Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CT Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A machine learning approach to determine the elastic properties of printed fiber-reinforced polymers

This work focuses on the simultaneous determination of the elastic constants and the fiber orientation state for a short fiber-reinforced polymer composite by performing a minimum of experimental tests. Here we introduce a methodology that enables the inverse determination of fiber orientation state and the in-situ polymer properties by performing tensile tests at the composite coupon level. We demonstrate the approach for the extrusion deposition additive manufacturing (EDAM) process to illustrate one application of the methodology, but the development is such that it can be applied to short fiber-reinforced polymer (SFRP) systems processed via other methods. Currently, developing composites additive manufacturing digital twins require extensive material characterization. In particular, the mechanical characterization of the orthotropic elastic properties of a composite involves extensive sample preparation and testing, therefore the elasticity tensor is generally populated using a micromechanics model. This, however, requires measuring the fiber orientation state in addition to knowing the constituent material properties. Experimentally measuring the fiber orientation state can be tedious and time consuming. Further, optical methods are limited to resolving the orientation of cylindrical fibers or cluster of non-cylindrical fibers, and computed tomography (CT) methods scan regions of volume that are much smaller than a full printed bead. Therefore, we propose a methodology, accelerated by machine learning, to identify the anisotropic mechanical properties and fiber orientation state at the same time. Early results show that inference of the fiber orientation and composite properties is possible with as few as three tensile tests. Our results show that a combination of the choice of the micromechanics model and reliable set of experiments can yield the nine elastic constants, as well as, the fiber orientation state.

36 MATERIALS SCIENCE↗

Modeling of multi-component precipitation and crystallization for zero-liquid-discharge desalination

This study proposes novel ZLD treatment trains that integrate multi-component chemical precipitation and multi-effect evaporative crystallization for efficient brine management. The methodology emphasizes sustainability by integrating CO₂ for chemical precipitation and reducing environmental impact, exemplified with two case studies: produced water that includes industrial waste heat utilization by adopting the emerging vacuum air-gapped membrane distillation (VAGMD) technology, and brackish groundwater that is abundant in sulphate which undergoes treatment by low-salt-rejection reverse osmosis (LSRRO) with interstage chemical precipitation. Here, this study is the first of its kind to simultaneously account for reducing risk of mineral scaling and effective recovery of valuable solids when incorporating VAGMD and LSRRO in ZLD treatment trains. Using Reaktoro and WaterTAP, both Python-based, open-source platforms, we model the recovery of high-purity magnesium, calcium, and sodium salts while optimizing energy consumption and operational efficiency in proposed ZLD pathways for case studies of produced water and brackish desalination brine management. Validation with experimental and reference data confirms the reliability of the models used. In both case studies, the optimized ZLD process achieves recovery rates of 97%, 99%, and 90% for Mg, Ca, and Na, with purities exceeding 99%, and brine volume reduced to less than 4% of the initial feed flow.

3D CT scans↗

Coupled Transport, Reactivity, and Mechanics in Fractured Shale Caprocks

Abstract Shales are low‐permeability caprocks that confine fluid, such as CO 2 , nuclear waste, and hydrogen, in storage formations. Stress‐induced fractures in shale caprocks provide pathways for fluid to leak and potentially contaminate fresh water aquifers. Fractured shales are also increasingly considered as resources for CO 2 sequestration, enhanced geothermal, and unconventional energy recovery. Injecting reactive fluids into shales introduces chemical disequilibrium, causing an onset of a series of dissolution, precipitation, and fines mobilization mechanisms. The reactions have rapid kinetics and significant impact on porosity and permeability; consequently, flow and storage properties of caprocks. While previous research has explored the separate effects of these reactions, this study aims to uncover their simultaneous occurrence and collective influence. This study unveils these highly coupled transport and reactivity mechanisms by tracking and visualizing the reaction‐induced alterations in the matrix, microcracks, and fractures of shales over time. We conducted brine injection experiments sequentially at pH 4 and 2 in a naturally fractured Wolfcamp shale sample while simultaneously imaging the dynamic processes using X‐ray computed tomography (CT). CT images are validated by finer resolution images obtained using micro‐CT and scanning electron microscopy. We also tracked the sample permeability and fluid chemistry using brine permeability and inductively coupled plasma mass spectrometry, respectively. Findings show that fluid primarily flowed through fractures, dissolving reactive minerals and mobilizing fines on fracture surfaces. Dissolution of fracture asperities under confining stress resulted in the closing of fractures. Clogging in narrow fracture pathways, caused by fines accumulation, diverted fluid flow into matrix pores.

