Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DIRECT ENERGY CONVERSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Design optimization of integrated cooling inserts in modular Fischer-Tropsch reactors

Sustainable production of liquid fuels and feedstocks from atmospheric CO 2 through carbon recycling technologies is necessary to broaden decarbonization efforts and further reduce global emissions. Fischer–Tropsch (FT) reactors can address this challenge by providing storable, high-value liquid hydrocarbon fuels and feedstocks from syngas generated through reductive CO 2 utilization. FT technology, however, is most cost effective at large-scale, fixed-site plants and does not effectively address the smaller, globally distributed CO 2 point sources. Alternatively, smaller, modular reactors can be composed together to the specific scale of the emission source, yielding a flexible solution that enables more widespread deployment. In these modular reactors, thermal management using a finned cooling insert embedded within the catalyst matrix is critical to maintaining the performance and viability. Thus, in this work, topology optimization is used to determine the cooling insert geometry that maximizes reactor productivity while preventing auto-thermal runaway. Optimal designs are generated for varying number of constituent fins and over a range of maximum operating temperatures. Constraints including minimum feature length-scales and prescribed cooling insert material are imposed on the designs to enhance manufacturability. The impact of design features such as insert tapering and increased length scale hierarchy is automatically revealed by the systematic design framework employed. Here, this approach thus generates novel optimal geometries while automating, accelerating, and enhancing the design process compared to traditional heuristic approaches for cooling insert design in modular FT reactors.

30 DIRECT ENERGY CONVERSION↗

Decarbonizing nitrogen fertilizer production via the electrochemical nitrogen oxidation reaction

Nitric acid is an important commodity chemical with extensive applications in both agricultural and industrial sectors. However, current production methods involve a combination of the Haber–Bosch and Ostwald processes, which are both energy and carbon emission intensive. The electrochemical nitrogen oxidation reaction (NOR) to produce nitric acid or nitrates shows great potential as an environmentally friendly method for producing fertilizers under mild conditions. The key to progress in this field lies in understanding the fundamental mechanistic insights and establishing robust experimental methods, which is essential for the efficient design and synthesis of electrocatalysts for NOR. Additionally, poor gas mass transport in conventional electrochemical reactors at present lead to lower NOR activity, thereby limiting the progress in this field. In this work, we present a synergistic computational and experimental approach to map out the potential chemical and electrochemical steps and determine the energetics on PtO 2 catalyst to gain mechanistic insights into NOR. Here, this study marks the first attempt to perform NOR in a vapor-fed reactor designed using advanced (additive) manufacturing. The vapor-fed reactor significantly improved the N 2 mass transport to the catalyst, allowing us to report the highest rate for nitrate production to date at 3.3 μmol cm -2 h -1 at 2.01 V vs RHE.

30 DIRECT ENERGY CONVERSION↗

Recent developments in catalyst-related PEM fuel cell durability

Cost and durability remain the two major barriers to the widespread commercialization of polymer electrolyte membrane fuel cell (PEMFC)-based power systems, especially for the most impactful but challenging fuel cell electric vehicle (FCEV) application. Commercial FCEVs are now on the road; however, their PEMFC systems do not meet the cost targets established by the U.S. Department of Energy, primarily due to the high platinum loading needed on the cathode to achieve the requisite performance and lifetime. Furthermore, while the activities of a number of commercial Pt-based alloy cathode catalysts exceed the beginning-of-life (BOL) targets, these activities, and the overall cathode performance, degrade via a variety of mechanisms described herein. Degradation is mitigated in current FCEVs by utilizing a cathode catalyst with a lower BOL activity (e.g., much lower transition metal alloy content and larger BOL nanoparticle size), necessitating higher catalyst loadings, and through the utilization of system controls that avoid conditions known to exacerbate degradation processes, such as limiting the fuel cell stack voltage range. The design and development of active and robust materials and eliminating the need for vehicle mitigation strategies would greatly simplify the operating system, allowing for greater transient operation, avoiding large hybridization, and curtailing of fuel cell power. Although system mitigation strategies have provided the near-term pathway for FCEV commercialization, material-specific solutions are required to further reduce costs and improve operability and efficiency. Future material developments should focus on stabilization of the electrode structure and minimization of the catalyst particle susceptibility to dissolution caused by oxide formation and reduction over PEMFC cathode-relevant operating potentials plus minimization of support corrosion. Ex situ accelerated stress tests have provided insight into the processes responsible for material and performance degradation and will continue to provide useful information on the relative stability of materials and benchmarks for robust and stable materials-based solutions not requiring system mitigation strategies to achieve adequate lifetime.

