Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Determination of Scopolamine in Human Saliva Using Solid Phase Extraction and LC/MS/MS

Purpose: Scopolamine is the preferred treatment for motion sickness during space flight because of its quick onset of action, short half-life and favorable side-effect profile. The dose administered depends on the mode of administration and usually ranges between 0.1 and 0.8 mg. Such small doses make it difficult to detect concentrations of scopolamine in biological fluids by using conventional HPLC methods. To measure scopolamine in saliva and thereby to evaluate the pharmacokinetics of scopolamine, we developed an LC/MS/MS method using off-line solid phase extraction. Method: Samples (0.5mL) were loaded onto Waters Oasis HLB co-polymer cartridges (10 mg, 1 mL) and eluted with 0.5 mL methanol without evaporation and reconstitution. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 4 minutes. The mobile phase for separation was 90:10 (v/v) methanol: ammonium acetate (2 mM) in water, pH 5.0 +/- 0.1. Concentrations of scopolamine were determined using a Micromass Quattro Micro(TM) mass spectrometer with electrospray ionization (ESI). ESI mass spectra were acquired in positive ion mode with multiple reaction monitoring for the determination of scopolamine m/z = 304.2 yields 138.1 and internal standard (IS) hyoscyamine m/z = 290.2 yields 124.1. Results: The method is rapid, reproducible, specific and has the following parameters: scopolamine and the IS are eluted at 1.7 and 3.2 min respectively. The linear range is 50-5000 pg/mL for scopolamine in saliva with correlation coefficients > 0.99 with a CV < 0.5 %. The intra-day and inter-day CVs are < 15 % for quality control samples with concentrations of 75, 300, 750 and 3000 pg/mL of scopolamine in human saliva. Conclusion: Solid phase extraction allows more rapid sample preparation and greater precision than liquid extraction. Furthermore, we increased the sensitivity and specificity by adjusting the LC mobile phase and using an MS/MS detector.

Wang, Zuwei↗

A Modified LC/MS/MS Method with Enhanced Sensitivity for the Determination of Scopolamine in Human Plasma

Intranasal scopolamine is a choice drug for the treatment of motion sickness during space flight because of its quick onset of action, short half-life and favorable sideeffects profile. The dose administered usually ranges between 0.1 and 0.4 mg. Such small doses make it difficult to detect concentrations of scopolamine in biological fluids using existing sensitive LC/MS/MS method, especially when the biological sample volumes are limited. To measure scopolamine in human plasma to facilitate pharmacokinetic evaluation of the drug, we developed a sensitive LC/MS/MS method using 96 well micro elution plates for solid phase extraction (SPE) of scopolamine in human plasma. Human plasma (100-250 micro L) were loaded onto Waters Oasis HLB 96 well micro elution plate and eluted with 50 L of organic solvent without evaporation and reconstitution. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 3 minutes. The mobile phase for separation was 80:20 (v/v) methanol: ammonium acetate (30 mM) in water. Concentrations of scopolamine were determined using a Micromass Quattro Micro(TM) mass spectrometer with electrospray ionization (ESI). ESI mass spectra were acquired in positive ion mode with multiple reaction monitoring for the determination of scopolamine m/z = 304.2 right arrow 138.1 and internal standard hyoscyamine m/z = 290.2 right arrow 124.1. The method is rapid, reproducible, specific and has the following parameters: scopolamine and the IS are eluted at about 1.1 and 1.7 min respectively. The linear range is 25-10000 pg/mL for scopolamine in human plasma with correlation coefficients greater than 0.99 and CV less than 0.5%. The intra-day and inter-day CVs are less than 15% for quality control samples with concentrations of 75,300, and 750 pg/mL of scopolamine in human plasma. SPE using 96 well micro elution plates allows rapid sample preparation and enhanced sensitivity for the LC/MS/MS determination of scopolamine in a small volume of biological samples. The new method is also cost effective since it uses a small volume of organic solvents compared to the methods using SPE cartridges or regular 96 well SPE plates. This method can be successfully used for bioavailability and pharmacokinetic evaluations of scopolamine, especially when volumes of biological samples are limited. Further investigation to use automated SPE system with 96 well micro elution plates is planned.

Wang, Zuwei↗

Improved atmospheric particle analyzer

Nephelometer measures aerosol particles in wide concentration and size distribution ranges. It measures the light scattered from the aerosol particles at a controlled sampling rate to ensure laminar flow through the sample tube, and thereby eliminate the need for sheath air.

