Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Compton”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A Bulk Comptonization Model for the Prompt GRB Emission and its Relation to the Fermi GRB Spectra

We present a model in which the GRB prompt emission at E ~ E(sub peak) is due to bulk Comptonization by the relativistic blast wave motion of either its own synchrotron photons of ambient photons of the stellar configuration that gave birth to the GRB. The bulk Comptonization process then induces the production of relativistic electrons of Lorentz factor equal to that of the blast wave through interactions with its ambient protons. The inverse compton emission of these electrons produces a power law component that extends to multi GeV energies in good agreement with the LAT GRB observations.

Kazanas, Demosthenes↗

Determining the Covering Factor of Compton-Thick Active Galactic Nuclei with NuSTAR

The covering factor of Compton-thick (CT) obscuring material associated with the torus in active galactic nuclei (AGNs) is at present best understood through the fraction of sources exhibiting CT absorption along the line of sight (N(sub H) greater than 1.5 x 10(exp 24) cm(exp −2)) in the X-ray band, which reveals the average covering factor. Determining this CT fraction is difficult, however, due to the extreme obscuration. With its spectral coverage at hard X-rays (greater than 10 keV), Nuclear Spectroscopic Telescope Array (NuSTAR) is sensitive to the AGNs covering factor since Compton scattering of X-rays off optically thick material dominates at these energies. We present a spectral analysis of 10 AGNs observed with NuSTAR where the obscuring medium is optically thick to Compton scattering, so-called CT AGNs. We use the torus models of Brightman and Nandra that predict the X-ray spectrum from reprocessing in a torus and include the torus opening angle as a free parameter and aim to determine the covering factor of the CT gas in these sources individually. Across the sample we find mild to heavy CT columns, with N(sub H) measured from 10(exp 24) to 10(exp 26) cm(exp −2), and a wide range of covering factors, where individual measurements range from 0.2 to 0.9. We find that the covering factor, f(sub c), is a strongly decreasing function of the intrinsic 2-10 keV luminosity, L(sub X), where f(sub c) = (−0.41 +/- 0.13)log(sub 10)(L(sub X)/erg s(exp −1))+18.31 +/- 5.33, across more than two orders of magnitude in L(sub X) (10(exp 41.5) - 10(exp 44) erg s(exp −1)). The covering factors measured here agree well with the obscured fraction as a function of LX as determined by studies of local AGNs with L(sub X) greater than 10(exp 42.5) erg s(exp −1).

NGC 4945↗

The Variable and Non-Variable X-Ray Absorbers in Compton-Thin Type II Active Galactic Nuclei

We have conducted an extensive X-ray spectral variability study of a sample of 20 Compton-thin type II galaxies using broadband spectra from XMM-Newton, Chandra, and Suzaku. The aim is to study the variability of the neutral intrinsic X-ray obscuration along the line of sight and investigate the properties and location of the dominant component of the X-ray-obscuring gas. The observations are sensitive to absorption columns of N(sub H) ∼ 10(exp 20.5–24) cm(exp -2) of fully and partially covering neutral and/or lowly ionized gas on timescales spanning days to well over a decade. We detected variability in the column density of the full-covering absorber in 7/20 sources, on timescales of months to years, indicating a component of compact-scale X-ray-obscuring gas lying along the line of sight of each of these objects. Our results imply that torus models incorporating clouds or over-dense regions should account for line-of-sight column densities as low as ∼a few ×10(exp 21) cm(exp -2). However, 13/20 sources yielded no detection of significant variability in the full-covering obscurer, with upper limits of ΔN(sub H) spanning 10(exp 21–23) cm(exp -2). The dominant absorbing media in these systems could be distant, such as kiloparsec-scale dusty structures associated with the host galaxy, or a homogeneous medium along the line of sight. Thus, we find that overall, strong variability in full-covering obscurers is not highly prevalent in Compton-thin type IIs, at least for our sample, in contrast to previous results in the literature. Finally, 11/20 sources required a partial-covering, obscuring component in all or some of their observations, consistent with clumpy near-Compton-thick compact-scale gas.

