Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DISASTER SIMULATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

200 records · Page 12

Analysis of the Impact of Radiation on Cameras and Robotic Perception - 19242

Robotic systems are increasingly used for inspection, maintenance, and disaster assistance for nuclear power plants. These robots utilize increasingly high levels of autonomy to operate in environments that are unsafe for humans to operate the robot in or require more precise control over the robot than a human can offer. In these cases, the robot must include perception and computation components to autonomously sense and navigate through the environment to fulfill its mission. This difficult task is complicated by radiation interfering with sensors' operation. The impact of this interference is largely unexplored, as existing works on radiation interference on sensors focus on estimating the incident radiation, rather than how it impacts a robotic system using the sensor. In this work, we seek to quantify and describe the impact of radiation on cameras, and how the radiation affects robotic performance. In this paper we study cameras that are suitable for small, lightweight unmanned aerial vehicles (UAVs) that are increasingly deployed to fly in confined areas in emergencies, where the surrounding environment is unsafe for workers to operate. These small UAVs lack the payload capacity to carry significant radiation shielding, so any onboard sensors will be affected by radiation. In the case of cameras, this radiation appears as noise in the camera imagery. This noise will interfere with the UAV's operation, by obscuring obstacles and interfering with localization and optical flow algorithms that detect detailed features in the environment. To date, there is a lack of information on how the radiation noise in the camera image impacts the overall robot system performance Existing work focuses on estimating the amount of incident radiation by measuring the corruption in the images. However, these works suffer several shortcomings for robotic systems. First, a robot must be able to successfully navigate its environment during a successful mission, and merely quantifying the amount of radiation noise in an image does not adequately explain how it may interfere with higher level navigation and perception tasks. Second, radiation estimation procedures rely on focusing the camera on a known and static background. This is unsuitable for robotic exploration tasks, where the robot frequently moves around an unknown environment that may be dynamically changing. Our work contains two contributions that address these shortcomings. First, we conduct a detailed analysis of the noise radiation causes in cameras by exposing cameras that are commonly used on UAVs [e.g., small form factor complementary metal-oxide-semiconductor (CMOS) cameras] to varying levels of radiation that may be present in emergency scenarios. From this exposure, we quantify not only how much noise is present, but quantify its appearance. By quantifying the appearance and amount of noise in a camera image, researchers can design mitigation strategies for the corruption, so that their robotic systems can operate in these challenging environments. Second, we demonstrate how to leverage this experimental data in robotic simulations. Using data from the first set of experiments allows us to test and verify the robots in simulation. Using simulators allows us to verify the robots will perform as expected during critical times without needing expensive test equipment or damaging valuable robot prototypes. Other researchers using robots for exploration of irradiated environments will benefit from our research by incorporating similar noise models in their research. 1 Southwest Research Institute{sup R} is a registered trademark of Southwest Research Institute in the United States and/or other countries. This will increase the reliability of robotic systems prior to deployment in emergency situations, which will in turn increase their effectiveness and speed the development of robots that would otherwise need expensive and time-consuming test procedures to validate. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Selective Shielding Bone Marrow: An Approach to Create Personal Protective Equipment for Gamma Radiation

Many casualties of the Hiroshima and Nagasaki atomic bombs, and many of the firefighters who first responded to the Chernobyl nuclear power plant accident, became ill with acute radiation syndrome (ARS). Most of the people who do not recover from ARS will die within a few weeks to a few months after exposure, with the primary cause of death being the destruction of the body's bone marrow (BM). This is exemplified by the Chernobyl firefighters, the majority of whom received whole body doses between 0.8 and 10 Gy, and the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) final report on the disaster concluded that the underlying cause of death of all 28 firefighters who succumbed to ARS was from bone marrow failure. BM is comprised of hematopoietic stem cells (HSCs) which are responsible for the constant renewal of blood cells. Due to their high rate of proliferation, HSCs are especially vulnerable to ionizing radiation, but are endowed with remarkable regenerative potential. Owing to their central role in blood production, lethal irradiation of HSCs leads to death from severe anemia, infection and internal bleeding. This relationship between high doses of radiation and HSC apoptosis has led to the use of HSC transplantation as a life-saving intervention in cases of acute exposure. This is demonstrable in medical practice, where thousands of individuals have undergone supra-lethal Total Body Irradiation (TBI) for purposes of cancer therapy, and were rescued by well-matched BM transplantation. Indeed, life-threatening damage may be reversed by BM transplantation in individuals receiving doses of radiation of up to 10 Gy. At doses > 10 Gy, damage to gastrointestinal (GI) tissue may become a limiting factor in survival. Remarkably, in the common procedure of BM transplantation, the number of HSCs extracted from a single active BM site containing less than 5% of the donor's BM tissue is sufficient to support the complete reconstitution of the HSC compartment in a lethally irradiated recipient. This capacity of BM to expand and replenish is due to the high regenerative potential of the HSCs it harbors. In contrast to mature blood cells, which are dispersed throughout the body, HSCs are confined to the bones, allowing for effective targeted shielding. This has been confirmed in several animal models, where sparing the HSC-rich area of a subject receiving otherwise full-body irradiation is sufficient to support hematopoietic functions and allow survival. Approximately 48% of the human body's active BM is contained within the lumbar vertebrae and the pelvic region. This high concentration of BM makes the pelvic region an ideal area to shield for preventing the serious hematopoietic effects of radiation exposure. Stem-cell rich tissues like active BM are also more sensitive to the stochastic effects (i.e. cancer) of radiation exposure. The high amount of BM in the pelvic region, combined with the presence of the sensitive gastrointestinal system and female gonads in this same area of the body allows for the possibility of significantly reducing stochastic effects of radiation by limiting radiation exposure to this vital area. Thus, shielding this region holds great promise for both acute and protracted exposures. Thus, a specialized radiation shielding device for the protection of active BM concentrations is presented here. This belt-like selective shielding device focuses on the protection of BM that is present in the pelvis and hip bones, protecting the medullary volume from which BM is commonly extracted for transplantation (i.e. the iliac bones) while allowing relatively unhindered movement of the wearer. In order to optimize the use of shielding materials towards the protection of active BM, the shielding uniquely brings into account the natural shielding properties of human tissue, with thickness being inversely related to the thickness and radiation attenuation of the underlying tissue at each point surrounding the area being protected. The findings resulting from both experimental and simulation testing of this selective shielding device are presented here.

61 RADIATION PROTECTION AND DOSIMETRY↗