25 ENERGY STORAGE↗

A comprehensive experimental and kinetic modeling study of di-isobutylene isomers: Part 2

A wide variety of high temperature experimental data obtained in this study complement the data on the oxidation of the two di-isobutylene isomers presented in Part I and offers a basis for an extensive validation of the kinetic model developed in this study. Due to the increasing importance of unimolecular decomposition reactions in high-temperature combustion, we have investigated the di-isobutylene isomers in high dilution utilizing a pyrolysis microflow reactor and detected radical intermediates and stable products using vacuum ultraviolet (VUV) synchrotron radiation and photoelectron photoion coincidence (PEPICO) spectroscopy. Additional speciation data at oxidative conditions were also recorded utilizing a plug flow reactor at atmospheric pressure in the temperature range 725-1150 K at equivalence ratios of 1.0 and 3.0 and at residence times of 0.35 s and 0.22 s, respectively. Combustion products were analyzed using gas chromatography (GC) and mass spectrometry (MS). Ignition delay time measurements for di-isobutylene were performed at pressures of 15 and 30 bar at equivalence ratios of 0.5, 1.0, and 2.0 diluted in 'air' in the temperature range 900-1400 K using a high-pressure shock-tube facility. New measurements of the laminar burning velocities of di-isobutylene/air flames are also presented. The experiments were performed using the heat flux method at atmospheric pressure and initial temperatures of 298-358 K. Moreover, data consistency was assessed with the help of analysis of the temperature and pressure dependencies of laminar burning velocity measurements, which was interpreted using an empirical power-law expression. Electronic structure calculations were performed to compute the energy barriers to the formation of many of the product species formed. The predictions of the present mechanism were found to be in adequate agreement with the wide variety of experimental measurements performed.

09 BIOMASS FUELS↗

Development of algorithms for augmenting and replacing conventional process control using reinforcement learning

Here, this work seeks to allow for the online operation and training of model-free reinforcement learning (RL) agents but limit the risk to system equipment and personnel. The parallel implementation of RL alongside more conventional process control (CPC) allows for the RL algorithm to learn from CPC. The past performance of both methods are assessed on a continuous basis allowing for a transition from CPC to RL and, if needed, transitioning back to CPC from RL. This allows for the RL algorithm to slowly and safely assume control of the process without significant degradation in control performance. It is shown that the RL can derive a near optimal policy even when coupled with a suboptimal CPC. It is also demonstrated that the coupled RL-CPC algorithm learns at a faster rate than traditional RL methods of exploration while the algorithm’s performance does not deteriorate below CPC, even when exposed to an unknown operating condition.

30 DIRECT ENERGY CONVERSION↗

Half-cell electrode assessments of a crossover-tolerant direct methanol fuel cell with a platinum group metal-free cathode

In this work, a platinum group metal- free (PGM-free) Fe-N-C oxygen reduction reaction (ORR) catalyst derived from metal organic framework precursors (Fe-MOF) is evaluated at the cathode side of a direct methanol fuel cell (DMFC). A wide range of methanol concentrations were used, and the performance of the DMFC using air was evaluated and compared to a commercial Pt/C cathode. We conducted our tests with a custom, integrated H 2 reference electrode that separately provided the anode and cathode overpotentials. This allowed us to perform a Tafel analysis on both electrodes and understand the dominant polarizations involved at the PGM-free cathode and the PtRu/C anode. Overall, we achieved a high cell performance using a Fe-N-C based catalyst under liquid methanol and air operation with a peak power density of 111 mW/cm 2 , where the cathode presented a markedly larger contribution to the voltage loss versus the anode. Additionally, we used nanoscale X-ray computed tomography (nano-CT) to image the Fe-N-C cathode and investigate the ionomer and pore size distributions allowing us to identify areas of improvement for catalyst layer fabrication.