Active galaxies↗

Inverse Compton Cooling in the Coronae of Simulated Black Hole Accretion Flows

We present a formulation for a local cooling function to be employed in the diffuse, hot corona region of 3D GRMHD simulations of accreting black holes. This new cooling function calculates the cooling rate due to inverse Compton scattering by considering the relevant microphysics in each cell in the corona and approximating the radiation energy density and Compton temperature there by integrating over the thermal seed photon flux from the disk surface. The method either assumes ion and electron tem- peratures are equal (1T), or calculates them separately (2T) using an instantaneous equilibrium approach predicated on the actual relevant rate equations (Coulomb and Compton). The method is shown to be consistent with a more detailed ray-tracing calculation where the bulk of the cooling occurs, but is substantially less costly to per- form. As an example, we apply these methods to a harm3d simulation of a 10M⊙, non-spinning black hole, accreting at nominally 1% the Eddington value. Both 1T and 2T approaches lead to increased radiative efficiency and a larger fraction of total cooling in the corona as compared to the original target-temperature cooling function used by harm3d, especially in the 1T case. Time-averaged post-processing reveals that the continuum spectral observations predicted from these simulations are qualitatively similar to actual X-ray binary data, especially so for the 1T approach which yields a harder power-law component (Γ = 2.25) compared to the 2T version (Γ = 2.53).

Brooks E. Kinch↗

Measurement of Galactic 26Al with the Compton Spectrometer and Imager

The Compton Spectrometer and Imager (COSI) is a balloon-borne compact Compton telescope de-17signed to survey the 0.2–5 MeV sky. COSI’s energy resolution of ∼0.2% at 1.8 MeV, single-photon reconstruction, and wide field of view make it capable of studying astrophysical nuclear lines, particularly the 1809 keVγ-ray line from decaying Galactic 26Al. Most 26Al originates in massive stars and core-collapse supernova nucleosynthesis, but the path from stellar evolution models to Galaxy-wide emission remains unconstrained. In 2016, COSI had a successful 46-day flight on a NASA super pressure balloon. Here, we detail the first search for the 1809 keV26Al line in the COSI 2016 balloon flight using a maximum likelihood analysis. We find a Galactic 26Al flux of (8.6±2.5) ×10−4ph cm−2s−124 within the Inner Galaxy (|ℓ|≤30◦,|b|≤10◦) with 3.7σ significance above background. Within uncertainties, this flux is consistent with expectations from previous measurements by SPI and COMPTEL. This analysis demonstrates COSI’s powerful capabilities for studies of γ-ray lines and underscores the scientific potential of future compact Compton telescopes. In particular, the next iteration of COSI as a NASA Small Explorer satellite has recently been approved for launch in 2025.

Gamma-ray lines↗

Helium Compton Form Factor Measurements at CLAS

The distribution of the parton content of nuclei, as encoded via the generalized parton distributions (GPDs), can be accessed via the deeply virtual Compton scattering (DVCS) process contributing to the cross section for leptoproduction of real photons. Similarly to the scattering of light by a material, DVCS provides information about the dynamics and the spatial structure of hadrons. The sensitivity of this process to the lepton beam polarization allows to single-out the DVCS amplitude in terms of Compton form factors that contain GPDs information. The beam spin asymmetry of the $^4$He($\vec {\mathrm e}$,e$' \gamma ^4$He) process was measured in the experimental Hall B of the Jefferson Laboratory to extract the real and imaginary parts of the twist-2 Compton form factor of the $^4$He nucleus. The experimental results reported here demonstrate the relevance of this method for such a goal, and suggest the dominance of the Bethe-Heitler amplitude to the unpolarized process in the kinematic range explored by the experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High flux, narrow bandwidth compton light sources via extended laser-electron interactions

New configurations of lasers and electron beams efficiently and robustly produce high flux beams of bright, tunable, polarized quasi-monoenergetic x-rays and gamma-rays via laser-Compton scattering. Specifically, the use of long-duration, pulsed lasers and closely-spaced, low-charge and low emittance bunches of electron beams increase the spectral flux of the Compton-scattered x-rays and gamma rays, increase efficiency of the laser-electron interaction and significantly reduce the overall complexity of Compton based light sources.

42 ENGINEERING↗

Compton tomography system

A Compton tomography system comprises an x-ray source configured to produce a planar x-ray beam. The beam irradiates a slice of an object to be imaged, producing Compton-scattered x-rays. The Compton-scattered x-rays are imaged by an x-ray camera. Translation of the object with respect to the source and camera or vice versa allows three-dimensional object imaging.

