Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAMERA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

New Design Yields Robust Large-Area Framing Camera

Framing cameras provide a discrete series of images over a short period of time in a manner that mimics a high-speed movie camera, but with individual shutter times that must be extremely short in order to capture freeze-frame images of rapidly evolving phenomena such as high-explosive shock-driven ejecta, dynamic compression of metals, and high-velocity fluid flow. The NNSS has designed and fielded a new, large-area, gated framing camera called Kraken. The camera design emphasized manufacturability and flexibility by improving imager yield and creating a camera architecture to shorten design cycles. Design strategies and field data are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron counting with cameras

A research project is presented in which we aim at counting individual neutrons with CCD-like cameras. We explore theoretically a technique that allows us to use imaging detectors as counting detectors at lower counting rates, and transits smoothly to continuous imaging at higher counting rates. As such, the hope is to combine the good background rejection properties of standard neutron counting detectors with the absence of dead time of integrating neutron imaging cameras as well as their very good spatial resolution. Compared to Xray detection, the essence of thermal neutron detection is the nuclear conversion reaction. The released energies involved are of the order of a few MeV, while X-ray detection releases energies of the order of the photon energy, which is in the 10 KeV range. Thanks to advances in camera technology which have resulted in increased quantum efficiency, lower noise, as well as increased frame rate up to 100 fps for CMOS-type cameras, this more than 100-fold higher available detection energy implies that the individual neutron detection light signal can be significantly above the noise level, as such allowing for discrimination and individual counting, which is hard to achieve with X-rays. The time scale of CMOS-type cameras doesn't allow one to consider time-of-flight measurements, but kinetic experiments in the 10 ms range are possible. The theory is next confronted to the first experimental results. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

COMPACT CdZnTe-BASED GAMMA CAMERA FOR PROSTATE CANCER IMAGING

In this paper, we discuss the design of a compact gamma camera for high-resolution prostate cancer imaging using Cadmium Zinc Telluride (CdZnTe or CZT) radiation detectors. Prostate cancer is a common disease in men. Nowadays, a blood test measuring the level of prostate specific antigen (PSA) is widely used for screening for the disease in males over 50, followed by (ultrasound) imaging-guided biopsy. However, PSA tests have a high false-positive rate and ultrasound-guided biopsy has a high likelihood of missing small cancerous tissues. Commercial methods of nuclear medical imaging, e.g. PET and SPECT, can functionally image the organs, and potentially find cancer tissues at early stages, but their applications in diagnosing prostate cancer has been limited by the smallness of the prostate gland and the long working distance between the organ and the detectors comprising these imaging systems. CZT is a semiconductor material with wide band-gap and relatively high electron mobility, and thus can operate at room temperature without additional cooling. CZT detectors are photon-electron direct-conversion devices, thus offering high energy-resolution in detecting gamma rays, enabling energy-resolved imaging, and reducing the background of Compton-scattering events. In addition, CZT material has high stopping power for gamma rays; for medical imaging, a few-mm-thick CZT material provides adequate detection efficiency for many SPECT radiotracers. Because of these advantages, CZT detectors are becoming popular for several SPECT medical-imaging applications. Most recently, we designed a compact gamma camera using CZT detectors coupled to an application-specific-integrated-circuit (ASIC). This camera functions as a trans-rectal probe to image the prostate gland from a distance of only 1-5 cm, thus offering higher detection efficiency and higher spatial resolution. Hence, it potentially can detect prostate cancers at their early stages. The performance tests of this camera have been completed. The results show better than 6-mm resolution at a distance of 1 cm. Details of the test results are discussed in this paper.

36 MATERIALS SCIENCE↗

Predicting 3D Motions from Single-Camera Optical Test Data

In a typical optical test, a stereo camera pair is required to measure the three-dimensional motion of a test article; one camera typically only measures motions in the image plane of the camera, and measurements in the out-of-plane direction are missing. Finite element expansion techniques provide a path to estimate responses from a test at unmeasured degrees of freedom. Treating the case of a single camera as a measurement with unmeasured degrees of freedom, a finite element model is used to expand to the missing third dimension of the image data, allowing a full-field, three-dimensional measurement to be obtained from a set of images from a single camera. The key to this technique relies on the mapping of finite element deformations to image deformations, creating a set of mode shape images that are used to filter the response in the image into modal responses. These modal responses are then applied to the finite element model to estimate physical responses at all finite element model degrees of freedom. The mapping from finite element model to image is achieved using synthetic images produced by a rendering software. Finally, the technique is applied first to a synthetic deformation image, and then is validated using an experimental set of images.

