Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DETECTOR PHYSICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Novel 4x4 SiPM array readout with integrated preamplification stage, optimized for the PWO detectors of the EIC EEEMCal

Here we are reporting on a new readout circuit developed for the lead tungstate (PbWO4) scintillation detectors for the Electron Ion Collider (EIC) Electron Endcap Electromagnetic Calorimeter EEEMCal. The high magnetic field region precludes the use of photomultiplier tubes while the detector requirements specify good spectral resolution performance and fast pulse integration over a large dynamic range. We selected a silicon photomultiplier (SiPM) from Hamamatsu and produced a matrix of 4 x 4 sensors to cover the 20 mm x 20 mm scintillator coupling surface. Signal acquisition and amplification electronics boards were designed and integrated with the sensor board to produce a compact high performance readout package. A prototype detector was built and tested at Jefferson Lab with encouraging resolution and timing performance results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A free-standing wire scattering technique to monitor calibration variations of the DIII-D density profile reflectometer

Real-time phase calibration of the ITER profile reflectometer is essential due to the long plasma duration and expected waveguide path length changes during a discharge. Progress has been recently made in addressing this issue by employing a phase calibration technique on DIII-D that monitors calibration variations that occur during each plasma discharge. By installing a thin free-standing metallic wire (1 mm diameter) near the end of the overmoded waveguide transmission system (oriented perpendicular to the waveguide axis), the round-trip phase shift from the wire is detected simultaneously with the plasma phase shifts. Variations in the reflectometer round trip path length (-26 m) are then calculated after each DIII-D plasma discharge, allowing the calibration phase to be accurately monitored and updated. The round-trip reflectometer path length is observed to vary by -3 mm (root mean square value) during a typical DIII-D discharge. Using the variations in calibration phase, the density profile measurement accuracy can be improved. Since the wire retro-reflected power is -0.01 of the plasma signal, minimal effect is observed on the reflected signal from the plasma. Importantly, through a suitable choice in wire diameter, the calibration signal can be made approximately independent of the V-band reflectometer launch polarization. Furthermore, this is particularly important on DIII-D since orthogonal X- and O-mode polarized beams are coupled into the same transmission waveguide and launch antenna.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Search for New Physics through a Long-Lived Di-Muon Resonance in the NuMI Beam with the ICARUS Detector

Many of the unexplained phenomena in particle physics and cosmology today, such as the microphysical nature of dark matter, the strong CP problem, and the origin of the neutrino masses, can be resolved by the existence of a light (~GeV), weakly-coupled hidden sector of new physics. Such hidden sectors often predict the existence of “long-lived” particles (LLPs) that travel a far distance from production before decaying into Standard Model particles. Neutrino oscillation experiments, which combine intense particle beams with precise imaging detectors, are well equipped to probe LLP models with new sensitivity. This thesis details a search for a long-lived particle decaying to two muons with the ICARUS liquid argon time projection chamber (LArTPC) neutrino detector in the Short-Baseline Neutrino program at Fermilab. The calibration of the ICARUS time projection chamber (TPC) which enables the search is also presented. Notably, the calibration measures an angular dependence in electron-ion recombination in argon, a novel effect in the detector physics of LArTPCs. The search is performed using data taken with the Neutrinos at the Main Injector (NuMI) beam, with an exposure of 2.41e20 protons on target. No significant excess over background is observed, and we set world-leading limits on two new physics models that predict this process: the Higgs portal scalar and a heavy axion model. We also present the sensitivity in a model-independent way applicable to any new physics model predicting the process K → π + S(→μμ), for a long-lived particle S.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hall B superconducting magnets for the CLAS12 detector at JLAB

Hadron physics has been an essential part of the physics program with the CLAS detector in experimental hall B at Thomas Jefferson National Accelerator Facility (Jefferson Lab). With the 12 GeV upgrade of the CEBAF machine, hadron physics in Hall B will be extended to a new domain of higher mass resonances and the range of higher transferred momentum using up to 11 GeV electron beams and the upgraded CLAS12 detector. In this paper, status of the hall B superconducting magnets for the 12 GeV upgrade is presented.

