Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DISCRIMINATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Discriminating the source of high-energy positrons with AMS-02

We study the prospects for discriminating between the dark matter (DM) and pulsar origin of the PAMELA positron excess with the Alpha Magnetic Spectrometer AMS-02. We simulate the response of AMS-02 to positrons (and electrons) originating from DM annihilations, and determine the pulsar parameters (spin-down luminosity, distance and characteristic age) that produce a satisfactory fit to the mock AMS-02 data. It turns out that it is always possible to mimic a DM signal with pulsars. Although the fit in some cases requires values of spin-down luminosity and characteristic age different from those of known pulsars in the ATNF and Fermi-LAT catalogues, these catalogues are known to be incomplete, and therefore the pulsar interpretation can hardly be ruled out. We also show that if the positron excess is due to a single pulsar, it is always possible to find a DM candidate that provides a good fit to the mock AMS-02 data. The discrimination between the two scenarios will thus require a better knowledge of the underlying sources, or complementary data.

79 ASTRONOMY AND ASTROPHYSICS↗

Software realization of real-time neutrons and {gamma}-rays pulse shape discrimination using CUDA platform

The two pulse shape discrimination methods were implemented in real-time. The pulse gradient analysis method was implemented programmatically on PC. The method based on artificial neural network was programmatically implemented using CUDA platform. It is shown that both implementations can provide up to 10{sup 6} pulses per second processing performance. The results for pulse shape discrimination using polycrystalline stilbene and LiF detectors were shown. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficient Prompt Scintillation and Fast Neutron-Gamma Ray Discrimination Using Amorphous Blends of Difluorenylsilane Organic Glass and in-situ Polymerized Vinyltoluene

High performance radiation detection materials are an integral part of national security, medical imaging, and nuclear physics applications. Those that offer compositional and manufacturing versatility are of particular interest. In this work, we report a new family of radiological particle-discriminating scintillators containing bis(9,9-dimethyl-9H-fluoren-2- yl)diphenylsilane (compound “P2”) and in-situ polymerized vinyltoluene (PVT) that is phase stable and mechanically robust at any blend ratio. The gamma-ray light yield increases nearly linearly across the composition range, to ~16,400 photons/MeV at 75 % wt. P2. These materials are also capable of γ/n pulse shape discrimination (PSD) and between 20-50 % P2 loading are competitive with the PSD quality of commercially-available plastic scintillators. The 137 Cs scintillation rise and decay times are sensitive to P2 loading and approach the values for “pure” P2. Additionally, the radiation detection performance of P2-PVT blends can be made stable in 60°C air for at least 1.5 months with the application of a thin film of poly(vinylalcohol) to the scintillator surfaces.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hand-held UXO Discriminator

With prior funding (UX-1225, MM-0437, and MM-0838), we have successfully designed and built a cart-mounted Berkeley UXO Discriminator (BUD) and demonstrated its performance at various test sites (e.g., Gasperikova et al., 2007, 2009). It is a multi-transmitter multi-receiver active electromagnetic system that is able to discriminate UXO from scrap at a single measurement position, hence eliminates equirement of a very accurate sensor location. The cart-mounted system comprises of three orthogonal transmitters and eight pairs of differenced receivers (Smith et al., 2007). Receiver coils are located on ymmetry lines through the center of the system and see identical fields during the on-time of the pulse in all of the transmitter coils. They can then be wired in opposition to produce zero output during the n-ime of the pulses in three orthogonal transmitters. Moreover, this configuration dramatically reduces noise in the measurements by canceling the background electromagnetic fields (these fields are uniform ver the scale of the receiver array and are consequently nulled by the differencing operation), and by canceling the noise contributed by the tilt of the receivers in the Earth's magnetic field, and therefore reatly enhances receivers sensitivity to the gradients of the target.

54 ENVIRONMENTAL SCIENCES↗

Graphical methods for the sensitivity analysis in discriminant analysis

Similar to regression, many measures to detect influential data points in discriminant analysis have been developed. Many follow similar principles as the diagnostic measures used in linear regression in the context of discriminant analysis. Here we focus on the impact on the predicted classification posterior probability when a data point is omitted. The new method is intuitive and easily interpretative compared to existing methods. We also propose a graphical display to show the individual movement of the posterior probability of other data points when a specific data point is omitted. This enables the summaries to capture the overall pattern of the change.