30 DIRECT ENERGY CONVERSION↗

Enhancing the activity of Fe-N-C oxygen reduction reaction electrocatalysts by high-throughput exploration of synthesis parameters

Here, the most active class of platinum group metal-free (PGM-free) oxygen reduction reaction (ORR) electrocatalysts in acidic electrolytes are those synthesized by heat treatment of iron, carbon, nitrogen precursors (Fe-N-C). Due to the large number of possible precursor compounds, a small fraction of the synthesis variable space has been explored. Correlation of synthesis variables with Fe speciation and ORR activity has been limited. In this work, an automation platform and a multi-port ball-milling were utilized to evaluate the effects of synthesis variables, such as identity of iron precursor, iron loading, and carbon and nitrogen sources on the ORR activity of iron -nitrogen-carbon catalysts in acidic electrolyte. The ORR activity is correlated with catalyst Fe speciation determined using Fe K-edge X-ray absorption spectroscopy (XAFS).

30 DIRECT ENERGY CONVERSION↗

Consequences of plane-strain and plane-stress assumptions in fully coupled chemo-mechanical Li-ion battery models

In Li-ion battery research, it is common to simulate chemo-mechanical phenomena in reduced dimensions (e.g., 2-D) as opposed to fully resolve these complex physics in 3-D. It is common to assume either (1) the out-of-plane strain is negligible (commonly referred to as plane-strain), or (2) the out-of-plane stress is negligible (commonly referred to as plane-stress). However, there is typically little consideration as to the quantitative consequences of these approximations. Furthermore, the influence of these out-of-plane assumptions can be compounded and convoluted when chemo-mechanics models implement so-called “fully coupled” formulations, where the local species concentrations influence the stress-state and the stress-state influences the local species fluxes. Here, the present manuscript explores the implications of using plane-stress and plane-strain assumptions in 2-D as compared to simulating a full 3-D electrode particle. This comparative study includes simulating both isotropic and anisotropic particle intercalation where the particles can be surrounded by either a liquid or solid electrolyte. Additionally, common Li-ion battery-model metrics such as the state-of-stress, intercalation fraction distribution, and specific capacity are compared, while also considering the effects of particle size and C-rate. As alternatives to the pure plane-strain and plane stress approximations, two modified plane-strain assumptions are found to better approximate the fully coupled chemo-mechanical 3-D behavior.

25 ENERGY STORAGE↗

Improving operational flexibility of integrated energy system with uncertain renewable generations considering thermal inertia of buildings

Insufficient flexibility in system operation caused by traditional "heat-set" operating modes of combined heat and power (CHP) units in winter heating periods is a key issue that limits renewable energy consumption. In order to reduce the curtailment of renewable energy resources through improving the operational flexibility, a novel optimal scheduling model based on chance-constrained programming (CCP), aiming at minimizing the lowest generation cost, is proposed for a small-scale integrated energy system (IES) with CHP units, thermal power units, renewable generations and representative auxiliary equipments. In this model, due to the uncertainties of renewable generations including wind turbines and photovoltaic units, the probabilistic spinning reserves are supplied in the form of chance-constrained; from the perspective of user experience, a heating load model is built with consideration of heat comfort and inertia in buildings. To solve the model, a solution approach based on sequence operation theory (SOT) is developed, where the original CCP-based scheduling model is tackled into a solvable mixed-integer linear programming (MILP) formulation by converting a chance constraint into its deterministic equivalence class, and thereby is solved via the CPLEX solver. We report the simulation results on the modified IEEE 30-bus system demonstrate that the presented method manages to improve operational flexibility of the IES with uncertain renewable generations by comprehensively leveraging thermal inertia of buildings and different kinds of auxiliary equipments, which provides a fundamental way for promoting renewable energy consumption.

