Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Centroid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Maximum-Intensity Volumes for Fast Contouring of Lung Tumors Including Respiratory Motion in 4DCT Planning

Purpose: To assess the accuracy of maximum-intensity volumes (MIV) for fast contouring of lung tumors including respiratory motion. Methods and Materials: Four-dimensional computed tomography (4DCT) data of 10 patients were acquired. Maximum-intensity volumes were constructed by assigning the maximum Hounsfield unit in all CT volumes per geometric voxel to a new, synthetic volume. Gross tumor volumes (GTVs) were contoured on all CT volumes, and their union was constructed. The GTV with all its respiratory motion was contoured on the MIV as well. Union GTVs and GTVs including motion were compared visually. Furthermore, planning target volumes (PTVs) were constructed for the union of GTVs and the GTV on MIV. These PTVs were compared by centroid position, volume, geometric extent, and surface distance. Results: Visual comparison of GTVs demonstrated failure of the MIV technique for 5 of 10 patients. For adequate GTV{sub MIV}s, differences between PTVs were <1.0 mm in centroid position, 5% in volume, {+-}5 mm in geometric extent, and {+-}0.5 {+-} 2.0 mm in surface distance. These values represent the uncertainties for successful MIV contouring. Conclusion: Maximum-intensity volumes are a good first estimate for target volume definition including respiratory motion. However, it seems mandatory to validate each individual MIV by overlaying it on a movie loop displaying the 4DCT data and editing it for possible inadequate coverage of GTVs on additional 4DCT motion states.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inferring Positions of Tumor and Nodes in Stage III Lung Cancer From Multiple Anatomical Surrogates Using Four-Dimensional Computed Tomography

Purpose: To investigate the feasibility of modeling Stage III lung cancer tumor and node positions from anatomical surrogates. Methods and Materials: To localize their centroids, the primary tumor and lymph nodes from 16 Stage III lung cancer patients were contoured in 10 equal-phase planning four-dimensional (4D) computed tomography (CT) image sets. The centroids of anatomical respiratory surrogates (carina, xyphoid, nipples, mid-sternum) in each image set were also localized. The correlations between target and surrogate positions were determined, and ordinary least-squares (OLS) and partial least-squares (PLS) regression models based on a subset of respiratory phases (three to eight randomly selected) were created to predict the target positions in the remaining images. The three-phase image sets that provided the best predictive information were used to create models based on either the carina alone or all surrogates. Results: The surrogate most correlated with target motion varied widely. Depending on the number of phases used to build the models, mean OLS and PLS errors were 1.0 to 1.4 mm and 0.8 to 1.0 mm, respectively. Models trained on the 0%, 40%, and 80% respiration phases had mean ({+-} standard deviation) PLS errors of 0.8 {+-} 0.5 mm and 1.1 {+-} 1.1 mm for models based on all surrogates and carina alone, respectively. For target coordinates with motion >5 mm, the mean three-phase PLS error based on all surrogates was 1.1 mm. Conclusions: Our results establish the feasibility of inferring primary tumor and nodal motion from anatomical surrogates in 4D CT scans of Stage III lung cancer. Using inferential modeling to decrease the processing time of 4D CT scans may facilitate incorporation of patient-specific treatment margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive Radiation Therapy for Postprostatectomy Patients Using Real-Time Electromagnetic Target Motion Tracking During External Beam Radiation Therapy

Purpose: Using real-time electromagnetic (EM) transponder tracking data recorded by the Calypso 4D Localization System, we report inter- and intrafractional target motion of the prostate bed, describe a strategy to evaluate treatment adequacy in postprostatectomy patients receiving intensity modulated radiation therapy (IMRT), and propose an adaptive workflow. Methods and Materials: Tracking data recorded by Calypso EM transponders was analyzed for postprostatectomy patients that underwent step-and-shoot IMRT. Rigid target motion parameters during beam delivery were calculated from recorded transponder positions in 16 patients with rigid transponder geometry. The delivered doses to the clinical target volume (CTV) were estimated from the planned dose matrix and the target motion for the first 3, 5, 10, and all fractions. Treatment adequacy was determined by comparing the delivered minimum dose (D{sub min}) with the planned D{sub min} to the CTV. Treatments were considered adequate if the delivered CTV D{sub min} is at least 95% of the planned CTV D{sub min}. Results: Translational target motion was minimal for all 16 patients (mean: 0.02 cm; range: −0.12 cm to 0.07 cm). Rotational motion was patient-specific, and maximum pitch, yaw, and roll were 12.2, 4.1, and 10.5°, respectively. We observed inadequate treatments in 5 patients. In these treatments, we observed greater target rotations along with large distances between the CTV centroid and transponder centroid. The treatment adequacy from the initial 10 fractions successfully predicted the overall adequacy in 4 of 5 inadequate treatments and 10 of 11 adequate treatments. Conclusion: Target rotational motion could cause underdosage to partial volume of the postprostatectomy targets. Our adaptive treatment strategy is applicable to post-prostatectomy patients receiving IMRT to evaluate and improve radiation therapy delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Audio-Visual Biofeedback Does Not Improve the Reliability of Target Delineation Using Maximum Intensity Projection in 4-Dimensional Computed Tomography Radiation Therapy Planning

