Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Contamination Control Engineering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Surface Processes Control the Fate of Reactive Oxidants Generated by Electrochemical Activation of Hydrogen Peroxide on Stainless-Steel Electrodes

Low-cost stainless-steel electrodes can activate hydrogen peroxide (H 2 O 2 ) by converting it into a hydroxyl radical ( • OH) and other reactive oxidants. At an applied potential of +0.020 V, the stainless-steel electrode produced • OH with a yield that was over an order of magnitude higher than that reported for other systems that employ iron oxides as catalysts under circumneutral pH conditions. Decreasing the applied potential at pH 8 and 9 enhanced the rate of H 2 O 2 loss by shifting the process to a reaction mechanism that resulted in the formation of an Fe(IV) species. Significant metal leaching was only observed under acidic pH conditions (i.e., at pH <6), with the release of dissolved Fe and Cr occurring as the thickness of the passivation layer decreased. Despite the relatively high yield of • OH production under circumneutral pH conditions, most of the oxidants were scavenged by the electrode surface when contaminant concentrations comparable to those expected in drinking water sources were tested. The stainless-steel electrode efficiently removed trace organic contaminants from an authentic surface water sample without contaminating the water with Fe and Cr. With further development, stainless-steel electrodes could provide a cost-effective alternative to other H 2 O 2 activation processes, such as those by ultraviolet light.

42 ENGINEERING↗

A compact ultra-clean system for deploying radioactive sources inside the KamLAND detector

We describe a compact, ultra-clean device used to deploy radioactive sources along the vertical axis of the KamLAND liquid-scintillator neutrino detector for purposes of calibration. The device worked by paying out and reeling in precise lengths of a hanging, small-gauge wire rope (cable); an assortment of interchangeable radioactive sources could be attached to a weight at the end of the cable. All components exposed to the radiopure liquid scintillator were made of chemically compatible UHV-cleaned materials, primarily stainless steel, in order to avoid contaminating or degrading the scintillator. To prevent radon intrusion, the apparatus was enclosed in a hermetically sealed housing inside a glove box, and both volumes were regularly flushed with purified nitrogen gas. Finally, an infrared camera attached to the side of the housing permitted real-time visual monitoring of the cable’s motion, and the system was controlled via a graphical user interface.

42 ENGINEERING↗

The diversity of aluminum-based drinking water treatment residuals for use in environmental remediation

Drinking water treatment residuals (DWTRs) are complex mixtures of organic and inorganic phases generally disposed of as waste materials. However, their strong sorptive properties could be further exploited to immobilize contaminants. To characterize these materials, we applied a range of analytical techniques to a set of aluminum-based DWTRs. Here we determined surface areas, elemental compositions using CHNS analysis and X-ray fluorescence (XRF), performed thermogravimetric analyses paired with mass spectrometry (TGA-MS), and used synchrotron-based methods: X-ray diffraction (XRD) and X-ray absorption spectroscopy (XAS). Elemental analyses and specific surface area measurements – that vary between 7.23 ± 0.03 and 197.6 ± 0.9 m 2 g –1 – indicate that non-coagulant additives must play an important role in controlling sorption. High resolution powder XRD reveals the presence of only a few crystalline minerals mostly derived from source waters or additives. Fe was detected by XRF in all samples, whereas Mn was present in significant levels in samples with potassium permanganate as additive. The chemical speciation of these elements was characterized by performing spectral decompositions of XAS spectra. The spectral features of Fe are consistent with iron(III) oxides/hydroxides and structural iron in clays. On the other hand, Mn is predominantly present under its reduced form, Mn(II).

54 ENVIRONMENTAL SCIENCES↗

Advanced Test Reactor Safety Basis Update for Gas-Cooled Experiments

The Advanced Test Reactor (ATR) supports neutron irradiation of several types of experiments. One such experiment type is referred to as a gas leadout. Gas leadout experiments actively flow gas through the experiment which allows for active temperature control. It also allows for in-situ data of the experiment. For example, fission gas migration through a fuel sample can be monitored via activity of the sweep gas. Historically, ex-pile equipment and fission product monitors were housed in shielded ATR cubicles. Due to other facility updates, cubicle space is no longer available for gas leadout experiment equipment. To support continued operation of gas leadout experiments, ATR completed a safety basis update that supports a new housing for leadout equipment that may process potentially contaminated gas. In addition to the structure and associated equipment, technical safety requirements regarding handling and storage of experiments needed to be revised to support fueled gas leadout experiments and associated outage configurations. The safety basis update addressed the full lifecycle of these experiments, including experiment movement and interim storage, and credible abnormal events such as failures or leaks in contaminated gas tubing in occupied areas. This paper discusses the completed analyses performed to support the safety basis update associated with gas leadout experiments, including thermal-hydraulic evaluation, probabilistic analysis, and dose consequence analyses.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A High-Fidelity Modeling Tool to Support the Design of Oxy-Combustors for Direct-Fired Supercritical CO2 Cycles

