE program. The IRM Science Data center supports real-time decision for a release with real-time scientific data processing and display including model calculations of ion trajectories. Additionally, survey plots and summary data records are generated in near real time thus allowing to start the data analysis as early as possible. For detailed analyses, interactive programs were developed so that physical parameters of all IRM experiments can be combined to produce common spectra or line plots.

Bauer, O. H.↗

Data Center Energy Efficiency

Fact sheet describes how the Federal Energy Management Program helps federal agencies implement data center energy efficiency projects.

Kam, Kendall [US Department of Energy (USDOE) Fede↗

SPASE: The Connection Among Solar and Space Physics Data Centers

The Space Physics Archive Search and Extract (SPASE) project is an international collaboration among Heliophysics (solar and space physics) groups concerned with data acquisition and archiving. Within this community there are a variety of old and new data centers, resident archives, "virtual observatories", etc. acquiring, holding, and distributing data. A researcher interested in finding data of value for his or her study faces a complex data environment. The SPASE group has simplified the search for data through the development of the SPASE Data Model as a common method to describe data sets in the various archives. The data model is an XML-based schema and is now in operational use. There are both positives and negatives to this approach. The advantage is the common metadata language enabling wide-ranging searches across the archives, but it is difficult to inspire the data holders to spend the time necessary to describe their data using the Model. Software tools have helped, but the main motivational factor is wide-ranging use of the standard by the community. The use is expanding, but there are still other groups who could benefit from adopting SPASE. The SPASE Data Model is also being expanded in the sense of providing the means for more detailed description of data sets with the aim of enabling more automated ingestion and use of the data through detailed format descriptions. We will discuss the present state of SPASE usage and how we foresee development in the future. The evolution is based on a number of lessons learned - some unique to Heliophysics, but many common to the various data disciplines.

Thieman, James R.↗

Extreme Efficiency 240 Vac to Load Data Center Power Delivery Topologies and Control

The research explored innovative new circuit topologies and power converter architectures for data center power delivery, from the 240 V ac voltage at the input of a server rack, down to the less than 1 V dc power supply of the latest microprocessors. The research pursued three parallel tracks to increase the power conversion efficiency and to reduce the overall size of the servers: 1) An innovative new ac-dc power converter topology which enables improved efficiency through use of a novel direct step-down topology, well suited for the popular 48V dc power distribution. 2) A new series-stacked power delivery approach for servers comprising a large number of similar loads, such as hard drives in storage servers. The approach greatly reduces the power conversion losses, and achieves efficiency well over 99%. 3) A new family of hybrid switched-capacitor power converters that enable improved efficiency and reduced size through the use of dense ceramic capacitors and new circuit topologies that leverage GaN and low-voltage Si transistor technology. Together, the accomplished research achieved the goal of reducing the power conversion losses in datacenters, thereby reducing greenhouse gas emissions, operating costs, and overall electricity consumption.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of a Knowledge Graph for Dataset Discovery and Identification at a NASA Data Center

The NASA Goddard Earth Sciences Data and Information Services Center (GES DISC) archives and distributes hundreds of Earth Science data collections to the public. These collections are used in research, resulting in the publication of thousands of scientific papers each year. As new users come to GES DISC for data, it is important for them to understand how prior research used the data. To help researchers, a knowledge graph (KG) was designed and implemented to connect publication citations with dataset metadata. The relationships created in the graph have the potential to allow the Web applications that utilize this information to directly connect the publication to the GES DISC datasets and services. These relationships are demonstrated using a web application prototype. In addition, the graph can also make connections between publications, datasets, and measurements based on the mentions of datasets and their attributes in the publications. To demonstrate this capability, a web application was created that takes the excerpt from the publication and returns a most likely dataset and measurement pairing, ranking the results based on how often these datasets and measurements were used in prior publications.

