Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CHROMATOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

IgY14 and SuperMix immunoaffinity separations coupled with liquid chromatography-mass spectrometry for human plasma proteomic biomarker discovery

Interest in the application of advanced proteomics technologies to human blood plasma- or serum-based clinical samples for the purpose of discovering disease biomarkers continues to grow; however, the enormous dynamic range of protein concentrations in these types of samples (often >10 orders of magnitude) represents a significant analytical challenge, particularly for detecting low-abundance candidate biomarkers. In response, immunoaffinity separation methods for depleting multiple high- and moderate-abundance proteins have become key tools for enriching low-abundance proteins and enhancing detection of these proteins in plasma proteomics. Herein, we describe IgY14 and tandem IgY14-Supermix separation methods for removing 14 high-abundance and up to 60 moderate-abundance proteins, respectively, from human blood plasma and highlight their utility when combined with liquid chromatography-tandem mass spectrometry for interrogating the human plasma proteome.

59 BASIC BIOLOGICAL SCIENCES↗

Combining Laser Ablation/Liquid Phase Collection Surface Sampling and High-Performance Liquid Chromatography Electrospray Ionization Mass Spectrometry

This paper describes the coupling of ambient pressure transmission geometry laser ablation with a liquid phase sample collection method for surface sampling and ionization with subsequent mass spectral analysis. A commercially available autosampler was adapted to produce a liquid droplet at the end of the syringe injection needle while in close proximity to the surface to collect the sample plume produced by laser ablation. The sample collection was followed by either flow injection or a high performance liquid chromatography (HPLC) separation of the extracted components and detection with electrospray ionization mass spectrometry (ESI-MS). To illustrate the analytical utility of this coupling, thin films of a commercial ink sample containing rhodamine 6G and of mixed isobaric rhodamine B and 6G dyes on glass microscope slides were analyzed. The flow injection and HPLC/ESI-MS analysis revealed successful laser ablation, capture and, with HPLC, the separation of the two compounds. The ablated circular area was about 70 m in diameter for these experiments. The spatial sampling resolution afforded by the laser ablation, as well as the ability to use sample processing methods like HPLC between the sample collection and ionization steps, makes this combined surface sampling/ionization technique a highly versatile analytical tool.

Laser Ablation↗

Binary Electroosmotic-Pump Nanoflow Gradient Generator for Miniaturized High-Performance Liquid Chromatography

High-performance liquid chromatography (HPLC) plays an important role in biotechnology, and a majority of chromatographic separations use gradient elution. While gradient generators can be built in different formats, binary pumps or quaternary pumps are most frequently used for gradient generator constructions. We have recently developed a high-pressure electroosmotic pump (EOP); the pump can be manufactured at a cost of a few hundred dollars. However, it is challenging to use this pump to deliver a gradient eluent directly. In this study, we first improve the monolith preparation by applying a pressure to the monomer solution during polymerization. We assemble a binary EOP gradient generator and discuss the relationship between the gradient profile and voltage applied to the EOP. Here we demonstrate the feasibility of the binary EOP gradient generator for generating a smooth and reproducible nanoflow gradient. After integration of the gradient generator into a miniaturized HPLC system, we use the HPLC system for separating peptide mixtures from trypsin-digested proteins. Lastly, the performance comparison between the above miniaturized HPLC system and an Agilent 1200 HPLC system exhibits comparable efficiencies, resolutions, and peak capacities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Avoiding Misannotation of In-Source Fragmentation Products as Cellular Metabolites in Liquid Chromatography–Mass Spectrometry-Based Metabolomics

Liquid chromatography–mass spectrometry (LC-MS) technology allows for rapid quantitation of cellular metabolites, with metabolites identified by mass spectrometry and chromatographic retention time. Recently, with the development of rapid scanning high-resolution high accuracy mass spectrometers and the desire for high throughput screening, minimal or no chromatographic separation has become increasingly popular. Furthermore, when analyzing complex cellular extracts, however, the lack of chromatographic separation could potentially result in misannotation of structurally related metabolites. Here, we show that, even using electrospray ionization, a soft ionization method, in-source fragmentation generates unwanted byproducts of identical mass to common metabolites. For example, nucleotide-triphosphates generate nucleotide-diphosphates, and hexose-phosphates generate triose-phosphates. We also evaluated yeast intracellular metabolite extracts and found more than 20 cases of in-source fragments that mimic common metabolites. Finally and accordingly, chromatographic separation is required for accurate quantitation of many common cellular metabolites.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tile-Based Fisher Ratio Analysis of Comprehensive Two-Dimensional Gas Chromatography Time-of-Flight Mass Spectrometry (GC × GC – TOFMS) Data using a Null Distribution Approach