47 OTHER INSTRUMENTATION↗

Methods for 2-color radiography with laser-compton X-ray sources

High-contrast, subtraction, x-ray images of an object are produced via scanned illumination by a laser-Compton x-ray source. The spectral-angle correlation of the laser-Compton scattering process and a specially designed aperture and/or detector are utilized to produce/record a narrow beam of x-rays whose spectral content consists of an on-axis region of high-energy x-rays surrounded by a region of slightly lower-energy x-rays. The end point energy of the laser-Compton source is set so that the high-energy x-ray region contains photons that are above the k-shell absorption edge (k-edge) of a specific contrast agent or specific material within the object to be imaged while the outer region consists of photons whose energy is below the k-edge of the same contrast agent or specific material. Scanning the illumination and of the object by this beam will simultaneously record and map the above edge and below k-edge absorption response of the object.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Precision measurement of Compton scattering in silicon with a skipper CCD for dark matter detection

Experiments aiming to directly detect dark matter through particle recoils can achieve energy thresholds of $\mathcal{O}(1\,\mathrm{eV})$. In this regime, ionization signals from small-angle Compton scatters of environmental $\gamma$-rays constitute a significant background. Monte Carlo simulations used to build background models have not been experimentally validated at these low energies. We report a precision measurement of Compton scattering on silicon atomic shell electrons down to 23$\,$eV. A skipper charge-coupled device (CCD) with single-electron resolution, developed for the DAMIC-M experiment, was exposed to a $^{241}$Am $\gamma$-ray source over several months. Features associated with the silicon K, L$_{1}$, and L$_{2,3}$-shells are clearly identified, and scattering on valence electrons is detected for the first time below 100$\,$eV. We find that the relativistic impulse approximation for Compton scattering, which is implemented in Monte Carlo simulations commonly used by direct detection experiments, does not reproduce the measured spectrum below 0.5$\,$keV. The data are in better agreement with $ab$$initio$ calculations originally developed for X-ray absorption spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Compton Polarimeter in Hall C of Jefferson

A new Compton polarimeter was installed in Hall C at Jefferson Lab and used during the Qweak experiment which aims to measure the weak charge of proton with a precision of 4.1%. In this polarimeter the electron beam collides with green laser light stored in a low gain Fabry-Perot Cavity; the scattered electrons are detected in 4 planes of a novel diamond micro strip detector while the back scattered photons are detected in a lead tungstate crystal. We extract the beam polarization by fitting the experimental asymmetry for each detector strip to the corresponding asymmetry calculated in QED. During the experiment, we took data to cross-calibrate Moller and Compton polarimeters in Hall C. We will share our preliminary conclusions from this comparison. In this talk, we will also present the results from Monte Carlo studies performed to estimate the systematic uncertainties of the polarization measurement along with comparing results from two independent extraction of the polarization involving very different time scales. The Compton polarimeter has achieved the design goals of 1% statistical uncertainty per hour and we expect to achieve less than 1% systematic uncertainty.

Narayan, Amrendra↗

Compton polarimeter during the Qweak experiment

Compton Polarimeter was successfully used during the Q$_{weak}$ experiment from Nov 2010 to May 2012 in Hall C, Jefferson Lab. In this newly installed Compton polarimeter the electron beam collides with green laser stored in a low gain Fabry-Perot Cavity; the scattered electrons are detected in 4 planes of a novel diamond micro strip detector while the back scattered photons are detected in four crystals of PbWO$_4$ detector. The analyzing power is computed using a Geant4 Monte Carlo simulation to match the real detector energy resolution and non-linearity in the response of the detector are folded in. The Compton polarimeter has achieved the design goals of 1\% statistical uncertainty per hour and we expect to achieve 1\% systematic uncertainty. We have done specific tests to understand various properties of the electron and photon detectors. We will share our study of the contributions to the electron and photon detector's systematic uncertainty along with the preliminary polarization results.

Narayan, Amrendra↗

Accurate, low-energy Compton polarimetry for Hall C at Jefferson Lab

A new Compton polarimeter has recently been commissioned in Hall C at Jefferson Lab in Newport News, VA, to provide a non-invasive, continuous measurement of electron beam polarization. The new Compton polarimeter is currently measuring electron beam polarization for Qweak, an experiment with a strict error budget allowing a combined statistical and systematic error of only $\pm1\%$ for beam polarization. Using well-established techniques we are able to determine electron beam polarization by measuring the scattering asymmetry of both the backscattered photons and the scattered electrons. Although the photon and electron detectors provide somewhat independent measurements they share the common systematic of the laser polarization. I discuss the optical setup for the photon target used in the Compton polarimeter and recent efforts in reducing systematic error in determination of laser polarization.