97 MATHEMATICS AND COMPUTING↗

Speed tuning of motion segmentation and discrimination

Motion transparency requires that the visual system distinguish different motion vectors and selectively integrate similar motion vectors over space into the perception of multiple surfaces moving through or over each other. Using large-field (7 degrees x 7 degrees) displays containing two populations of random-dots moving in the same (horizontal) direction but at different speeds, we examined speed-based segmentation by measuring the speed difference above which observers can perceive two moving surfaces. We systematically investigated this 'speed-segmentation' threshold as a function of speed and stimulus duration, and found that it increases sharply for speeds above approximately 8 degrees/s. In addition, speed-segmentation thresholds decrease with stimulus duration out to approximately 200 ms. In contrast, under matched conditions, speed-discrimination thresholds stay low at least out to 16 degrees/s and decrease with increasing stimulus duration at a faster rate than for speed segmentation. Thus, motion segmentation and motion discrimination exhibit different speed selectivity and different temporal integration characteristics. Results are discussed in terms of the speed preferences of different neuronal populations within the primate visual cortex.

NASA Center ARC↗

Discriminative Methodology using the Unscented Transform in Special Euclidean Group SE(3) for Autonomous GN&C

Kalman filtering techniques usually compare a known dynamic model with some process noise to an updated, noisy measurement. Both sources of noise are generally assumed to be Gaussian and are filtered to obtain a more accurate estimate of the state of the system of interest. However, these methods assume that a relatively accurate dynamical model already exists. By including discriminative methodology to interpret differences in the predictive model and the measured states over time, an incorrect model can be corrected overtime, allowing a spacecraft to learn about its environment and adapt to changing conditions. In this paper, a discriminative unscented Kalman filter (DUKF) is introduced on the special Euclidean group SE(3) formulation framework. A spacecraft is initialized near a small body with no knowledge of its parameters, and using several consecutive conditional models the environment is studied and the filter is updated. The case study of a spacecraft in a slightly elliptical, inclined, relatively tight orbit around the irregular moon Phobos is simulated and discussed. The accuracy of this approach is quantifying the differences between the true state, the UKF with a poor model, and the DUKF.

GN&C↗

Plant-mediated partner discrimination in ectomycorrhizal mutualisms

Although ectomycorrhizal fungi have well recognized effects on ecological processes ranging from plant community dynamics to carbon cycling rates, it is unclear how actively plants are able to influence the structure of these fungal communities. To address this knowledge gap, we performed two complementary experiments to determine 1) whether ectomycorrhizal plants can discriminate among potential fungal partners, and 2) to what extent the plants might reward better mutualists. In experiment 1, split-root Larix occidentalis seedlings were inoculated with spores from three Suillus species (S. clintonianus, S. grisellus, and S. spectabilis). In experiment 2, we manipulated the symbiotic quality of Suillus brevipes isolates on split-root Pinus muricata seedlings by changing the nitrogen resources available, and used carbon-13 labeling to track host investment in fungi. In experiment 1, we found that hosts can discriminate in multi-species settings. The split-root seedlings inhibited colonization by S. spectabilis whenever another fungus was available, despite similar benefits from all three fungi. In experiment 2, we found that roots and fungi with greater nitrogen supplies received more plant carbon. Furthermore, our results suggest that plants may be able to regulate this symbiosis at a relatively fine scale, and that this regulation can be integrated across spatially separated portions of a root system.

59 BASIC BIOLOGICAL SCIENCES↗

Discriminating Nuclear Threats from Benign Sources in Gamma-ray Spectra using a Spectral Comparison Ratio Method

This manuscript presents a method for categorizing gamma-ray spectra as benign or threatening. It is widely believed that the goal of segregating gamma-ray spectra into benign and threatening populations can achieved with fewer counts than are required for confident characterization of a spectrum’s isotopic composition, while still providing improvement over count-based algorithms. This has potentially important implications on the detection of radiological and nuclear threats, where decisions must be made from analysis of count-starved spectra that dominate the landscape of monitoring special nuclear material transport and lost-or-stolen source search. We report here the method of Spectral Comparison Ratios (SCRs) which is useful in the targeted detection of specific gamma-ray signatures or signature classes. SCRs discriminate between benign and target sources by comparing counts in broad, pre-defined energy bins that are pre-determined using statistical discrimination criteria. The integral component of the SCR algorithm is the location and interdependence of the energy bins, and we discuss the statistical methods used for choosing their locations along with the decision criteria that maximally separate targets from benign sources.

algorithm development↗

Corelli : efficient single crystal diffraction with elastic discrimination.

