SEARCH · Engineering Papers
Results for “Coil”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Designing a Magnetic Measurement Data Acquisition and Control System with Reuse in Mind: A Rotating Coil System Example
Explore the source record for details and available documents.
20 T DIPOLE MAGNET BASED ON HYBRID HTS/LTS COS-THETA COILS WITH STRESS MANAGEMENT*
Explore the source record for details and available documents.
Calibration and localization of optically pumped magnetometers using electromagnetic coils.
Abstract not provided.
Parametric Comparison of Additive Manufactured Rogowski Coil Diagnostics for Fast Nanosecond Pulses
Explore the source record for details and available documents.
Electromagnetic coils for a 3000 psi hydraulic MEMS valve assembly
Explore the source record for details and available documents.
Electromagnetic coils for a 3000 psi hydraulic MEMS valve assembly
Explore the source record for details and available documents.
Electromagnetic and mechanical modeling and analysis of the HTS dipole coil based on REBCO Twisted Stacked Tape (TST) cable and impregnated with Telene
Explore the source record for details and available documents.
MQXFA Coils and Magnets
Explore the source record for details and available documents.
Water-cooled Helmholtz Coil for Ultralow field Testing
Explore the source record for details and available documents.
Empirical Validation of Building Energy Modeling Input Parameters: Cooling Performance Curves of a Direct Expansion Coil
Explore the source record for details and available documents.
Calibration and localization of optically pumped magnetometers using electromagnetic coils.
Abstract not provided.
COPOLYMER COMPOSITES FOR HIGH VOLTAGE INSULATION WRAPS FOR SUPERCONDUCTING MAGNET COILS
Explore the source record for details and available documents.
Testing and Modeling of Subscale Ice-on-Coil Module as Low Temperature Reservoir for sCO2 based Pumped Thermal Energy Storage Systems
Echogen tested approximately 10 kWthsubscale IOC system in their lab in Akron, OH for studying the feasibility, endurance and performance impact of the technology on PTES system. This paper discusses the test loop setup, testing and results from this sub-scale IOC testing. Along with testing, the project team also developed sub-scale IOC transient model. The paper discusses this transient model development and its validation against the test data.
Project Title: Demonstration High Temperature Superconducting NonPlanar Stellarator Magnet with Advanced Manufactured Assemblies
This is the final report for the project “Demonstration High Temperature Superconducting Non- Planar Stellarator Magnet with Advanced Manufactured Assemblies”, funded by DOE, and performed by Type One Energy from September, 2020, to March 2024 involving the Fusion Technology Institute at the University of Wisconsin–Madison, the Plasma Science and Fusion Center (PSFC) at the Massachusetts Institute of Technology (MIT) and Commonwealth Fusion Systems (CFS) to design and fabricate the first non-planar HTS (REBCO) coil for a high-field stellarator based on the SPARC tokamak’s VIPER cable concept. Stellarators at high fields make high-temperature superconducting magnets necessary for a compact fusion device. But the asymmetric and non-planar nature of its components, especially the magnets make it difficult for scalable producibility. To address these challenges, two promising technologies have emerged: advanced manufacturing (AM) for the supporting plates for forming the magnets, and high-temperature superconducting (HTS) cables inside the plates. AM has advanced enough to produce stellarator components with the necessary geometric complexity, size, and the precision, leading to potentially significant reductions in production time, cost, and waste. The cost of HTS tape has decreased dramatically, and progress in HTS planar magnet development has reached a point where it can be proposed for application to complex 3D non-planar magnets. The main objective of this project is to develop, demonstrate and pre-commercialize a novel, non-planar HTS coil shape that remains superconducting to achieve production scalable reductions in time and cost and performance. The proposed technology is based on the novel concept of a precision sub-scale HTS nonplanar coil assembly. This project focuses on the design, fabrication, material optimization of cable design, and validation and demonstration of the high current carrying capability of superconducting magnets and their support in a complex 3D shape needed for application to stellarator magnetic plasma confinement. The specific objectives of this research program include: (1) The successful application of metal AM to build a precision sub-scale HTS nonplanar coil, (2) An HTS cable and cross-section design that can conform to the required nonplanar coil shape (bend radii as tight as 10-cm) and remains superconducting at an engineering current density of 1.35 kA/cm 2 at 77 K and 1 tesla at the conductor (5 kA in the cable). To achieve the above challenging goals, we have formed a multidisciplinary research team consisting of members from Type One Energy and UW-Madison, MIT PSFC and CFS with complementary skills and strong facilities. The team worked collaboratively on fundamental and applied research on the following three major technical areas: (1) Design, fabrication, and optimization of non-planar HTS Cable The ultimate goal of the project is to determine if commercial REBCO tapes and additive manufacturing can be