Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CARLO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

SU-E-T-35: An Investigation of the Accuracy of Cervical IMRT Dose Distribution Using 2D/3D Ionization Chamber Arrays System and Monte Carlo Simulation

Purpose: The purpose of this work is to compare the verification results of three solutions (2D/3D ionization chamber arrays measurement and Monte Carlo simulation), the results will help make a clinical decision as how to do our cervical IMRT verification. Methods: Seven cervical cases were planned with Pinnacle 8.0m to meet the clinical acceptance criteria. The plans were recalculated in the Matrixx and Delta4 phantom with the accurate plans parameters. The plans were also recalculated by Monte Carlo using leaf sequences and MUs for individual plans of every patient, Matrixx and Delta4 phantom. All plans of Matrixx and Delta4 phantom were delivered and measured. The dose distribution of iso slice, dose profiles, gamma maps of every beam were used to evaluate the agreement. Dose-volume histograms were also compared. Results: The dose distribution of iso slice and dose profiles from Pinnacle calculation were in agreement with the Monte Carlo simulation, Matrixx and Delta4 measurement. A 95.2%/91.3% gamma pass ratio was obtained between the Matrixx/Delta4 measurement and Pinnacle distributions within 3mm/3% gamma criteria. A 96.4%/95.6% gamma pass ratio was obtained between the Matrixx/Delta4 measurement and Monte Carlo simulation within 2mm/2% gamma criteria, almost 100% gamma pass ratio within 3mm/3% gamma criteria. The DVH plot have slightly differences between Pinnacle and Delta4 measurement as well as Pinnacle and Monte Carlo simulation, but have excellent agreement between Delta4 measurement and Monte Carlo simulation. Conclusion: It was shown that Matrixx/Delta4 and Monte Carlo simulation can be used very efficiently to verify cervical IMRT delivery. In terms of Gamma value the pass ratio of Matrixx was little higher, however, Delta4 showed more problem fields. The primary advantage of Delta4 is the fact it can measure true 3D dosimetry while Monte Carlo can simulate in patients CT images but not in phantom.

60 APPLIED LIFE SCIENCES↗

SU-E-T-546: Modeling and Validation of the a New Proton Therapy System Using a Monte-Carlo Environment Optimized for Protons

8 particle histories were run. Results: Range measurements of the Monte-Carlo simulations matched the measured data within 1mm. Distal fall-off of the simulated fields matched within <1mm. Lateral penumbra and field size measurements of the standard-sized square and half-beam blocked fields matched within 1mm at all three planes compared. A small difference was seen in the in-air profiles at doses <0%. The suspected cause of the difference was the aperture shape. The measured data utilized a divergent aperture. The Monte-Carlo calculation used a non-divergent aperture. Conclusion: The validation measurements indicate that we were able to accurately model the MEVION s250 Proton therapy system using Monte-Carlo Calculations. This may reduce the commissioning time for future users. Purpose: Monte-Carlo modeling is an important tool for understanding the behavior of therapeutic proton beams in a heterogeneous media such as the patient. To gain confidence that a Monte-Carlo model is accurate in complex geometries and media, it must first be compared with measurement in simple situations. This study documents the validation of our Monte-Carlo Model. Methods: A model of the MEVION s250 Proton therapy system was created in the TOPAS Monte-Carlo environment using machine geometry and field shaping system information provided by the vendor. For each of 24 options, validation of the TOPAS model was performed by comparing the dose scored by TOPAS to the dose measurements obtained during the commissioning of the treatment planning system. The measurements compared consisted of: pristine peak depth-dose profiles, in-air profiles for a standard-sized square field (20cm×20cm or 10cm×10cm depending on the maximum field size for each option) at isocenter and at 20cm upstream and downstream of isocenter, and in-air profiles with a half-beam blocked aperture at isocenter and at 20cm upstream and downstream of isocenter. For all Monte-Carlo simulations,.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monte Carlo Estimates of Eigenvalue Sensitivity to System Dimensions using Kernel Density Estimators