Single crystal diffuse scattering provides one of the most powerful probes of short-range correlations on the 1-100 nm scale, which often are responsible for the extreme field response of many emerging phenomena of great interest. Accurate modeling of such complex disorder from diffuse scattering data however puts stringent experimental demands, requiring measurements over large volumes of reciprocal space with sufficient momentum and energy resolution. Here, we discuss the potential of the cross-correlation technique for efficient measurement of single crystal diffuse scattering with energy discrimination, as will be implemented in a novel instrument, Corelli. Utilizing full experiment simulations, we show that this technique readily leads up to a fifty-fold gain in efficiency, as compared to traditional methods, for measuring single crystal diffuse scattering over volumes of reciprocal space with elastic discrimination.

36 MATERIALS SCIENCE↗

Spectral parameter power series representation for Hill's discriminant

We establish a series representation of the Hill discriminant based on the spectral parameter power series (SPPS) recently introduced by Kravchenko. We also show the invariance of the Hill discriminant under a Darboux transformation and employing the Mathieu case the feasibility of this type of series for numerical calculations of the eigenspectrum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calreticulin discriminates the proximal region at the N-glycosylation site of Glc1Man9GlcNAc2 ligand

Calreticulin (CRT) is well known as a lectin-like chaperone that recognizes Glc1Man9GlcNAc2 (G1M9)-glycoproteins in the endoplasmic reticulum (ER). However, whether CRT can directly interact with the aglycone moiety (protein portion) of the glycoprotein remains controversial. To improve our understanding of CRT interactions, structure-defined G1M9-derivatives with different aglycones (–OH, –Gly–NH{sub 2}, and –Gly–Glu–{sup t}Bu) were used as CRT ligands, and their interactions with recombinant CRT were analyzed using thermal shift analysis. The results showed that CRT binds strongly to a G1M9-ligand in the order –Gly–Glu–{sup t}Bu > –Gly–NH{sub 2} > –OH, which is the same as that of the reglucosylation of Man9GlcNAc2 (M9)-derivatives by the folding sensor enzyme UGGT (UDP-glucose: glycoprotein glucosyltransferase). Our results indicate that, similar to UGGT, CRT discriminates the proximal region at the N-glycosylation site, suggesting a similar mechanism mediating the recognition of aglycone moieties in the ER glycoprotein quality control system. - Highlights: • Glc1Man9GlcNAc2 (G1M9) ligands with different aglycones were chemically prepared. • Calreticulin (CRT) discriminates the aglycone of Glc1Man9GlcNAc2 (G1M9) ligand. • CRT binds with G1M9 ligands in a similar manner to folding sensor enzyme.

60 APPLIED LIFE SCIENCES↗

Pathologic Nodal Classification Is the Most Discriminating Prognostic Factor for Disease-Free Survival in Rectal Cancer Patients Treated With Preoperative Chemoradiotherapy and Curative Resection

Purpose: We retrospectively evaluated the effects of clinical and pathologic factors on disease-free survival (DFS) with the aim of identifying the most discriminating factor predicting DFS in rectal cancer patients treated with preoperative chemoradiotherapy (CRT) and curative resection. Methods and Materials: The study involved 420 patients who underwent preoperative CRT and curative resection between August 2001 and October 2006. Gender, age, distance from the anal verge, histologic type, histologic grade, pretreatment carcinoembryonic antigen (CEA) level, cT, cN, cStage, circumferential resection margin, type of surgery, preoperative chemotherapy, adjuvant chemotherapy, ypT, ypN, ypStage, and tumor regression grade (TRG) were analyzed to identify prognostic factors associated with DFS. To compare the discriminatory prognostic ability of four tumor response-related pathologic factors (ypT, ypN, ypStage, and TRG), the Akaike information criteria were calculated. Results: The 5-year DFS rate was 75.4%. On univariate analysis, distance from the anal verge, histologic type, histologic grade, pretreatment CEA level, cT, circumferential resection margin, type of surgery, preoperative chemotherapeutic regimen, ypT, ypN, ypStage, and TRG were significantly associated with DFS. Multivariate analysis showed that the four parameters ypT, ypN, ypStage, and TRG were, consistently, significant prognostic factors for DFS. The ypN showed the lowest Akaike information criteria value for DFS, followed by ypStage, ypT, and TRG, in that order. Conclusion: In our study, ypT, ypN, ypStage, and TRG were important prognostic factors for DFS, and ypN was the most discriminating factor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single electron–hole pair sensitive silicon detector with surface event discrimination

