Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONDENSATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

SUBSTELLAR-MASS CONDENSATIONS IN PRESTELLAR CORES

We present combined Submillimeter Array and single-dish images of the (sub)millimeter dust continuum emission toward two prestellar cores, SM1 and B2-N5, in the nearest star-cluster-forming region, {rho} Ophiuchus. Our combined images indicate that SM1 and B2-N5 consist of three and four condensations, respectively, with masses of 10{sup -2}-10{sup -1} M{sub Sun} and sizes of a few hundred AU. The individual condensations have mean densities of 10{sup 8}-10{sup 9} cm{sup -3} and the masses are comparable to or larger than the critical Bonner-Ebert mass, indicating that self-gravity plays an important role in the dynamical evolution of the condensations. The coalescence timescale of these condensations is estimated to be about 10{sup 4} yr, which is comparable to the local gravitational collapse timescale, suggesting that merging of the condensations, instead of accretion, plays an essential role in the star formation process. These results challenge the standard theory of star formation, where a single, rather featureless, prestellar core collapses to form at most a couple of condensations, each of which potentially evolves into a protostar that is surrounded by a rotating disk where planets are created.

79 ASTRONOMY AND ASTROPHYSICS↗

Why double-stranded RNA resists condensation

The addition of small amounts of multivalent cations to solutions containing double-stranded DNA leads to attraction between the negatively charged helices and eventually to condensation. Surprisingly, this effect is suppressed in double-stranded RNA, which carries the same charge as the DNA, but assumes a different double helical form. However, additional characterization of short (25 base-pairs) nucleic acid (NA) duplex structures by circular dichroism shows that measured differences in condensation are not solely determined by duplex helical geometry. Here we combine experiment, theory, and atomistic simulations to propose a mechanism that connects the observed variations in condensation of short NA duplexes with the spatial variation of cobalt hexammine (CoHex) binding at the NA duplex surface. The atomistic picture that emerged showed that CoHex distributions around the NA reveals two major NA-CoHex binding modes -- internal and external -- distinguished by the proximity of bound CoHex to the helical axis. Decreasing trends in experimentally observed condensation propensity of the four studied NA duplexes (from B-like form of homopolymeric DNA, to mixed sequence DNA, to DNA:RNA hybrid, to A-like RNA) are explained by the progressive decrease of a single quantity: the fraction of CoHex ions in the external binding mode. Thus, while NA condensation depends on a complex interplay between various structural and sequence features, our coupled experimental and theoretical results suggest a new model in which a single parameter connects the NA condensation propensity with geometry and sequence dependence of CoHex binding.

ELECTROSTATICS↗

Relaxation times for Bose-Einstein condensation in axion miniclusters

We study the Bose condensation of scalar dark matter in the presence of both gravitational and self-interactions. Axions and other scalar dark matter in gravitationally bound miniclusters or dark matter halos are expected to condense into Bose-Einstein condensates called Bose stars. This process has been shown to occur through attractive self-interactions of the axionlike particles or through the field’s self gravitation. We show that in the high-occupancy regime of scalar dark matter, the Boltzmann collision integral does not describe either gravitational or self-interactions, and derive kinetic equations valid for these interactions. We use this formalism to compute relaxation times for the Bose-Einstein condensation, and find that condensation into Bose stars could occur within the lifetime of the Universe. The self-interactions reduce the condensation time only when they are very strong.

