Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Building simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Conformational and oligomeric states of SPOP from small-angle X-ray scattering and molecular dynamics simulations

Speckle-type POZ protein (SPOP) is a substrate adaptor in the ubiquitin proteasome system, and plays important roles in cell-cycle control, development, and cancer pathogenesis. SPOP forms linear higher-order oligomers following an isodesmic self-association model. Oligomerization is essential for SPOP’s multivalent interactions with substrates, which facilitate phase separation and localization to biomolecular condensates. Structural characterization of SPOP in its oligomeric state and in solution is, however, challenging due to the inherent conformational and compositional heterogeneity of the oligomeric species. Here, we develop an approach to simultaneously and self-consistently characterize the conformational ensemble and the distribution of oligomeric states of SPOP by combining small-angle X-ray scattering (SAXS) and molecular dynamics (MD) simulations. We build initial conformational ensembles of SPOP oligomers using coarse-grained molecular dynamics simulations, and use a Bayesian/maximum entropy approach to refine the ensembles, along with the distribution of oligomeric states, against a concentration series of SAXS experiments. Our results suggest that SPOP oligomers behave as rigid, helical structures in solution, and that a flexible linker region allows SPOP’s substrate-binding domains to extend away from the core of the oligomers. Additionally, our results are in good agreement with previous characterization of the isodesmic self-association of SPOP. In the future, the approach presented here can be extended to other systems to simultaneously characterize structural heterogeneity and self-assembly.

59 BASIC BIOLOGICAL SCIENCES↗

Resilient cooling through geothermal district energy system

Decarbonization and resilience to heat waves have recently become high priorities for building and district energy systems. Geothermal coupled district heating and cooling systems that operate a water loop near ground temperature gain increasing adoption to support decarbonization. In these systems, vapor-compression machines, distributed in the energy transfer stations, lift the temperature up or down to the needs of the particular building. In principle, these systems can provide low-power, free cooling from the geothermal bore field during heat waves when electricity is often scarce. However, the performance of such a resilience operation mode and its implication on the energy system configuration and the sizing of the bore field and HVAC equipment is not yet understood. Consequently, we are assessing their resilience, power use and design implications under a scenario of a heat wave on five working days during which chillers are switched off to reduce electrical consumption. Our analysis is based on high-fidelity, coupled dynamic models of district energy, building-side HVAC and actual control logic, with whole building energy simulation used to assess thermal conditions in a 2004 vintage multi-zone office building in Chicago, IL. The results show that relying only on waterside economizer cooling, the indoor thermal conditions can be maintained in a tolerable range for the majority of the building zones with half the electrical energy compared to standard chiller operation. Thermal comfort in the hottest zones can be further improved by oversizing the cooling coil. However, the waterside economizer has significant implications on the system configuration and sizing: The geothermal bore field needs to be sized about 30% larger than the upper limit of the range observed for conventional geothermal systems. Nevertheless, if a central chiller plant is added, the bore field can be downsized to the typical design range. The latter configuration still allows compressor-less cooling during the heat wave with peak power reduced by 60% compared to the standard design and chiller operation.

15 GEOTHERMAL ENERGY↗

ComStock Measure Scenario Documentation: Chiller Replacement

Building on a 3-year effort to calibrate and validate the U.S. Department of Energy's ResStock (TM) and ComStock (TM) models, this work produces national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual energy consumption (at a subhourly resolution) of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. The goal of this work is to develop energy efficiency and demand flexibility end-use load shapes that cover high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to various "what-if" scenarios that can be applied to buildings. An end-use savings shape is the difference in energy consumption between a baseline building (or collection of buildings) and a building with an energy efficiency or demand flexibility measure applied. It results in a time-series profile broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step, as well as annual aggregations. This report describes the modeling methodology for a single end-use savings shape measure - chiller replacement - and briefly introduces key results. The full public dataset can be accessed on the ComStock (TM) data lake or via the Data Viewer at comstock.nrel.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Market Driven Residential Energy Codes: Comparing Performance in a Changing Technological Environment

