Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DIAPHRAGM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

SU-E-T-312: Dosimetric Consideration for the Agility MLC When Planning Rotational SRT/SBRT Treatments

Purpose: To analyze the radiation transmission of the Agility MLC and make recommendation based on the MLC dosimetric characteristics for SRT, SBRT and VMAT planning Method and Materials: Agility MLC is the newest model from Elekta and has no back up diaphragm behind leaves for this generation. Leaves are single focused with rounded end; composed of leafs each 0.5cm wide, 9cm thick, constructed from tungsten alloy and provide low transmission <0.5%. Total radiation transmission from leaves and diaphragm is <0.13%. A 360degree arc was generated using iCom tools; leaves were programmed closed while keeping the diaphragm fully open to maximize the MLC transmission effect. Gafchromic EBT films were sandwiched between 4cm of solid water and situated at midplane to take dose measurement. 5000MU was delivered using 6MV VersaHD, various collimator angles, and a 5cm central axis offset was tested also. Films were scanned with Epson 10000XL scanner and analyzed using DoseLab Pro. Results: Due to the rounded leaf end and nature of rotation therapy, dose accumulation through the leaf gap is significant. By offsetting the leaf gap from central axis, this accumulation can be greatly reduced. There are dark bands showing accumulation of interleaf transmission which is improved by increasing collimator angle from 0 to 45dgree. However for 45 degree, in most cases, there are larger volumes sweeping under MLC alone, which needs considered planning. Conclusions: While inter-leaf leakage is minimized by using collimator angles greater than 0 degrees, the location of the leaf gap must also be managed. The leaf gap position becomes critically important when the treatment area is off axis such is the case when more than one PTV is being treated. With VMAT for SRT, SBRT becoming a more popular planning technique, special attention needs to be paid when initially setting up the field geometry.

60 APPLIED LIFE SCIENCES↗

WE-EF-303-02: BEST IN PHYSICS (JOINT IMAGING- THERAPY): A Comprehensive Simulation of Image Guided Beam Gating for Liver Tumor Treatments Using Scanned Proton Therapy

Purpose: To evaluate the effectiveness of image guided beam gating for PBS liver treatments under realistic breathing conditions. Methods: We have previously proposed a Beams’ Eye View (BEV) X-ray image system as an online motion monitoring device for deriving a gating signal for PBS proton therapy. Using dedicated 4D dose calculations (4DDC), in this work we have simulated gated liver treatments using three amplitude-based gating windows (10/5/3mm) based on motion extracted from BEV imaging of fiducial markers or the diaphragm. In order to improve motion mitigation, BEV guided gating has also been combined with either volumetric (VS) or layered (LS) rescanning. Nine 4DCT(MRI) liver data-sets have been used for the investigation, which not only consider realistic patient geometries but also motion variations between different breathing cycles. All 4D plans have been quantified in terms of plan homogeneity in the PTV (D5-D95), the total estimated treatment time and the beam-on duty cycle. Results: Neither gating nor rescanning can fully retrieve a comparable plan homogeneity to the static case, and considerable reductions of the duty cycle (<10%) were observed as a Result motion variations when small gating windows are used. However, once combined with rescanning, dose homogeneity within 1% of the static plan could be achieved with reasonable prolongation of the treatment time for all 9 subjects. No differences were observed between the efficacy of layered or volumetric re-scanning, or of gating signals extracted from fiducial or diaphragm motions. However, layered rescanning may be preferred over volumetric rescanning when performed in combination with gating as it is generally more time-efficient and dosimetrically robust to patient and motion variations Conclusion Combining BEV beam gating with rescanning is an efficient and effective approach to treating mobile liver tumours, and is equally effective if either the diaphragm or fiducial markers are used as motion surrogates.