30 DIRECT ENERGY CONVERSION↗

One-dimensional, transient modeling of a fixed-bed regenerator as a replacement for recuperators in supercritical CO 2 power cycles

Fixed-bed regenerators may be a low cost alternative to recuperators for supercritical CO 2 power cycles. However, the transient nature of regenerators operating in sCO 2 power cycles has not been previously characterized. This study details a one-dimensional, transient model of a fixed-bed regenerator that captures phenomena such as local fluid properties and heat transfer coefficients, entrained fluid heat capacity, and the effects of conservation of mass during process switching. The model is validated with experimental results of a 10 kWth regenerator. This comparison shows that the model predicts temperature as a function of both time and space exceptionally well. The model predicts effectiveness, heat transfer, and discharge temperatures within 5%, and predicts pressure drop and fluid carryover within 10%. This model could be used in future studies to simulate regenerators within a supercritical CO 2 power cycle.

30 DIRECT ENERGY CONVERSION↗

A novel triple power cycle featuring a gas turbine cycle with supercritical carbon dioxide and organic Rankine cycles: Thermoeconomic analysis and optimization

In this study, a novel triple power cycle is proposed where waste heat from a gas turbine cycle is utilized to drive a supercritical carbon dioxide (s-CO 2 ) recompression cycle and a recuperative organic Rankine cycle (ORC) in sequence. A detailed thermoeconomic model is developed and implemented in MATLAB to evaluate the performance of the proposed cycle under different operating conditions. Optimization using a particle swarm optimization (PSO) algorithm is performed to minimize the levelized cost of electricity (LCOE) and determine the optimum design conditions of the cycle. The optimization results show that for a 100 MW cycle, the overall thermal efficiency and LCOE are 0.521 and $\$52.819$/MWh, respectively. The turbine inlet temperature of the gas turbine and s-CO 2 cycles are found as the most influential parameters on the thermoeconomic performance of the triple cycle. The proposed triple cycle shows an excellent waste energy recovery potential and superiority over a very thermodynamically efficient cycle from the literature, which included a gas turbine topping cycle and a complex cascade s-CO 2 power cycle used a bottoming cycle. As a result, the proposed triple cycle shows up to 0.9% points higher efficiency while it has fewer heat exchangers and turbomachinery than the cycle from the literature.

30 DIRECT ENERGY CONVERSION↗

Thermal performance of an absorption-assisted two-stage ejector air-to-water heat pump

In this work, a gas-fired air-to-water ejector heat pump (EHP) for domestic hot water production is proposed and analyzed thermodynamically. The COP of the EHP is improved by using binary fluids (HFE7500 and water), and the high backpressure in the primary ejector (first-stage) is actively controlled by either a second-stage ejector and/or a LiBr-H 2 O absorption subsystem. A thermodynamic model is established for analysis and performance evaluation. A case study shows the backpressure of the first-stage ejector is reduced by 53.5%, and the backpressure control using the second-stage ejector increases the system COP by 21.0% compared with that using LiBr-H 2 O absorption. Parametric studies are conducted to investigate the roles of the first-stage ejector, the second-stage ejector, and the LiBr-H 2 O absorption subsystem. The first-stage ejector plays a dominant role in the EHP system performance. The EHP’s heating COP can reach 2.0 with an entrainment ratio of 0.12 in the first-stage ejector. EHP performance can be improved with a high entrainment ratio and a low-temperature primary working fluid in the first-stage and second-stage ejectors, a low condensation temperature in the first-stage ejector, and a high generating temperature and a low concentration of the LiBr-H 2 O solution.

30 DIRECT ENERGY CONVERSION↗

Hybrid-energy approach enabled by heat storage and oxy-combustion to generate electricity with near-zero or negative CO 2 emissions

We assess a hybrid-energy approach that modifies a steam-turbine power plant to use renewable energy sources (electricity, plus options for geothermal and solar heat), plus fossil fuel (natural gas and coal) and/or waste biomass (e.g., Douglas fir woodchips). Heat storage allows heat to be created during periods of excess energy supply and for that heat to be converted to electricity when demanded. Excess electricity, such as from variable renewable energy (VRE), is used to generate oxygen for oxy-combustion furnaces that create very-hot, high-purity CO 2 that heats granular rock beds in insulated vessels. Cool CO 2 leaving the beds is dried, sent to compressors powered by excess VRE electricity, before being sent by pipeline to geologic CO 2 storage. Very-hot CO 2 transfers high-grade heat from storage to the power plant in a closed loop that returns medium-grade heat back to storage, allowing low- and medium-grade renewable-heat sources to be stacked beneath combustion heat, with all heat sources being converted to electricity at the same (high) thermal efficiency. Reliable, on-demand power may be generated with near-zero CO 2 emissions with fossil fuel and with negative CO 2 emissions with waste biomass. Our analyses show that with fossil fuel, up to 35% of gross power can be derived from renewable sources, while for waste biomass, it can be entirely derived from renewable sources. Because our approach has the potential to ensure that grids have a continuous supply of clean energy and because electricity is only generated once, when demanded, it could serve as an efficient alternative to bulk energy storage.