79 ASTRONOMY AND ASTROPHYSICS↗

Kinetic frustration by limited bond availability controls the LAT protein condensation phase transition on membranes

LAT is a membrane-linked scaffold protein that undergoes a phase transition to form a two-dimensional protein condensate on the membrane during T cell activation. Governed by tyrosine phosphorylation, LAT recruits various proteins that ultimately enable condensation through a percolation network of discrete and selective protein-protein interactions. Here, we describe detailed kinetic measurements of the phase transition, along with coarse-grained model simulations, that reveal that LAT condensation is kinetically frustrated by the availability of bonds to form the network. Unlike typical miscibility transitions in which compact domains may coexist at equilibrium, the LAT condensates are dynamically arrested in extended states, kinetically trapped out of equilibrium. Modeling identifies the structural basis for this kinetic arrest as the formation of spindle arrangements, favored by limited multivalent binding interactions along the flexible, intrinsically disordered LAT protein. These results reveal how local factors controlling the kinetics of LAT condensation enable formation of different, stable condensates, which may ultimately coexist within the cell.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Amphiphilic nanopores that condense undersaturated water vapor and exude water droplets

Condensation of water vapor in confined geometries, known as capillary condensation, is a fundamental phenomenon with far-reaching implications. While hydrophilic pores enable liquid formation from undersaturated vapor without energy input, the condensate typically remains confined, limiting practical utility. Here, we explore the use of amphiphilic nanoporous polymer-infiltrated nanoparticle films that condense and release liquid water under isothermal and undersaturated conditions. By tuning the polymer fraction and nanoparticle size, we optimize condensation and droplet formation. As vapor pressure increases, voids fill with condensate, which subsequently exudes onto the surface as microscopic droplets. This behavior, enabled by a balance of polymer hydrophobicity and capillarity, reveals how amphiphilic nanostructures can drive accessible water collection. Our findings provide design insights for materials supporting energy-efficient water harvesting and heat management without external input.

Science & Technology - Other Topics↗

A new approach of microbiome monitoring in the built environment: feasibility analysis of condensation capture

Background: Humans emit approximately 30 million microbial cells per hour into their immediate vicinity. However, sampling of aerosolized microbial taxa (aerobiome) remains largely uncharacterized due to the complexity and limitations of sampling techniques, which are highly susceptible to low biomass and rapid sample degradation. Recently, there has been an interest in developing technology that collects naturally occurring water from the atmosphere, even within the built environment. Here, we analyze the feasibility of indoor aerosol condensation collection as a method to capture and analyze the aerobiome. Methods: Aerosols were collected via condensation or active impingement in a laboratory setting over the course of 8 h. Microbial DNA was extracted from collected samples and sequenced (16S rRNA) to analyze microbial diversity and community composition. Dimensional reduction and multivariate statistics were employed to identify significant (p < 0.05) differences in relative abundances of specific microbial taxa observed between the two sampling platforms. Results: Aerosol condensation capture is highly efficient with a yield greater than 95% when compared to expected values. Compared to air impingement, aerosol condensation showed no significant difference (ANOVA, p > 0.05) in microbial diversity. Among identified taxa, Streptophyta and Pseudomonadales comprised approximately 70% of the microbial community composition. Conclusion: The results suggest that condensation of atmospheric humidity is a suitable method for the capture of airborne microbial taxa reflected by microbial community similarity between devices. Future investigation of aerosol condensation may provide insight into the efficacy and viability of this new tool to investigate airborne microorganisms.

59 BASIC BIOLOGICAL SCIENCES↗

AP-105 Melter Offgas Condensate and EMF Evaporator Concentrate Raman and LIBS Qualitative Evaluation for the use of In-Line Monitoring (Rev. 0)