In the last decade there has been an increasing interest in calculating sensitivity coefficients in order to quantify the impact of uncertainty in material properties and system parameters on quantities of interest. Extensive work has been done developing Monte Carlo methods to estimate eigenvalue sensitivity to material properties. While deterministic methods exist for determining the eigenvalue sensitivity to system dimensions, the use of Monte Carlo methods to efficiently calculate eigenvalue sensitivity coefficients to system dimensions is still an open topic. Current Monte Carlo methods for calculating eigenvalue sensitivity coefficients to system dimensions are inefficient. Direct Monte Carlo perturbations require two additional simulations of high statistical precision in order to determine the eigenvalue sensitivity to the location of a single boundary. If the sensitivity to the location of multiple surfaces are desired, two additional simulations must be run for each surface. Kiedrowski and Favorite extended continuous energy Monte Carlo methods for sensitivities of nuclear cross sections to calculate sensitivities to interface boundaries or system dimensions to create the only current alternative to direct Monte Carlo calculations. However this method relies on the simulation of additional random walks launched at each surface crossing event. The present method extends upon Kiedrowski's work and eliminates the inefficient portions of the calculation through the use of Kernel Density Estimators (KDEs). The new method efficiently estimates eigenvalue sensitivities to the uniform expansion or contraction of material interface boundaries or system dimensions, negligibly impacting the runtime performance of the Monte Carlo code. The new estimator is tested on bare and reflected critical configurations in spherical geometry and is compared to estimates obtained from direct Monte Carlo perturbations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uncertainty Analyses for Localized Tallies in Monte Carlo Eigenvalue Calculations

It is well known that statistical estimates obtained from Monte Carlo criticality simulations can be adversely affected by cycle-to-cycle correlations in the fission source. In addition, there are several other more fundamental issues that may lead to errors in Monte Carlo results. These factors can have a significant impact on the calculated eigenvalue, localized tally means and their associated standard deviations. In fact, modern Monte Carlo computational tools may generate standard deviation estimates that are a factor of five or more lower than the true standard deviation for a particular tally due to the inter-cycle correlations in the fission source. The magnitude of this under-prediction can climb as high as one hundred when combined with an ill-converged fission source or poor sampling techniques. Since Monte Carlo methods are widely used in reactor analysis (as a benchmarking tool) and criticality safety applications, an in-depth understanding of the effects of these issues must be developed in order to support the practical use of Monte Carlo software packages. A rigorous statistical analysis of localized tally results in eigenvalue calculations is presented using the SCALE/KENO-VI and MCNP Monte Carlo codes. The purpose of this analysis is to investigate the under-prediction in the uncertainty and its sensitivity to problem characteristics and calculational parameters, and to provide a comparative study between the two codes with respect to this under-prediction. It is shown herein that adequate source convergence along with proper specification of Monte Carlo parameters can reduce the magnitude of under-prediction in the uncertainty to reasonable levels; below a factor of 2 when inter-cycle correlations in the fission source are not a significant factor. In addition, through the use of a modified sampling procedure, the effects of inter-cycle correlations on both the mean value and standard deviation estimates can be isolated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The X-43A Six Degree of Freedom Monte Carlo Analysis

This report provides an overview of the Hyper-X research vehicle Monte Carlo analysis conducted with the six-degree-of-freedom simulation. The methodology and model uncertainties used for the Monte Carlo analysis are presented as permitted. In addition, the process used to select hardware validation test cases from the Monte Carlo data is described. The preflight Monte Carlo analysis indicated that the X-43A control system was robust to the preflight uncertainties and provided the Hyper-X project an important indication that the vehicle would likely be successful in accomplishing the mission objectives. The X-43A in-flight performance is compared to the preflight Monte Carlo predictions and shown to exceed the Monte Carlo bounds in several instances. Possible modeling shortfalls are presented that may account for these discrepancies. The flight control laws and guidance algorithms were robust enough as a result of the preflight Monte Carlo analysis that the unexpected in-flight performance did not have undue consequences. Modeling and Monte Carlo analysis lessons learned are presented.