Purpose: To investigate whether coaching patients' breathing would improve the match between ITV{sub MIP} (internal target volume generated by contouring in the maximum intensity projection scan) and ITV{sub 10} (generated by combining the gross tumor volumes contoured in 10 phases of a 4-dimensional CT [4DCT] scan). Methods and Materials: Eight patients with a thoracic tumor and 5 patients with an abdominal tumor were included in an institutional review board-approved prospective study. Patients underwent 3 4DCT scans with: (1) free breathing (FB); (2) coaching using audio-visual (AV) biofeedback via the Real-Time Position Management system; and (3) coaching via a spirometer system (Active Breathing Coordinator or ABC). One physician contoured all scans to generate the ITV{sub 10} and ITV{sub MIP}. The match between ITV{sub MIP} and ITV{sub 10} was quantitatively assessed with volume ratio, centroid distance, root mean squared distance, and overlap/Dice coefficient. We investigated whether coaching (AV or ABC) or uniform expansions (1, 2, 3, or 5 mm) of ITV{sub MIP} improved the match. Results: Although both AV and ABC coaching techniques improved frequency reproducibility and ABC improved displacement regularity, neither improved the match between ITV{sub MIP} and ITV{sub 10} over FB. On average, ITV{sub MIP} underestimated ITV{sub 10} by 19%, 19%, and 21%, with centroid distance of 1.9, 2.3, and 1.7 mm and Dice coefficient of 0.87, 0.86, and 0.88 for FB, AV, and ABC, respectively. Separate analyses indicated a better match for lung cancers or tumors not adjacent to high-intensity tissues. Uniform expansions of ITV{sub MIP} did not correct for the mismatch between ITV{sub MIP} and ITV{sub 10}. Conclusions: In this pilot study, audio-visual biofeedback did not improve the match between ITV{sub MIP} and ITV{sub 10}. In general, ITV{sub MIP} should be limited to lung cancers, and modification of ITV{sub MIP} in each phase of the 4DCT data set is recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predicting U 3 O 8 powder processing conditions: An AI/ML approach analyzing deep learning embeddings of SEM micrographs

High-resolution SEM images of uranium-oxide powders encode micro- and nanoscale clues to their synthesis route and calcination temperature. We trained a ResNet-50 model on 11 commercial-scale U₃O₈ classes, ammonium diuranate (ADU) or uranyl peroxide (H₂O₂) precursors calcined at temperatures ranging from 400 to 750 °C and added a 256-D projection head before the classifier to analyze the learned representation. The best of eight seeds reached 92.4 % accuracy on reserved testing data, but our focus is the structure of the embedding space rather than the accuracy and labels. We quantify class relatedness in the original 256-D space using centroid similarity and distributional distances, and we use Uniform Manifold Approximation Projection (UMAP) for visualization. ‘Unknown’ images from different preparation methods, SEM operators, and from the literature localized near the expected classes under a nearest-centroid analysis without retraining, as well as clustered in similar UMAP space. In conclusion, this embedding-centered workflow complements black-box classification by providing quantitative, similarity-based comparisons of U₃O₈ morphologies and reduces storage space by up to 98 % for image data used in millisecond vector search comparisons.