60 APPLIED LIFE SCIENCES↗

MO-FG-BRA-09: Towards an Optimal Breath-Holding Procedure for Radiotherapy: Differences in Organ Motion During Inhalation and Exhalation Breath-Holds

Purpose: Breath-holding (BH) is often used to reduce organ motion during radiotherapy. The aim of this study was to determine the differences in pancreatic and diaphragmatic motion during BH between inhalation and exhalation BHs with variable lung volumes and to investigate whether motion increases/decreases during BH. Methods: Sixteen healthy volunteers were asked to perform four different 60-second BHs, from fully inflated to fully deflated lungs (i.e. lung volumes of: 100%, ∼70%, ∼30% and 0% of inspiratory capacity) three times (total of 192 BHs). During each BH, we obtained single-slice (coronal) magnetic-resonance scans with spatial resolution 0.93×0.93×8.0 mm3 and temporal resolution 0.6 s. We used 2-dimensional image correlation to obtain the motion of pancreatic head and diaphragm during BH. Motion magnitude in inferior-superior direction was obtained by determining the maximum displacement during BH. Results: Pancreatic and diaphragmatic drifts occurred during BH and were mostly in the superior direction. We observed significantly smaller pancreatic and diaphragmatic motion magnitudes in inferior-superior direction during exhalation BHs (BH{sub 30%} and BH{sub 0%}) compared to inhalation BHs (BH{sub 100%} and BH{sub 70%}). The mean motion magnitudes of the pancreatic head were 7.0, 6.5, 4.4 and 4.2 mm during BH{sub 100%}, BH{sub 70%}, BH{sub 30%} and BH{sub 0%}, respectively, and mean BH durations were 59.9, 59.1, 59.0 and 52.7 s. For the diaphragm, mean motion magnitudes were 9.8, 9.0, 5.6 and 4.3 mm, respectively. When considering 30-second BHs, as often used in the clinic, the motion was most pronounced during the first 10 s and excluding these from the analysis (yielding an effective BH period of 20 s) significantly reduced (P≤0.002) organ motion. Conclusion: Organ motion was significantly smaller during exhalation BHs compared to inhalation BHs. Also, motion was largest at the start of BH. Hence, waiting for 10 s may significantly decrease motion of the pancreas and diaphragm during treatment.

60 APPLIED LIFE SCIENCES↗

Grotesque: complex geometric arrangement of unreflected heu (93.15) metal pieces

The GROTESQUE experiments were designed specifically to develop and test neutronics for the GEOM subroutine of the 05R code. Two complex arrangements of various highly enriched uranium metal cylinders, rectangular parallelepipeds, and spheres were arranged in a circular formation on a steel diaphragm. A centerpiece was raised remotely through a hole in the steel diaphragm to achieve criticality. The first arrangement consisted of five major units, each major unit consisting of a stack of smaller uranium pieces. The second arrangement utilized nine major units, again consisting of stacks of smaller uranium pieces. The 9-unit arrangement is the only experiment discussed in this evaluation, since the five stack experiment never achieved criticality. The 9-unit arrangement is shown in Figure 1.1. The experiments were performed at the Oak Ridge Critical Experiments Facility (ORCEF) in June 1964. The 9-unit configuration was later used as part of the development process for early versions of KENO and a model representing a variation of this experiment (Sample Problem 7: GROTESQUE without the Diaphragm) is released with modern versions of SCALE for testing the proper installation of the KENO module. An experimental report for the GROTESQUE experiment has not been published; however there are two publications that describe the experiment (References 1 and 2). A separate reportc discussing the conversion of the 05r model into a KENO model was published; however, the author did not consult with the experimenter for GROTESQUE. This report is considered unreliable (except for dimensions) by the experimenter and should not be used to obtain information pertinent to the GROTESQUE experiment. The Oak Ridge Critical Experiments Facility (ORCEF) Logbook 15r contains the primary documentation from the experimenter for this experiment. The GROTESQUE arrangement of nine major units was evaluated an determined to be an acceptable benchmark experiment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Commissioning of helium injector for coupled radio frequency quadrupole and separated function radio frequency quadrupole accelerator

A project to study a new type of acceleration structure has been launched at Peking University, in which a traditional radio frequency quadrupole (RFQ) and a separated function radio frequency quadrupole are coupled in one cavity to accelerate the He+ beam. A helium injector for this project is developed. The injector consists of a 2.45 GHz permanent magnet electron cyclotron resonance ion source and a 1.16 m long low energy beam transport (LEBT). The commissioning of this injector was carried out and an onsite test was held in June 2013. A 14 mA He+ beam with the energy of 30 keV has been delivered to the end of the LEBT, where a diaphragm with the diameter of 7 mm is located. The position of the diaphragm corresponds to the entrance of the RFQ electrodes. The beam emittance and fraction were measured after the 7 mm diaphragm. Its rms emittance is about 0.14 π mm mrad and the fraction of He+ is about 99%.