Baumann, Ethan↗

The X-43A Six Degree of Freedom Monte Carlo Analysis

This report provides an overview of the Hyper-X research vehicle Monte Carlo analysis conducted with the six-degree-of-freedom simulation. The methodology and model uncertainties used for the Monte Carlo analysis are presented as permitted. In addition, the process used to select hardware validation test cases from the Monte Carlo data is described. The preflight Monte Carlo analysis indicated that the X-43A control system was robust to the preflight uncertainties and provided the Hyper-X project an important indication that the vehicle would likely be successful in accomplishing the mission objectives. The X-43A inflight performance is compared to the preflight Monte Carlo predictions and shown to exceed the Monte Carlo bounds in several instances. Possible modeling shortfalls are presented that may account for these discrepancies. The flight control laws and guidance algorithms were robust enough as a result of the preflight Monte Carlo analysis that the unexpected in-flight performance did not have undue consequences. Modeling and Monte Carlo analysis lessons learned are presented.

Baumann, Ethan↗

Development of Monte Carlo Capability for Orion Parachute Simulations

Parachute test programs employ Monte Carlo simulation techniques to plan testing and make critical decisions related to parachute loads, rate-of-descent, or other parameters. This paper describes the development and use of a MATLAB-based Monte Carlo tool for three parachute drop test simulations currently used by NASA. The Decelerator System Simulation (DSS) is a legacy 6 Degree-of-Freedom (DOF) simulation used to predict parachute loads and descent trajectories. The Decelerator System Simulation Application (DSSA) is a 6-DOF simulation that is well suited for modeling aircraft extraction and descent of pallet-like test vehicles. The Drop Test Vehicle Simulation (DTVSim) is a 2-DOF trajectory simulation that is convenient for quick turn-around analysis tasks. These three tools have significantly different software architectures and do not share common input files or output data structures. Separate Monte Carlo tools were initially developed for each simulation. A recently-developed simulation output structure enables the use of the more sophisticated DSSA Monte Carlo tool with any of the core-simulations. The task of configuring the inputs for the nominal simulation is left to the existing tools. Once the nominal simulation is configured, the Monte Carlo tool perturbs the input set according to dispersion rules created by the analyst. These rules define the statistical distribution and parameters to be applied to each simulation input. Individual dispersed parameters are combined to create a dispersed set of simulation inputs. The Monte Carlo tool repeatedly executes the core-simulation with the dispersed inputs and stores the results for analysis. The analyst may define conditions on one or more output parameters at which to collect data slices. The tool provides a versatile interface for reviewing output of large Monte Carlo data sets while preserving the capability for detailed examination of individual dispersed trajectories. The Monte Carlo tool described in this paper has proven useful in planning several Crew Exploration Vehicle parachute tests.

Moore, James W.↗

Transport error estimation using residual Monte Carlo

The residual Monte Carlo (RMC) method is also known in the literature as sequential Monte Carlo and reduced-source Monte Carlo. Given a Monte Carlo method for solving a linear equation and an approximate solution to that system, the residual method enables use of essentially the same Monte Carlo algorithm to directly compute the additive error or “defect” associated with the approximate solution. As the size of the defect decreases relative to the size of the solution, the residual Monte Carlo method becomes increasingly efficient relative to the standard Monte Carlo (SMC) method. Here we present a new RMC algorithm for evaluating the space-angle error in S n radiation transport solutions, and provide computational examples demonstrating that it can be far more efficient than SMC for this purpose. Herein we also describe a particular pitfall that must be avoided if RMC is to be efficient, and explain why the performance of RMC can significantly differ between different transport problems and different quantities of interest for the same problem.

