Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CALORIMETRY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Energetics of Au Adsorption and Film Growth on Pt(111) by Single-Crystal Adsorption Calorimetry

Bimetallic catalysts are an important class of heterogeneous catalysts with catalytic properties distinct from either of their bulk metal constituents. The structural, electronic, chemisorptive, and catalytic properties of bimetallic surfaces have been widely studied. Surface reactivity often correlates with adsorption energy of one metal on a single-crystal surface of the other as measured using temperature-programmed desorption (TPD). However, TPD only works for systems where the metals are immiscible. For bimetallic systems that form an alloy or intermetallic compound, TPD generally fails because the adsorbed metal penetrates into the bulk upon heating. The metal-on-metal adsorption energy is unmeasured for all but one such system previously but often calculated because these adlayers often have interesting catalytic properties. We report here calorimetric measurements of the adsorption energy versus coverage of an adlayer of one metal on another for such a bimetallic system, where the metals prefer to alloy: Au on Pt(111). This bimetallic combination is important in catalysis and electrocatalysis. The first monolayer (ML) of Au grows pseudomorphically with the Pt(111) surface at 300 K, with an average heat of adsorption of 389, ~21 kJ/mol greater than the bulk heat of sublimation of Au. The heat increases with coverage by ~11 kJ/mol in the first 0.03 ML and then by another ~2 kJ/mol up to a maximum of 395 kJ/mol at 0.7 ML, and it then decreases to near the bulk heat of sublimation (368 kJ/mol) at 1 ML. The increase in heat is attributed to the increase in size of the two-dimensional Au islands that nucleate at a very low coverage and their corresponding increase in the average number of Au–Au nearest neighbor bonds. The high-coverage decrease in heat is attributed to the buildup of strain associated with the 4% Au/Pt lattice mismatch. Finally, the second and possibly third layers of Au show similar but much smaller oscillations in heat around 370 kJ/mol, attributed to the same two effects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Size-Dependent Energy and Adhesion of Pd Nanoparticles on Graphene on Ni(111) by Pd Vapor Adsorption Calorimetry

Carbon-supported late transition-metal nanoparticles are promising catalysts and electrocatalysts for wide-ranging applications. However, experimental investigations of the bonding energetics of metal nanoparticles on carbon supports are very limited. Here, in this work, we report heats of adsorption of Pd vapor deposited onto single-layer graphene(0001) supported on Ni(111) at 100 and 300 K as Pd grows particles of well-defined size in the range from three atom clusters to 6 nm diameter. Sizes were determined from He + low-energy ion scattering (LEIS). In this size range, the differential heat of Pd adsorption increases from 228 kJ/mol to within 10 kJ/mol of the heat of sublimation of bulk Pd (377 kJ/mol). The chemical potential of metal atoms in these nanoparticles as a function of average particle size was determined from these results. The adhesion energy at the Pd/graphene(0001)/Ni(111) interface was extracted from these data and found to be 3.5 J/m 2 for the largest Pd particles. For the three metal elements that have now been studied (Pd, Ni, and Ag), we found an increase in metal/graphene(0001)/Ni(111) adhesion energy with metal carbophilicity, which we defined here as the heat of C atom adsorption on that metal’s (111) surface estimated from published density functional theory calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Adhesion Energies of Solvent Films to Pt(111) and Ni(111) Surfaces by Adsorption Calorimetry

Solvent/metal adhesion energies are vital to understanding solvent effects on adsorption energies, which are, in turn, central to understanding liquid-phase catalysis, electrocatalysis, and many other technologies such as adsorption-based separations and chemical sensors. Differences in reactant adsorption energies in different solvents are dominated by differences in their solvent/metal adhesion energies. Here, the adhesion energies of five liquid solvents to clean Pt(111) and Ni(111) surfaces have been estimated using ultrahigh vacuum calorimetric measurements of heats of adsorption versus coverage integrated from zero coverage up to thick (bulk-like) multilayer solid films. The adhesion energies are found to vary from 0.15 to 0.60 J/m 2 , increasing in the trend CH 3 OH < HCOOH < H 2 O < benzene ≈ phenol. This trend suggests that solvents with higher heats of adsorption per unit area in the first adsorbed layer have higher adhesion energies to a given metal surface. The adhesion energies to Ni(111) are generally larger than to Pt(111) (on average by 0.09 J/m 2 ). This is due to the 24% higher number of metal atoms per unit area on Ni(111) than on Pt(111) and, with oxygen-containing solvents, the greater oxophilicity of Ni compared to that of Pt.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Strip-based Scintillation Detector for Dual-readout High-granularity Calorimetry

New calorimeter technology is being developed for future collider experiments. We are developing a calorimeter that integrates two technologies, a high-granularity calorimeter and a dual-readout calorimeter, and has high time resolution at a picosecond level. The proposed calorimeter is a sampling calorimeter based on scintillation and Cherenkov detectors with high-granularity readout. The Cherenkov detector has a picosecond level time resolution. For the high-granularity scintillation detector, scintillator strips of 300mm × 30mm ×3mm-thick are aligned horizontally and vertically to realize an effective 30mm-square-cell segmentation. Prototype strips with different designs and scintillator materials were tested to compare the performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LuAG:Ce fibers for high energy calorimetry

The main objective of this contribution is to point out the potentialities of cerium doped LuAG single crystal as pixels and fibers. We first show that after optimization of growth conditions using Bridgman technology, this composition exhibits very good performances for scintillating applications (up to 26 000 photons/MeV). When grown with the micropulling down technology, fiber shapes can be obtained while the intrinsic performances are preserved. For the future high energy experiments requiring new detector concepts capable of delivering much richer informations about x- or gamma-ray energy deposition, unusual fiber shaped dense materials need to be developed. We demonstrate in this frame that cerium doped LuAG is a serious candidate for the next generation of ionizing radiation calorimeters.