Multi-dimensional chromatographic instrumentation produces information-rich, and chemically complex data containing meaningful chemical signals and/or chemical patterns. Two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (GC × GC – TOFMS) is a prominent instrumental platform that has been applied extensively for discovery-based experimentation, where samples are sufficiently volatile or amenable to derivatization. Use of GC × GC – TOFMS and associated data analysis strategies aim to uncover meaningful chemical signals or chemical patterns. However, for complex samples, meaningful chemical information is often buried in a background of less meaningful chemical signal and noise. In this report, we utilize the tile-based F-ratio software in concert with the standard addition method by spiking non-native chemicals into a diesel fuel matrix at low concentrations. While the previous work studied the concentration range of 100-1000 ppm, the current study focuses on the 0 ppm to 100 ppm analyte spike range. This study demonstrates the sensitivity and selectivity of the tile-based F-ratio software for discovery of true positives in the non-targeted analysis of a chemically complex and analytically challenging sample matrix. By exploring the low concentration spike levels, we gain a better understanding of the limit of detection (LOD) of the tile-based F-ratio software with GC × GC – TOFMS data.

Parsons, Brendon A.↗

Mapping glyceride species in biodiesel by high-temperature gas chromatography combined with chemical ionization mass spectrometry.

Accurate and comprehensive identification of residual glycerides in biodiesel is an important part of the fuel characterization, due to the impact of glycerides on the fuel physicochemical properties. However, analysis of bound glycerol in biodiesel samples faces challenges due to lack of readily available standards of structurally complex glyceride species in non-traditional biodiesel feedstocks, and a risk of misannotation in the presence of impurities in gas chromatographic separations. Here we evaluate methane and isobutane chemical ionization – single quadrupole mass spectrometry combined with high temperature gas chromatography separations for mapping monoacylglycerols, diacylglycerols and triacylglycerols in biodiesel. Unlike the electron impact ionization which produces mostly in-source fragments, isobutane chemical ionization spectra of tetramethylsilyl (TMS) derivatized monoacylglycerols and diacylglycerols are dominated by molecular ions and M-SiO(CH3)3+ ions, which provide important diagnostic information. We demonstrate the utility of isobutane chemical ionization in identifying structurally complex glycerolipid standards as well as species in biodiesel samples from different plant and animal feedstocks.

biodiesel, chemcial ionization mass spectrometry↗

Quantitative Separation of Unknown Organic–Metal Complexes by Liquid Chromatography–Inductively Coupled Plasma-Mass Spectrometry

Dissolved organic matter (DOM) is widely recognized to control the solubility and reactivity of trace metals in the environment. However, the mechanisms that govern metal-DOM complexation remain elusive, primarily due to the analytical challenge of fractionating and quantifying metal–organic species within the complex mixture of organic compounds that comprise DOM. Here, we describe a quantitative method for fractionation and element-specific detection of organic–metal complexes using liquid chromatography with online inductively coupled plasma mass spectrometry (LC–ICP-MS). The method implements a post-column compensation gradient to stabilize ICP–MS elemental response across the LC solvent gradient, thereby overcoming a major barrier to achieving quantitative accuracy with LC–ICP-MS. With external calibration and internal standard correction, the method yields concentrations of organic–metal complexes that were consistently within 6% of their true values, regardless of the complex’s elution time. We used the method to evaluate the effects of four stationary phases (C18, phenyl, amide, and pentafluoroylphenyl propyl) on the recovery and separation of environmentally relevant trace metals (Mn, Fe, Co, Ni, Cu, Zn, Cd, and Pb) in Suwannee River Fulvic Acid and Suwannee River Natural Organic Matter. The C18, amide, and phenyl phases generally yielded optimal metal recoveries (>75% for all metals except Pb), with the phenyl phase separating polar species to a greater extent than C18 or amide. We also fractionated organic-bound Fe, Cu, and Ni in oxidized and reduced soils, revealing divergent metal-DOM speciation across soil redox environments. Finally, by enabling quantitative fractionation of DOM-bound metals, our method offers a means for advancing a mechanistic understanding of metal–organic complexation throughout the environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved Characterization of Soil Organic Matter by Integrating FT-ICR MS, Liquid Chromatography Tandem Mass Spectrometry, and Molecular Networking: A Case Study of Root Litter Decay under Drought Conditions