The challenge in the design of oxy-combustors for direct-fired supercritical CO 2 (sCO 2 ) cycles is in addressing disparate performance metrics and objectives. Key design parameters to consider include, among others, injector design for mixing and flame stability, split of recycled CO 2 diluent between injectors and cooling films, target flame temperatures to control noncondensable products, and strategies to inject the diluent CO 2 for film cooling and thermal control. In order to support novel oxy-combustor designs, a high-fidelity yet numerically efficient modeling framework based on the CRUNCH CFD® flow solver is presented, featuring key physics-based submodels relevant in this regime. For computational efficiency in modeling large kinetic sets, a flamelet/progress variable (FPV) based tabulated-chemistry approach is utilized featuring a three-stream extension to allow for the simulation of the CO 2 film cooling stream in addition to the fuel and oxidizer streams. Finite rate chemistry effects are modeled in terms of multiple progress variables for the primary flame as well as for slower-evolving chemical species such as NO x and SO x contaminants. Real fluid effects are modeled using advanced equations of states. The predictive capabilities of this computationally tractable design support tool are demonstrated on a conceptual injector design for an oxy-combustor operating near 30 MPa. Simulations results provide quantitative feedback on the effectiveness of the film cooling as well as the level of contaminants (CO, NO, and N) in the exhaust due to impurities entering from the injectors. These results indicate that this framework would be a useful tool for refining and optimizing the oxy-combustor designs as well as risk mitigation analyses.

Engineering↗

Demethylation or Sorption? The Fate of Methylmercury in the Presence of Manganese Dioxide

Manganese oxide (MnO 2 ) amendments to mercury (Hg)-contaminated sediment have been shown to decrease methylmercury (MeHg) concentrations in sediment porewater. In the absence of solid-phase MeHg measurements, it is unclear whether the decreased porewater concentrations are due to inhibition of methylation, adsorption of the MeHg to the MnO 2 , demethylation of MeHg catalyzed by the MnO 2 , or some combination of these mechanisms. We conducted controlled laboratory experiments to determine whether MeHg losses from solution in the presence of amorphous MnO 2 are due to sorption or demethylation. In this work, we quantified MeHg in the dissolved phase and solid phase and found that no demethylation occurred. We used batch and isotherm experiments to determine MeHg sorption efficiency to MnO 2 in a variety of solutions with varying ionic strength and dissolved organic matter (DOM) concentration. Isotherms over an initial concentration range of 5–500 ng/L of MeHg showed no saturation effects. Increasing ionic strength from 0.012 M to 0.1 M produced relatively minor decreases in MeHg sorption. Increasing DOM concentrations from 0.64 to 16.4 mg C/L yielded substantial decreases in MeHg sorption. Under the experimental conditions, MnO2 is a less efficient MeHg sorbent compared to other sorbent materials, such as Thiol-SAMMS®, activated carbon, and biochar.

42 ENGINEERING↗

Defining a compact dry cooler design to reduce LCOE contribution in a CSP facility