used to fabricate high field (≥ 10T) non-planar coils with tight bending radii (≃ 100mm) and with a degradation of the critical current (Ic) smaller than 20% with respect to the expected performance. We started with shorter length cable to evaluate the scalability of the production process and eventually reached multiple turns for higher magnetic fields. Our findings suggest that a stellarator coil system of a relevant size, characterized by its asymmetric and non-planar components, can be fabricated using a formed cable in plate method. This system can be simulated using a large-scale modeling approach. The use of hybrid modeling 3 techniques will be pivotal in reducing the complexity of the model and in assessing expected performance in designs. (2) Modeling and simulation of the non-planar HTS Cable Multiphysics simulations are performed using the commercial software and are carried out in self-field conditions, involving 2D and 3D models and twisted around one slot of twist-pitched VIPER cable. Multiphysics simulations are mainly focused on the coil for the critical current evaluation, the magnetic field map, self-Lorentz forces and mechanical, and magnetothermal behavior and the quench dynamics. The detailed model and prediction of the superconducting performance of a stellarator-relevant demonstration cable from numerical simulations supports the results from the actual testing backing the results. A detailed description and results are provided in the later sections. (3) Design, fabrication, and optimization of support for the non-planar HTS Cable The team developed an additive manufactured (AM) coil positioning plate that formed into the required non-planar geometry (with bend radii as tight as 10-cm) and to acceptable tolerances required for a stellarator magnet: (+0.25-mm from ideal on dimensions of coil positioning plates and up to +1-mm from ideal for position of wound coil). The plate materials is also included in this selection process from fabrication and 3D printing perspective and commensurate with eventual application to a fusion reactor. From the cost effectiveness point of view, the HTS coil and plate has the potential to cost less than that made in conventional methods with less waste (<75% waste) reducing time (<50%) and cost (<50%), especially as the AM field matures. The application of advanced manufacturing in the construction of the support plates will also lead to cost reduction, as the cables can be easily replaced, thereby making the assembly modular. With such high primary cost and time savings, high current densities and magnetic field, the funded R&D work has validated the designs, proven the feasibility, and characterized the performance of the HTS coil and plate assembly, paving the way for a relevant-size stellarator coil system.
Nonlinear two-fluid modeling of plasma response to RMPs for the ELM control in the ITER baseline
Numerical modeling, combining the toroidal ideal MHD code GPEC and the nonlinear two-fluid MHD code TM1, was used for comprehensive studies of the plasma response to resonant magnetic perturbations (RMPs) with toroidal mode number n = 1–5 for controlling edge-localized modes (ELMs) in ITER for the standard operation scenario (15 MA Q = 10). Several issues related to RMP ELM control are investigated, including the optimization of the RMP coils configuration, the evaluation of the magnitude of density pump-out and the q95 windows of ELM suppression. GPEC calculates the magnetic response, which consistently includes the very important edge kink/peeling response to static magnetic perturbations. Furthermore, GPEC two-dimensional scans of the relative coil current phasing among the three rows of internal coils, at fixed coil current amplitude, reveal the optimal phasing for the RMP coil configuration with n = 1–5, respectively. The poloidal half wavelength of resonant mode at the edge of plasma calculated by GPEC indicates that the midplane row coils have the best resonant coupling with the plasma for n = 2, while the upper and lower row coils have the best resonant coupling with the plasma for n = 3. Based on the plasma kinetic equilibrium and the GPEC calculations of the magnetic response, TM1 was used to simulate the conditions for RMP field penetration in the ITER pedestal. TM1 shows magnetic island formation at the foot of ITER pedestal with RMP coil current threshold ranging from 4 kAt to 8 kAt with n = 2 to 4. These magnetic islands at the pedestal-foot lead to density pump-out, the magnitude of which scales as ${I}_{\text{RMP}}^{0.5}$ and ranges from 5% to 20% at the pedestal-top when scanning the coil current from 4 to 60 kAt. The density pump-out is found to be weaker for higher n RMP. The nonlinear TM1 simulations also show field penetration at the pedestal-top, where the threshold of RMP coil current depends on the q 95 . The alignment of the magnetic island and the location of the pedestal-top decreases the height and width of the pedestal to suppress ELMs. Simulations by two-dimensional scans of RMP coil current and q 95 reveal the accessible q 95 windows of ELM suppression for both n = 3 and 4 RMPs. The predicted q 95 windows of ELM suppression are very similar to the ones in currently operating tokamaks and the required RMP coil current for ELM suppression is less than 40–50 kAt, which is well within the designed capability for ITER. In addition, the simulations indicate that wide q 95 windows of ELM suppression may be accessible in ITER by operating with dominant n = 4 (or n = 5) RMPs.