36 MATERIALS SCIENCE↗

Very Forward Calorimetry at the LHC--Recent results from ATLAS

We present first results from the ATLAS Zero Degree Calorimeters (ZDC) based on 7 TeV pp collision data recorded in 2010. The ZDC coverage of {+-}{approx}350 {mu}rad about the forward direction makes possible the measurement of neutral particles (primarily {pi}{sup 0}'s and neutrons) over the kinematic region x{sub F} > or approx. 0.1 and out to p{sub T} < or approx. 1.2 GeV/c at large x{sub F}. The ATLAS ZDC is unique in that it provides a complete image of both electromagnetic and hadronic showers. This is illustrated with the reconstruction of {pi}{sup 0}'s with energies of 0.7-3.5 TeV. We also discuss the waveform reconstruction algorithm which has allowed good time-of-flight resolution on leading neutrons emerging from the collisions despite the sparse (40 MHz) sampling of the calorimeter signals used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LC-circuit calorimetry

We present a new type of calorimeter in which we couple an unknown heat capacity with the aid of Peltier elements to an electrical circuit. The use of an electrical inductance and an amplifier in the circuit allows us to achieve autonomous oscillations, and the measurement of the corresponding resonance frequency makes it possible to accurately measure the heat capacity with an intrinsic statistical uncertainty that decreases as {approx}t{sub m}{sup -3/2} with measuring time t{sub m}, as opposed to a corresponding uncertainty {approx}t{sub m}{sup -1/2} in the conventional alternating current method to measure heat capacities. We have built a demonstration experiment to show the feasibility of the new technique, and we have tested it on a gadolinium sample at its transition to the ferromagnetic state.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrated plasma facing component calorimetry for measurement of shot integrated deposited energy in the NSTX-U

Here, the upgrade to the National Spherical Torus eXperiment (NSTX-U) increases the injected neutral beam power up to 12 MW and the plasma current up to I p = 2 MA for plasma durations up to 5 s. The graphite plasma facing components have been re-designed to handle greater heat and energy fluxes than were seen in NSTX using a castellated design. We present the experimental testing and validation of a castellated graphite target, similar to the prototype tile design, instrumented with thermocouples at various depths in the castellation. During testing, incident heat flux is provided by a programmed electron beam system and surface temperatures are measured via infrared thermography directly viewing the target surface. It was found that the thermocouple response scaled linearly with the measured surface temperature rise regardless of thermocouple depth in the castellation. A sensitivity of 14.3 °C/kJ of deposited energy was found when treating individual castellations as a semi-infinite solid.

47 OTHER INSTRUMENTATION↗

Precision Timing with Silicon Sensors for Use in Calorimetry

The high luminosity upgrade of the Large Hadron Collider (HL-LHC) at CERN is expected to provide instantaneous luminosities of 5 × 10 34 cm -2 s -1 . The high luminosities expected at the HL-LHC will be accompanied by a factor of 5 to 10 more pileup compared with LHC conditions in 2015, causing general confusion for particle identification and event reconstruction. Precision timing allows to extend calorimetric measurements into such a high density environment by subtracting the energy deposits from pileup interactions. Calorimeters employing silicon as the active component have recently become a popular choice for the HL- LHC and future collider experiments which face very high radiation environments. We present studies of basic calorimetric and precision timing measurements using a prototype composed of tungsten absorber and silicon sensor as the active medium. We show that for the bulk of electromagnetic showers induced by electrons in the range of 20 GeV to 30 GeV, we can achieve time resolutions better than 25 ps per single pad sensor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies of time resolution, light yield, and crosstalk using SiPM-on-tile calorimetry for the future Electron-Ion Collider

We recently proposed a high-granularity calorimeter insert for the Electron-Ion Collider (EIC) that is based on plastic scintillator tiles readout with silicon photomultipliers. In this work, we concretize its design by characterizing its building blocks with measurements of light yield, optical crosstalk, and timing resolutions using cosmic-rays, an LED, and a beta source. We also compared two approaches for the optical isolation of cells: "megatiles" with grooved boundaries between cells, and a 3D-printed plastic frame hosting individual cells. Further, we found that the latter suppresses optical crosstalk to negligible levels while providing an easier assembly method. Overall, these performance studies can help inform calorimeter design and realistic simulations of 5D showers (time, energy, position) for the EIC and other experiments.

47 OTHER INSTRUMENTATION↗