The research project is undertaken to better understand the changing relationship between the two basic methods of building energy code compliance – prescriptive and performance – and how those methods relate to each other with respect to advancements in building energy computer simulation standards and capabilities. The International Energy Efficiency Code (IECC) is a model code adopted by many jurisdictions across the United States. Historically, the prescriptive compliance methodology has been preferred in most jurisdictions. The prescriptive methodology requires meeting or exceeding specific efficiency minimums for each envelope component. This tends to be a simple method to teach and verify. A more involved prescriptive alternative called the Total UA alternative is sometimes used. This method requires some multiplication, summing, and comparison to compute, so it is done with a fairly simple computer program. However, advances in computer and building energy simulation technology have resulted in increased use of more detailed performance compliance methods. The performance compliance method establishes the annual energy cost threshold via hourly simulation models. The compliance threshold is determined with a comparison building model simulation with geometry similar to the proposed home and with energy feature parameters and efficiencies as specified in the IECC. This project examines relationships between the two methods of building energy code compliance, including: • Overall annual energy use based on utility bill analysis by compliance method • Code official work processes with respect to compliance methods • Gaps and issues associated with building code compliance methods • Simulated energy use difference between compliance methods • Code compliance cost as a function of compliance method • Code compliance labeling effectiveness for high performance residences • Getting to net zero energy use and net zero greenhouse gas emissions through high performance code alternatives • Electronic code permitting and compliance alternatives

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Potential impact of work from home jobs on residential energy bills: A case study in phoenix, AZ, USA

Nearly one-third of U.S. households face challenges paying energy bills. During the day, many residents have routine access to cooled environments provided by others—employers, shopping centers, and other public buildings. The COVID-19 pandemic, however, has significantly shifted the cost burden of air conditioning in hot cities. Specifically, during the pandemic, many companies either laid off employees or put them in work-from-home (WFH) assignments. Large tech companies are already promoting WFH as a long-term option for their employees, even after the pandemic. This change in the nature of the workforce might reduce daily travel expenses for workers, but could also significantly increase residential energy bills, particularly during summer in very hot climates. Here, this study uses building energy simulations to quantify the potential residential energy bill penalties resulting from WFH for typical residences in Phoenix. Four building archetypes are used in this study to represent variations in building vintage, occupancy, and characteristics. The results show that, for some single-family residences in Phoenix, WFH can increase annual energy bills by more than $1100 (up to a 70% increase). The study also demonstrates that building performance enhancement retrofit measures have the potential to reduce this WFH energy bill penalty for the existing buildings substantially.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Occupant-Centric key performance indicators to inform building design and operations

Building performance indicators are widely used to guide building design and track and benchmark operational performance. Traditional building performance indicators mostly focus on the energy efficiency perspective. As occupants are the primary building service recipients in residential and most commercial buildings, their comfort and wellbeing are crucial. As such, this study first identified significant attributes of occupant-centric key performance indicators (KPIs) and analyzed the diverse factors that should be considered in formulating an occupant-centric KPI. Then a suite of occupant-centric KPIs were synthesized from the review and enhancement of existing occupant-related performance metrics. The proposed occupant KPIs represent the occupant lens on three integrative aspects of building performance: resource use (including energy and water), indoor environmental quality, and human–building interactions. A simulation-based case study was conducted to demonstrate how occupant-centric KPIs can be used to quantify the impacts of building operation changes from the occupants’ point of view. Highlights: Occupant-centric metrics are currently ad hoc and limited, yet crucial to inform building design and operations. Literature was reviewed to reveal the state-of-the-art and gaps of occupant-centric metrics. A suite of occupant-centric key performance indicators (KPIs) covering five groups of building services were synthesized. Proposed occupant KPIs represent three aspects of performance: resource use and demand, occupant comfort and health, and human–building interactions. A case study using whole building simulation was conducted to demonstrate the use of occupant-centric KPIs in evaluating building operations during a power outage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A digital twin platform for building performance monitoring and optimization: Performance simulation and case studies