58 GEOSCIENCES↗

RokBase - Beta

Web based tool and portal to explore and download data associated with Core Characterization Technical Report Series .

Core Characterization↗

Pore-Scale Study on the Positive Feedback Between Stress and Porosity Caused by Pressure Solution in Porous Media

Pressure solution is an important process in the evolution of sedimentary rocks, which provide storage space for most of our petroleum resources. It directly influences the generation, migration, and storage of petroleum fluids in subsurface sedimentary rocks. Here, in this paper, we develop a pore-scale, mechanochemical model to demonstrate a possible positive feedback between the local porosity and pore surface stress, in which a higher local porosity causes a higher local pore surface stress, thus enhancing pressure solution and consequently further increasing the local porosity. Pore surface stress represents stress on a solid grain adjacent to a pore. Specifically, the pore-scale, mechanochemical model directly simulates the stress distribution over solid and pore surfaces using a finite element model. The dissolution of solids at the solid-pore interfaces under a far-from-equilibrium condition is simulated using a first-order kinetics model that accounts for the local stress distribution. The updated pore geometry, caused by pore surface dissolution, is then used in the stress simulation in the next numerical iteration. Two types of porous media, the Oriskany sandstone and an artificial porous medium with spherical pores, were tested in the mechanochemical simulation. The positive stress-porosity feedback during pressure solution was observed in both samples. In addition, the model quantitatively illustrated the distribution of local mineral dissolution rates on all pore surfaces, as well as its relation to the effective mineral dissolution rate of the entire sample. Based on the comparison between the two porous media, the local mineral dissolution was regulated by pore space distribution, geometry, and coalescence during pressure solution. This work is the first that uses direct, pore-scale numerical simulation to demonstrate the positive stress-porosity feedback during pressure solution, which has the potential to advance the understanding of the mechanical-chemical (MC) coupling in many geological processes that are relevant to subsurface energy systems, such as the recovery of petroleum hydrocarbons and geothermal energy.

CT scanning↗

Integration of a Finite Element Model with the DAP Bone Remodeling Model to Characterize Bone Response to Skeletal Loading

NASA's Digital Astronaut Project (DAP) has developed a bone remodeling model that has been validated for predicting volumetric bone mineral density (vBMD) changes of trabecular and cortical bone in the absence of mechanical loading. The model was recently updated to include skeletal loading from exercise and free living activities to maintain healthy bone using a new daily load stimulus (DLS). This new formula was developed based on an extensive review of existing DLS formulas, as discussed in the abstract by Pennline et al. The DLS formula incorporated into the bone remodeling model utilizes strains and stress calculated from finite element model (FEM) of the bone region of interest. The proximal femur was selected for the initial application of the DLS formula, with a specific focus on the femoral neck. METHODS: The FEM was generated from CAD geometry of a femur using de-identified CT data. The femur was meshed using linear tetrahedral elements Figure (1) with higher mesh densities in the femoral neck region, which is the primary region of interest for the initial application of the DLS formula in concert with the DAP bone remodeling model. Nodal loads were applied to the femoral head and the greater trochanter and the base of the femur was held fixed. An L2 norm study was conducted to reduce the length of the femoral shaft without significantly impacting the stresses in the femoral neck. The material properties of the FEM of the proximal femur were separated between cortical and trabecular regions to work with the bone remodeling model. Determining the elements with cortical material properties in the FEM was based off of publicly available CT hip scans [4] that were segmented, cleaned, and overlaid onto the FEM.

Bone Remodeling↗

Orion Exploration Flight Test Post-Flight Inspection and Analysis

The principal mechanism for developing orbital debris environment models, is to make observations of larger pieces of debris in the range of several centimeters and greater using radar and optical techniques. For particles that are smaller than this threshold, breakup and migration models of particles to returned surfaces in lower orbit are relied upon to quantify the flux. This reliance on models to derive spatial densities of particles that are of critical importance to spacecraft make the unique nature of the EFT-1's return surface a valuable metric. To this end detailed post-flight inspections have been performed of the returned EFT-1 backshell, and the inspections identified six candidate impact sites that were not present during the pre-flight inspections. This paper describes the post-flight analysis efforts to characterize the EFT-1 mission craters. This effort included ground based testing to understand small particle impact craters in the thermal protection material, the pre- and post-flight inspection, the crater analysis using optical, X-ray computed tomography (CT) and scanning electron microscope (SEM) techniques, and numerical simulations.