Understanding of how soil organic matter (SOM) chemistry is altered in a changing climate has advanced considerably; however, most SOM components remain unidentified, impeding the ability to characterize a major fraction of organic matter and predict what types of molecules, and from which sources, will persist in soil. Here we present a novel approach to better characterize SOM extracts by integrating information from three types of analyses, and we deploy this method to characterize decaying root-detritus soil microcosms subjected to either drought or normal conditions. To observe broad differences in composition, we employed direct infusion Fourier-transform ion cyclotron resonance mass spectrometry (DI-FT-ICR MS). We complemented this with liquid chromatography tandem mass spectrometry (LC-MS/MS) to identify components by library matching. Since libraries contain only a small fraction of SOM components, we also used fragment spectral cosine similarity scores to relate unknowns and library matches through molecular networks. This integrated approach allowed us to corroborate DI-FT-ICR MS molecular formulas using library matches, which included fungal metabolites and related polyphenolic compounds. We also inferred structures of unknowns from molecular networks and improved LC-MS/MS annotation rates from ~5 to 35% by considering DI-FT-ICR MS molecular formula assignments. Under drought conditions, we found greater relative amounts of lignin-like vs condensed aromatic polyphenol formulas and lower average nominal oxidation state of carbon, suggesting reduced decomposition of SOM and/or microbes under stress. Our integrated approach provides a framework for enhanced annotation of SOM components that is more comprehensive than performing individual data analyses in parallel.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using Receiver Operating Characteristic Curves to Optimize Discovery-Based Software with Comprehensive Two-Dimensional Gas Chromatography with Time-of-Flight Mass Spectrometry

We report a quantitative approach to optimize implementation of discovery-based software for comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (GC × GC – TOFMS). The software performs a tile-based Fisher ratio (F-ratio) analysis, and facilitates a supervised non-targeted analysis based upon the experimental design to aid in the discovery of analytes whose variances are statistically different between sample classes. The quantitative approach for software optimization uses receiver operating characteristic (ROC) curves. The area under the curve (AUC) of each ROC curve serves as a quantitative metric to optimize two key algorithm parameters: the signal-to-noise ratio (S/N) threshold of the baseline corrected and normalized data prior to calculating F-ratios at each m/z mass channel, and the number of these F-ratios per m/z to include in the calculation of the average F-ratio of a tile. A total of 25 combinations of S/N threshold by number of m/z were studied. Fifty analytes were spiked into a diesel fuel at two concentration spike levels to produce two sample classes that should in principle produce 50 positive instances in the ROC curves (30 native/20 non-native compounds, at spike levels of 200/20 and100/10 ppm native/non-native, respectively). The “sweet spot” for F-ratio analysis was determined to be a S/N threshold of 10 coupled with a maximum of the 10 most chemically selective m/z (requiring a minimum of 3 m/z), corresponding to a ~ 21% improvement in the discovery rate of true positives relative to prior studies. Furthermore, it was observed that optimization of these software parameters did not depend upon a priori determination of the statistically correct number of positive instances in the sample classes. The AUC metric appears to be suitable for the evaluation of all data analysis methods that utilize the proper experimental design.

