Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CURRENT AMPLIFIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Suppression of MHD modes with active phase-control of probe-injected currents

Abstract Active phase-control of probe-injected current is shown to both suppress and amplify long-wavelength rotating magnetohydrodynamic instabilities in the HBT-EP tokamak. Four probes are connected in quadrature and energized to drive non-axisymmetric currents through the edge of the tokamak, creating magnetic perturbations comparable to previously-studied saturated kink modes or resonant magnetic perturbations that are generated by an external control coil array. Measurements of the magnetic perturbations from the probe-injected currents determine a set of current-carrying helical filaments used to model active feedback control of resistive wall modes. These experiments suggest current-injection feedback may be an effective alternative to external control coils for control of RWMs and other long-wavelength kink-like modes at the edge of tokamaks.

Physics↗

Field-effect transistor improves electrometer amplifier

An electrometer amplifier uses a field effect transistor to measure currents of low amperage. The circuit, developed as an ac amplifier, is used with an external filter which limits bandwidth to achieve optimum noise performance.

Munoz, R.↗

High temperature charge amplifier for geothermal applications

An amplifier circuit in a multi-chip module includes a charge to voltage converter circuit, a voltage amplifier a low pass filter and a voltage to current converter. The charge to voltage converter receives a signal representing an electrical charge and generates a voltage signal proportional to the input signal. The voltage amplifier receives the voltage signal from the charge to voltage converter, then amplifies the voltage signal by the gain factor to output an amplified voltage signal. The lowpass filter passes low frequency components of the amplified voltage signal and attenuates frequency components greater than a cutoff frequency. The voltage to current converter receives the output signal of the lowpass filter and converts the output signal to a current output signal; wherein an amplifier circuit output is selectable between the output signal of the lowpass filter and the current output signal.

15 GEOTHERMAL ENERGY↗

A pulsed current-mode class-D low-voltage high-bandwidth power amplifier for portable NMR systems

Low-field NMR has seen growing interest in recent years, especially for portable applications. The lower homogeneity magnets used for portable applications require short RF pulses to ensure enough transmit bandwidth to excite the sample volume and also support short echo periods. Furthermore, the preferred use of a high-Q coil to improve signal-to-noise ratio (SNR) prolongs the pulse transients. Thus, at such low Larmor frequencies, the excitation pulse transients become comparable or longer than the pulse length, such that the transmit bandwidth begins to limit measurement SNR. This paper describes the design of a pulsed current-mode class-D power (PCMCD) transmitter that addresses this issue by generating high power in a tuned sample coil while maintaining short transients, thus resulting in high output bandwidth. The transmitter also uses a charge recycling mechanism to maximize power efficiency for RF train excitation, which also results in faster pulse repetition rate and reduces allowable echo time. In this work, experimental results from a small form-factor PCMCD transmitter are presented. This design generates a peak RF power of 240 W into a 9.16 µH coil at 4 MHz while operating off a single 12 V power supply. NMR measurement results using the transmitter are also described, showing minimum achievable echo time of 70 µs and 25 µs depending on the transmitter mode of operation.

47 OTHER INSTRUMENTATION↗

Evaluation of outer flaws in titanium alloys using eddy current measuring system

In this paper results of shallow outer flaw detection in thick titanium alloy specimens is presented. In order to increase efficiency of inspections of minor defects an eddy current measuring system with a lock-in amplifier was used. The measurements were carried out for flat and cylindrical specimens with artificial flaws.

36 MATERIALS SCIENCE↗

Orbital performance of communication satellite microwave power amplifiers (MPAs)

This paper presents background data on the performance of microwave power amplifiers (MPAs) used as transmitters in currently operating commercial communication satellites. Specifically aspects of two competing MPA types are discussed. These are well known TWTA (travelling wave tube amplifier) and the SSPA (solid state power amplifier). Extensive in-orbit data has been collected from over 2000 MPAs in 1991 and 1993. The study in 1991 invovlved 75 S/C (spacecraft) covering 463 S/C years. The 1993 'second-look' study encompassed a slightly different population of 72 S/C with 497 S/C years of operation. A surprising result of both studies was that SSPAs, although quite reliable, did not achieve the reliability of TWTAs were one-third more reliable in the 1993 study. This was at C-band with comparable power amplifiers, e.g. 6-16W of RF output power and similar gains. Data at K(sub u)-band is for TWTAs only since there are no SSPAs in the current S/C inventory. The other complementary result was that the projected failure rates used as S/C payload design guidelines were, on average, somewhat higher for TWTAs than the actual failure rates uncovered by this study. SSPA rates were as projected.