43 PARTICLE ACCELERATORS↗

Status of Hall B superconducting magnets for the CLAS12 detector at JLab

Hadron physics has been an essential part of the physics program with the CLAS detector in experimental hall B at Thomas Jefferson National Accelerator Facility (Jefferson Lab). With the 12 GeV upgrade of the CEBAF machine, hadron physics in Hall B will be extended to a new domain of higher mass resonances and the range of higher transferred momentum using up to 11 GeV electron beams and the upgraded CLAS12 detector. In this paper, status of the hall B superconducting magnets for the CLAS12 detector is presented.

43 PARTICLE ACCELERATORS↗

High Energy Electromagnetic Particle Transportation on the GPU

We present massively parallel high energy electromagnetic particle transportation through a finely segmented detector on a Graphics Processing Unit (GPU). Simulating events of energetic particle decay in a general-purpose high energy physics (HEP) detector requires intensive computing resources, due to the complexity of the geometry as well as physics processes applied to particles copiously produced by primary collisions and secondary interactions. The recent advent of hardware architectures of many-core or accelerated processors provides the variety of concurrent programming models applicable not only for the high performance parallel computing, but also for the conventional computing intensive application such as the HEP detector simulation. The components of our prototype are a transportation process under a non-uniform magnetic field, geometry navigation with a set of solid shapes and materials, electromagnetic physics processes for electrons and photons, and an interface to a framework that dispatches bundles of tracks in a highly vectorized manner optimizing for spatial locality and throughput. Core algorithms and methods are excerpted from the Geant4 toolkit, and are modified and optimized for the GPU application. Program kernels written in C/C++ are designed to be compatible with CUDA and OpenCL and with the aim to be generic enough for easy porting to future programming models and hardware architectures. To improve throughput by overlapping data transfers with kernel execution, multiple CUDA streams are used. Issues with floating point accuracy, random numbers generation, data structure, kernel divergences and register spills are also considered. Performance evaluation for the relative speedup compared to the corresponding sequential execution on CPU is presented as well.

Canal, P.↗

The DUNE Far Detector Interim Design Report Volume 1: Physics, Technology and Strategies

The DUNE IDR describes the proposed physics program and technical designs of the DUNE Far Detector modules in preparation for the full TDR to be published in 2019. It is intended as an intermediate milestone on the path to a full TDR, justifying the technical choices that flow down from the high-level physics goals through requirements at all levels of the Project. These design choices will enable the DUNE experiment to make the ground-breaking discoveries that will help to answer fundamental physics questions. Volume 1 contains an executive summary that describes the general aims of this document. The remainder of this first volume provides a more detailed description of the DUNE physics program that drives the choice of detector technologies. It also includes concise outlines of two overarching systems that have not yet evolved to consortium structures: computing and calibration. Volumes 2 and 3 of this IDR describe, for the single-phase and dual-phase technologies, respectively, each detector module's subsystems, the technical coordination required for its design, construction, installation, and integration, and its organizational structure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Probing New Physics with Tau Leptons using the CMS Detector

The Standard Model (SM) of particle physics is a thoroughly well-tested theory of all electroweak scale phenomena to date—the most recent test being the discovery of the long-predicted Higgs boson. However, there is much evidence to suggest that it is incomplete. On the formal side, the mass of the Higgs particle itself is perplexingly small, while the largest theoretical energy scale of the SM is 17 orders of magnitude larger, a puzzle known as the hierarchy problem. On the experimental side, among other things, the SM lacks a candidate for dark matter, which is now known to play an indispensable role in astrophysical large scale structure formation. Many theories that address the fundamental puzzles of the SM predict the existence of multiple Higgs bosons, including a very light boson that couples preferentially to third-generation fermions. Observation of this new light boson, either directly produced or in the decay of the recently discovered SM Higgs, would provide an unmistakable sign of new dynamics in nature. The research supported by this award used data collected by the Compact Muon Solenoid (CMS) detector at the Large Hadron Collider (LHC) to explore boosted di-tau signatures of a new light boson as a tool in the quest to understand the shortcomings of the SM. With a proton-proton collision energy of 13 trillion electron-volts (TeV) and peak instantaneous proton luminosity of over 10^34 collisions per square centimeter per second (cm –2 s –1 ), the LHC is the only facility in the world that could enable this line of research. The research sought to address the hierarchy problem and other shortcomings of the SM through a mixture of LHC data analysis, maintenance of the CMS detector to ensure high quality data, and contributions to the Phase 2 upgrade detector for the upcoming High Luminosity phase of the LHC (HL-LHC).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The DUNE Far Detector Interim Design Report Volume 1: Physics, Technology and Strategies