36 MATERIALS SCIENCE↗

Stereology of backscatter electron images of etched surfaces for characterization of particle size distributions and volume fractions: Estimation of imaging bias via Monte Carlo simulations

On metallic specimens in which a secondary phase has been selectively removed by a chemical etchant, the use of backscatter electron (BSE) imaging yields images that are more readily segmented with image processing algorithms than other modes of imaging in the scanning electron microscope. The contrast mechanisms in this imaging mode, however, produce a bias in the observation of particle sizes and volume fractions due to the effects of the electron interaction volume in the specimen. This stereological bias is quantified using Monte Carlo (MC) simulation of backscatter images. It is observed that the overprojection of features with centroids residing beneath the plane of polish is largely canceled out by the reduced segmentation size of features with centroids residing above the plane of polish. - Research Highlights: {yields} Backscatter imaging of selectively-etched surfaces can facilitate segmentation. {yields} Backscatter imaging of voids is simulated to estimate imaging/observation biases. {yields} The biases are quantified and incorporated into the stereological calculation. {yields} Systematic errors and imaging biases are observed to counteract one another. {yields} Results are illustrated using a bimodal gamma prime distribution in a Ni superalloy.

36 MATERIALS SCIENCE↗

Intra and Interfraction Mediastinal Nodal Region Motion: Implications for Internal Target Volume Expansions

The purpose of this study was to determine the intra and interfraction motion of mediastinal lymph node regions. Ten patients with nonsmall-cell lung cancer underwent controlled inhale and exhale computed tomography (CT) scans during two sessions (40 total datasets) and mediastinal nodal stations 1-8 were outlined. Corresponding CT scans from different sessions were registered to remove setup error and, in this reference frame, the centroid of each nodal station was compared for right-left (RL), anterior-posterior (AP), and superior-inferior (SI) displacement. In addition, an anisotropic volume expansion encompassing the change of the nodal region margins in all directions was used. Intrafraction displacement was determined by comparing same session inhale-exhale scans. Interfraction reproducibility of nodal regions was determined by comparing the same respiratory phase scans between two sessions. Intrafraction displacement of centroid varied between nodal stations. All nodal regions moved posteriorly and superiorly with exhalation, and inferior nodal stations showed the most motion. Based on anisotropic expansion, nodal regions expanded mostly in the RL direction from inhale to exhale. The interpatient variations in intrafraction displacement were large compared with the displacements themselves. Moreover, there was substantial interfractional displacement ({approx}5 mm). Mediastinal lymph node regions clearly move during breathing. In addition, deformation of nodal regions between inhale and exhale occurs. The degree of motion and deformation varies by station and by individual. This study indicates the potential advantage of characterizing individualized nodal region motion to safely maximize conformality of mediastinal nodal targets.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of setup error using different reference images: a phantom and lung cancer patients study

The purpose of this study was to compare setup errors obtained with kilovoltage cone-beam computed tomography (CBCT) and 2 different kinds of reference images, free-breathing 3D localization CT images (FB-CT) and the average images of 4-D localization CT images (AVG-CT) for phantom and lung cancer patients. This study also explored the correlation between the difference of translational setup errors and the gross tumor volume (GTV) motion. A respiratory phantom and 14 patients were enrolled in this study. For phantom and each patient, 3D helical CT and 4D CT images were acquired, and AVG-CT images were generated from the 4D CT. The setup errors were determined based on the image registration between the CBCT and the 2 different reference images, respectively. The data for both translational and rotational setup errors were analyzed and compared. The GTV centroid movement as well as its correlation with the translational setup error differences was also evaluated. In the phantom study, the AVG-CT method was more accurate than the FB-CT method. For patients, the translational setup errors based on FB-CT were significantly larger than those from AVG-CT in the left-right (LR), superior-inferior (SI), and anterior-posterior (AP) directions (p < 0.05). Translational setup errors differed by >1 mm in 32.6% and >2 mm in 12.9% of CBCT scans. The rotational setup errors from FB-CT were significantly different from those from AVG-CT in the LR and AP directions (p < 0.05). The correlation coefficient of the translational setup error differences and the GTV centroid movement in the LR, SI, and AP directions was 0.515 (p = 0.060), 0.902 (p < 0.001), and 0.510 (p = 0.062), respectively. For lung cancer patients, respiration may affect the on-line target position location. AVG-CT provides different reference information than FB-CT. The difference in SI direction caused by the 2 methods increases with the GTV movement. Therefore, AVG-CT should be the prefered choice of reference images.