The Pacific Northwest National Laboratory (PNNL) was tasked to perform Raman spectroscopy and laser induced breakdown spectroscopy (LIBS) testing on the melter off-gas condensate generated during low-activity waste process testing of a sample from Hanford Site tank AP-105 and/or evaporate from evaporation of the condensate. This was a proof-of-principle demonstration that Raman spectroscopy and LIBS have the potential to be used as analytical tools for in-line process analysis of key aqueous phase analytes in radioactive process streams associated with the Hanford Waste Treatment and Immobilization Plant. The work completed under this project complements work completed for WRPS with the development of in-line monitoring systems to characterize and quantify constituents of tank waste following Cs removal and filtration. The WRPS work is currently limited to Raman sensors and utilizes chemometric models for quantification of several anionic species in the sample system. It should be noted that while this approach can be applied to off-gas condensate streams, new chemometric models are needed to accurately quantify analytes under off-gas condensate conditions. The work completed under this project makes timely use of available samples and equipment at PNNL. The project utilized the opportunity to collect off-gas samples from planned AP-105 processing work and included the direct condensate and the evaporate from the DFLAW Radioactive Waste Test Platform. Samples were characterized by instruments already in place at PNNL including a Raman spectrometer optimized for in-line monitoring of flowing and stationary samples as well as a LIBS instrument, which was optimized for static liquid droplet analysis. The ultimate objective was to determine if these techniques could be used to qualitatively characterize analytes present within the off-gas samples. The testing confirmed the use of the Raman as an in-line monitoring system was able to qualitatively observe NO 3 - , NO 2 - , aluminum (as aluminate, Al(OH) 4 - ), SO 4 2- , CrO 4 2- , CO 3 2- , and PO 4 3- in the AP-105 melter feed evaporator condensate samples. The testing also confirmed LIBS as a potential useful technique for in-line monitoring, able to qualitatively detect Na, N, Al, and tentatively Cr and Cl in a simulant stock evaporate solution.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Capillary-driven Condensation for Heat Transfer Enhancement in Steam Power Plants

A novel condensation method was developed to enhance the efficiency of steam power plants. The method consists of a hierarchical structure on the surface of condenser tubes consisting of a wicking structure overlaid with a porous hydrophobic membrane. The project is divided into two main efforts. First, a structure with highly defined geometry was made utilizing microfabrication on silicon. This structure helped us elucidate the physics of steam condensation at the surface, more easily model the heat transfer coefficient, and demonstrate the first proof-of-concept for our proposed condensation approach. The structures on silicon achieved a heat transfer coefficient ~ 240% higher than the theoretical filmwise value at the same operating condition. Second, the method is explored for scalability by fabricating surfaces with industrial class materials followed by heat transfer measurements on flat surfaces. An HTC enhancement of 50% over the experimental filmwise value was achieved on hierarchical copper surfaces made of commercially available copper foams and meshes, showing the potential of achieving heat transfer enhancement using low cost and scalable materials. Scalable fabrication of the hydrophobic membrane and the porous copper wick were also investigated. Our heat and mass transfer model predicts a > 5x heat transfer enhancement on a scalable version of capillary driven condenser made of membrane covered porous copper. The results demonstrate the promise of capillary-driven condensation surfaces for heat transfer applications.

20 FOSSIL-FUELED POWER PLANTS↗

Performance Evaluation of Low-Cost Condensers Immersed in the Water Tank of a Heat Pump Water Heater

This paper reports the effect of low-cost immersed condensers on the performance of a heat pump water heater (HPWH) that does not require a water-circulating pump. The proposed design is based on the immersion of an L-style condenser coil through an opening in the top of the water tank. The novel design aims to eliminate the need for the water-circulating pumps, thereby substantially improving efficiency and reducing costs and maintenance of the HPWH system. Comprehensive computational fluid dynamics (CFD) simulations and experimental tests were performed, and the results showed that the CFD simulations were close to the experimental data. Further results confirm that the L-style condenser can introduce buoyancy-driven flow and eliminate temperature stratification in the studied HPWH water tank, thereby improving the heat transfer coefficient and coefficient of performance of the HPWH. The testing results further showed that the L-style condenser enabled more than 53% higher coefficient of performance and 400% higher heat transfer coefficient compared with the straight vertical condenser, and achieved much faster water heating. Furthermore, the effects of immersed condensers with different circuits on the HPWH performance were evaluated and compared. All results indicate that the current energy-saving and inexpensive HPWH technology is technically valid, and the benefits of performance improvement and low cost are attractive in future HPWH design.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