The DUNE IDR describes the proposed physics program and technical designs of the DUNE Far Detector modules in preparation for the full TDR to be published in 2019. It is intended as an intermediate milestone on the path to a full TDR, justifying the technical choices that flow down from the high-level physics goals through requirements at all levels of the Project. These design choices will enable the DUNE experiment to make the ground-breaking discoveries that will help to answer fundamental physics questions. Volume 1 contains an executive summary that describes the general aims of this document. The remainder of this first volume provides a more detailed description of the DUNE physics program that drives the choice of detector technologies. It also includes concise outlines of two overarching systems that have not yet evolved to consortium structures: computing and calibration. Volumes 2 and 3 of this IDR describe, for the single-phase and dual-phase technologies, respectively, each detector module's subsystems, the technical coordination required for its design, construction, installation, and integration, and its organizational structure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies on the response of a water-Cherenkov detector of the Pierre Auger Observatory to atmospheric muons using an RPC hodoscope

Extensive air showers, originating from ultra-high energy cosmic rays, have been successfully measured through the use of arrays of water-Cherenkov detectors (WCDs). Sophisticated analyses exploiting WCD data have made it possible to demonstrate that shower simulations, based on different hadronic-interaction models, cannot reproduce the observed number of muons at the ground. The accurate knowledge of the WCD response to muons is paramount in establishing the exact level of this discrepancy. In this work, we report on a study of the response of a WCD of the Pierre Auger Observatory to atmospheric muons performed with a hodoscope made of resistive plate chambers (RPCs), enabling us to select and reconstruct nearly 600 thousand single muon trajectories with zenith angles ranging from 0$^\circ$ to 55$^\circ$. Comparison of distributions of key observables between the hodoscope data and the predictions of dedicated simulations allows us to demonstrate the accuracy of the latter at a level of 2%. As the WCD calibration is based on its response to atmospheric muons, the hodoscope data are also exploited to show the long-term stability of the procedure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of the underground muon detector of the Pierre Auger Observatory

To obtain direct measurements of the muon content of extensive air showers with energy above 10 16.5 eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10 m 2 -modules, each segmented into 64 scintillators coupled to silicon photomultipliers (SiPMs). Direct access to the shower muon content allows for the study of both of the composition of primary cosmic rays and of high-energy hadronic interactions in the forward direction. As the muon density can vary between tens of muons per m 2 close to the intersection of the shower axis with the ground to much less than one per m 2 when far away, the necessary broad dynamic range is achieved by the simultaneous implementation of two acquisition modes in the read-out electronics: the binary mode, tuned to count single muons, and the ADC mode, suited to measure a high number of them. In this work, we present the end-to-end calibration of the muon detector modules: first, the SiPMs are calibrated by means of the binary channel, and then, the ADC channel is calibrated using atmospheric muons, detected in parallel to the shower data acquisition. The laboratory and field measurements performed to develop the implementation of the full calibration chain of both binary and ADC channels are presented and discussed. The calibration procedure is reliable to work with the high amount of channels in the UMD, which will be operated continuously, in changing environmental conditions, for several years.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Introducing a Markov chain-based time calibration procedure for multi-channel particle detectors: application to the SuperFGD and ToF detectors of the T2K experiment

Inter-channel mis-synchronisation can be a limiting factor to the time resolution of high performance timing detectors with multiple readout channels and independent electronics units. In these systems, time calibration methods employed must be able to efficiently correct for minimal mis-synchronisation between channels and achieve the best detector performance. We present an iterative time calibration method based on Markov Chains, suitable for detector systems with multiple readout channels. Starting from correlated hit pairs alone, and without requiring an external reference time measurement, the method solves for fixed per-channel offsets, with precision limited only by the intrinsic single-channel resolution. A mathematical proof that the method is able to find the correct time offsets to be assigned to each detector channel in order to achieve inter-channel synchronisation is given, and it is shown that the number of iterations to reach convergence within the desired precision is controllable with a single parameter. Numerical studies are used to confirm unbiased recovery of true offsets. Finally, the application of the calibration method to the Super Fine-Grained Detector (SuperFGD) and the Time of Flight (TOF) detector at the upgraded T2K near detector (ND280) shows good improvement in overall timing resolution, demonstrating the effectiveness in a real-world scenario and scalability.