61 RADIATION PROTECTION AND DOSIMETRY↗

Measurement and analysis of fast transient instabilities

In this study, a novel beam diagnostics technique to detect fast beam transient instabilities and glitches has been developed at National Synchrotron Light Source II (NSLS-II). Vertical spikes of beam size and centroid have been observed occasionally and randomly during high current operations. These spikes are believed to be caused by ion instabilities associated with vacuum activity localized in the ring. With the functionality of gated beam position monitor (BPM), the newly developed technique utilizes turn-by-turn (TBT) data to detect beam centroid glitches. Whenever one turn trajectory deviates from a predefined window, a global control event is generated to trigger an online TBT data acquisition. The data acquisition is synchronized for all BPMs around the ring. In the meantime, the bunch-by-bunch (BxB) data, which is acquired from a single dedicated feedback BPM, has also been collected for analyzing possible coupled bunch instabilities (CBI). In addition to CBI caused mainly by ion bursts, other types of fast transient motions, such as, the top-off residual disturbance and fast orbit disturbance, have been captured with the new tool. Lastly, the sources of the glitches can be approximately localized with the synchronized TBT data from multiple BPMs around the ring.

43 PARTICLE ACCELERATORS↗

Isoscalar and isovector giant resonances in 44 Ca, 54 Fe, 64,68 Zn and 56,58,60,68 Ni

We have studied the uncharacteristic behavior of the measured values of the isoscalar and isovector centroid energies, E CEN , of nuclear giant resonances of multipolarity from L = 0 to L = 3 in 44 Ca, 54 Fe, 64,68 Zn and 56,58,60,68 Ni. For this purpose, we carried out calculations of E CEN within the spherical Hartree-Fock (HF)-based random phase approximation (RPA) theory with 33 distinct Skyrme-like effective nucleon-nucleon interactions. We have also determined the Pearson linear correlation coefficients between centroid energies, obtained from the HF-RPA, and the various properties of nuclear matter (NM) of each interaction and determined the sensitivity of E CEN to NM properties. We compared the theoretical values of E CEN obtained from the HF-RPA calculations with experimental data and discuss the results, pointing out significant disagreements between theoretical and experimental values. We note in particular, that we obtain good agreement for the theoretical E CEN of the isovector giant dipole resonance and the available experimental data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermalization of nuclear matter in heavy-ion collisions at Fermi energies

We analyze the time evolution of the kinetic properties of nuclear matter produced in heavy-ion collisions at Fermi energies. The collision system is simulated using Constrained Molecular Dynamics (CoMD) transport calculations whose output is the isospin, position, and momentum of the nucleons. Focusing on central 35 A·MeV 40 Ca+ 40 Ca collisions we utilize this information to extract localized momentum distributions in volume elements of 8 fm 3 and time steps of 5 fm/$c$. We then parameterize the single-particle momentum distributions with thermally motivated fit functions in the local rest frame of each cell. While the transverse-momentum distributions are well reproduced by thermal ones, the longitudinal ones carry a marked imprint of the initial nuclear motion which we capture by introducing a centroid motion into our fit functions. In particular, we find that Fermi distributions yield significantly better fits than Boltzmann ones, a consequence of the Pauli blocking implemented in CoMD. From the fits we extract the time dependence of the thermodynamic and collective properties of the excited nuclear medium. We find that the transverse temperature gradually rises to about 6 MeV, which is accompanied by a dissipation of the initial centroid motion of the incoming nuclei which vanishes at about 100 fm/c after initial impact. In conclusion, we are therefore able to track the transition of beam energy into random kinetic energy for nucleons, suggesting a three-dimensional equilibration of energy in the late stages of the collision.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

R –8 Dispersion Interaction: Derivation and Application to the Effective Fragment Potential Method

The anisotropic and isotropic R –8 dispersion contributions (disp8) are derived and implemented within the framework of the effective fragment potential (EFP) method formulated with imaginary frequency-dependent Cartesian polarizability tensors distributed at the centroids of the localized molecular orbitals (LMOs). Two forms of damping functions, intermolecular overlap-based and Tang–Toennies, are extended for disp8. To obtain LMO polarizability tensors centered at LMO centroids, an origin-shifting transformation is derived and implemented for the dipole–octopole polarizability tensor and the quadrupole–quadrupole polarizability tensor. The analytic gradient is derived and implemented for the isotropic disp8 contribution. Relative to the previously implemented empirical EFP disp8 energy, the isotropic disp8 component of the interaction energy improves the overall agreement of the EFP dispersion energies with the symmetry-adapted perturbation theory (SAPT) benchmarks, reducing the mean absolute errors (MAEs) and mean absolute percentage errors for most of the databases examined in this work. Further, while the anisotropic disp8 can further enhance the accuracy of the EFP dispersion energy and yield smaller MAEs, significantly overbound dispersion energies are predicted by the anisotropic disp8 when the maximum element in the intermolecular overlap matrix is greater than 0.1, possibly due to the breakdown of the approximations made in the EFP dispersion derivation at a short range. For potential energy scan databases, the newly developed EFP dispersion model with isotropic disp8 yields the overall correct curvature and good agreement with SAPT benchmarks around equilibrium and longer but overestimates the dispersion interactions at a short range. While the overlap-based dispersion-damping functions produce better MAEs than Tang–Toennies damping functions, further improvement is needed to better screen the large attractive dispersion energies at a short range (overlap >0.1).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhanced Charge Transport in 2D Perovskites via Fluorination of Organic Cation