Concentrating solar power (CSP), when coupled with a supercritical carbon dioxide (sCO 2 ) power cycle and sensible heat storage, presents a renewable and clean alternative for utility-scale power generation. However, in order to be competitive in the current and future markets, CSP facilities must limit their levelized cost of electricity (LCOE) by minimizing capital costs and reducing operating costs over the lifetime of the plant. Targeting this goal, this study investigates the LCOE impact of the power cycle pre-cooler. This study considers a compact dry cooler with micro-channel technology on the CO 2 side and formed fin geometry on the air side, using directly-coupled centrifugal fans and a transition duct to improve air distribution across the fins as well as protect the fins from contaminants which may cause blockage, soiling, fouling, and damage. In an effort to better understand the dry cooler impact on LCOE, a sensitivity study was conducted using various combinations of end-to-end approach temperatures, air-side pressure drop values, CO 2 -side pressure drop values, fan types, cooler turndown control schemes, cooler module sizes, and design-point ambient temperatures. Furthemore, off-design cycle performance data was calculated for each dry cooler design using NPSS simulation software; cycle performance data were then input to System Advisor Model (SAM) along with the associated capital costs for LCOE prediction of a 100 MW system over a 30 year plant lifetime. Results of this study show the LCOE is most sensitive to air-side performance, followed by heat transfer effectiveness and capital cost. It was found that a power cycle with a mid- to high-performance dry cooler will produce the most competitive power-production costs. Designing at the extreme ends for approach temperature (or effectiveness), design-point ambient temperature, and compactness (footprint) produce higher LCOE values; mid-range values for these parameters balance performance, operating costs, and associated capital cost to optimize LCOE.

14 SOLAR ENERGY↗

Contamination control and assay results for the Majorana Demonstrator ultra clean components

The Majorana Demonstrator is a neutrinoless double beta decay experiment utilizing enriched Ge-76 detectors in 2 separate modules inside of a common solid shield at the Sanford Underground Research Facility. The Demonstrator has utilized world leading assay sensitivities to develop clean materials and processes for producing ultra-pure copper and plastic components. This experiment is now operating, and initial data provide new insights into the success of cleaning and processing. Post production copper assays after the completion of Module 1 showed an increase in U and Th contamination in finished parts compared to starting bulk material. A revised cleaning method and additional round of surface contamination studies prior to Module 2 construction have provided evidence that more rigorous process control can reduce surface contamination. In conclusion, this article describes the assay results and discuss further studies to take advantage of assay capabilities for the purpose of maintaining ultra clean fabrication and process design.

36 MATERIALS SCIENCE↗

Use of Separator with Regular Granular Filling in Extraction Processes - 12209

The separator with a regular granular filling has been developed to be used for the operations of the removal of carbon-black impurities from the aqueous flow; the intra-cycle regeneration of back-extractants; and the concentrating back-extraction of plutonium in the extraction SNF reprocessing technology. The process conditions for those operations have been experimentally tested using this separator. Thus, the separator for operations of concentrating reextraction of plutonium and regeneration recycling extractant allows to: - derive plutonium from the organic stream into an extremely concentrated form, reducing the amount of liquid radioactive waste (raffinate, decantate) plutonium branches to a minimum; - controlling the processes of concentration of uranium and plutonium, get uranium-plutonium product with required concentration and the amount of metal with required ratio; - eliminate contamination of the emulsion flows; - simplify the purification of uranium from the extract plutonium; - test results showed that when working on a solution 'hydrazine-DTPA' in the separator it is achieved the extraction of plutonium re-extract - 82% TC - at 56-65%. With the transition to the reextraction by solution 'U (IV)-hydrazine', of plutonium into re-extract increases to 95%, technetium - up to 83%; - regenerate the extractant recycling minimizing the amount of liquid radioactive waste generated as a technology used as well as alternative 'salt-free' systems; - it is found that the regeneration of the extractant solution of soda and EDA in the separator at a load of 3.2 m{sup 3} / (m{sup 2}.h) it can be achieved almost complete phase separation. Residual carryover of 0,005-0,006% emulsion is on the verge of analytical detection. - It is shown that in the depth of separation phase a separation of the extractant regeneration of quality superior is more than 5-7 times to the extraction. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Approaches for effective negative pressure isolation space control to minimize airborne transmission of contaminants in residential homes

Controlling airborne transmission of contaminants including respired viruses such as SARS-CoV-2 is necessary to protect occupants living in the same house with a contagious person. The effectiveness of interventions requiring minor efforts that create a negative pressure isolation zone (IZ) for a contagious person has yet to be systematically tested for residential homes. In this study, ASHRAE Standard 170, which offers guidance for negative pressure isolation space control in healthcare facilities, was used in developing practical and attainable recommendations for residential single-family homes. The relative effectiveness of several control strategies was evaluated through experimentally conducting 17 different test cases in a manufactured single-family house laboratory. These cases were designed based on various heating, ventilation and air-conditioning (HVAC) operating scenarios, intervention measures including closing the IZ door and/or sealing over supply and return air grilles in the IZ, and utilization of bathroom exhaust or portable window fans for pressure control. Four out of 17 test cases were identified as having the potential for strong containment with adequate depressurization in the IZ. The most effective IZ depressurization was achieved through continuously operating the exhaust fan in the bathroom attached to the IZ, by installing a portable window fan that extracted air out of the IZ, and a portable room air conditioner with the AC unit exhaust duct installed in one of the IZ windows.