43 PARTICLE ACCELERATORS↗

TH-E-17A-08: Estimation of Image Quality of 4-Dimensional Computed Tomography (4DCT) Via Fourier Analysis of Corresponding 1D Breathing Surrogate

Purpose: Motion artifacts are common in patient 4DCT, leading to an illdefined tumor volume with variation up to 110% or setting up a poor foundation with low imaging fidelity for tumor motion study. We developed a method to estimate 4DCT image quality by establishing a correlation between the severity of motion artifacts in 4DCT images and the periodicity of corresponding 1D respiratory wave-function (1DRW) surrogate used for 4DCT reconstruction. Methods: Fast Fourier Transformation (FFT) was applied to analyze 1DRW periodicity, defined as the sum of the 5 largest Fourier coefficients, ranging in 0–1. Distortional motion artifacts of cine-scan 4DCT at the junctions of adjacent couchposition scans around the diaphragm were identified in 3 categories: incomplete, overlapping and duplicate. To quantify these artifacts, the discontinuity of the diaphragm at the junctions was measured in distance and averaged along 6 directions in 3 orthogonal views. Mean and sum artifacts per junction (APJ) across the entire diaphragm were calculated in each breathing phase. To make the APJ inter-patient comparable, patientspecific motion was removed from APJ by dividing patient-specific diaphragmatic velocity (displacement divided by the mean period, from FFT analysis of the 1DRW) and the normalized APJ was defined as motion artifact severity (MAS). Twenty-five patients with free-breathing 10-phase 4DCT and corresponding 1DRW surrogate datasets were studied. Results: A mild correlation of 0.56 was found between 1DRW periodicity and 4DCT artifact severity. Higher MAS tends to appear around mid inhalation and mid exhalation and the lowest MAS tends to be around full exhalation. The breathing periodicity of >0.8 possesses minimal motion artifacts. Conclusion: The 1D-4D correlation provides a fast means to estimate 4DCT image quality. Using 1DRW signal, we can retrospectively screen out high-quality 4DCT images for clinical research (periodicity>0.8) and prospectively identify poor breathers as candidates of breath coaching prior to 4DCT scan. This research is in part supported by NIH (U54CA137788/132378). MC would like to thank MSKCC summer medical student research program supported by National Cancer Institute and hosted by Department of Medical Physics at MSKCC.

60 APPLIED LIFE SCIENCES↗

SU-F-I-40: Impact of Scan Length On Patient Dose in Abdomen/pelvis CT Diagnosis

Purpose: To analysis the impact of scan length on patient doses in abdomen/pelvis CT diagnosis of each hospital. Methods: Scan length of 7 hospitals from abdomen/pelvis CT diagnosis was surveyed in Korea. Surveyed scan lengths were additional distance above diaphragm and distance below pubic symphysis except for standard scan range between diaphragm and pubic symphysis. Patient dose was estimated for adult male and female according to scan length of each hospital. CT-Expo was used to estimate the patient dose under identical equipment settings (120 kVp, 100 mAs, 10 mm collimation width, etc.) except scan length. Effective dose was calculated by using tissue weighting factor of ICRP 103 recommendation. Increase rate of effective dose was calculated comparing with effective dose of standard scan range Results: Scan lengths of abdomen/pelvis CT diagnosis of each hospital were different. Also effective dose was increased with increasing the scan length. Generally increasing the distance above diaphragm caused increase of effective dose of male and female, but increasing the distance below pubic symphysis caused increase of effective dose of male. Conclusion: We estimated the patient dose according to scan length of each hospital in abdomen/pelvis CT diagnosis. Effective dose was increased by increasing the scan length because dose of organs with high tissue weighting factor such as lung, breast, testis were increased. Scan length is important factor on patient dose in CT diagnosis. If radiologic technologist interested in patient dose, decreasing the unnecessary scan length will decrease the risk of patients from radiation. This research was supported by a grant of the Korea Health Technology R&D Project through the Korea Health Industry Development Institute (KHIDI), funded by the Ministry of Health & Welfare, Republic of Korea (grant number: HI13C0004).