Strauss, R.↗

Fiber Lasers and Amplifiers for Space-based Science and Exploration

We present current and near-term uses of high-power fiber lasers and amplifiers for NASA science and spacecraft applications. Fiber lasers and amplifiers offer numerous advantages for the deployment of instruments on exploration and science remote sensing satellites. Ground-based and airborne systems provide an evolutionary path to space and a means for calibration and verification of space-borne systems. NASA fiber-laser-based instruments include laser sounders and lidars for measuring atmospheric carbon dioxide, oxygen, water vapor and methane and a pulsed or pseudo-noise (PN) code laser ranging system in the near infrared (NIR) wavelength band. The associated fiber transmitters include high-power erbium, ytterbium, and neodymium systems and a fiber laser pumped optical parametric oscillator. We discuss recent experimental progress on these systems and instrument prototypes for ongoing development efforts.

Fiber laser↗

Local regulation of interchange turbulence in a dipole-confined plasma torus using current-collection feedback

Turbulence in plasma confined by a magnetic dipole is dominated by interchange fluctuations with complex dynamics and short spatial coherence. We report the first use of local current-collection feedback to modify, amplify, and suppress these fluctuations. The spatial extent of turbulence regulation is limited to a correlation length near the collector. Changing the gain and phase of collection results in power either extracted from or injected into the turbulence. The measured plasma response shows some agreement with calculations of the linear response of global interchange-like MHD and entropy modes to current-collection feedback.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photoelectron spectrometer with means for stabilizing sample surface potential

An improved X-ray photoelectron spectrometer is disclosed, which includes circuit means to determine the surface potential of a sample, e.g., an insulator. The circuit means comprise an electron gun, whose potential is modulated at a preselected frequency above and below a selected potential with respect to the spectrometer common potential, e.g., ground. The beam of electrons is directed to the sample surface. The sample's surface potential is offset by an offset power supply with respect to the spectrometer common potential until the ac current which flows through the sample reaches a peak amplitude. A lock-in amplifier is included to measure the ac current in phase with the modulating frequency.

Grunthaner, F. J.↗

Superconducting gravity gradiometer and a test of inverse square law

The equivalence principle prohibits the distinction of gravity from acceleration by a local measurement. However, by making a differential measurement of acceleration over a baseline, platform accelerations can be cancelled and gravity gradients detected. In an in-line superconducting gravity gradiometer, this differencing is accomplished with two spring-mass accelerometers in which the proof masses are confined to motion in a single degree of freedom and are coupled together by superconducting circuits. Platform motions appear as common mode accelerations and are cancelled by adjusting the ratio of two persistent currents in the sensing circuit. The sensing circuit is connected to a commercial SQUID amplifier to sense changes in the persistent currents generated by differential accelerations, i.e., gravity gradients. A three-axis gravity gradiometer is formed by mounting six accelerometers on the faces of a precision cube, with the accelerometers on opposite faces of the cube forming one of three in-line gradiometers. A dedicated satellite mission for mapping the earth's gravity field is an important one. Additional scientific goals are a test of the inverse square law to a part in 10(exp 10) at 100 km, and a test of the Lense-Thirring effect by detecting the relativistic gravity magnetic terms in the gravity gradient tensor for the earth.

Moody, M. V.↗

A dual-amplifier hot-wire anemometer

The conceptual design of a dual-amplifier constant-temperature hot-wire anemometer is described. This hot-wire anemometer consists of three basic independent modules: a Wheatstone bridge in which the hot wire is one of its arms, an error-correction amplifier, and a voltage-controlled current source. The last two modules constitute the feedback network of this hot-wire anemometer. Thus the output voltage across the wire is a true function of the instantaneous changes in the wire resistance induced by the cooling effect of the flow. The dual-amplifier is capable of reaching relatively high frequency response through adequate selection of its active elements. Suitable gain of the error-correction amplifier and proper choice of the transfer function of the current source has yielded a frequency bandwidth up to 200 kHz.