Miller, J. E.↗

X-Ray Micro-Computed Tomography of Apollo Samples as a Curation Technique Enabling Better Research

X-ray micro-computed tomography (micro-CT) is a technique that has been used to research meteorites for some time and many others], and recently it is becoming a more common tool for the curation of meteorites and Apollo samples. Micro-CT is ideally suited to the characterization of astromaterials in the curation process as it can provide textural and compositional information at a small spatial resolution rapidly, nondestructively, and without compromising the cleanliness of the samples (e.g., samples can be scanned sealed in Teflon bags). This data can then inform scientists and curators when making and processing future sample requests for meteorites and Apollo samples. Here we present some preliminary results on micro-CT scans of four Apollo regolith breccias. Methods: Portions of four Apollo samples were used in this study: 14321, 15205, 15405, and 60639. All samples were 8-10 cm in their longest dimension and approximately equant. These samples were micro-CT scanned on the Nikon HMXST 225 System at the Natural History Museum in London. Scans were made at 205-220 kV, 135-160 microamps beam current, with an effective voxel size of 21-44 microns. Results: Initial examination of the data identify a variety of mineral clasts (including sub-voxel FeNi metal grains) and lithic clasts within the regolith breccias. Textural information within some of the lithic clasts was also discernable. Of particular interest was a large basalt clast (approx.1.3 cc) found within sample 60639, which appears to have a sub-ophitic texture. Additionally, internal void space, e.g., fractures and voids, is readily identifiable. Discussion: It is clear from the preliminary data that micro-CT analyses are able to identify important "new" clasts within the Apollo breccias, and better characterize previously described clasts or igneous samples. For example, the 60639 basalt clast was previously believed to be quite small based on its approx.0.5 sq cm exposure on the surface of the main mass. These scans show the clast to be approx.4.5 g, however (assuming a density of approx.3.5 g/cc). This is large enough for detailed studies including multiple geo-chronometers. This basalt clast is of particular interest as it is the largest Apollo 16 basalt, and it is the only mid-TiO2 basalt in the Apollo sample suite. By identifying the location of interesting clasts or grains within a sample, we will be able to make more informed decisions about where to cut a sample in order to best expose clasts of interest for future study. Moreover, knowing the location of internal defects (e.g., fractures) will allow more precise chipping and extraction of clasts or grains. By combining micro-CT scans with compositional techniques like micro x-ray fluorescence (particularly on sawn slabs), we will be able to provide even more comprehensive information to scientists trying to best select samples that fit their scientific needs.

Ziegler, R. A.↗

Convolutional neural network based non-iterative reconstruction for accelerating neutron tomography *

Abstract Neutron computed tomography (NCT), a 3D non-destructive characterization technique, is carried out at nuclear reactor or spallation neutron source-based user facilities. Because neutrons are not severely attenuated by heavy elements and are sensitive to light elements like hydrogen, neutron radiography and computed tomography offer a complementary contrast to x-ray CT conducted at a synchrotron user facility. However, compared to synchrotron x-ray CT, the acquisition time for an NCT scan can be orders of magnitude higher due to lower source flux, low detector efficiency and the need to collect a large number of projection images for a high-quality reconstruction when using conventional algorithms. As a result of the long scan times for NCT, the number and type of experiments that can be conducted at a user facility is severely restricted. Recently, several deep convolutional neural network (DCNN) based algorithms have been introduced in the context of accelerating CT scans that can enable high quality reconstructions from sparse-view data. In this paper, we introduce DCNN algorithms to obtain high-quality reconstructions from sparse-view and low signal-to-noise ratio NCT data-sets thereby enabling accelerated scans. Our method is based on the supervised learning strategy of training a DCNN to map a low-quality reconstruction from sparse-view data to a higher quality reconstruction. Specifically, we evaluate the performance of two popular DCNN architectures—one based on using patches for training and the other on using the full images for training. We observe that both the DCNN architectures offer improvements in performance over classical multi-layer perceptron as well as conventional CT reconstruction algorithms. Our results illustrate that the DCNN can be a powerful tool to obtain high-quality NCT reconstructions from sparse-view data thereby enabling accelerated NCT scans for increasing user-facility throughput or enabling high-resolution time-resolved NCT scans.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibrator Blocks For Computerized Tomography (CT)

Sets of calibrator blocks developed for use with industrial computerized tomography (CT) systems. Set of blocks (or number of stacked sets of blocks) placed on object table of CT system and scanned in usual way. Blocks include holes of known size, shape, and location. Appearance of holes in output image of CT system used to verify operation of system.