30 DIRECT ENERGY CONVERSION↗

Flow visualisation in real-size optical injectors of conventional, additised, and renewable gasoline blends

Research on renewable and alternative fuels is crucial for improving the energy and environmental efficiency of modern gasoline internal combustion engines. To highlight the influence of fuel rheological and thermodynamic properties on phase change and atomisation processes, three types of gasoline blends were tested. More specifically, the campaign comprised a reference gasoline, an ethanol/gasoline blend (10% v/v) representative of renewable fuels, and an additised gasoline sample treated with viscoelasticity-inducing agents. High-speed imaging of the transient two-phase flow field arising in the internal geometry and the near-nozzle spray region of gasoline injectors was performed employing Diffuse Backlight Illumination. The metallic body of a commercial injector was modified to fit transparent tips realising two nozzle layouts, namely a two-hole real size model resembling the Engine Combustion Network spray G injector and an enraged replica with an offset hole. Experiments were conducted at realistic operating conditions comprising an injection pressure of 100 bar and ambient pressures in the range of 0.1–6.0 bar to cover the entire range of chamber pressures prevailing in Gasoline Direct Injection engines. The action of viscoelastic additives was verified to have a suppressive effect on in-nozzle cavitation (6% reduction in cavitation extent) , while also enhancing spray atomisation at flash-boing conditions, in a manner resembling the more volatile gasoline/ethanol blends. Finally, persisting liquid ligaments were found to form after the end of injection for the additised sample, owing to the surfactant nature of the additives.

30 DIRECT ENERGY CONVERSION↗

Rapid Load Transition for Integrated Solid Oxide Fuel Cell - Gas Turbine (SOFC-GT) Energy Systems: A Demonstration of the Potential for Grid Response

Rapid load transition is an essential requirement for integrated energy systems to maintain grid resilience as more renewable resources are added to the grid. Integrated solid oxide fuel cell - gas turbine (SOFC-GT) systems can provide high efficiency and low carbon emissions over a broad range of turndown. These hybrids also have the potential to enable rapid grid response. The challenge has been to demonstrate effective control strategies to manage load transitions. In the present study, a load transition of ~50% was achieved in 10 s using a novel but simple strategy. Power demand on the SOFC and the GT were ramped down concurrently. During this transition, the SOFC anode fuel was manipulated to maintain SOFC fuel utilization while the cathode inlet air flow and temperature were also manipulated to thermally protect the SOFC. This study was conducted using the Hybrid Performance (Hyper) facility at the National Energy Technology Laboratory (NETL) in a co-simulation environment with the Idaho National Laboratory (INL)'s grid-simulation. The load ramping strategy was tested using a hardware-based cyber-physical simulation methodology. The results demonstrate a high-fidelity representation of SOFC-GT hybrid dynamics and validation of the control strategy. Thermal and electrochemical transients indicated that the SOFC was well protected during rapid load turndown without violating operability constraints. This demonstration revealed the non-linear nature of tightly coupled SOFC-GT system components, especially the non-linear response of SOFC cathode air flow and inlet temperature controls. These results highlight the needs and challenges in developing adaptive automatic controls for autonomous rapid load transitions. This work demonstrates that SOFC-GT hybrids are a viable option to provide the fast-ramping characteristics essential to accommodate high levels of variable renewable power while maintaining grid resilience, reliability, and environmental performance. The results also demonstrate the utility of co-simulation in advancing the tightly-coupled integrated energy systems needed to meet goals for zero-carbon power generation.

DIRECT ENERGY CONVERSION,POWER TRANSMISSION AND DI↗