97 MATHEMATICS AND COMPUTING↗

Monte Carlo calculations of k{sub Q}, the beam quality conversion factor

Purpose: To use EGSnrc Monte Carlo simulations to directly calculate beam quality conversion factors, k{sub Q}, for 32 cylindrical ionization chambers over a range of beam qualities and to quantify the effect of systematic uncertainties on Monte Carlo calculations of k{sub Q}. These factors are required to use the TG-51 or TRS-398 clinical dosimetry protocols for calibrating external radiotherapy beams. Methods: Ionization chambers are modeled either from blueprints or manufacturers' user's manuals. The dose-to-air in the chamber is calculated using the EGSnrc user-code egs{sub c}hamber using 11 different tabulated clinical photon spectra for the incident beams. The dose to a small volume of water is also calculated in the absence of the chamber at the midpoint of the chamber on its central axis. Using a simple equation, k{sub Q} is calculated from these quantities under the assumption that W/e is constant with energy and compared to TG-51 protocol and measured values. Results: Polynomial fits to the Monte Carlo calculated k{sub Q} factors as a function of beam quality expressed as %dd(10){sub x} and TPR{sub 10}{sup 20} are given for each ionization chamber. Differences are explained between Monte Carlo calculated values and values from the TG-51 protocol or calculated using the computer program used for TG-51 calculations. Systematic uncertainties in calculated k{sub Q} values are analyzed and amount to a maximum of one standard deviation uncertainty of 0.99% if one assumes that photon cross-section uncertainties are uncorrelated and 0.63% if they are assumed correlated. The largest components of the uncertainty are the constancy of W/e and the uncertainty in the cross-section for photons in water. Conclusions: It is now possible to calculate k{sub Q} directly using Monte Carlo simulations. Monte Carlo calculations for most ionization chambers give results which are comparable to TG-51 values. Discrepancies can be explained using individual Monte Carlo calculations of various correction factors which are more accurate than previously used values. For small ionization chambers with central electrodes composed of high-Z materials, the effect of the central electrode is much larger than that for the aluminum electrodes in Farmer chambers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measured and Monte Carlo calculated k{sub Q} factors: Accuracy and comparison

Purpose: The journal Medical Physics recently published two papers that determine beam quality conversion factors, k{sub Q}, for large sets of ion chambers. In the first paper [McEwen Med. Phys. 37, 2179-2193 (2010)], k{sub Q} was determined experimentally, while the second paper [Muir and Rogers Med. Phys. 37, 5939-5950 (2010)] provides k{sub Q} factors calculated using Monte Carlo simulations. This work investigates a variety of additional consistency checks to verify the accuracy of the k{sub Q} factors determined in each publication and a comparison of the two data sets. Uncertainty introduced in calculated k{sub Q} factors by possible variation of W/e with beam energy is investigated further. Methods: The validity of the experimental set of k{sub Q} factors relies on the accuracy of the NE2571 reference chamber measurements to which k{sub Q} factors for all other ion chambers are correlated. The stability of NE2571 absorbed dose to water calibration coefficients is determined and comparison to other experimental k{sub Q} factors is analyzed. Reliability of Monte Carlo calculated k{sub Q} factors is assessed through comparison to other publications that provide Monte Carlo calculations of k{sub Q} as well as an analysis of the sleeve effect, the effect of cavity length and self-consistencies between graphite-walled Farmer-chambers. Comparison between the two data sets is given in terms of the percent difference between the k{sub Q} factors presented in both publications. Results: Monitoring of the absorbed dose calibration coefficients for the NE2571 chambers over a period of more than 15 yrs exhibit consistency at a level better than 0.1%. Agreement of the NE2571 k{sub Q} factors with a quadratic fit to all other experimental data from standards labs for the same chamber is observed within 0.3%. Monte Carlo calculated k{sub Q} factors are in good agreement with most other Monte Carlo calculated k{sub Q} factors. Expected results are observed for the sleeve effect and the effect of cavity length on k{sub Q}. The mean percent differences between experimental and Monte Carlo calculated k{sub Q} factors are -0.08, -0.07, and -0.23% for the Elekta 6, 10, and 25 MV nominal beam energies, respectively. An upper limit on the variation of W/e in photon beams from cobalt-60 to 25 MV is determined as 0.4% with 95% confidence. The combined uncertainty on Monte Carlo calculated k{sub Q} factors is reassessed and amounts to between 0.40 and 0.49% depending on the wall material of the chamber. Conclusions: Excellent agreement (mean percent difference of only 0.13% for the entire data set) between experimental and calculated k{sub Q} factors is observed. For some chambers, k{sub Q} is measured for only one chamber of each type--the level of agreement observed in this study would suggest that for those chambers the measured k{sub Q} values are generally representative of the chamber type.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation doses in volume-of-interest breast computed tomography—A Monte Carlo simulation study