Disequilibrium condensation environments in space - A frontier in thermodynamics

The thermal-disequilibrium aspect of the problem of dust-particle formation from a gas phase in an open space environment is discussed in an effort to draw attention to the space condensation environment as an interesting arena for application and extension of the ideas and formalisms of nonequilibrium thermodynamics. It is shown that quasi-steady states with a disequilibrium between the gas-phase kinetic temperature and the condensed-phase internal temperature appear to be the norm of condensation environments in space. Consideration of the case of condensation onto a bulk condensed phase indicates that these quasi-steady states may constitute Prigogine dissipative structures. It is suggested that a proper study of the process of condensation in a space environment should include any effects arising from thermal disequilibrium.

De, B. R.↗

Development of a condenser for the dual catalyst water recovery system

Conceptual evaporation/condensation systems suitable for integration with the catalytic water recovery method were evaluated. The primary requirements for each concept were its capability to operate under zero-gravity conditions, condense recovered water from a vapor-noncondensable gas mixture, and integrate with the catalytic system. Specific energy requirements were estimated for concepts meeting the primary requirements, and the concept most suitable for integration with the catalytic system was proposed. A three-man rate condenser capable of integration with the proposed system, condensing water vapor in presence of noncondensables and transferring the heat of condensation to feed urine was designed, fabricated, and tested. It was treated with steam/air mixtures at atmospheric and elevated pressures and integrated with an actual catalytic water recovery system. The condenser has a condensation efficiency exceeding 90% and heat transfer rate of approximately 85% of theoretical value at coolant temperature ranging from 7 to 80 deg C.

Budinikas, P.↗

Condensation modes in sheared magnetic fields

The present study of the condensation modes in coronal cylindrical plasmas, with attention to magnetic shear effects on stability, notes that such shear is insignificant in the initiation of condensation in the case of low beta coronal plasmas. The effects of magnetic field shear, twist, and strength on condensation modes differ, depending on the wave vector. The stability of condensation modes strongly depends on the choice of equilibrium temperature and density profiles. If plasma temperature increases with twist but density does not, condensation modes are unstable for low field twist; by contrast, if plasma density increases with twist but temperature does not, condensation modes are unstable for high twist.

An, C.-H.↗

Study of toluene rotary fluid management device and shear flow condenser performance for a space-based organic Rankine power system

Management of two-phase fluid and control of the heat transfer process in microgravity is a technical challenge that must be addressed for an orbital Organic Rankine Cycle (ORC) application. A test program was performed in 1-g that satisfactorily demonstrated the two-phase management capability of the rotating fluid management device (RFMD) and shear-flow condenser. Operational tests of the RFMD and shear flow condenser in adverse gravity orientations, confirmed that the centrifugal forces in the RFMD and the shear forces in the condenser were capable of overcoming gravity forces. In a microgravity environment, these same forces would not have to compete against gravity and would therefore be dominant. The specific test program covered the required operating range of the Space Station Solar Dynamic Rankine Cycle power system. Review of the test data verified that: fluid was pumped from the RFMD in all attitudes; subcooled states in the condenser were achieved; condensate was pushed uphill against gravity; and noncondensible gases were swept through the condenser.

Havens, Vance↗

Mathematical Modeling of Loop Heat Pipes with Multiple Capillary Pumps and Multiple Condensers: Stead State Stimulations - Part 1

Loop Heat Pipes (LHPs) have proven themselves as reliable and robust heat transport devices for spacecraft thermal control systems. So far, the LHPs in earth-orbit satellites perform very well as expected. Conventional LHPs usually consist of a single capillary pump for heat acquisition and a single condenser for heat rejection. Multiple pump/multiple condenser LHPs have shown to function very well in ground testing. Nevertheless, the test results of a dual pump/condenser LHP also revealed that the dual LHP behaved in a complicated manner due to the interaction between the pumps and condensers. Thus it is redundant to say that more research is needed before they are ready for 0-g deployment. One research area that perhaps compels immediate attention is the analytical modeling of LHPs, particularly the transient phenomena. Modeling a single pump/single condenser LHP is difficult enough. Only a handful of computer codes are available for both steady state and transient simulations of conventional LHPs. No previous effort was made to develop an analytical model (or even a complete theory) to predict the operational behavior of the multiple pump/multiple condenser LHP systems. The current research project offered a basic theory of the multiple pump/multiple condenser LHP operation. From it, a computer code was developed to predict the LHP saturation temperature in accordance with the system operating and environmental conditions.