60 APPLIED LIFE SCIENCES↗

Self-focusing of profiled ultrashort-wavelength laser beams in air

We report on the results of laboratory experiments of filamentation of sharply focused gigawatt femtosecond laser radiation passed through various aperture diaphragms in air. For the multiple filamentation regime, the dependences of the length and spatial structure of the filamentation region on the initial beam profile are established. It is found that light beam profiling by a diaphragm leads in some cases to a displacement of the filamentation region and to repeated self-focusing of radiation behind the linear focal waist. In the beam of the same power in the absence of a diaphragm and in the regime of the formation of a single filament, this effect terminates in front of the geometrical focus. The experimental results are illustrated by numerical simulation data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design of a mercury Propellant Storage and Distribution assembly

A study has been conducted of a Propellant Storage and Distribution (PSD) assembly for a solar electric propulsion (SEP) thrust subsystem. As a result of the trade-off study an elastomeric diaphragm propellant tank with nitrogen blowdown pressurization was the method selected for propellant expulsion. This study included the following propellant management devices: surface tension, metallic bellows, and metallic and elastomeric diaphragms. Pressurant supply concepts investigated were blowdown, externally pressure regulated, vaporizing Freon 113, and heated CO2/Zeolite. The configuration selected consists of a single propellant tank, a single main propellant latching-solenoid valve, and individual thruster latching-solenoid valves. Stainless steel was the selected tankage material and AF-E-332 was the selected diaphragm material. The PSD design characteristics and interfaces are summarized.

Holcomb, L. B.↗

A finite-difference solution for unsteady wave interactions with an application to the expansion tube

An analytical study of the unsteady wave interaction of a shock wave overtaking a previously initiated shock tube flow has been conducted for a real gas by solving a finite-difference representation of the one-dimensional Navier-Stokes equations. This analysis has been used to determine the effect on the available test time of opening the secondary diaphragm in the expansion-tube operating cycle prior to the arrival of the incident shock wave. Special emphasis is placed on determining expansion-tube test-time limitations resulting from a nonuniform entropy distribution occurring during the early test-gas flow due to the varying Mach number of the incident shock wave as it traverses the expansion fan caused by the preopening process. Time distributions of velocity, temperature, pressure, and entropy at various distances from the diaphragm are presented as a function of the time required to open the diaphragm.

Weilmuenster, K. J.↗

Development of an annular arc accelerator shock tube driver

An annular arc accelerator (ANAA) shock tube driver has been developed that deposits the energy of an arc discharge into a flowing gas, which then expands and cools without any delay for the opening of a diaphragm. A simplified one-dimensional flow analysis of the ANAA shock tube has been performed, which indicates that shock velocities greater than 40 km/sec may be obtained using a 300-kJ capacitor bank. The ANAA driver consists of a high-pressure driver, an expansion section, and an electrode section. In operation, the cold gas driver is pressurized until the diaphragm bursts, sending a pressure front down the expansion tube to the arc section. When the accelerated flow arrives at the electrode section, a 100-capacitor, 300-kJ capacitor bank is discharged either by breaking an insulating diaphragm between the electrodes or by the triggering of a series of external switches. Shock velocities of 28 km/sec have been obtained, and modifications are described that are expected to improve performance.

Leibowitz, L. P.↗

Development of a high temperature capacitive pressure transducer

High temperature pressure transducers capable of continuous operation while exposed to 650 C were developed and evaluated over a full-scale differential pressure range of + or - 69 kPa. The design of the pressure transducers was based on the use of a diaphragm to respond to pressure, variable capacitive elements arranged to operate as a differential capacitor to measure diaphragm response and on the use of fused silica for the diaphragm and its supporting assembly. The uncertainty associated with measuring + or - 69 kPa pressures between 20C and 650C was less than + or - 6%.

Egger, R. L.↗

Free-piston regenerative hot gas hydraulic engine

A displacer piston which is driven pneumatically by a high-pressure or low-pressure gas is included in a free-piston regenerative hydraulic engine. Actuation of the displacer piston circulates the working fluid through a heater, a regenerator and a cooler. The present invention includes an inertial mass such as a piston or a hydraulic fluid column to effectively store and supply energy during portions of the cycle. Power is transmitted from the working fluid to a hydraulic fluid across a diaphragm or lightweight piston to achieve a hydraulic power out-put. The displacer piston of the present invention may be driven pneumatically, hydraulically or electromagnetically. In addition, the displacer piston and the inertial mass of the present invention may be positioned on the same side of the diaphragm member or may be separated by the diaphragm member.