Purpose: Cone beam breast computed tomography (breast CT) with true three-dimensional, nearly isotropic spatial resolution has been developed and investigated over the past decade to overcome the problem of lesions overlapping with breast anatomical structures on two-dimensional mammographic images. However, the ability of breast CT to detect small objects, such as tissue structure edges and small calcifications, is limited. To resolve this problem, the authors proposed and developed a volume-of-interest (VOI) breast CT technique to image a small VOI using a higher radiation dose to improve that region’s visibility. In this study, the authors performed Monte Carlo simulations to estimate average breast dose and average glandular dose (AGD) for the VOI breast CT technique. Methods: Electron–Gamma-Shower system code-based Monte Carlo codes were used to simulate breast CT. The Monte Carlo codes estimated were validated using physical measurements of air kerma ratios and point doses in phantoms with an ion chamber and optically stimulated luminescence dosimeters. The validated full cone x-ray source was then collimated to simulate half cone beam x-rays to image digital pendant-geometry, hemi-ellipsoidal, homogeneous breast phantoms and to estimate breast doses with full field scans. 13-cm in diameter, 10-cm long hemi-ellipsoidal homogeneous phantoms were used to simulate median breasts. Breast compositions of 25% and 50% volumetric glandular fractions (VGFs) were used to investigate the influence on breast dose. The simulated half cone beam x-rays were then collimated to a narrow x-ray beam with an area of 2.5 × 2.5 cm{sup 2} field of view at the isocenter plane and to perform VOI field scans. The Monte Carlo results for the full field scans and the VOI field scans were then used to estimate the AGD for the VOI breast CT technique. Results: The ratios of air kerma ratios and dose measurement results from the Monte Carlo simulation to those from the physical measurements were 0.97 ± 0.03 and 1.10 ± 0.13, respectively, indicating that the accuracy of the Monte Carlo simulation was adequate. The normalized AGD with VOI field scans was substantially reduced by a factor of about 2 over the VOI region and by a factor of 18 over the entire breast for both 25% and 50% VGF simulated breasts compared with the normalized AGD with full field scans. The normalized AGD for the VOI breast CT technique can be kept the same as or lower than that for a full field scan with the exposure level for the VOI field scan increased by a factor of as much as 12. Conclusions: The authors’ Monte Carlo estimates of normalized AGDs for the VOI breast CT technique show that this technique can be used to markedly increase the dose to the breast and thus the visibility of the VOI region without increasing the dose to the breast. The results of this investigation should be helpful for those interested in using VOI breast CT technique to image small calcifications with dose concern.

60 APPLIED LIFE SCIENCES↗

SU-E-T-761: TOMOMC, A Monte Carlo-Based Planning VerificationTool for Helical Tomotherapy