47 OTHER INSTRUMENTATION↗

Scintillation event imaging with a single photon avalanche diode camera

Position and time measurements of scintillation events encode information about the radiation source. Single photon avalanche diode (SPAD) arrays offer multiple-megapixel spatial resolution and tens of picoseconds temporal resolution for detecting single photons. Current lensless designs for measuring scintillation events use sensors that are lower in spatial resolution. Camera-based designs use sensors that are lower in temporal resolution or readout rate and cannot image individual interactions. Here we propose to image scintillation events in a thick, monolithic scintillator using a high-resolution SPAD camera. We demonstrate that a commercial SPAD camera is able to gather sufficient signal to image individual scintillation events and observe 3D shifts in their spatial distribution. Simulations show that a SPAD camera can localize individual scintillation events in 3D. We report direct imaging of gamma-ray interactions in a scintillator with a SPAD camera. The proposed design may allow to measure complex signatures of individual particles interacting in the scintillator.

47 OTHER INSTRUMENTATION↗

Tomographic analysis of tangential viewing cameras (invited)

Many tokamaks now use visible light cameras to observe plasma-wall interactions and integrated line emission. The DIII-D coherence imaging spectroscopy diagnostic cameras image interferograms that encode line integrated velocity. By modeling the 2D camera image pixels as line of sight integrals through an axisymmetric discrete grid, it is possible to do tomographic analysis to determine the local plasma line emissivity and parallel velocity. Approaches to solve the inverse problem posed by these tangential viewing cameras are presented. The inversion begins with calculation of the sparse response matrix that encompasses all the geometry and diagnostic information and reduces the process of image formation to a sparse matrix-vector multiply. Our report includes techniques for determining the detailed geometry of the camera views and methods for handling physical quantities that vary spatially. Additionally, the size of the response matrix has driven the development of capability to distribute the coarse parallel calculation across a heterogeneous cluster of computers on the Energy Sciences Network. Iterative techniques are then used to solve the sparse matrix-vector linear system

47 OTHER INSTRUMENTATION↗

A 1D Lyman-alpha profile camera for plasma edge neutral studies on the DIII-D tokamak

A one dimensional, absolutely calibrated pinhole camera system was installed on the DIII-D tokamak to measure edge Lyman-alpha (Ly-α) emission from hydrogen isotopes, which can be used to infer neutral density and ionization rate profiles. The system is composed of two cameras, each providing a toroidal fan of 20 lines of sight, viewing the plasma edge on the inboard and outboard side of DIII-D. The cameras’ views lie in a horizontal plane 77 cm below the midplane. At its tangency radius, each channel provides a radial resolution of ~2 cm full width at half maximum (FWHM) with a total coverage of 22 cm. Each camera consists of a rectangular pinhole, Ly-α reflective mirror, narrow-band Ly-α transmission filter, and a 20 channel AXUV photodetector. The combined mirror and transmission filter have a FWHM of 5 nm, centered near the Ly-α wavelength of 121.6nm and is capable of rejecting significant, parasitic carbon-III (C-III) emission from intrinsic plasma impurities. To provide a high spatial resolution measurement in a compact footprint, the camera utilizes advanced engineering and manufacturing techniques including 3D printing, high stability mirror mounts, and a novel alignment procedure. Absolutely calibrated, spatially resolved Ly-α brightness measurements utilize a bright, isolated line with low parasitic surface reflections and enable quantitative comparison to modeling to study divertor neutral leakage, main chamber fueling, and radial particle transport.