Nathaniel Crosby↗

Shuttle Data Center File-Processing Tool in Java

A Java-language computer program has been written to facilitate mining of data in files in the Shuttle Data Center (SDC) archives. This program can be executed on a variety of workstations or via Web-browser programs. This program is partly similar to prior C-language programs used for the same purpose, while differing from those programs in that it exploits the platform-neutrality of Java in implementing several features that are important for analysis of large sets of time-series data. The program supports regular expression queries of SDC archive files, reads the files, interleaves the time-stamped samples according to a chosen output, then transforms the results into that format. A user can choose among a variety of output file formats that are useful for diverse purposes, including plotting, Markov modeling, multivariate density estimation, and wavelet multiresolution analysis, as well as for playback of data in support of simulation and testing.

Barry, Matthew R.↗

Project Phase 1 Report: Reducing Data Center Peak Cooling Demand and Energy Costs With Cold Underground Thermal Energy Storage (Cold UTES)

Cold Underground Thermal Energy Storage (Cold UTES) is an ultra-long duration grid energy storage technology. With Cold-UTES, low-cost grid power is converted to cold thermal energy and stored in the native subsurface rock at the point of use. Cold UTES is one approach within the general category of engineered geothermal systems. Cold UTES for peak-hour cooling of data centers (DCs) was studied for deployment in Maricopa County, Arizona and Loudoun County, Virgina using thermal storage capacities from 4 GWh-th to over 1,000 GWh-th (>1 Terawatt-hour). The two sites have different power and transmission systems, available grid energy resources, daily and seasonal load profiles, weather conditions, and grid regulatory requirements. The study results indicate high value for both locations and because of this, likely indicates value across most of the US and the world. The basis of the study was a 1,000 MW-e hourly electric use of DC computing and auxiliary loads, which was modeled as 1 GW-th of thermal load to a dry cooled heat rejection system - i.e. a cooling system that does not consume water. The electric power required for cooling the DC varies as the air temperature changes. In cold weather only the dry-coolers are used, with an electrical load for cooling load as low as 10 MW-e. In hot summer hours, chillers and dry- coolers are required, which raises the electrical load for cooling load to as much as 300 MW-e. The continuous and peak cooling electrical loads result in a grid interconnection requirement of no less than 1,300 MW-e. From both a grid and thermal design modeling perspective the 1.3 GW-e could either be a single facility or result from the total load at multiple sites.

15 GEOTHERMAL ENERGY↗

Enhancing Discoverability and Management of Atmospheric Data at Scale: Solutions from the ARM Data Center

The Atmospheric Radiation Measurement (ARM) is a multi-laboratory and multi-institutional U.S. Department of Energy (DOE) Office of Science National User Facility. The ARM Data Center (ADC), located at Oak Ridge National Laboratory, collects, archives, and shares vast atmospheric data crucial for climate research. The ADC manages over 7 PB of data from 460 instruments worldwide, processing it into more than 11,000 diverse data products using the Network Common Data Form (NetCDF) for machine-independent accessibility. The primary challenge addressed in this paper is the efficient management and distribution of vast and diverse datasets essential for the climate research community, enhancing accessibility through advanced tools like Data Discovery. The ADC has developed advanced infrastructure and software architecture to handle the continuous influx of heterogeneous data to enhance data discoverability, resulting in increased scientific collaboration. In 2023, users from over 34 countries downloaded and utilized ARM data, resulting in 1,455 publications. The ADC’s efforts have significantly improved the discoverability and usability of atmospheric data, fostering extensive scientific research and collaboration. This paper details the solutions implemented by the ADC team for efficient data discovery and distribution, and it demonstrates ARM’s capability of staging processed data for scientific analysis.