Purpose: Present a new Monte Carlo code (TOMOMC) to calculate 3D dose distributions for patients undergoing helical tomotherapy treatments. TOMOMC performs CT-based dose calculations using the actual dynamic variables of the machine (couch motion, gantry rotation, and MLC sequences). Methods: TOMOMC is based on the GEPTS (Gama Electron and Positron Transport System) general-purpose Monte Carlo system (Chibani and Li, Med. Phys. 29, 2002, 835). First, beam models for the Hi-Art Tomotherpy machine were developed for the different beam widths (1, 2.5 and 5 cm). The beam model accounts for the exact geometry and composition of the different components of the linac head (target, primary collimator, jaws and MLCs). The beams models were benchmarked by comparing calculated Pdds and lateral/transversal dose profiles with ionization chamber measurements in water. See figures 1–3. The MLC model was tuned in such a way that tongue and groove effect, inter-leaf and intra-leaf transmission are modeled correctly. See figure 4. Results: By simulating the exact patient anatomy and the actual treatment delivery conditions (couch motion, gantry rotation and MLC sinogram), TOMOMC is able to calculate the 3D patient dose distribution which is in principal more accurate than the one from the treatment planning system (TPS) since it relies on the Monte Carlo method (gold standard). Dose volume parameters based on the Monte Carlo dose distribution can also be compared to those produced by the TPS. Attached figures show isodose lines for a H&N patient calculated by TOMOMC (transverse and sagittal views). Analysis of differences between TOMOMC and TPS is an ongoing work for different anatomic sites. Conclusion: A new Monte Carlo code (TOMOMC) was developed for Tomotherapy patient-specific QA. The next step in this project is implementing GPU computing to speed up Monte Carlo simulation and make Monte Carlo-based treatment verification a practical solution.

60 APPLIED LIFE SCIENCES↗

Recent advances and future prospects for Monte Carlo

The history of Monte Carlo methods is closely linked to that of computers: The first known Monte Carlo program was written in 1947 for the ENIAC; a pre-release of the first Fortran compiler was used for Monte Carlo In 1957; Monte Carlo codes were adapted to vector computers in the 1980s, clusters and parallel computers in the 1990s, and teraflop systems in the 2000s. Recent advances include hierarchical parallelism, combining threaded calculations on multicore processors with message-passing among different nodes. With the advances In computmg, Monte Carlo codes have evolved with new capabilities and new ways of use. Production codes such as MCNP, MVP, MONK, TRIPOLI and SCALE are now 20-30 years old (or more) and are very rich in advanced featUres. The former 'method of last resort' has now become the first choice for many applications. Calculations are now routinely performed on office computers, not just on supercomputers. Current research and development efforts are investigating the use of Monte Carlo methods on FPGAs. GPUs, and many-core processors. Other far-reaching research is exploring ways to adapt Monte Carlo methods to future exaflop systems that may have 1M or more concurrent computational processes.

99 GENERAL AND MISCELLANEOUS↗

Final Report: 06-LW-013, Nuclear Physics the Monte Carlo Way

This is document reports the progress and accomplishments achieved in 2006-2007 with LDRD funding under the proposal 06-LW-013, 'Nuclear Physics the Monte Carlo Way'. The project was a theoretical study to explore a novel approach to dealing with a persistent problem in Monte Carlo approaches to quantum many-body systems. The goal was to implement a solution to the notorious 'sign-problem', which if successful, would permit, for the first time, exact solutions to quantum many-body systems that cannot be addressed with other methods. In this document, we outline the progress and accomplishments achieved during FY2006-2007 with LDRD funding in the proposal 06-LW-013, 'Nuclear Physics the Monte Carlo Way'. This project was funded under the Lab Wide LDRD competition at Lawrence Livermore National Laboratory. The primary objective of this project was to test the feasibility of implementing a novel approach to solving the generic quantum many-body problem, which is one of the most important problems being addressed in theoretical physics today. Instead of traditional methods based matrix diagonalization, this proposal focused a Monte Carlo method. The principal difficulty with Monte Carlo methods, is the so-called 'sign problem'. The sign problem, which will discussed in some detail later, is endemic to Monte Carlo approaches to the quantum many-body problem, and is the principal reason that they have not been completely successful in the past. Here, we outline our research in the 'shifted-contour method' applied the Auxiliary Field Monte Carlo (AFMC) method.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modified Closures in Monte Carlo Algorithms for Diffusive Binary Stochastic Media Transport Problems