Sadeh, W. Z.↗

Low-cost gradient amplifiers for small MRI systems

Here, we describe low-cost gradient amplifiers for small MRI systems, such as those based on small/medium permanent magnets. The requirements for MRI gradient amplifiers are quite similar to those of modestly priced audio stereo power amplifiers. Such amplifiers for sound service can be modified to be DC coupled, extending their response down to zero frequency, as needed for MRI gradient service. We describe such modifications to one unit (Samson Servo 600) and mention a commercially available modification of another. The 600 is capable of an output greater than ±8 A and ±60 V, much greater than our needs for a greenhouse MRI. Audio amplifiers can be used this way as controlled voltage (CV) gradient amplifiers, with acceptable performance because the gradient coils typically have short L/R time constants. Superior performance can be had by using a controlled current (CC) “front end”; the circuit of our simple front end is included. The complete 3-axis CC system costs about $1200.

47 OTHER INSTRUMENTATION↗

Dual-range linearized transimpedance amplifier system

A transimpedance amplifier system is disclosed which simultaneously generates a low-gain output signal and a high-gain output signal from an input current signal using a single transimpedance amplifier having two different feedback loops with different amplification factors to generate two different output voltage signals. One of the feedback loops includes a resistor, and the other feedback loop includes another resistor in series with one or more diodes. The transimpedance amplifier system includes a signal linearizer to linearize one or both of the low- and high-gain output signals by scaling and adding the two output voltage signals from the transimpedance amplifier. The signal linearizer can be formed either as an analog device using one or two summing amplifiers, or alternately can be formed as a digital device using two analog-to-digital converters and a digital signal processor (e.g. a microprocessor or a computer).

Wessendorf, Kurt O↗

Feedback lock-in: A versatile multi-terminal measurement system for electrical transport devices

Here, we present the design and implementation of a measurement system that enables parallel drive and detection of small currents and voltages at numerous electrical contacts to a multi-terminal electrical device. This system, which we term a feedback lock-in, combines digital control-loop feedback with software-defined lock-in measurements to dynamically source currents and measure small, pre-amplified potentials. The effective input impedance of each current/voltage probe can be set via software, permitting any given contact to behave as an open-circuit voltage lead or as a virtually grounded current source/sink. This enables programmatic switching of measurement configurations and permits measurement of currents at multiple drain contacts without the use of current preamplifiers. Our 32-channel implementation relies on commercially available digital input/output boards, home-built voltage preamplifiers, and custom open-source software. With our feedback lock-in, we demonstrate differential measurement sensitivity comparable to a widely used commercially available lock-in amplifier and perform efficient multi-terminal electrical transport measurements on twisted bilayer graphene and SrTiO 3 quantum point contacts. The feedback lock-in also enables a new style of measurement using multiple current probes, which we demonstrate on a ballistic graphene device.

47 OTHER INSTRUMENTATION↗

Low Noise Amplifier Receivers from Millimeter Wave Atmospheric Remote Sensing

We currently achieve 3.4 dB noise figure at 183GHz and 2.1 dB noise figure at 90 GHz with our MMIC low noise amplifiers (LNAs) in room temperature. These amplifiers and the receivers we have built using them made it possible to conduct highly accurate airborne measurement campaigns from the Global Hawk unmanned aerial vehicle, develop millimeter wave internally calibrated radiometers for altimeter radar path delay correction, and build prototypes of large arrays of millimeter receivers for a geostationary interferometric sounder. We use the developed millimeter wave receivers to measure temperature and humidity profiles in the atmosphere and in hurricanes as well as to characterize the path delay error in ocean topography altimetry.

millimeter wave radiometers↗

Universal signal conditioning amplifier

A state-of-the-art instrumentation amplifier capable of being used with most types of transducers has been developed at the Kennedy Space Center. This Universal Signal Conditioning Amplifier (USCA) can eliminate costly measurement setup item and troubleshooting, improve system reliability and provide more accurate data than conventional amplifiers. The USCA can configure itself for maximum resolution and accuracy based on information read from a RAM chip attached to each transducer. Excitation voltages or current are also automatically configured. The amplifier uses both analog and digital state-of-the-art technology with analog-to-digital conversion performed in the early stages in order to minimize errors introduced by offset and gain drifts in the analog components. A dynamic temperature compensation scheme has been designed to achieve and maintain 12-bit accuracy of the amplifier from 0 to 70 C. The digital signal processing section allows the implementation of digital filters up to 511th order. The amplifier can also perform real-time linearizations up to fourth order while processing data at a rate of 23.438 kS/s. Both digital and analog outputs are available from the amplifier.

Medelius, Pedro J.↗