Engel, H. Peter↗

X-Ray Computed Tomography Inspection of the Stardust Heat Shield

The "Stardust" heat shield, composed of a PICA (Phenolic Impregnated Carbon Ablator) Thermal Protection System (TPS), bonded to a composite aeroshell, contains important features which chronicle its time in space as well as re-entry. To guide the further study of the Stardust heat shield, NASA reviewed a number of techniques for inspection of the article. The goals of the inspection were: 1) to establish the material characteristics of the shield and shield components, 2) record the dimensions of shield components and assembly as compared with the pre-flight condition, 3) provide flight infonnation for validation and verification of the FIAT ablation code and PICA material property model and 4) through the evaluation of the shield material provide input to future missions which employ similar materials. Industrial X-Ray Computed Tomography (CT) is a 3D inspection technology which can provide infonnation on material integrity, material properties (density) and dimensional measurements of the heat shield components. Computed tomographic volumetric inspections can generate a dimensionally correct, quantitatively accurate volume of the shield assembly. Because of the capabilities offered by X-ray CT, NASA chose to use this method to evaluate the Stardust heat shield. Personnel at NASA Johnson Space Center (JSC) and Lawrence Livermore National Labs (LLNL) recently performed a full scan of the Stardust heat shield using a newly installed X-ray CT system at JSC. This paper briefly discusses the technology used and then presents the following results: 1. CT scans derived dimensions and their comparisons with as-built dimensions anchored with data obtained from samples cut from the heat shield; 2. Measured density variation, char layer thickness, recession and bond line (the adhesive layer between the PICA and the aeroshell) integrity; 3. FIAT predicted recession, density and char layer profiles as well as bondline temperatures Finally suggestions are made as to future uses of this technology as a tool for non-destructively inspecting and verifying both pre and post flight heat shields.

McNamara, Karen M.↗

3D microstructure design of lithium-ion battery electrodes assisted by X-ray nano-computed tomography and modelling

Driving range and fast charge capability of electric vehicles are heavily dependent on the 3D microstructure of lithium-ion batteries (LiBs) and substantial fundamental research is required to optimise electrode design for specific operating conditions. Here we have developed a full microstructure-resolved 3D model using a novel X-ray nano-computed tomography (CT) dual-scan superimposition technique that captures features of the carbon-binder domain. This elucidates how LiB performance is markedly affected by microstructural heterogeneities, particularly under high rate conditions. The elongated shape and wide size distribution of the active particles not only affect the lithium-ion transport but also lead to a heterogeneous current distribution and non-uniform lithiation between particles and along the through-thickness direction. Building on these insights, we propose and compare potential graded-microstructure designs for next-generation battery electrodes. To guide manufacturing of electrode architectures, in-situ X-ray CT is shown to reliably reveal the porosity and tortuosity changes with incremental calendering steps.

33 ADVANCED PROPULSION SYSTEMS↗

Different CT slice thickness and contrast‐enhancement phase in radiomics models on the differential performance of lung adenocarcinoma

Abstract Background To investigate the effects of computed tomography (CT) reconstruction slice thickness and contrast‐enhancement phase on the differential diagnosis performance of radiomic signature in lung adenocarcinoma. Methods A total of 187 patients who had been pathologically confirmed with lung adenocarcinoma and nonadenocarcinoma were divided into a training cohort ( n = 149) and validation cohort ( n = 38). All the patients underwent contrast‐enhanced CT and the images were reconstructed with different slice thickness. The radiomic features were extracted from different slice thickness and scan phase. The logistic regression (LR) algorithm was used to build a machine learning model for each group. The area under the curve (AUC) obtained from the receiver operating characteristic (ROC) curve and DeLong test was used to evaluate its discriminating performance. Results Finally, 34 image features and five semantic features were selected to establish a radiomics model. Based on the three contrast‐enhanced CT phases and four reconstruction slice thickness, 12 groups of radiomics models showed good discrimination ability with the AUCs range from 0.9287 to 0.9631, sensitivity range from 0.8349 to 0.9083, specificity range from 0.825 to 0.925 in the training group. Similar results were observed in the validation group. However, there was no statistical significance between the different CT scan phase groups and different slice thickness ( p > 0.05). Conclusions The radiomic analysis of contrast‐enhanced CT can be used for the differential diagnosis of lung adenocarcinoma. Moreover, different slice thickness and contrast‐enhanced scan phase did not affect the discriminating ability in the radiomics models.