In a stochastic medium, the material properties at a given spatial location are known only statistically. The most common approach to solving particle transport problems involving binary stochastic media (BSM) is to use the atomic mix approximation in which the transport problem is solved using homogenized (volume-averaged) material properties. A common deterministic model developed for solving BSM particle transport problems is the Levermore-Pomraning (LP) model. Zimmerman and Adams proposed a Monte Carlo algorithm (Algorithm A) that solves the LP equations and another Monte Carlo algorithm (Algorithm B) that locally preserves the sampled material realization; we refer to these Monte Carlo algorithms as the LP and LPLRP (LP local realization preserving) algorithms, respectively. One-dimensional (1D) planar geometry benchmark studies have shown that the LPLRP algorithm is often significantly more accurate than the LP algorithm for problems with an incident angular flux as well as for problems with an interior source. The LPLRP algorithm implementation in these benchmark comparisons made explicit use of the one-dimensional nature of the problem. The LP model is derived by assuming an 'upwind' closure in the coupling term relating the two materials in a binary stochastic medium. Su and Pomraning developed a modified form of this closure by considering the small correlation length limit and requiring the modified closure to produce the correct exponential decay for a source-free half-line albedo problem in rod geometry. They concluded that the modified closure is generally not inferior to the LP closure and in some cases is significantly better. Brantley investigated the use of the Su-Pomraning (SP) closure in the Monte Carlo LP algorithm (LP-SP) for the suite of benchmark problems and concluded that 1) the LP-SP algorithm was somewhat more accurate overall than the LP algorithm and somewhat less accurate overall than the LPLRP algorithm for an incident angular flux benchmark suite, and 2) the LP-SP algorithm was generally the least accurate of the algorithms for an interior source benchmark suite. Larsen et al. performed an asymptotic analysis of the transport equation in 1D planar geometry for the situation in which the physical system is 1) a random binary stochastic medium with material macroscopic total cross sections and mean slab width values of O(1) or smaller and 2) optically thick with weak absorption and sources at each spatial point and therefore globally diffusive. The asymptotic analysis demonstrates that, under these assumptions, the transport equation limits to the conventional diffusion equation with atomically-mixed (volume-averaged) material properties. Larsen et al. also demonstrate that, under these same assumptions, the LP equations asymptotically limit to an atomically-mixed diffusion equation with a diffusion coefficient that is too large, leading to an unphysical flattening of the ensemble-averaged scalar flux distribution. Vasques and Yadav recently performed an asymptotic analysis of an adjusted Levermore-Pomraning closure in which the Markovian transition functions are rescaled such that the equations asymptotically limit to the correct atomically-mixed diffusion equation; we refer to this model as LP-VY. In this paper, we demonstrate that the adjusted LP closure proposed by Vasques and Yadav is a special case of the SP closure obtained by assuming that the absorption cross sections in the two materials are equal. We further demonstrate that the Su-Pomraning closure has the correct asymptotic limit for the diffusive physical system and is therefore an appropriate closure for these problems. We also describe how to incorporate these various closures into the Monte Carlo LP and LPLRP particle transport algorithms, and we present numerical results comparing the accuracy of the Monte Carlo LP, LP-VY, LP-SP, LPLRP, and LPLRP-SP algorithms for the set of diffusive benchmark problems. We demonstrated that the SP closure has the correct asymptotic limit for the diffusive physical system under investigation in this paper and that the VY closure is a special case of the SP closure obtained by assuming equal absorption in the two materials. Both of these closures are readily implemented in the Monte Carlo LP and LPLRP algorithms for particle transport in BSM. Through numerical comparisons to a diffusive benchmark suite, we confirmed that 1) the LP and LPLRP algorithms do not limit to the appropriate diffusion solution and 2) the LP-VY, LP-SP, and LPLRP-SP algorithms limit to the appropriate diffusion solution and are of comparable accuracy. The LPLRP algorithm has been shown to be generally more accurate than the LP algorithm for non-diffusive problems. However, the numerical results in this paper indicate that the LPLRP algorithm does not limit to the correct diffusion equation for the asymptotic limit under consideration. The work in this paper demonstrates that the SP algorithm does limit to the correct diffusion equation for the asymptotic limit considered. Future work will investigate the possibility of whether the LPLRP-SP algorithm is accurate for both diffusive and non-diffusive problems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multilevel Monte Carlo Estimation of Unbiased Expectation via Sample Reuse and the Low Variance Estimation of Asymptotic Rates