Beremand, D. G.↗

Emergency relief venting of the infrared telescope liquid helium dewar, second edition

An updated analysis is made of the emergency relief venting of the liquid helium dewar of the Spacelab 2 Infrared Telescope experiment in the event of a massive failure of the dewar guard vacuum. Such a failure, resulting from a major accident, could cause rapid heating and pressurization of the liquid helium in the dewar and lead to relief venting through the emergency relief system. The heat input from an accident is estimated for various fluid conditions in the dewar and the relief process considered as it takes place through one or both of the emergency relief paths. It was previously assumed that the burst diaphragms in the dewar relief paths would rupture at a pressure of 65 psi differential or 4.4 atmospheres. In fact, it has proved necessary to use burst diaphragms in the dewar which rupture at 115 psid or 7.8 atmospheres. An analysis of this case was carried out and shows that when the high pressure diaphragm rupture occurs, the dewar pressure falls within 8 s to below the 4.4 atmospheres for which the original analysis was performed, and thereafter it remains below that level.

Urban, E. W.↗

Comet flyby sample return experiment

Dust from several comets can be returned to earth with minimum propulsion effort after a high-speed encounter. The collection concept involves the capture of individual dust particles by condensation in a cell after vaporization by a thin diaphragm. This collection concept has been validated in laboratory tests. To compensate for the slower laboratory velocities in a two-stage light-gas gun, higher-density metals (Zn and Cd) have been used for particles and diaphragms to simulate hypervelocity vaporization. Teflon has proved to be a suitable material for the collection cell; more than 50 percent of the vaporized projectile material has been recovered by chemical etching from such cells. Hypervelocity-impact parameters (such as diaphragm-to-projectile ratio, hole size, and plume angles) determined by tests permit the modification of existing analytical models. These new findings are necessary for flyby cometary experiments.

Tsou, P.↗

Astrometric plates obtained at the primary focus of large aperture reflectors

Coma, astigmatism, and great differences in stellar magnitudes between photographed object and reference stars constitute the main sources of errors in measuring positional plates. These three sources of error can easily be eliminated by the method used at the Klet Observatory for obtaining precise observations of faint objects. The astrometric plates are taken by the method of two diaphragms. The first diaphragm, with a small central aperture; is located in front of the photographic plate. The second diaphragm is situated in front of the mirror. By a very short (of the order of tens of seconds) exposure a sufficient number of reference stars can be obtained throughout the entire plate. The stars are very well defined to the very edge of the plate and are easy to measure. Moreover, this method makes it possible to use plates of larger dimensions than usual so that it is always possible to find the necessary reference stars.

Markos, A.↗

Protecting a Ball-Bearing-Deflection Monitor

Deflectometer probe monitors deflection of ball-bearing race in liquid oxygen with aid of small window or diaphragm. Diaphragm or window isolates optical deflectometer from liquid oxygen or other fluid in ball bearing. At high pressures, diaphragm integral part of housing preferable to window, since there would be no leakage.

Kuhr, George A.↗

Interferometers adaptations to lidars

To perform daytime measurements of the density and temperature by Rayleigh lidar, it is necessary to select the wavelength with a very narrow spectral system. This filter is composed by an interference filter and a Fabry Perot etalon. The Fabry Perot etalon is the more performent compound, and it is necessary to build a specific optic around it. The image of the entrance pupil or the field diaphragm is at the infinite and the other diaphragm is on the etalon. The optical quality of the optical system is linked to the spectral resolution of the system to optimize the reduction of the field of view. The resolution is given by the formula: R = 8(xD/Fd)exp 2 where R = lambda/delta(lambda), x = diameter of the field diaphragm, D = diameter of the reception mirror, F = focal length of the telescope, and d = useful diameter of the etalon. In the Doppler Rayleigh lidars, the PF interferometer is the main part of the experiment and the exact spectral adaptation is the most critical problem. In the spectral adaptation of interferometers, the transmittance of the system will be acceptable if the etalon is exactly adjusted to the wavelength of the laser. It is necessary to work with a monomode laser, and adjust the shift to the bandpass of the interferometer. We are working with an interferometer built with molecular optical contact. This interferometer is put in a special pressure closed chamber.

Porteneuve, J.↗