Wang, Yang↗

NASA Robotic Neurosurgery Testbed

The detection of tissue interface (e.g., normal tissue, cancer, tumor) has been limited clinically to tactile feedback, temperature monitoring, and the use of a miniature ultrasound probe for tissue differentiation during surgical operations. In neurosurgery, the needle used in the standard stereotactic CT (Computational Tomography) or MRI (Magnetic Resonance Imaging) guided brain biopsy provides no information about the tissue being sampled. The tissue sampled depends entirely upon the accuracy with which the localization provided by the preoperative CT or MRI scan is translated to the intracranial biopsy site. In addition, no information about the tissue being traversed by the needle (e.g., a blood vessel) is provided. Hemorrhage due to the biopsy needle tearing a blood vessel within the brain is the most devastating complication of stereotactic CT/MRI guided brain biopsy. A robotic neurosurgery testbed has been developed at NASA Ames Research Center as a spin-off of technologies from space, aeronautics and medical programs. The invention entitled 'Robotic Neurosurgery Leading to Multimodality Devices for Tissue Identification' is nearing a state ready for commercialization. The devices will: 1) improve diagnostic accuracy and precision of general surgery, with near term emphasis on stereotactic brain biopsy, 2) automate tissue identification, with near term emphasis on stereotactic brain biopsy, to permit remote control of the procedure, and 3) reduce morbidity for stereotactic brain biopsy. The commercial impact from this work is the potential development of a whole new generation of smart surgical tools to increase the safety, accuracy and efficiency of surgical procedures. Other potential markets include smart surgical tools for tumor ablation in neurosurgery, general exploratory surgery, prostate cancer surgery, and breast cancer surgery.

Mah, Robert↗

NASA Robotic Neurosurgery Testbed

The detection of tissue interface (e.g., normal tissue, cancer, tumor) has been limited clinically to tactile feedback, temperature monitoring, and the use of a miniature ultrasound probe for tissue differentiation during surgical operations, In neurosurgery, the needle used in the standard stereotactic CT or MRI guided brain biopsy provides no information about the tissue being sampled. The tissue sampled depends entirely upon the accuracy with which the localization provided by the preoperative CT or MRI scan is translated to the intracranial biopsy site. In addition, no information about the tissue being traversed by the needle (e.g., a blood vessel) is provided. Hemorrhage due to the biopsy needle tearing a blood vessel within the brain is the most devastating complication of stereotactic CT/MRI guided brain biopsy. A robotic neurosurgery testbed has been developed at NASA Ames Research Center as a spin-off of technologies from space, aeronautics and medical programs. The invention entitled "Robotic Neurosurgery Leading to Multimodality Devices for Tissue Identification" is nearing a state ready for commercialization. The devices will: 1) improve diagnostic accuracy and precision of general surgery, with near term emphasis on stereotactic brain biopsy, 2) automate tissue identification, with near term emphasis on stereotactic brain biopsy, to permit remote control of the procedure, and 3) reduce morbidity for stereotactic brain biopsy. The commercial impact from this work is the potential development of a whole new generation of smart surgical tools to increase the safety, accuracy and efficiency of surgical procedures. Other potential markets include smart surgical tools for tumor ablation in neurosurgery, general exploratory surgery, prostate cancer surgery, and breast cancer surgery.

Mah, Robert↗

Method and Apparatus for Virtual Interactive Medical Imaging by Multiple Remotely-Located Users

A virtual interactive imaging system allows the displaying of high-resolution, three-dimensional images of medical data to a user and allows the user to manipulate the images, including rotation of images in any of various axes. The system includes a mesh component that generates a mesh to represent a surface of an anatomical object, based on a set of data of the object, such as from a CT or MRI scan or the like. The mesh is generated so as to avoid tears, or holes, in the mesh, providing very high-quality representations of topographical features of the object, particularly at high- resolution. The system further includes a virtual surgical cutting tool that enables the user to simulate the removal of a piece or layer of a displayed object, such as a piece of skin or bone, view the interior of the object, manipulate the removed piece, and reattach the removed piece if desired. The system further includes a virtual collaborative clinic component, which allows the users of multiple, remotely-located computer systems to collaboratively and simultaneously view and manipulate the high-resolution, three-dimensional images of the object in real-time.

Ross, Muriel D.↗