Ionization Rate↗

A multi-mass and multi-hit two-camera 3D ion momentum imaging system

We demonstrate an improved two-camera system for multi-mass and multi-hit three-dimensional (3D) momentum imaging of ions. The imaging system employs two conventional complementary metal–oxide–semiconductor cameras. We have shown previously that the system can time slice ion Newton spheres with a time resolution of 8.8 ns, limited by camera timing jitter [J. Chem. Phys., 158, 191104 (2023)]. In this work, a jitter correction method was developed to suppress the camera jitter and improve the time resolution to better than 2 ns. With this resolution, full 3D momentum distributions of ions can be obtained. We further show that this method can detect two ions with different masses when utilizing both the rising and falling edges of the cameras.

Instruments & Instrumentation↗

A Multi-Criteria Approach to Camera Motion Design for Volume Data Animation

We present an integrated camera motion design and path generation system for building volume data animations. Creating animations is an essential task in presenting complex scientific visualizations. Existing visualization systems use an established animation function based on keyframes selected by the user. This approach is limited in providing the optimal in-between views of the data. Alternatively, computer graphics and virtual reality camera motion planning is frequently focused on collision free movement in a virtual walkthrough. For semi-transparent, fuzzy, or blobby volume data the collision free objective becomes insufficient. Here, we provide a set of essential criteria focused on computing camera paths to establish effective animations of volume data. Our dynamic multi-criteria solver coupled with a force-directed routing algorithm enables rapid generation of camera paths. Once users review the resulting animation and evaluate the camera motion, they are able to determine how each criterion impacts path generation. In this paper, we demonstrate how incorporating this animation approach with an interactive volume visualization system reduces the effort in creating context-aware and coherent animations. This frees the user to focus on visualization tasks with the objective of gaining additional insight from the volume data.

42 ENGINEERING↗

A Nonintrusive Optical Approach to Characterize Heliostats in Utility-Scale Power Tower Plants: Camera Position Sensitivity Analysis

Optics plays a major role in the effectiveness of concentrating solar power (CSP) technologies. The nonintrusive optical (NIO) approach developed by the National Renewable Energy Laboratory uses uncrewed aircraft system (UAS)-based imaging to survey heliostats in a commercial-scale power tower CSP plant and characterize their optical errors. The image processing algorithm uses photogrammetry to calculate the camera position for each image frame, and the accuracy of the estimated optical errors is highly sensitive to the calculated camera position accuracy. In this study, we simulate a series of case studies in python to examine the impact of different parameters of the sensitivity of the camera calculation, including the number of facet corners used as control points for the photogrammetric calculation, precision error in the detected pixel locations of the facet corners in the image, and precision error of the canting and mounting positions of the facets of the heliostat. The case studies consider heliostat geometry based on three commercial designs to serve as representative examples of different possible sizes of heliostats that the NIO method could be applied to. The results show that increasing the number of control points can improve accuracy for heliostats with many facets, pixel precision has a significantly larger impact on camera calculation accuracy than facet canting and mounting errors, and the camera distance and focal length must be chosen to ensure adequate pixel accuracy on the heliostat surface depending on the size of heliostat. In conclusion, based on the results, recommendations for the allowable values of each parameter are provided to achieve the required NIO optical error estimation accuracy depending on the size of heliostat.

14 SOLAR ENERGY↗

SU-E-J-46: Development of a Compton Camera Prototype for Online Range Verification of Laser-Accelerated Proton Beams