calibration and fitting methods↗

Differentiable Simulation of a Liquid Argon Time Projection Chamber

Liquid argon time projection chambers (LArTPCs) are widely used in particle detection for their tracking and calorimetric capabilities. The particle physics community actively builds and improves high-quality simulators for such detectors in order to develop physics analyses in a realistic setting. The ability of these simulators to mimic real, measured data is limited by the modeling of the physical detectors used for data collection. This modeling can be improved by performing dedicated calibration measurements. Conventional approaches calibrate individual detector parameters or processes one at a time. However, the impact of detector processes is entangled, making this a poor description of the underlying physics. We introduce a differentiable simulator that enables a gradient-based optimization, allowing for the first time a simultaneous calibration of all detector parameters. We describe the procedure of making a differentiable simulator, highlighting the challenges of retaining the physics quality of the standard, non-differentiable version while providing meaningful gradient information. We further discuss the advantages and drawbacks of using our differentiable simulator for calibration. Finally, we provide a starting point for extensions to our approach, including applications of the differentiable simulator to physics analysis pipelines.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Kiloton-scale xenon detectors for neutrinoless double beta decay and other new physics searches

We report that large detectors employing xenon are a leading technology in existing and planned searches for new physics, including searches for neutrinoless double beta decay (0νββ) and dark matter. While upcoming detectors will employ target masses of a ton or more, further extending gas- or liquid-phase Xe detectors to the kton scale would enable extremely sensitive next-generation searches for rare phenomena. The key challenge to extending this technology to detectors well beyond the ton scale is the acquisition of the Xe itself. We describe the motivation for extending Xe time-projection chambers to the kton scale and possible avenues for Xe acquisition that avoid existing supply chains. If acquisition of Xe in the required quantities is successful, kton-scale detectors of this type could enable a new generation of experiments, including searches for 0νββ at half-life sensitivities as long as 10 30 yr.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Future Physics Prospects with the CMS Detector at the High-Luminosity LHC

The High-Luminosity Large Hadron Collider is expected to deliver up to 3000 fb ^{-1} − 1 of proton-proton collisions at 14 TeV center-of-mass energy. We present prospects for selected heavy-ion, Standard Model and Higgs sector measurements with the CMS detector at the HL-LHC, and discuss potential sensitivity to several beyond-Standard Model new physics scenarios.

Henderson, Conor↗

Characterizing the radiation response of Cherenkov glass detectors with isotopic sources

Abstract Cherenkov detectors are widely used for particle identification and threshold detectors in high-energy physics. Glass Cherenkov detectors that are sensitive to beta emissions originating from neutron activation have been demonstrated recently as a potential replacement for activation foils. In this work, we set the groundwork to evaluate large Cherenkov glass detectors for sensitivity to MeV photons through first understanding the measured response of small Cherenkov glass detectors to isotopic gamma-ray sources. Counting and pulse height measurements are acquired with reflected glass Cherenkov detectors read out with a photomultiplier tube. Simulation was used to inform our understanding of the measured results. This simulation included radioactive source decay, radiation interaction, Cherenkov light generation, optical ray tracing, and photoelectron production. Implications for the use of Cherenkov glass detectors to measure low energy gammaray response are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Physics Potential of a Future Large n Detector in Korea

The demand for underground labs for neutrino and rare event search experiments has been increasing over the last few decades. Yemilab, constructed in October 2022, is the first deep (1~km) underground lab dedicated to science in Korea, where a large cylindrical cavern (D: 20~m, H: 20~m) was excavated in addition to the main caverns and halls. The large cavern could be utilized for a low background neutrino experiment by a liquid scintillator-based detector (LSC) where a 2.26 kiloton LS target would be filled.It's timely to have such a large but ultra-pure LS detector after the shutdown of the Borexino experiment so that solar neutrinos can be measured much more precisely. Interesting BSM physics searches can be also pursued with this detector when it's combined with an electron linac, a proton cyclotron (IsoDAR source), or a radioactive source. This talk discusses the concept of a candidate detector and the physics potential of a large liquid scintillator detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