Source record↗

Apollo 9 thermal-control-coating degradation

Analytical studies, ground-test data, and flight data before 1967 indicated that degradation of Apollo thermal-control coatings could be expected, possibly to an extent requiring spacecraft design changes to accomplish the worst-case lunar-landing mission. On the Apollo 9 mission, specimens of Apollo thermal-control coatings were retrieved by the astronauts during the extravehicular activity. These specimens were the first to be returned to earth from space unaffected by entry conditions. Subsequent measurements of the thermophysical properties (solar absorptance and hemispherical emittance) of the thermal-control-sample coatings revealed degradation levels well within the design capability of the Apollo spacecraft.

Smith, J. A.↗

Effects of Apollo 12 lunar material on lipid levels of tobacco tissue and slash pine cultures

Investigations of the lipid components of pine tissues (Pinus elloitii) are discussed, emphasizing fatty acids and steroids. The response by slash pine tissue cultures to growth in contact with Apollo lunar soil, earth basalt, and Iowa soil is studied. Tissue cultures of tobacco grown for 12 weeks in contact with lunar material from Apollo 12 flight contained 21 to 35 percent more total pigment than control tissues. No differences were noted in the fresh or dry weight of the experimental and control samples.

Weete, J. D.↗

Evaluation and study of advanced optical contamination, deposition, measurement, and removal techniques

A program is described to design, fabricate and install an experimental work chamber assembly (WCA) to provide a wide range of experimental capability. The WCA incorporates several techniques for studying the kinetics of contaminant films and their effect on optical surfaces. It incorporates the capability for depositing both optical and contaminant films on temperature-controlled samples, and for in-situ measurements of the vacuum ultraviolet reflectance. Ellipsometer optics are mounted on the chamber for film thickness determinations, and other features include access ports for radiation sources and instrumentation. Several supporting studies were conducted to define specific chamber requirements, to determine the sensitivity of the measurement techniques to be incorporated in the chamber, and to establish procedures for handling samples prior to their installation in the chamber. A bibliography and literature survey of contamination-related articles is included.

Linford, R. M. F.↗

Electron radiation effects on time-dependent dielectric breakdown in SiO2 films

An experiment testing the effect of ionizing radiation on breakdown characteristics of SiO2 films is presented. Silicon wafers were oxidized and metallized, and a capacitor array was etched into a control sample while the rest were first irradiated with 1 MeV electrons and then etched. Time-dependent dielectric tests were made on all the capacitors, and the average characteristics of 96 capacitors are illustrated graphically. The curves are consistent with the model of holes trapped in the SiO2 film during irradiation leading to a retarding field for positive ion emission and drift toward the interface. It is shown how an externally applied field is reduced by the trapped charge, and that changes in the dielectric breakdown properties of the SiO2 film after irradiation depend on the positive trapped charge near the metal interface.

Li, S. P.↗

Effects of multifunctional crosslinking agents on the thermomechanical properties of polyimide films

The potential of high temperature resistant polymers such as polyimides (PI) and polyphenylquinoxalines (PPQ) as matrix resins in fiber-reinforced composites has not been fully realized to date. One of the problems associated with these resins is that they exhibit creep, or thermoplastic yielding under load at temperatures approaching 316 C (600 F). The purpose of this investigation was to further reduce thermoplastic behavior of polyimide resins by substituting a controlled amount of the diamine monomer with crosslinking agents having a higher amine functionality. The knowledge gained from a study of the thermomechanical properties of the crosslinked resins would then be used in the fabrication of fiber-reinforced polyimide composites. This report describes the synthesis and characterization of three new polyfunctional amines. Polyimide films containing varying amounts of the cross-linking agents were prepared, and their properties compared with those of control samples prepared with difunctional amines. The effect of crosslink density on isothermal weight loss, polymer softening, and glass transition temperatures is discussed.

Delvigs, P.↗

A system for the study of molecular contamination

An experimental vacuum chambers was designed and fabricated to provide a wide range of experimental capability. This work chamber assembly (WCA) was conceived to establish the proof-of-principle of various techniques for studying the kinetics of contaminants and their effects. It incorporates the capability for depositing both optical and contaminant films on temperature-controlled samples, and for in-situ measurements of the vacuum ultraviolet reflectance. Ellipsometer optics are mounted on the chamber for film thickness determinations, and other features include access ports for radiation sources and instrumentation.

Dillow, C. F.↗

Photoluminescence of ion-implanted GaN

Thirty-five elements were implanted in GaN. Their photoluminescence spectra were measured and compared to those of an unimplanted control sample. Most impurities emit a peak at about 2.15 eV. Mg, Zn, Cd, Ca, As, Hg, and Ag have more characteristic emissions. Zn provides the most efficient recombination center. A set of midgap states is generated during the damage-annealing treatment.