Construction & Building Technology↗

EPA and Idaho National Laboratory create first of its scale

Advancing the science and engineering of decontaminating water distribution systems and safely disposing of high-volumes of contaminated water are high priorities for the EPA. To help address these science gaps, EPA homeland security researchers have developed the first-of-its-scale Water Security Test Bed (WSTB). Water is an important component of everyday life. We rely on safe, clean water for our health and the health of the environment. Protecting this vital resource is critical to living safely and securely. The U.S. Environmental Protection Agency is responsible for working with water utilities to protect water systems from contamination and to clean up systems that become contaminated. Purposeful or inadvertent distribution system contamination can result in large amounts of infrastructure and water that must be cleaned. Water distribution systems contamination can be caused by, for example, natural disasters such as Superstorm Sandy or by individuals hoping to cause harm. The WSTB, constructed at the Department of Energy’s (DOE) Idaho National Laboratory, replicates a section of a typical municipal drinking water system including a piping system with roughly 445 feet of pipe and two fire hydrants laid out in an “L” shape using 40-year-old, eight-inch cement mortar lined, ductile iron pipes, excavated after twenty years of use for water conveyance. Researchers built the WSTB above ground for easy access during experiments, and to facilitate fast leak detection. Over the next several years, EPA and partner researchers will conduct experiments using simulants of various biological, chemical, and radioactive materials that simulate high toxic versions of these agents. At this “full” sized system, researchers will demonstrate approaches to contamination detection, sensor and model testing, infrastructure decontamination, water treatment and cyber testing developed at lab and pilot scale. Researchers are also able to verify if laboratory results that were effective in controlled conditions are as effective in full-scale testing. Having the ability to conduct bench scale studies in a real world setting can help address specific research gaps, and help water researchers understand conditions in which real world drinking water systems operate.

54 ENVIRONMENTAL SCIENCES↗

Probing unintentional Fe impurity incorporation in MOCVD homoepitaxy GaN: Toward GaN vertical power devices

Unintentional impurity incorporation in GaN drift layers represents a challenging issue that can limit their potential performance in vertical power devices. In this paper, we focus on studying the origins of Fe impurity incorporation in metal-organic chemical vapor deposition (MOCVD) grown GaN materials. Acting as a compensator in n-type GaN drift layers, Fe impurities can reduce the electron mobility in GaN and limit the lowest controllable doping level. Two sources, the sample cleaning process and growth susceptor, were identified as the main mechanisms of Fe incorporation in the MOCVD GaN growth process. It was found that solvent cleaning of the wafer can introduce significant Fe contamination at the growth interface, which would slowly be incorporated into the GaN epilayer, thus causing background Fe impurity as high as 10 17 cm -3 level. Moreover, the Fe impurity in the coating material on the susceptor can introduce additional Fe impurity during the growth process. Our studies revealed that the Fe impurity level could be significantly suppressed by more than two orders when an alternative cleaning process was used and the susceptor surface was fully covered by substrates. Characterization of the Fe impurity concentrations was performed via secondary ion mass spectrometry. The trap level (E C - 0.57) eV from deep-level transient spectroscopy that had previously been attributed to Fe confirmed the carrier compensation effect from Fe. Room temperature Hall mobility as high as 1007 cm 2 /V s was achieved on the MOCVD grown low-Fe GaN. Results from this work will provide guidance for achieving high purity GaN toward high performance GaN vertical power devices.