A new variant of the multilevel Monte Carlo estimator [5, 3, 9, 12] is presented for the estimation of expectation statistics that utilizes sample reuse in specified levels, explicitly removes approximation error bias associated with numerically computed output quantities of interest that have an asymptotic limit behavior, and permits a low variance estimate of the asymptotic rate of convergence to that limit. In addition, it is shown that this new multilevel Monte Carlo variant can yield a computational cost savings. A review of Monte Carlo and multilevel Monte Carlo estimators is presented that includes analysis of expected value, expected mean squared error, and the calculation of optimized multilevel sample size parameters. The multilevel Monte Carlo estimator produces estimates of expectation for numerically approximated output quantities of interest that are biased by approximation error. When the quantity of interest can be modeled as the asymptotic limit of numerically approximated output quantities of interest, it is theoretically possible to remove this approximation error bias in the multilevel Monte Carlo estimator. In actual implementations, however, this procedure is unreliable due to statistical variability and inaccuracy in estimating the needed asymptotic limit. Analysis and numerical experiment show that the proposed variant of the multilevel Monte Carlo method greatly reduces (in some cases eliminates) the statistical variability in this limit estimation.

Barth, Timothy↗

The Transient Multi-Level method for Monte Carlo reactor statics calculations

The Transient Multi-Level (TML) method is applied to a time-dependent Monte Carlo transport solver to offload some of the computational burden of the expensive Monte Carlo solve to lower-order Coarse Mesh Finite Difference (CMFD) and Exact Point Kinetics Equations (EPKE) solvers via factorization of the neutron flux at the transport and CMFD levels using the Predictor Corrector Quasi-Static Method (PCQM). The Monte Carlo transient is solved by a modified fission source iteration scheme that introduces a single transient source bank. The method is implemented in the production-level Monte Carlo code, Shift, and verified with prescribed reactivity ramps from the two-dimensional version of the C5G7-TD reactor benchmark. The results show that, as compared to other quasi-static methods, the TML reduces the stochastic noise inherent to the transient Monte Carlo solver by factors of ~2 to 6 for various norm comparisons of the reactor power amplitude. Finally, the TML additionally reduces the number of Monte Carlo evaluations needed to simulate the transient, leading to roughly an order of magnitude improvement in CPU time relative to the standard PCQM for the problems tested.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Discrete ordinates analysis of the forced-flight variance reduction technique in Monte Carlo neutral particle transport simulations

This paper presents mathematical formulations and methods to predict the effect of forced-flight variance reduction on Monte Carlo tally variance and calculation time. This includes deducing biasing operators that are then used to construct a history-score probability density function (HSPDF), which represents all possible Monte Carlo random walks and gives the probability of a Monte Carlo history scoring in a tally from a particular phase-space position. The history-score moment equations (HSMEs), the statistical moments of the HSPDF, are then derived to calculate the statistical behavior of the Monte Carlo tally when forced-flight variance reduction is applied. In addition, the future-time equation (FTE) is derived to predict the Monte Carlo computational time as a result of applying forced-flight variance reduction. The solutions of the HSMEs and FTE can be used to predict Monte Carlo computational cost. Furthermore, this work also describes a discrete ordinates method to solve the forced-flight HSMEs and FTE. Several 1-D and 2-D test problems verify that the derivations are performed and implemented correctly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