Miniaturized Magnetoelastic Sensor System
This article describes the design, assembly, and implementation of a hand-held, magnetic-field-based sensor system that can be adapted for a variety of sensing applications. The miniaturized system is based on Chemical Identification by Magneto-Elastic Sensing (ChIMES) technology, which uses three concentric solenoid coils to wirelessly interrogate a sensor body comprised of a response material coupled to a magnetoelastic wire. The response material expands when it encounters a target, imposing mechanical stress on the wire and altering its magnetic permeability. The sensor bodies are passive, requiring no external power source, and they are small, measuring about 15 mm in length and 3.0 mm in diameter. Up to four sensor bodies can be configured as an evenly-spaced linear array. The sensor system operates by applying a low-frequency, current-stabilized, filtered triangle wave to a uniform-density excitation coil to switch the magnetic domains within the wire. Further, the responses from the sensors are picked up by a detection coil as stress-induced changes in the Faraday voltage, and the strong magnetic field induced by the excitation coil in the detection coil is nullified by a cancellation coil reverse-wound in series with the detection coil. The responses of the sensors in an array are separated in time by a linear gradient dc biasing coil. The sensors can be interrogated through metallic and nonmetallic barriers. The signals from the detection coil and the excitation coil are digitized by a pair of bipolar analog-to-digital converters (ADCs). A Raspberry Pi single-board computer (SBC) and associated software perform data acquisition and control all aspects of the sensor system hardware. The program allows the user to select the number of sensors in the array, the type of signal that is being collected, and the number of samples to take. The program also allows for signal processing of the sensor data, such as baseline correction. The program can differentiate sensor peaks from each other and calculate the magnitude of each sensor response with less than 1% error. The data are then displayed along with a graph of the signal.
Error field correction strategies in preparation to MAST-U operation
In magnetic fusion devices, unwanted non-axisymmetric magnetic field perturbations, known as error fields (EF), can have detrimental effects on plasma stability and confinement. Such EFs may originate from several sources, such as axi-symmetric coil misalignments, coil feeds, 3D structures in the wall surrounding the plasma, presence of ferromagnetic materials near the plasma surface, blanket materials in future devices. To minimize their impact on plasma performance and on the available operational space, it is important to identify the EF sources and develop EF control strategies. MAST Upgrade (MAST-U) is a spherical tokamak which will operate in the near future after a series of enhancements from the previous MAST experiment. To deliver a machine with EF amplitude low enough to allow a high quality experimental programme, systematic analysis of the intrinsic EF sources has been carried out for poloidal eld (P) and divertor (D) coils. To deliver a machine with EF amplitude low enough to allow a high quality experimental programme, systematic analysis of the intrinsic EF sources has been carried out for poloidal field (P) and divertor (D) coils, whose magnetic eld measurements were available when writing this paper. Such measurements reveal that P and D coils are 3D deformed and thus are responsible for intrinsic EFs, with mainly n=1 and n=2 toroidal mode numbers. In preparation to MAST-U operation, both passive and active EF control strategies have been adopted for n=1 and n=2 EFs compensation. Passive EF control consisted of installing finely each D and P coil within MAST-U device so as to minimize the intrinsic n=1 EF amplitude. The optimal coil alignment has been determined based on magnetic eld measurements and the corresponding 3D electro-magnetic modelling, and envisaged coil shift and tilt of 3.2 mm and 0.7 mrad, respectively, in the case of P coil named P4. Conversely, active control will be use during MAST-U operation to reduce the n=2 EF which is associated mainly with P4 and P5, as well. Since these coils have been re-used from the MAST device, studies attempting n=2 EF control, based on MAST plasmas, have been modelled utilizing the MARS-F code to interpret experimental results in MAST and to give hints for future n=2 EF control studies in MAST-U. Here, a model-based control set for n=2 EF control has been identified which would allow for the minimization of rotation braking, of the resonant magnetic field at the q=2 and of the plasma displacement in MAST-U, simultaneously.