42 ENGINEERING↗

Smart Ventilation Controls for Occupancy and Auxiliary Fan Use Across U.S. Climates

Smart Ventilation has been developed as a way to reduce the energy associated with ventilation by changing when ventilation happens and how much ventilation occurs at any given time. In high performance buildings with low envelope and appliance related loads, ventilation is becoming a bigger part of the total building energy use and needs to be addressed if performance targets are to be met. This work explores the development and performance of smart ventilation controls based on occupancy and auxiliary fan operation that provide annual dwelling unit ventilation equivalence to ASHRAE Standard 62.2-2016. A prototype high performance home compliant with U.S. DOE Building America Zero Energy Ready program requirements was simulated using the REGCAP tool with and without smart controls across 15 U.S. DOE climate zones. Balanced and unbalanced IAQ fans were independently simulated, and all smart controlled fans had airflows double the reference 62.2-2016 airflow. Three idealized occupancy patterns were examined: 1st shift (a typical daily work/school absence), an extended 1st shift with more time spent out of the home evenings and weekends and 3rd shift (night work). The Occupancy controller turns the IAQ fan off during unoccupied periods, and it resumes ventilation upon their return. While unoccupied, contaminants are allowed to accumulate in the space, because occupants are not exposed to these contaminants. When occupants return home, they are exposed to these higher contaminant concentrations, and the controller increases the ventilation rate sufficiently to ensure equivalence with a continuous IAQ fan. Accounting for pollutant emissions that occur during unoccupied periods (as required by ASHRAE 62.2-2016), sharply distinguishes our occupancy controls from past Demand Controlled Ventilation systems. This new accounting method results in equivalent contaminant exposure, as well as lower reductions in average ventilation rates and lower energy savings. Smart controls were demonstrated that saved HVAC energy (i.e., avoided heating/cooling load, as well as fan energy)—averaging between 6 and 46% of ventilation-related energy use depending on the control strategy and occupancy pattern assumptions. The greatest savings were in the combined Auxiliary Fan + Occupancy control. Energy savings increased with climate heating demand and longer unoccupied time periods. The 3rd shift occupancy pattern had better performance, due to the thermal benefit of reducing the ventilation rate during the cold nighttime hours. This same effect provided a cooling energy benefit in hotter locations for the 1st shift. Overall, savings from occupancy-based smart controls were low, because of the recovery period required after occupants return home, during which the airflow is double the 62.2 reference. This recovery is required to maintain equivalence with the ASHRAE standard. Occupancy-based control performance was improved when combined with sensing auxiliary fans and when providing a pre-occupancy flush out of one- or two-hours. Performance was similarly improved if the ASHRAE Standard were to recognize that pollutant emissions are lower during unoccupied periods, iii allowing a lower target ventilation rate during unoccupied periods (not currently in the standard) (see Full vs. Half AEQ in this report). Finally, over-sized unbalanced fans that are cycled on-and-off by a smart controller (or timer) were found to substantially increase annual average air exchange and energy use relative to a continuous unbalanced fan due to the effects of superposition with natural infiltration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Vertical Extraction Process Implemented at the 118-K-1 Burial Ground for Removal of Irradiated Reactor Debris from Silo Structures - 12431

The primary objective of a remediation project is the safe extraction and disposition of diverse waste forms and materials. Remediation of a solid waste burial ground containing reactor hardware and irradiated debris involves handling waste with the potential to expose workers to significantly elevated dose rates. Therefore, a major challenge confronted by any remediation project is developing work processes that facilitate compliant waste management practices while at the same time implementing controls to protect personnel. Traditional burial ground remediation is accomplished using standard excavators to remove materials from trenches and other excavation configurations often times with minimal knowledge of waste that will be encountered at a specific location. In the case of the 118-K-1 burial ground the isotopic activity postulated in historic documents to be contained in vertical cylindrical silos was sufficient to create the potential for a significant radiation hazard to project personnel. Additionally, certain reported waste forms posed an unacceptably high potential to contaminate the surrounding environment and/or workers. Based on process knowledge, waste management requirements, historic document review, and a lack of characterization data it was determined that traditional excavation techniques applied to remediation of vertical silos would expose workers to unacceptable risk. The challenging task for the 118-K-1 burial ground remediation project team then became defining an acceptable replacement technology or modification of an existing technology to complete the silo remediation. Early characterization data provided a good tool for evaluating the location of potential high exposure rate items in the silos. Quantitative characterization was a different case and proved difficult because of the large diameter of the silos and the potential for variable density of attenuating soils and waste forms in the silo. Consequently, the most relevant information supporting job planning and understanding of the conditions was the data obtained from the gross gamma meter that was inserted into each casing to provide a rough estimate of dose rates in the tubes. No added value was realized in attempting to quantify the source term and/or associate the isotopic activity with a particular actual waste form (e.g., sludge). Implementing the WRM system allowed monitoring of worker and boundary exposure rates from a distance, maintaining compliance with ALARA principles. This system also provided the project team early knowledge of items being removed that had high exposure rates associated with them, thus creating an efficient method of acknowledging an issue and arriving at a solution prior to having an upset condition. An electronic dosimeter with telemetry capability replaced the excavator mounted AMP-100 system approximately half way through remediation of the silos. Much higher connectivity efficiency was derived from this configuration. Increasing the data feed efficiency additionally led to less interruption of the remediation effort. Early in system testing process a process handicap on the excavator operator was acknowledged. A loss of depth perception resulted when maneuvering the excavator and bucket using the camera feed to an in-cab monitor. Considerable practice and mock-up testing allowed this handicap to be overcome. The most significant equipment failures involved the cable connection to the camera mounted between the clamshell bucket jaws and the video splitter in the excavator cab. Rotation of the clamshell bucket was identified as the cause of cable connection failures because of the cyclic twisting motion and continuous mechanical jarring of the connection. In-cab vibration was identified as the culprit in causing connection failures of the video splitter. While these failures were repaired, substantial production time was lost. Ultimately, the decision was made to purchase a second cable and higher quality video splitter eliminate the down time. An engineering improvement for future operations would be inserting cable pig tails at more stressed cable connection points to facilitate rapid change out of the cable should that be required. Overall, the system performed better than expected in a safe and efficient manner. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Waste Management 2016 300-296 Soil Remediation Project. Developing Innovative Solutions to Overcome Design Challenges - 16229