3D-GS/TOFMS, Data discovery, ROC curves, Fisher ra↗

Hydrogen Analysis by Gas Chromatography–Mass Spectrometry

The detection of hydrogen in complex gas mixtures is essential for many applications. Conventional approaches such as gas chromatography (GC) with thermal conductivity detection (TCD) and residual gas analyzers (RGAs) face significant limitations: TCD exhibits poor response when helium is used as a carrier gas, whereas RGAs lack chromatographic separation, preventing reliable quantification of hydrogen because of interference from other species. Traditional GC methods rely on dual-column configurations with packed or molecular-sieve porous layer open tubular (PLOT) columns to separate hydrogen from O2, N2, CO, CO2, CH4, and other hydrocarbons, increasing system complexity and limiting compatibility with mass spectrometry (MS) detection. In this work, we developed and validated a robust GC–MS method capable of directly detecting and quantifying hydrogen using electron ionization (EI) without dopants, reagent gases, or ion–molecule reaction schemes. By integrating a modified EI source and a cryogenically cooled single capillary column configuration, we achieved baseline separation of hydrogen from all major permanent gases and hydrocarbons in a refinery gas mixture using helium as the carrier gas. The method demonstrated excellent linearity, high sensitivity, and exceptional reproducibility. Adjustable sample-loop volumes and split ratios enabled optimization of peak shape and signal-to-noise performance for trace-level and percent-level hydrogen concentrations. Beyond hydrogen quantitation, the method provides simultaneous compositional profiling of other gases in a mixture in a single run, making it valuable for a wide range of tasks.

Lobodin, Vlad [ORNL]↗

Automated Nanoflow Two-Dimensional Reversed-Phase Liquid Chromatography System Enables In-Depth Proteome and Phosphoproteome Profiling of Nanoscale Samples

Two-dimensional reversed-phase liquid chromatography (2D RPLC) separations have enabled near-comprehensive proteome profiling of biological systems. However, large samples containing milligram amounts of protein are usually required due to the significant sample losses incurred during offline fractionation. The large sample requirements preclude the application of 2D RPLC to biological systems having sample availability in the nanogram to low-microgram range. To achieve in-depth proteomic studies of trace samples, we have developed an automated nanoflow 2D RPLC platform in which the first dimension high-pH fractionation was performed at 300 nL/min on a 75-µm i.d. capillary column.Each fraction was then fully transferred to a second-dimension nanoLC separation using an autosampler equipped with a custom-machined syringe. In addition to optimizing fractionation conditions, we found that the use of a plastic 96-well plate as collection device and the adding of n-Dodecyl ß-D-Maltoside (0.01%) in the collection buffer can significantly improve sample recovery. We have demonstrated the nanoflow 2D RPLC platform can achieve confident identifications of ~37,000–69,000 unique peptides, corresponding to ~5300–6900 protein groups using only 100 to 1000 ng of HeLa tryptic digest. Furthermore, by integrating phosphopeptide enrichment, the platform can identify as many as ~20,000 phosphopeptides from 100 µg of MCF7 protein digest. Because this platform is assembled from commercially available components, our approach can be readily adapted in other proteomics laboratories.

Mass spectrometry, multidimensional separations, n↗

Tandem Mass Tag Labeling Facilitates Reversed-Phase Liquid Chromatography-Mass Spectrometry Analysis of Hydrophilic Phosphopeptides

Protein phosphorylation is a critical post-translational modification (PTM). Despite recent technological advances in reversed-phase liquid chromatography (RPLC)-mass spectrometry (MS)-based proteomics, comprehensive phosphoproteomic coverage in complex biological systems remains challenging, especially for hydrophilic phosphopeptides with enriched regions of serines, threonines, and tyrosines that often orchestrate critical biological functions. It is known that G protein coupled receptors (GPCRs) are regulators of cellular signaling events and rely on phosphorylation of serines and threonines within the GPCR C-terminus for appropriate signaling. However, the low abundance of GPCRs, combined with the hydrophilicity of C-terminal phosphopeptides, has prevented robust RPLC-MS analysis of potentially crucial regions. To address this issue, we developed a simple, easily implemented method to introduce a commonly used tandem mass tag (TMT) to increase peptide hydrophobicity, effectively enhancing RPLC-MS analysis of hydrophilic peptides. This method was applied to study the peptide QPSSSR, a tryptic peptide located on the C-terminus of the GPCR CXCR3 not been reported, and validated by comparative RPLC-MS analyses of both a hydrophilic QPSSSR peptide library as well as common phosphopeptides before and after TMT labeling. We further confirmed the utility of this method by quantifying QPSSSR phosphorylation abundances in HEK 293 cells under different treatement conditions predicted to alter QPSSSR phosphorylation. We anticipate that this simple TMT-labeling method can be broadly used not only for decoding GPCR phosphoproteomes, but also for effective RPLC-MS analysis of other highly hydrophilic analytes.