Organic-inorganic halide perovskites incorporating two-dimensional (2D) structures have shown promise for enhancing the stability of perovskite solar cells (PSCs). However, the bulky spacer cations often limit charge transport. Here, we report on a simple approach based on molecular design of the organic spacer to improve the transport properties of 2D perovskites, and we use phenethylammonium (PEA) as an example. We demonstrate that by fluorine substitution on the para position in PEA to form 4-fluorophenethylammonium (F-PEA), the average phenyl ring centroid-centroid distances in the organic layer become shorter with better aligned stacking of perovskite sheets. The impact is enhanced orbital interactions and charge transport across adjacent inorganic layers as well as increased carrier lifetime and reduced trap density. Using a simple perovskite deposition at room temperature without using any additives, we obtained a power conversion efficiency of >13% for (F-PEA) 2 MA 4 Pb 5 I 16 -based PSCs. In addition, the thermal stability of 2D PSCs based on F-PEA is significantly enhanced compared to those based on PEA.

14 SOLAR ENERGY↗

Relocation of Light and Moderate-Magnitude ( M 4-6) Seismicity Along the Central Mid-Atlantic

In this study, we estimate precise relative epicentroid locations of earthquakes along the Mid-Atlantic Ridge (MAR) between 12°N and 19°N using intermediate-period Rayleigh and Love wave cross-correlation measurements. We relocate 152 earthquakes with magnitudes ranging between 4.0 and 6.0 and when possible use P waveform modeling to estimate centroid depths. We compare surface-wave locations to locations in the U.S. Geological Survey, Global Centroid Moment Tensor, and Pacific Marine Environmental Laboratory hydroacoustic catalogs (Smith et al., 2002, https://doi.org/10.1029/2001GL013912) and demonstrate that surface-wave based relative location techniques provide significant improvement on precision. Our analyses shift locations to more tectonically consistent alignments that correlate strongly with bathymetric features. Relocations along the Fifteen-Twenty and Marathon Fracture Zones (FZs) move to within a few kilometers of the transform bathymetry. Events along ridge segments scatter over a distance of about 10–20 km perpendicular to the local plate boundary and most ridge-segment seismicity clusters spatially. North of the Fifteen-Twenty FZ, ridge events along several segments locate preferentially in the North American Plate, suggesting recent asymmetric seismic strain release and perhaps asymmetric spreading. Along the ridge between 13°N and 14°N, moderate-magnitude seismic strain release concentrates in an area with two active oceanic core complexes (OCC) along the western rift boundary, but the largest events along this segment appear to occur along the eastern boundary rift valley faults and represent deformation opposite the OCC detachment surface processes. Finally, precise moderate-magnitude earthquake epicentroid locations for events that occurred over the last few decades complement the results of temporary seismometer deployments that have imaged microseismic activity along the MAR.

58 GEOSCIENCES↗

Subtropical marine low stratiform cloud deck spatial errors in the E3SMv1 Atmosphere Model

Marine low-level clouds continue to be poorly simulated in models despite many studies and field experiments devoted to their improvement. Here we focus on the spatial errors in the cloud decks in the Department of Energy Earth system model (E3SM) relative to the satellite climatology by calculating centroid distances, area ratios, and overlap ratios. Since model dynamics is better simulated than clouds, these errors are attributed primarily to the model physics. To gain additional insight, we performed a sensitivity run in which model winds were nudged to those of reanalysis. This results in a large change (but not necessarily an improvement) in the simulated cloud decks. These differences between simulations are mainly due to the interactions between model dynamics and physics. These results suggest that both model physics (widely recognized) and its interaction with dynamics (less recognized) are important to model improvement in simulating these low-level clouds.