The 324 Building is a non-reactor, Hazard Category 2, Nuclear Facility located in the 300 Area of the U.S. Department of Energy (DOE) Hanford Site, located near Richland, Washington. The building is undergoing deactivation, decommissioning, decontamination, and demolition by Washington Closure Hanford (WCH) under the River Corridor Closure Contract. During the Cold War Era, the facility was used for chemical and radionuclide processing associated with nuclear weapons production. Historical records indicate that in October 1986, approximately 516 L of a concentrated liquid waste stream containing cesium-137 and strontium-90 was spilled onto the floor of B-Cell. B-Cell is located in the Radiochemical Engineering Complex (REC) of the 324 Building. It is estimated that this spill contained approximately 1.3 million curies of radioactivity. Some fraction of the spill was recovered; however, an unknown quantity was released into the soil beneath the 324 Building through an undetected breach in the B-Cell floor sump. Unknown quantities of water were used after the spill to wash items contained in B-Cell. When B-Cell was taken out of service, wastes being removed from B-Cell were placed in Grout Containers (GCs) and stabilized using a particulate grout. In the course of grouting activities, grout was spilled on the floor of B-Cell, eventually filling the sump. The primary scope of this project is to design, test, and implement a process capable of removing and isolating contaminated soil below B-Cell. This remediation effort has been divided into two removal zones identified as the primary and secondary removal zones. Based on current assumptions and estimates, the primary phase of this cleanup effort will remove roughly 156.45 m{sup 3} of highly contaminated materials. B-Cell debris, particulate grout, and the floor slab and liner comprise about 21.24 m{sup 3} of the total. The remaining 135.21 m3 will be contaminated soil. All of this material must be disposed of within the existing 324 Facility or packaged for disposal at the Hanford site. The objective of this project is to remove the B-Cell floor and highly contaminated underlying soils from beneath B-Cell using remote equipment to reduce the radiation levels and allow open-air excavation for the remaining contaminated soil. The challenges and subsequent technological solutions encountered from the Conceptual Design phase to the 100% Design Issued For Fabrication/Issued For Construction (IFF/IFC) consisted in part of the following: Design an efficient remote cleanup strategy for highly contaminated Low Level Waste (LLW) given the unknowns. Maintain contamination control down to 18 feet below B-Cell in a highly radioactive environment (12,870 R/Hr Cs-137 and Sr-90). Perform facility upgrades to enable remediation process implementation while maintaining integrity of pre-existing facility structure and license. Designing first-of-a-kind remote equipment for use in high radiation areas. Developing first-of-a-kind operations sequences for remote equipment while minimizing usage of original facility equipment (i.e. cranes, manipulators, etc.). Conducting time-motion studies of operations sequences to maximize efficiency while keeping dose As Low As Reasonably Achievable (ALARA) in a high dose environment. Construction of a full scale mockup to conduct performance testing in a clean environment and train the work force to operate the equipment. Overcoming scope, budget and schedule constraints associated with a fast-track DOE project. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Benefits of digitalizing and employing simulation to increase plant system performance and ensure compliance with technical specifications - 109