Shah, Chirag [ORNL] (ORCID:0000000203145737)↗

Preliminary Analysis of Nuclear-Powered Data Center Scenarios

This report provides a comprehensive analysis of the potential for nuclear energy to meet the growing energy demands of data centers (DCs). It evaluates the technical, economic, and socio-environmental implications of coupling Nuclear Power Plants (NPPs) with DCs, providing initial responses to several key research questions: What is the potential increased energy demand from DCs in the U.S., in the short, medium and long term? The U.S. is experiencing a rapid increase in energy demand from DCs, with projections indicating a total increase of 24-74 GWy(e) by 2028. Meeting this demand with nuclear energy would require 27–85 GWe of installed capacity. While this surge is expected to slow in the long term, the DC industry needs reliable, scalable, and clean energy sources. How much nuclear capacity can be deployed to meet DC demand and in which timeframe? Several pathways for increasing nuclear capacity were identified, including uprates, restarts of recently retired reactors, power purchase agreements with existing fleet, and new construction. Approximately 20‒28 GWe of nuclear capacity could be dedicated to DCs by the early 2030s. How much High Assay Low Enriched Uranium (HALEU) would be needed to support some nuclear deployment scenarios for DCs? Meeting the deployment targets announced by Google and Amazon for the Kairos Power Fluoride-Salt-Cooled High-Temperature Reactor or KP-FHR (~500 MWe by 2035) and the Xe-100 (~1 GWe by 2040), respectively, requires ramping up 19.75% enriched HALEU production to ~6 t/yr by 2040. What types of nuclear energy/DC coupling options exist, and what are the different benefits/challenges? Five coupling options were analyzed, ranging from grid-connected configurations to colocated, behind-the-meter setups. Key design considerations include the proximity to high- and/or medium-voltage transmission lines, the desired internal fault tolerance, and the sources of alternative/backup power during outages. Each coupling option offers unique benefits and challenges in terms of reliability, system costs, regulation, timeline, etc. A list of NPP/DC deployment scenarios was developed, considering existing or newly built NPP or DC projects. Colocated DCs with new small modular reactors or large reactors on greenfield and brownfield sites are the focus of this report. What types of reactors, especially what size, may be incentivized by DCs? Reactor sizing optimization revealed that the ideal reactor size and number of units depend on DC demand, coupling configurations defined in this report, and other economic factors. Larger reactors are preferred for high-demand DCs and grid-connected systems, while larger number of smaller reactors are better suited for DC configurations without grid backup. Which sites may be compatible with co-located nuclear-powered DCs? Siting those projects is a complicated evaluation factoring local water resources, grid connection availability and reliability, IT infrastructure, local work force, proximity to population zones, etc. For this effort greenfield and brownfield sites such as retired coal-fired plants were used to evaluate this question. This evaluation is not meant to recommend any particular site but it highlights key siting criteria and demonstrates large-scale site availability. What are the socio-economic impacts of co-located nuclear-powered DCs? Those projects generate substantial economic benefits to the local economy, particularly in urban settings. Hyperscale DCs colocated with nuclear power plants (sized around 1 GW of power) can create nearly 1,700 jobs for annual operations and more than 7,300 jobs among the supply chain and local businesses as a result of increased household spending. Rural projects also provide significant benefits, but at lower magnitudes compared to urban deployments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Astronomical Data Center Bulletin, volume 1, no. 1

Information about work in progress on astronomical catalogs is presented. In addition to progress reports, an upadated status list for astronomical catalogs available at the Astronomical Data Center is included. Papers from observatories and individuals involved with astronomical data are also presented.

Warren, W. H., Jr.↗

Exploring the Limits of Cooling for Extreme Heat Flux Applications: Data Centers and Power Electronic

We developed an Extreme Heat Flux Micro-cooler (EHFµ-C) capable of removing heat flux of ~1 kW/cm 2 with a small temperature rise ~10°C. This represents greater than 10× reduction in thermal resistance compared to the state-of-the-art single-phase cooling technologies (~0.5 cm 2 -°C/W) that greatly increases the efficiency, resulting in improved performance and reliability for microprocessors and power electronics. The EHFµ-Cooler utilizes liquid wicking (no pump) and thin-film evaporation in a 30 µm thick wick porous microstructure such as copper inverse opal (CIO), silicon and AlN pin fins along with a 3D manifold (copper wiremesh and silicon) with liquid routing and vapor extraction channels achieving an unprecedented vapor quality ~ >0.9. The proposed EHFµ-Cooler significantly reduces device temperature, resulting in 25-50% improvement in reliability and device performance. Based on very conservative estimates, the total energy saving for data centers due to improved performance can be 6 billion kWh/year (>$300M). Better cooling, leading to more efficient, higher performance and more reliable power electronics, would save the nation 3 Quad of primary energy in 2030. Just for automotive application, a 10% increase in fuel efficiency for SiC-based power electronics equates to >20 million gallons of fuel savings annually. The proposed EHFµ-Cooler technology ensures the United States maintains its technological lead in high-performance computing and high-power electronics, while at the same time improving the energy efficiency, and as a result reducing energy-related emissions such as greenhouse gases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Satellite Situation Center data system for magnetospheric science planning