Brunke, Michael A.↗

A faux hawk fullerene with PCBM-like properties

Reaction of C 60 , C 6 F 5 CF 2 I, and SnH(n-Bu) 3 produced, among other unidentified fullerene derivatives, the two new compounds 1,9-C 60 (CF 2 C 6 F 5 )H (1) and 1,9-C 60 (cyclo-CF 2 (2-C 6 F 4 )) (2). The highest isolated yield of 1 was 35% based on C60. Depending on the reaction conditions, the relative amounts of 1 and 2 generated in situ were as high as 85% and 71%, respectively, based on HPLC peak integration and summing over all fullerene species present other than unreacted C60. Compound 1 is thermally stable in 1,2-dichlorobenzene (oDCB) at 160 °C but was rapidly converted to 2 upon addition of Sn 2 (n-Bu) 6 at this temperature. In contrast, complete conversion of 1 to 2 occurred within minutes, or hours, at 25 °C in 90/10 (v/v) PhCN/C 6 D 6 by addition of stoichiometric, or sub-stoichiometric, amounts of proton sponge (PS) or cobaltocene (CoCp 2 ). DFT calculations indicate that when 1 is deprotonated, the anion C 60 (CF 2 C 6 F 5 )- can undergo facile intramolecular SNAr annulation to form 2 with concomitant loss of F-. To our knowledge this is the first observation of a fullerene-cage carbanion acting as an S N Ar nucleophile towards an aromatic C–F bond. The gas-phase electron affinity (EA) of 2 was determined to be 2.805(10) eV by low-temperature PES, higher by 0.12(1) eV than the EA of C 60 and higher by 0.18(1) eV than the EA of phenyl-C 61 -butyric acid methyl ester (PCBM). In contrast, the relative E 1/2 (0/-) values of 2 and C 60 , -0.01(1) and 0.00(1) V, respectively, are virtually the same (on this scale, and under the same conditions, the E1/2(0/-) of PCBM is -0.09 V). Time-resolved microwave conductivity charge-carrier yield × mobility values for organic photovoltaic active-layer-type blends of 2 and poly-3-hexylthiophene (P3HT) were comparable to those for equimolar blends of PCBM and P3HT. The structure of solvent-free crystals of 2 was determined by single-crystal X-ray diffraction. The number of nearest-neighbor fullerene–fullerene interactions with centroid···centroid (⊙···⊙) distances of ≤10.34 Å is significantly greater, and the average ⊙···⊙ distance is shorter, for 2 (10 nearest neighbors; ave. ⊙···⊙ distance = 10.09 Å) than for solvent-free crystals of PCBM (7 nearest neighbors; ave. ⊙···⊙ distance = 10.17 Å). Finally, the thermal stability of 2 was found to be far greater than that of PCBM.

14 SOLAR ENERGY↗

Locating the missing large-scale emission in the jet of M87* with short EHT baselines

In very-long baseline interferometric arrays, nearly co-located stations probe the largest scales and typically cannot resolve the observed source. In the absence of a large-scale structure, closure phases constructed with these stations are zero and, since they are independent of station-based errors, they can be used to probe data issues. Here, we show how these trivial closure phases become nonzero with a brightness distribution on smaller scales than their short baseline would suggest. When applied to sources that are made up of a bright compact and large-scale diffuse component, the trivial closure phases directly measure the centroid relative to the compact source and higher-order image moments. We present a technique to measure these image moments with minimal model assumptions and validate it on synthetic Event Horizon Telescope (EHT) data. We then apply this technique to 2017 and 2018 EHT observations of M87* and find a weak preference for extended emission in the direction of the large-scale jet. We also apply it to 2021 EHT data and measure the source centroid about 1 mas northwest of the compact ring, which is consistent with the jet observed at lower frequencies.

79 ASTRONOMY AND ASTROPHYSICS↗

Improvement of the intrinsic time resolving power of the Cologne iron-free orange type electron spectrometers

Conversion electron spectroscopy represents an important tool for nuclear structure analysis of medium and heavy nuclei. Two iron-free magnetic electron spectrometers of the orange type have been installed at the Institute for Nuclear Physics of the University of Cologne. The very large transmission of 15% and the very good energy resolution of 1% makes the iron-free orange spectrometer a powerful instrument. By means of fast timing techniques, lifetimes of nuclear excited states can be measured with an accuracy better than 20 ps. For the first time, the energy dependent centroid position of prompt events yielding the time-walk characteristics (the prompt curve) of the orange spectrometer fast timing setup has been measured using prompt secondary {delta}-electrons generated in a pulsed beam experiment. The prompt curve calibrated as a function of energy allows precise lifetime determination down to a few tens of picoseconds by the use of the centroid shift method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