Jones, Donald↗

Generalized parton distributions from deep virtual compton scattering at CLAS

Here, we have analyzed the beam spin asymmetry and the longitudinally polarized target spin asymmetry of the Deep Virtual Compton Scattering process, recently measured by the Jefferson Lab CLAS collaboration. Our aim is to extract information about the Generalized Parton Distributions of the proton. By fitting these data, in a largely model-independent procedure, we are able to extract numerical values for the two Compton Form Factors $H_{Im}$ and $\tilde{H}_{Im}$ with uncertainties, in average, of the order of 30%.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On the mistake in the implementation of the minimal model of the dual parameterization and resulting inability to describe the high-energy DVCS data

We correct the mistaken claim made in~\cite{Guzey:2005ec,Guzey:2006xi} that the minimal model of the dual parameterization of nucleon generalized parton distributions (GPDs) gives a good, essentially model-independent description of high-energy data on deeply virtual Compton scattering (DVCS). In the implementation of the dual parameterization in~\cite{Guzey:2005ec,Guzey:2006xi}, the numerical prefactor of two in front of the DVCS amplitude was missing. We show that the corrected minimal model of the dual parameterization significantly overestimates the HERA data (H1 and ZEUS) on the DVCS cross section.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Use of Compton suppression gamma ray spectrometry to determine 239 Pu

We report 239 Pu has been characterized by gamma-ray spectroscopy for a level higher than the usual environmental ones typically needing alpha spectrometry, ICP-MS or TIMS. The higher activities typically have applications in reprocessing, safeguards verification, and nuclear forensics. For activities of hundreds of Bq/g, it is possible to use gamma ray spectrometry for 239 Pu characterization. A soil reference standard of 185 Bq/g (75 ng/g) was measured on a 79% efficient HPGe with a digital Compton suppression system. The ratios of the counting statistics for suppressed and unsuppressed uncertainties for various 239 Pu photopeaks were determined. The effects of self-attenuation on the low energy gamma rays were evaluated, and it was determined that Compton suppression was an effective characterization method of 239 Pu after accounting for self-attenuation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stability analysis of implicit time discretizations for the Compton-scattering Fokker-Planck equation

The Fokker-Planck equation is a widely used approximation for modeling the Compton scattering of photons in high energy density applications. In this paper, we perform a stability analysis of three implicit time discretizations for the Compton-Scattering Fokker-Planck equation. Specifically, we examine (i) a Semi-Implicit (SI) scheme that employs backward-Euler differencing but evaluates temperature-dependent coefficients at their beginning-of-time-step values, (ii) a Fully Implicit (FI) discretization that instead evaluates temperature-dependent coefficients at their end-of-time-step values, and (iii) a Linearized Implicit (LI) scheme, which is developed by linearizing the temperature dependence of the FI discretization within each time step. Our stability analysis shows that the FI and LI schemes are unconditionally stable and cannot generate oscillatory solutions regardless of time-step size, whereas the SI discretization can suffer from instabilities and nonphysical oscillations for sufficiently large time steps. With the results of this analysis, we present time-step limits for the SI scheme that prevent undesirable behavior. We test the validity of our stability analysis and time-step limits with a set of numerical examples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Stability analysis and time-step limits for a Monte Carlo Compton-scattering method

A Monte Carlo method for simulating Compton scattering in high energy density applications has been presented that models the photon-electron collision kinematics exactly [E. Canfield, W.M. Howard, E.P. Liang, Inverse Comptonization by one-dimensional relativistic electrons, Astrophys. J. 323 (1987) 565]. However, implementing this technique typically requires an explicit evaluation of the material temperature, which can lead to unstable and oscillatory solutions. In this paper, we perform a stability analysis of this Monte Carlo method and develop two time-step limits that avoid undesirable behavior. The first time-step limit prevents instabilities, while the second, more restrictive time-step limit avoids both instabilities and nonphysical oscillations. With a set of numerical examples, we demonstrate the efficacy of these time-step limits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