Purpose: Development of a photon detection system designed for online range verification of laser-accelerated proton beams via prompt-gamma imaging of nuclear reactions. Methods: We develop a Compton camera for the position-sensitive detection of prompt photons emitted from nuclear reactions between the proton beam and biological samples. The detector is designed to be capable to reconstruct the photon source origin not only from the Compton scattering kinematics of the primary photon, but also to allow for tracking of the Compton-scattered electrons. Results: Simulation studies resulted in the design of the Compton camera based on a LaBr{sub 3}(Ce) scintillation crystal acting as absorber, preceded by a stacked array of 6 double-sided silicon strip detectors as scatterers. From the design simulations, an angular resolution of ≤ 2° and an image reconstruction efficiency of 10{sup −3} −10{sup −5} (at 2–6 MeV) can be expected. The LaBr{sub 3} crystal has been characterized with calibration sources, resulting in a time resolution of 273 ps (FWHM) and an energy resolution of about 3.8% (FWHM). Using a collimated (1 mm diameter) {sup 137}Cs calibration source, the light distribution was measured for each of 64 pixels (6×6 mm{sup 2}). Data were also taken with 0.5 mm collimation and 0.5 mm step size to generate a reference library of light distributions that allows for reconstructing the interaction position of the initial photon using a k-nearest neighbor (k-NN) algorithm developed by the Delft group. Conclusion: The Compton-camera approach for prompt-gamma detection offers promising perspectives for ion beam range verification. A Compton camera prototype is presently being developed and characterized in Garching. Furthermore, an arrangement of, e.g., 4 camera modules could even be used in a ‘gamma-PET’ mode to detect delayed annihilation radiation from positron emitters in the irradiation interrupts (with improved performance in the presence of an additional third (prompt) photon (as in 10C and 14O). This work was supported by the DFG Cluster of Excellence MAP (Munich-Centre for Advanced Photonics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Applying compressive sensing to TEM video: A substantial frame rate increase on any camera

One of the main limitations of imaging at high spatial and temporal resolution during in-situ transmission electron microscopy (TEM) experiments is the frame rate of the camera being used to image the dynamic process. While the recent development of direct detectors has provided the hardware to achieve frame rates approaching 0.1 ms, the cameras are expensive and must replace existing detectors. In this paper, we examine the use of coded aperture compressive sensing (CS) methods to increase the frame rate of any camera with simple, low-cost hardware modifications. The coded aperture approach allows multiple sub-frames to be coded and integrated into a single camera frame during the acquisition process, and then extracted upon readout using statistical CS inversion. Here we describe the background of CS and statistical methods in depth and simulate the frame rates and efficiencies for in-situ TEM experiments. Depending on the resolution and signal/noise of the image, it should be possible to increase the speed of any camera by more than an order of magnitude using this approach.

36 MATERIALS SCIENCE↗

Aircraft Video Camera (CAM-AIR) Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) Aerial Facility (AAF) video cameras are installed in the cockpit of ARM’s research aircraft looking forward and in the belly of the plane looking down at the ground. Prior to the Aerosol and Cloud Experiments in the Eastern North Atlantic (ACE-ENA) field campaign in the Azores during 2017, the P1344 camera was flown in the forward (cockpit) position and the P1347 camera was flown in the nadir (belly) position. Since only the forward camera was flown for ACE-ENA and the Cloud, Aerosol, and Complex Terrain Interactions (CACTI) field campaign in Argentina during 2018–2019, the camera with the higher resolution (P1347) was moved to the cockpit.

47 OTHER INSTRUMENTATION↗

Large Game Distribution Camera Study at Los Alamos National Laboratory [Poster]

The unique habitats at the Laboratory support a diverse community of wildlife. The habitat types that include Pinon Juniper, Ponderosa Pine, and Mixed-conifer forests each provide different resources important for a variety of species. Wildlife monitoring for large game animals can be challenging because they avoid interactions with humans, and prefer undeveloped areas. This study was conducted to analyze the distribution of predators and other game animals seasonally across the Laboratory. The data gathered will be used to make recommendations regarding wildlife management for conservation and protection. Utilizing game cameras to remotely monitor wildlife was determined to be the most effective, noninvasive method to gather the necessary data. As camera technology has advanced, game cameras have become adequate for documenting individuals, and are commonly used in wildlife studies on predation, abundance, occupancy, diversity, and endangered species detection. Twenty cameras were placed across the LANL landscape using a modified systematic sampling design. They were deployed in February 2018 and retrieved in January 2019, thus each camera sampled for one full year. All images were reviewed and the species, number, age, and sex of all animals in the photo were recorded. Here we present data for the most abundant species encountered: deer, elk, coyote, bear, bobcat, mountain lion, and fox respectively. The data were summarized by species and season. Future work will include occupancy modelling for each species. This will allow the development of heat maps showing species distributions across the Laboratory.