Here, we demonstrate single electron-hole pair resolution in a single-sided, contact-free 1 cm$^2$ by 1 mm thick Si crystal operated at 48 mK, with a baseline energy resolution of 3 eV. This crystal can be operated at voltages in excess of $\pm50$ V, resulting in a measured charge resolution of 0.06 electron-hole pairs. The high aluminum coverage ($\sim$70%) of this device allows for the discrimination of surface events and separation of events occurring near the center of the detector from those near the edge. We use this discrimination ability to show that dark events seen in previous detectors of a similar design are likely dominated by charge leakage along the side wall of the device. We saw only a small reduction in dark event rate with this biasing scheme, further suggesting that sidewall and edge-dominated processes are responsible for the majority of these events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generalized method for the optimization of pulse shape discrimination parameters

Organic scintillators exhibit fast timing, high detection efficiency for fast neutrons and pulse shape discrimination (PSD) capability. PSD is essential in mixed radiation fields, where different types of radiation need to be detected and discriminated. In neutron measurements for nuclear security and non proliferation effective PSD is crucial, because a weak neutron signature needs to be detected in the presence of a strong gamma-ray background. Here, the most commonly used deterministic PSD technique is charge integration (CI). This method requires the optimization of specific parameters to obtain the best gamma-neutron separation. These parameters depend on the scintillating material and light readout device and typically require a lengthy optimization process and a calibration reference measurement with a mixed source. In this paper, we propose a new method based on the scintillation fluorescence physics that enables to find the optimum PSD integration gates using only a gamma-ray emitter. We demonstrate our method using three organic scintillation detectors: deuterated trans-stilbene, small-molecule organic glass, and EJ-309. In all the investigated cases, our method allowed finding the optimum PSD CI parameters without the need of iterative optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Discriminating Underground Nuclear Explosions Leading To Late-Time Radionuclide Gas Seeps

Utilizing historical data from the U.S. nuclear test program and freely available barometric pressure data, we performed an analytical barometric-pumping efficiency analysis to determine factors resulting in late-time radionuclide gas seeps from underground nuclear explosions. In this work, we considered 16 underground nuclear explosions with similar geology and test setup, of which five resulted in the measurement of late-time radionuclide gas concentrations at the ground surface. Additionally, the factors we considered include barometric frequency and amplitude, depth of burial, air-filled porosity, intact-rock permeability, fracture aperture, and fracture spacing. The analysis indicates that the best discriminators of late-time radionuclide gas seeps for these explosions are barometric frequency and amplitude and air-filled porosity. While geologic information on fracture aperture and spacing is not available for these explosions, the sensitivity of barometric-pumping efficiency to fracture aperture indicates that it would likely also be a good discriminator.

58 GEOSCIENCES↗

Study on Mass Discrimination Effect of Resonance Ionization Mass Spectrometry Using an Inductively Coupled Plasma as an Atomic Source (ICP-RIMS)

We have proposed a novel concept of Resonance Ionization Mass Spectrometry using an Inductively Coupled Plasma as an Atomic Source (ICP-RIMS). Isotope ratio analysis using ICP-RIMS is expected to be a convenient and precise technique with high throughput. However, the mass discrimination effect caused from difference in kinetic energy of neutral atoms in ICP-RIMS is crucial for precise isotope analysis. We, therefore, investigated the atom kinetic energy distribution introduced into the laser ionization region. The mass-dependent kinetic energy was confirmed in the initial kinetic energy distributions. We preliminary estimated a mass discrimination effect caused by mass-dependent kinetic energy in ICP-RIMS for various detector sizes. We proposed that this effect can be suppressed by selecting the appropriate detector size and adopting the scanning mode of the deflecting voltage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