Advancements in sensor technology, data analytics, affordable compute, and communication infrastructure have paved the way for Digital Twin technology in optimizing building operations and controls. This study presents the development of an open and interoperable web-based Digital Twin platform for integrating diverse data streams and facilitating effective user interactions. The platform utilizes modern technologies for the web framework and time-series data management, ensuring scalability and responsiveness. The backend supports seamless integration of diverse data sources and emulators, incorporating data from building sensors and meters, external weather Application Programming Interfaces, and advanced EnergyPlus simulation models of the building and its energy systems including the Distributed Energy Resources that are formulated in Functional Mockup Units. A simulation case study was conducted with FlexLab, a test facility on Lawrence Berkeley National Laboratory campus. The case study includes normal operations, Distributed Energy Resource integration, and power outage scenarios, to illustrate the Digital Twin’s ability to provide critical insights into energy performance and thermal resilience. The results demonstrated the platform’s potential as a decision-support tool for optimizing building energy performance and enhancing resilience against extreme weather events. Future work will focus on deploying the Digital Twin platform to a real building for field validation, extending its capabilities to cover more scenarios such as bidirectional Electric Vehicle interactions, and enhancing user engagement.

EnergyPlus↗

Data Reliability in BIM and Performance Analytics: A Survey of Contemporary AECO Practice

As awareness around building energy consumption increases, practitioners are encouraged to consider performance aspects regarding the built environment more closely and find ways to improve its efficiency. Improvements in building information modeling (BIM) and building performance simulation (BPS) tools present opportunities to facilitate information communication with a wider range of stakeholders. The building sector can benefit from the integration of performance informatics; however, there has been limited success in utilizing available technologies that promote data integration and management in favor of enriching our knowledge and understanding of buildings as artifacts of information. This phenomenon was investigated by conducting a survey, together with a review of relevant literature, to depict the relevant challenges and opportunities for the architecture, engineering, construction, and owner-operated (AECO) industry, as it undergoes digital transformation, as well as the working practices that have formed around them. It is argued that the current tools available to practitioners do not support effective data serialization between design and analytics processes, affecting the collaboration between team members. Lastly, a series of functional goals are proposed to support a higher level of reliability in the ways information is mobilized, by rethinking the technologies and methods for organizing information systems.

42 ENGINEERING↗

Estimating internal moisture generation rates in recently constructed, occupied homes in the southeastern United States

Internal moisture generation (IMG), or moisture generated by building occupants via activities such as respiration, cooking, bathing, and cleaning, is a critical input required for design, analysis, and simulation of building enclosure and heating, ventilation, and air conditioning (HVAC) systems. Based on previously published values, ASHRAE Standard 160-2021 provides guidance for estimating IMG rates for moisture control design analysis, which is based on occupied home datasets collected in the 1980s and 1990s. Residential energy use simulation software also utilizes estimates for IMG for energy rating, energy analysis, and code compliance calculations, as specified in ANSI/RESNET/ICC Standard 301. Data quantifying IMG rates in newer homes is useful in determining the continued relevance of current design and simulation guidance, and whether the guidance represents conditions found in new housing stock. ASHRAE Research Project 1844, conducted by the Florida Solar Energy Center (FSEC), a research institute of the University of Central Florida, estimated IMG rates in newer occupied homes built since 2013 in the southeastern US using a moisture balance model approach. Furthermore, the project obtained occupied home data in cooperation with a US Department of Energy Building America research project to characterize indoor air quality (IAQ) in newer US homes, along with presence, functionality, and occupant use of control measures. Full-scale laboratory homes operating with known IMG rates were used to validate a moisture balance model and quantify the accuracy of estimates obtained when the model is applied to data from occupied homes with unknown IMG rates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Comprehensive Analysis of Energy and Daylighting Impact of Window Shading Systems and Control Strategies on Commercial Buildings in the United States