Tsai, Chia-Feng↗

Uniformly 15N-Labeled Recombinant Ricin A-chain as an Internal Retention Time Standard for Increased Confidence in Forensic Identification of Ricin by Untargeted Nanoflow Liquid Chromatography-Tandem Mass Spectrometry

Ricin, a toxic protein from the castor plant, is of forensic and biosecurity interest because of its high toxicity and common occurrence in crimes and attempted crimes. Qualitative methods to detect ricin are therefore needed. Untargeted liquid chromatography-tandem mass spectrometry (LC-MS/MS) proteomics methods are well-suited because of their high speci-ficity. Specificity in LC-MS/MS comes from both the LC and MS components. However, modern untargeted proteomics methods often use nanoflow LC, which has less reproducible retention times than standard-flow LC, making it challenging to use retention time as a point of identification in a forensic assay. We address this challenge by using retention times rela-tive to a standard, namely uniformly 15N–labeled ricin A-chain produced recombinantly in a bacterial expression system. This material, added as an internal standard prior to trypsin digestion, produces a stable isotope labeled standard for every ricin tryptic peptide in the sample. We show that the MS signals for 15N and natural isotopic abundance ricin peptides are distinct, with mass shifts that correspond to the numbers of nitrogen atoms in each peptide or fragment. We also show that, as expected, labeled and unlabeled peptides coelute, with relative retention time differences of less than 0.2%.

ricin, mass spectrometry, isotope, nitrogen-15, re↗

Relating Molecular Properties to the Persistence of Marine Dissolved Organic Matter with Liquid Chromatography–Ultrahigh-Resolution Mass Spectrometry

Marine dissolved organic matter (DOM) contains a complex mixture of small molecules that eludes rapid biological degradation. Spatial and temporal variations in the abundance of DOM reflect the existence of fractions that are removed from the ocean over different time scales, ranging from seconds to millennia. However, it remains unknown whether the intrinsic chemical properties of these organic components relate to their persistence. Here, we elucidate and compare the molecular compositions of distinct DOM fractions with different lability along a water column in the North Atlantic Gyre. Our analysis utilized ultrahigh-resolution Fourier transform ion cyclotron resonance mass spectrometry at 21 T coupled to liquid chromatography and a novel data pipeline developed in CoreMS that generates molecular formula assignments and metrics of isomeric complexity. Clustering analysis binned 14 857 distinct molecular components into groups that correspond to the depth distribution of semilabile, semirefractory, and refractory fractions of DOM. The more labile fractions were concentrated near the ocean surface and contained more aliphatic, hydrophobic, and reduced molecules than the refractory fraction, which occurred uniformly throughout the water column. These findings suggest that processes that selectively remove hydrophobic compounds, such as aggregation and particle sorption, contribute to variable removal rates of marine DOM.

54 ENVIRONMENTAL SCIENCES↗

Comparability of Liquid Chromatography Tandem Mass Spectrometry Analysis of Dissolved Organic Matter across Laboratories

Non-targeted liquid chromatography tandem highresolution mass spectrometry (LC−MS/MS) is increasingly applied for the structure-resolved chemical analysis of dissolved organic matter (DOM). With new developments in MS instrumentation and analysis software, the approach has gained substantial momentum over the past decade. However, achieving high-quality analytical data that is reproducible and comparable across laboratories can be a bottleneck in non-targeted metabolomics and organic matter chemical analysis, especially for data reuse in repository-scale analyses. Understanding the capabilities as well as challenges of comparing LC−MS/MS data from different laboratories is necessary for inferring global trends from public data sets. To illuminate instrumentation factors that drive differences and variability, we used a standardized data analysis pipeline, including classical (CMN) and featurebased molecular networking (FBMN), to analyze data from a ring trial by 24 laboratories on identical sample sets of algal and DOM extracts that were mixed in predefined concentrations and spiked with standards. Our results showed that data sets from similar mass spectrometer types with unified instrument parameters were qualitatively comparable, resolving the same general trends and shared mass spectral features. Interlaboratory comparability was best for high-intensity features, while low-intensity features showed greater detection variability. Our analysis also highlights challenges when comparing data from instruments with different acquisition rates or operating with less standardized methods. Lastly, we provide recommendations for data integration, public data sharing, standardization, and best practices for standardized LC−MS/MS data acquisition, which will be critical for long-term time series and intercomparability of DOM chemical analyses.