Hoang, Triem T.↗

Calculated Condenser Performance for a Mercury-Turbine Power Plant for Aircraft

As part of an investigation af the application of nuclear energy to various types of power plants for aircraft, calculations have been made to determine the effect of several operating conditions on the performance of condensers for mercury-turbine power plants. The analysis covered 8 range of turbine-outlet pressures from 1 to 200 pounds per square inch absolute, turbine-inlet pressures from 300 to 700 pounds per square inch absolute,and a range of condenser cooling-air pressure drops, airplane flight speeds, and altitudes. The maximum load-carrying capacity (available for the nuclear reactor, working fluid, and cargo) of a mercury-turbine powered aircraft would be about half the gross weight of the airplane at a flight speed of 509 miles per hour and an altitude of 30,000 feet. This maximum is obtained with specific condenser frontal areas of 0.0063 square foot per net thrust horsepower with the condenser in a nacelle and 0.0060 square foot per net thrust horsepower with the condenser submerged in the wings (no external condenser drag) for a turbine-inlet pressure of 500 pounds per square inch absolute, a turbine-outlet pressure of 10 pounds per square inch absolute, and 8 turbine-inlet temperature of 1600 F.

Doyle, Ronald B.↗

Bio-oil fractionation and condensation

A method of fractionating bio-oil vapors which involves providing bio-oil vapors comprising bio-oil constituents is described. The bio-oil vapors are cooled in a first stage which comprises a condenser having passages for the bio-oil separated by a heat conducting wall from passages for a coolant. The coolant in the condenser of the first stage is maintained at a substantially constant temperature, set at a temperature in the range of 75 to 100.degree. C., to condense a first liquid fraction of liquefied bio-oil constituents in the condenser of the first stage. The first liquid fraction of liquified bio-oil constituents from the condenser in the first stage is collected. Also described are steps for subsequently recovering further liquid fractions of liquefied bio-oil constituents. Particular compositions of bio-oil condensation products are also described.

Brown, Robert C↗

Bio-oil fractionation and condensation

The present invention relates to a method of fractionating bio-oil vapors which involves providing bio-oil vapors comprising bio-oil constituents. The bio-oil vapors are cooled in a first stage which comprises a condenser having passages for the bio-oil separated by a heat conducting wall from passages for a coolant. The coolant in the condenser of the first stage is maintained at a substantially constant temperature, set at a temperature in the range of 75 to 100.degree. C., to condense a first liquid fraction of liquefied bio-oil constituents in the condenser of the first stage. The first liquid fraction of liquified bio-oil constituents from the condenser in the first stage is collected. Also disclosed are steps for subsequently recovering further liquid fractions of liquefied bio-oil constituents. Particular compositions of bio-oil condensation products are also described.

09 BIOMASS FUELS↗

Lift-off patterning processes employing energetically-stimulated local removal of solid-condensed-gas layers

The invention provides a method for forming a patterned material layer on a structure, by condensing a vapor to a solid condensate layer on a surface of the structure and then localized removal of selected regions of the condensate layer by directing an ion beam at the selected regions, exposing the structure at the selected regions. A material layer is then deposited on top of the solid condensate layer and the exposed structure at the selected regions. Then the solid condensate layer and regions of the material layer that were deposited on the solid condensate layer are removed, leaving a patterned material layer on the structure.

Branton, Daniel↗