Commercial buildings consume approximately 1.9 EJ of energy in the United States, 50% of which is for heating, cooling, and lighting applications. It is estimated that windows contribute up to 34% of the energy used for heating and cooling. However, window retrofits are not often undertaken to increase energy efficiency because of the high cost and disruptive nature of window installation. Highly efficient window technologies would also need shading devices for glare prevention and visual comfort. An automated window shading system with an appropriate control strategy is a technology that can reduce energy demand, maintain occupant comfort, and enhance the aesthetics and privacy of the built environment. However, the benefits of the automated shades currently used by the shading industry are not well studied. The topic merits an analysis that will help building owners, designers and engineers, and utilities make informed decisions using knowledge of the impact of this technology on energy consumption, peak demand, daylighting, and occupant comfort. This study uses integrated daylight and whole-building energy simulation to evaluate the performance of various control strategies that the shading industry uses in commercial office buildings. The analysis was performed for three different vintages of medium office buildings at six different locations in United States. The results obtained show the control strategies enabled cooling energy savings of up to 40% using exterior shading, and lighting energy savings of up to 25%. The control strategies described can help building engineers and researchers explore different control methods used to control shading in actual buildings but rarely discussed in the literature. This information will give researchers the opportunity to investigate potential improvements in current technologies and their performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lifting the Garage Door on Spawn, An Open-Source BEM-Controls Engine

Spawn is the latest whole-building energy simulation engine developed by the US Department of Energy, National Labs and industry. Whereas EnergyPlus was designed as a successor to DOE-2, Spawn is not a direct successor of–nor is it intended as an imminent replacement for– EnergyPlus. Instead, Spawn reuses parts of EnergyPlus while supporting new use cases in HVAC and controls. Spawn is intended to provide several capabilities that significantly advance beyond EnergyPlus. It is intended to support the evaluation of novel HVAC and district energy systems in a more physically realistic way. Critically, it can model control in a physically realistic way, using portable specifications that can be compiled for execution on control platforms. Spawn is also intended to support co-simulation in an intrinsic way to enable integration with third-party models. This paper describes the software architecture of Spawn from model authoring to compilation and simulation. It explains how Spawn reuses the envelope and daylighting modules of EnergyPlus and couples them to HVAC and control models from the Modelica Buildings Library using the Functional Mockup Interface (FMI) standard. It presents a number of examples that: i) validate Spawn’s coupled simulation approach by comparing its results to those of EnergyPlus, ii) illustrate the Spawn methodology for modeling and simulating HVAC systems, and iii) evaluate the performance of Spawn’s Quantized State System (QSS) time integration algorithms

Wetter, Michael↗

The role of air sealing while ground source heat pump system retrofits in the U.S. single-family houses

Widespread commercial adoption of ground source heat pumps (GSHP) is hindered by the relatively high initial cost associated with drilling boreholes in the ground to deploy ground heat exchangers. Reducing the energy demand of buildings has the potential to reduce the required borehole length and the associated drilling costs. In single-family residential buildings, air sealing can significantly lower heating energy usage, according to recent studies and reports. Thus, air sealing in conjunction with GSHP retrofits can lower the required GSHP system's capacity and borehole length to meet the thermal demands of the buildings. In order to understand the role of combining air sealing with GSHP retrofit quantitatively, the current study employs a whole building energy simulation tool integrated with an advanced design tool for the ground heat exchanger to determine changes in required GSHP capacity, total borehole length, and building energy consumption for with- and without-air sealing in single-family houses in 3 climate zones in the United States. The study considers one representative city for each climate zone, Phoenix, AZ for a hot climate, Seattle, WA for a moderate climate, and Minneapolis, MN for a cold climate. The results from this study show that reducing air infiltration from 0.8 ACH to the minimum ventilation requirement (0.35 ACH) can reduce borehole length requirement by up to 24% in Phoenix, 32% in Seattle, and 70% in Minneapolis. A similar magnitude of reduction can be seen for GSHP capacity and total building energy usage as well.