DOM↗

Conformational Equilibria of Multimodal Chromatography Ligands in Water and Bound to Protein Surfaces

Multimodal chromatography uses small ligands with multiple modes of interaction, e.g., charged, hydrophobic or hydrogen bonding, to separate proteins from complex mixtures. The mechanism by which multimodal ligands interact with proteins is expected to be affected by ligand conformations, among other factors. In this report, we determine conformational equilibria of two commercially used multimodal cation exchange ligands, Capto MMC and Nuvia cPrime, in a range of solvents, a Lennard-Jones (LJ) liquid, ethanol, and water, using molecular dynamics (MD) simulations. By mapping ligand conformations onto two key torsion angles, ω and φ, in these solvents and in low and high dielectric media, we quantify the relative importance of intramolecular and solvent-mediated interactions. In a high dielectric medium, Capto MMC preferentially samples three conformations, which are stabilized by a combination of an intramolecular torsion potential (on ω) and LJ interactions. In an LJ liquid, solvent molecules compete with intramolecular interactions while simultaneously providing an osmotic force, stabilizing both closer and farther distances between ligand sites. This has the overall result of “flattening out” the conformational landscape. Interestingly, in ethanol and water, hydrogen bonding among the amide hydrogen and solvent molecules stabilizes two additional conformations of Capto MMC in which ω takes on less favorable cis-like configurations. MD simulations of ligands in free solution with three therapeutic antibody fragments show that ligand conformational equilibria remain effectively unchanged upon binding to proteins. Although, there is 20–30% dehydration of the overall ligand upon binding, the hydrogen-bonding sites are dehydrated to a much smaller extent, particularly in cis-like configurations. Conformational preferences of Nuvia cPrime are similar to that of Capto MMC, except for the effect of symmetry arising from the absence of an alkyl thiol tail. Characterizing the conformational equilibria of these two ligands in free solution and bound to a protein provides a foundation for developing a mechanistic understanding of protein–multimodal ligand interactions.

59 BASIC BIOLOGICAL SCIENCES↗

Characterizing Olefin Selectivity and Stability of Silver Salts in Ionic Liquids Using Inverse Gas Chromatography

Separation systems utilizing silver(I) ion-olefin complexation have limitations since silver(I) ions can be poisoned or reduced to metallic silver. Ionic liquids (ILs) are used as solvents for silver(I) ions to facilitate separations since their physico-chemical properties can be easily tuned. To develop separation systems with sustainable olefin selectivity, factors that affect silver(I) ion stability need to be understood. In this study, a total of 13 silver salt/IL mixtures were examined by inverse gas chromatography to identify the effects of silver salt anion and IL cation/anion combination on silver(I) ion stability. The effects of temperature and three different exposure gases on silver(I) ion stability were systematically studied. Exposing silver salt/IL mixtures to hydrogen at high temperatures had a greater effect on decreasing silver(I) ion-olefin complexation. Silver(I) ions from the silver bis[(trifluoromethyl)sulfonyl]imide ([NTf 2 – ]) salt were more stable in [NTf 2 – ]-containing ILs than in [BF 4 – ]-containing ILs. Optimum mixtures exhibited high olefin selectivity and were stable beyond 90 h when exposed to hydrogen gas.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Oxidative Catalytic Fractionation of Lignocellulosic Biomass Using a Co-N-P-C Catalyst and One-Step Isolation of Aromatic Monomers via Centrifugal Partition Chromatography

Methods for catalytic fractionation of biomass provide a means to convert lignin directly into monomers while generating a high-quality cellulosic stream, contrasting conventional biomass pretreatment strategies that prioritize the cellulosic fraction. Here, a nonprecious-metal Co-N-P-C catalyst is identified for aerobic oxidative catalytic fractionation (OCF) of poplar feedstock in dimethyl carbonate that achieves significantly higher yields of aromatic monomers (24 wt %) relative to those obtained with a recently reported Co-N-C catalyst in acetone solvent (15 wt %). Mechanistic studies indicate that the acidic properties of the catalyst contribute to its improved performance by promoting extraction of lignin from insoluble polysaccharides. This OCF process is complemented by the development of a new centrifugal partition chromatography (CPC) method that supports isolation of all five major aromatic monomers (syringic acid, syringaldehyde, vanillic acid, vanillin, and para-hydroxybenzoic acid) in a single liquid–liquid extraction purification step. Furthermore, this OCF/CPC sequence has important implications for future lignin valorization efforts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