54 ENVIRONMENTAL SCIENCES↗

Large Game Distribution Camera Study at Los Alamos National Laboratory

The unique habitats at the Laboratory support a diverse community of wildlife. The habitat types that include Pinon Juniper, Ponderosa Pine, and Mixed-conifer forests each provide different resources important for a variety of species. Wildlife monitoring for large game animals can be challenging because they avoid interactions with humans, and prefer undeveloped areas. This study was conducted to analyze the distribution of predators and other game animals seasonally across the Laboratory. This research informs decisions regarding wildlife management recommendations for conservation and protection. This study utilized game cameras to remotely monitor wildlife. As camera technology has advanced, game cameras have become adequate for documenting individuals, and are commonly used in wildlife studies on predation, abundance, occupancy, diversity, and endangered species detection. Twenty cameras were placed across the LANL landscape using a modified systematic sampling design. They were deployed in February 2018 and retrieved in January 2019, thus each camera sampled for one full year. All images were reviewed and the species, number, age, and sex of all animals in the photo were recorded. Here we present data for the most abundant species encountered: deer, elk, coyote, bear, bobcat, mountain lion, and fox respectively. The data were summarized by species and season. Future work will include occupancy modelling for each species. This will allow the development of heat maps showing species distributions across the Laboratory.

59 BASIC BIOLOGICAL SCIENCES↗

Neutron Positioning and Geometric Distortion Correction on the SNS SiPM Anger Camera

Neutron Anger cameras are scintillator-based thermal neutron detectors that utilize pixelated photosensors to read out visible light signals and position neutrons accurately They are versatile detectors that can cover large areas for diffraction instruments and offer high efficiency and sub-millimeter spatial resolution. Photomultiplier Tube (PMT) based cameras are installed on three instruments at Spallation Neutron Source (SNS). The next generation camera uses Silicon Photomultipliers (SiPMs) instead of PMTs, which allows for a more compact design and higher spatial resolution. In this report, the Gaussian least-squares position fitting method is described in detail, as well as the method used to correct for geometric distortions across the face of the camera. Results from neutron camera tests before and after the distortion correction are shown and the spatial resolution is quantified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigating Camera Calibration Methods for Naturalistic Driving Studies

Naturalistic driving studies typically utilize a variety of sensors, including radar, kinematic sensors, and video cameras. While the main objective of such sensors is typically safety focused, with a goal of recording accidents and near accidents for later review, the instrumentation provides a valuable resource for a variety of transportation research. Some applications, however, require additional processing to improve the utility of the data. In this work, we describe a computer vision procedure for calibrating front view cameras for the Second Strategic Highway Research Project. A longitudinal stability study of the estimated parameters across a small sample set of cameras is presented along with a proposed procedure for calibrating a larger number of cameras from the study. A simple use case is presented as one example of the utility of this work. Finally, we discuss plans for calibrating the complete set of approximately 3000 cameras from this study.

Paone, Jeffrey R.↗

A 1D Lyman-alpha Profile Camera for Plasma Edge Neutral Studies on the DIII-D Tokamak

A one dimensional, absolutely calibrated pinhole camera system was installed on the DIII-D tokamak to measure edge Lyman-alpha (Ly-a) emission from hydrogenic isotopes which can be used to infer neutral density and ionization rate proles. The system is composed of two cameras, each providing a toroidal fan of twenty lines of sight, viewing the plasma edge on the inboard and outboard side of DIII-D. The cameras' views lie in a horizontal plane 77 cm below the midplane. At its tangency radius, each channel provides a radial resolution of approximately 2 cm full width at half maximum (FWHM) with a total coverage of 22 cm. Each camera consists of a rectangular pinhole, Ly-a reflective mirror, narrow-band Ly-a transmission fiter, and a 20 channel AXUV photodetector. The combined mirror and transmission fiter have a FWHM of 5 nm, centered near the Ly-a wavelength of 121.6 nm and is capable of rejecting significant, parasitic carbon-III (C-III) emission from intrinsic plasma impurities. To provide a high spatial resolution measurement in a compact footprint, the camera utilizes advanced engineering and manufacturing techniques including 3D printing, high stability mirror mounts, and a novel alignment procedure. Absolutely calibrated, spatially resolved Ly-a brightness measurements utilize a bright, isolated line with low parasitic surface reflections and enable quantitative comparison to modeling to study divertor neutral leakage, main chamber fueling and radial particle transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