Prem Anand Jayaprabha, Jyothis Anand↗

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing the impacts of air-sealing on the sizing, operation, and economic feasibility of ground-source heat pumps for electrifying single-family houses in the US

According to recent studies and reports, in single-family houses (SFHs), air-sealing can significantly lower the thermal loads for space heating and cooling. Thus, air-sealing in SFHs could reduce the required size and cost of ground source heat pump (GSHP) systems for electrifying SFHs. Here, this study investigated the costs and benefits of integrating air-sealing with GSHPs for retrofitting existing SFHs when compared with air-source heat pumps. A whole building energy simulation tool integrated with an advanced design tool for modeling ground heat exchangers was used to calculate changes in required GSHP capacity, total borehole length, and building energy consumption with and without air-sealing in SFHs in 16 US climatic regions. The results from this study showed that reducing outdoor air infiltration from 0.8 air changes per hour (ACH) to the minimum ventilation requirement (0.35 ACH) can significantly reduce borehole length (up to 55 %), GSHP capacity (up to 48 %), and total heating electricity reduction, especially in cold climates (up to 44 %). The results also showed that for airtight homes (0.03 ACH infiltration) with a direct outdoor air system, the minimum required borehole length, GSHP capacity, and total heating electricity consumption can be reduced up to 70 %, 68 %, and 67 %, respectively, when compared with SFHs with 0.8 ACH infiltration. Moreover, the life cycle cost analysis showed that air-sealing in conjunction with a GSHP is more profitable than replacing the existing system with an air-source heat pump, even without any incentives for most climatic regions in the US (except for some hot regions).

15 GEOTHERMAL ENERGY↗

Performance Assessment of the Overall Building Envelope Thermal Performance—Building Envelope Performance (BEP) Metric

Today, to describe the thermal performance of the building envelope and its components we use a variation of metrics; such as, R-value, ACH (air exchange rate per hour), SHGC (solar heat gain coefficient) of windows, U-factor etc. None of these performance indicators is meant to represent the overall thermal performance. In this paper, such a metric is introduced, the BEP (building envelope performance) value. Unlike the thermal resistance, typically expressed as an R-value, the BEP-value considers additional elements of heat transfer that affect the energy demand of the building because of exterior and interior (solar) thermal loads: conductive and radiant heat transfer, and air infiltration. To demonstrate BEP’s utility, validation studies were carried out by comparing the BEP-value to theoretical results using whole building energy simulation tools such as EnergyPlus and WUFI Plus. Results show that BEP calculations are comparable to calculations made using these simulation tools and that unlike other similar metrics, the BEP-value accounts for all heat transfer mechanisms that are relevant for the overall energy performance of the building envelope. The BEP-value thus allows comparing envelopes of buildings with different use types in a fair and realistic manner.

42 ENGINEERING↗

High-Fidelity Building Emulator for Integrated Comfort and Energy Analysis using EnergyPlus and Radiance

The growing need for smart, energy-efficient, and occupant-centric buildings has created a demand for advanced control systems that can optimize building operations to balance energy savings, demand flexibility, and comfort. However, current building energy simulation tools, such as EnergyPlus, have limitations that hinder the development and evaluation of these complex control systems. To address this challenge, we introduce a high-fidelity building emulator that dynamically couples EnergyPlus with Radiance for enhanced daylight modeling. The introduced workflow allows researchers and practitioners to rapidly develop and evaluate innovative control solutions. An example study looking at a south-facing office zone revealed up to 67% deviation in predicted light levels, which can significantly impact building assessment.

Yu, Tammie↗

Extreme variation in fatigue: Fatigue life prediction and dependence on build volume location in laser powder bed fusion of 17-4 stainless steel

Laser powder bed fusion (LPBF), a metal additive manufacturing technology, is well-suited for design optimization but fatigue life is limited by manufacturing defects. In this work, 17-4 stainless steel components were manufactured in densely populated build volumes, simulating at-scale LPBF production. Tests revealed extreme variability in fatigue life data, analyzed via rigorous statistical tools. The El-Haddad model, modified for finite-life, enabled defect-based life prediction. Specimen location within the build volume correlated to life, which was heteroscedastic. Investigating defect concentration over the build volume explained typical life and scatter. Finally, these findings argue for qualification approaches which acknowledge high material lot variability.

36 MATERIALS SCIENCE↗