Critical problems in planning coordinated observation campaigns for magnetospheric science include the need to predict time intervals when one or more observing satellites or ground stations will be connected along magnetic field lines to other observation sites, or when such sites will be located within magnetospheric regions of common interest. The Satellite Situation Center (SSC) was created at the National Space Science Data Center (NSSDC) during the International Magnetospheric Study in the 1970s to address these problems. The SSC Data System has evolved since that era to support potentially complex queries by SSC staff and has now been opened to NASA Science Internet access via the NSSDC On-line Data Information System (NODIS). The SSC software, ephemeris data base, and access modes are described for the Version 2.1 release in 1993.

Aist-Sagara, L.↗

Lunar laser ranging data deposited in the National Space Science Data Center: Filtered observations for 1971 July through 1971 December and unfiltered photon detections for 1972 January through 1972 June

Documentation to be used in conjunction with data deposited in the National Space Science Data Center is presented which concerns the filtered observations obtained during laser ranging operations between the McDonald Observatory and the Apollo 11, 14, and 15 reflectors, and the unfiltered photon detections. As part of the Lunar Laser Ranging Experiment, three widely separated reflector arrays were placed on the moon. Laser ranging equipment, both ground based on lunar based, is described, and coordinates of the intersection of the polar and transverse axes of the telescope are given. Filtered and unfiltered data are defined and discussed.

Mulholland, J. D.↗

Lunar laser ranging data deposited in the National Space Science Data Center normal points, filtered observations, and unfiltered photon detections

The lunar laser ranging project at McDonald Observatory provides the unique opportunity to acquire successfully precise range data for the earth-moon system. From the experiment's inception, the obligation was recognized to make these data available to the general scientific community in a reasonably useable form and in a realistic time frame. The documentation to be used in conjunction with the 1979 April deposit into the National Space Science Data Center which contains normal points, filtered observations and unfiltered photon stops for the months July through December, 1978 are reported.

Shelus, P. J.↗

Toward lower-diameter large-scale HPC and data center networks with co-packaged optics

We investigate the advantages of using co-packaged optics for building low-diameter, large-scale high-performance computing (HPC) and data center networks. The increased escape bandwidth offered by co-packaged optics can enable high-radix switch implementations of more than 150 switch ports, which can be combined with data rates of up to 400 Gb/s per port. From the network architecture perspective, the key benefits of using co-packaged optics in future fat-tree networks include (a) the ability to implement large-scale topologies of > <#comment/> 11 , 000 end points by eliminating the need for a third switching layer and (b) the ability to provide up to 4 × <#comment/> higher bisection bandwidth compared to existing solutions, reducing at the same time the number of required switch application-specific integrated circuits by > <#comment/> 80 % <#comment/> . From the network operation perspective, both reduced energy consumption and lower packet delays can be achieved since fewer hops are required; i.e., packets need to traverse fewer serializer/deserializer lanes and fewer switch buffers, which reduces the probability of contending with other packets and improves the tolerance of network congestion. The performance of the proposed architecture is evaluated via discrete-event simulations for a wide range of representative HPC synthetic-traffic cases that include both hotspot and non-hotspot scenarios. The simulation results suggest that co-packaged optics form a promising solution to keep up with bandwidth scaling in future networks, while the reduced number of switching layers can lead to significant mean packet delay improvements that start from 30% and reach up to 74% for high-load conditions.

Maniotis, Pavlos (ORCID:0000000244905253)↗