The essential services water system in a BWR nuclear power plant was affected by corrosion, soiling and blockages due to ageing. Those episodes affected safety margins hindering the Technical Specifications compliance during periodic system testing. Tecnatom designed, implemented and tested a design modification for the on-line monitoring of this system by integrating it in the existing Digital Control System (DCS). Key system parameters were acquired in real time to be displayed in the Human System Interface, used in performing calculations and stored their historical evolution. The objective was to optimize monitoring and surveillance of the essential service water system. Furthermore, Tecnatom developed an engineering simulator ('What if' simulator) consisting of a hydraulic model of the system. This simulator takes as inputs each heat exchanger performance parameters from the plant DCS, allows the user to change the essential services water system configuration (valves position, UHS level...) and calculates theoretical process values predicting the system real behavior. In a second stage, more system instruments were wired to the DCS for Technical Specifications compliance automatic surveillance regarding opening and closing times of system valves. Operating experience shows important benefits after the digitalization. It enhances on-line information of system operation and automates calculation of load loss factor of each heat exchanger. It eases the evaluation of blockages and soiling in the system allowing optimization of cleaning proceedings. System Surveillance Requirements and Test Requirements reports have been automated optimizing the operation workload. The simulator use enables to identify optimal system configuration increasing safety margins of the system and ensuring Technical Specifications fulfillment. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Radiation Impact of Very Low Level Radioactive Steel Reused in Building Industry with Emphasis on External Exposure Pathway - 12569

Considerable quantities of various materials are accumulated during the decommissioning process of nuclear installations. Some of arising materials are activated or contaminated. However, many of them continue to have an economic value and exist in a form that can be recycled or reused for special purposes. Furthermore much of the material generated during decommissioning process will contain only small amounts of radionuclides. For these materials there exist environmental and economic incentives to maximize the use of the concept of clearance from further regulatory control. This impact analysis is devoted to mentioned incentives. The aim is to conditionally clear maximum amount of the scrap steel and consequently recycle and reuse it in form of reinforcing components in tunnel and bridge building scenarios. Recent calculations relevant for external exposure pathway indicate that concept of conditional clearance represent a feasible option for the management of radioactive materials. Even in chosen specific industrial applications it is possible to justify new, approximately one order of magnitude higher, clearance levels. However analysis of other possible exposure pathways relevant for particular scenario of reuse of conditionally cleared materials has to be performed in order to confirm indications from partially obtained results. Basically, the concept of conditional clearance can bring two basic benefits. Firstly it is saving of considerable funds, which would be otherwise used for treatment, conditioning and disposal of materials at appropriate radioactive waste repository. Moreover materials with intrinsic value (particularly metals) can be recycled and reused in industrial applications instead of investing resources on mining and production process in order to obtain new, 'fresh' materials. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Porous Iron Electrodes Reduce Energy Consumption During Electrocoagulation of a Virus Surrogate: Insights into Performance Enhancements Using Three-Dimensional Neutron Computed Tomography

Electrocoagulation has attracted significant attention as an alternative to conventional chemical coagulation because it is capable of removing a wide range of contaminants and has several potential advantages. In contrast to most electrocoagulation research that has been performed with nonporous electrodes, in this study, we demonstrate energy-efficient iron electrocoagulation using porous electrodes. In batch operation, investigation of the external pore structures through optical microscopy suggested that a low porosity electrode with sparse connection between pores may lead to mechanical failure of the pore network during electrolysis, whereas a high porosity electrode is vulnerable to pore clogging. Electrodes with intermediate porosity, instead, only suffered a moderate surface deposition, leading to electrical energy savings of 21% and 36% in terms of electrocoagulant delivery and unit log virus reduction, respectively. Neutron computed tomography revealed the critical role of electrode porosity in utilizing the electrode’s internal surface for electrodissolution and effective delivery of electrocoagulant to the bulk. Energy savings of up to 88% in short-term operation were obtained with porous electrodes in a continuous flow-through system. Further investigation on the impact of current density and porosity in long-term operation is desired as well as the capital cost of porous electrodes.

42 ENGINEERING↗