Pankove, J. I.↗

Data processing for water monitoring system

Water monitoring data acquisition system is structured about central computer that controls sampling and sensor operation, and analyzes and displays data in real time. Unit is essentially separated into two systems: computer system, and hard wire backup system which may function separately or with computer.

Monford, L.↗

Cosmic ray effects on the eyes of rats flown on Cosmos no. 782, Experiment K-007

A study was undertaken to determine if, and to what extent, pathological damage results from high-energy particles (HZE) transversing the eye. Light flashes experienced by space travellers indicate that HZE do indeed pass through and activate the retina, but whether actual biological damage occurs has not been investigated thoroughly. Thus, autopsies were performed on the eyes of rats which has been flown in Cosmos 782 satellite for 19.5 days. Comparisons with a control sample subjected to 1000 rads of Ar and Ne radiation show that pathological damage, when it occurs, affects the nucleus of the retina; simple light flashes are not thought to indicate a pathology, and result from activation of (but not damage to) the retina's outer segments.

Philpott, D. E.↗

Continuous Czochralski growth: Silicon sheet growth development of the large area silicon sheet task of the Low Cost Silicon Solar Array project

The primary objective of this contract is to develop equipment and methods for the economic production of single crystal ingot material by the continuous Czochralski (CZ) process. Continuous CZ is defined for the purpose of this work as the growth of at least 100 kilograms of ingot from only one melt container. During the reporting period (October, 1977 - September, 1978), a modified grower was made fully functional and several recharge runs were performed. The largest run lasted 44 hours and over 42 kg of ingot was produced. Little, if any, degradation in efficiency was observed as a result of pulling multiple crystals from one crucible. Solar efficiencies observed were between 9.3 and 10.4% AMO (13.0 and 14.6% AMI) compared to 10.5% (14.7% AMI) for optimum CZ material control samples. Using the SAMICS/IPEG format, economic analysis of continuous CZ suggests that 1986 DoE cost goals can only be met by the growth of large diameter, large mass crystals.

Source record↗

Diode step stress program, JANTX1N5614

The reliability of switching diode JANTX1N5614 was tested. The effect of power/temperature step stress on the diode was determined. Control sample units were maintained for verification of the electrical parametric testing. Results are reported.

Source record↗

Transistor step stress program for JANTX2N4150

Reliability analysis of the transistor JANTX2N4150 manufactured by General Semiconductor and Transitron is reported. The discrete devices were subjected to power and temperature step stress tests and then to electrical tests after completing the power/temperature step stress point. Control sample units were maintained for verification of the electrical parametric testing. Results are presented.

Source record↗

Coatings in space environment

The behavior in space environment of evaporated Al uncoated and coated with reactively deposited silicon oxide (SiOx), electron beam evaporated SiO2 and Al2O3, and Al and Ag coated with double layers of Al2O3 + SiOx is compared with metallized Teflon and Kapton, anodized Al (Alzak), and white paints. Flight data from three calorimetric experiments and one reflectometer flown in different orbital environments are compared with laboratory test data. The results demonstrate that evaporated thin films are extremely versatile and stable coatings for space applications. Through the use of control samples studied in different laboratory tests and monitored for up to 12,000 hours of solar exposure in different orbits, a classification of orbital severity and an estimate of laboratory simulation accuracy is obtained.

Triolo, J. J.↗

The influence of varied gravito-inertial fields on the cardiac response of orb-weaving spiders

The Gz transfer function was described for the orb weaving spider A. sericatus. The functional relationship between the heartrate and the intensity of G is linear in the form of: Y = a Log Gz-1 +k. The heartrate in unrestrained animals was recorded by a laser plethysmograph developed specifically for this purpose. Following a control, sample heartrate were taken postrotation between 1.001 and 1.5 Gz in 6 steps. The underlying distribution of heartrates does not appear significantly different from a Gaussian distribution. A method of varnishing the legs of the spider was developed. This was done in order to compromise the lyriform organs, especially those located on the patellae. The lyriform organ is hypothesized to serve the receptor role in the transduction of gravity related stimuli. In preliminary animals the Gz function, post varnishing of the patellae, appears to be changed in the direction of poorer discrimination. We also observed that the resting heartrate following the varnish procedure is substantially increased.

Finck, A.↗

Submillisecond Optical Knife-Edge Testing

Fast computer-controlled sampling of optical knife-edge response (KER) signal increases accuracy of optical system aberration measurement. Submicrosecond-response detectors in optical focal plane convert optical signals to electrical signals converted to digital data, sampled and feed into computer for storage and subsequent analysis. Optical data are virtually free of effects of index-of-refraction gradients.

Thurlow, P.↗