Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Building automation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

pnnl/openstudio-building-energy-standard-measures-gem

The OpenStudio Building Energy Standards Measure Repository is a comprehensive collection of innovative OpenStudio measures designed to facilitate energy code analysis. OpenStudio is a cutting-edge platform brings together physics-based building energy modeling (BEM), BEM process automation, and large-scale computing capabilities. Contains OpenStudio Standards Performance Rating Method Measure (IPID 32936) and OpenStudio Measure to Generate IPLV-specific Chiller Performance Curves for Chillers (IPID 32940)

Xu, Weili [PNNL]↗

AI for Science: Report on the Department of Energy (DOE) Town Halls on Artificial Intelligence (AI) for Science

The report documents the DOE Town Halls held during 2019 at Argonne National Laboratory, Oak Ridge National Laboratory, Lawrence Berkeley National Laboratory, and in Washington, DC. From July to October 2019, the Argonne, Oak Ridge, and Berkeley National Laboratories hosted a series of four town hall meetings attended by more than 1,000 U.S. scientists and engineers. The goal of the town hall series was to examine scientific opportunities in the areas of artificial intelligence (AI), Big Data, and high-performance computing (HPC) in the next decade, and to capture the big ideas, grand challenges, and next steps to realizing these opportunities. In this report and in the Department of Energy (DOE) laboratory community, we use the term “AI for Science” to broadly represent the next generation of methods and scientific opportunities in computing, including the development and application of AI methods (e.g., machine learning, deep learning, statistical methods, data analytics, automated control, and related areas) to build models from data and to use these models alone or in conjunction with simulation and scalable computing to advance scientific research. The AI for Science town hall discussions focused on capturing the transformational uses of AI that employ HPC and/or data analysis, leveraging data sets from HPC simulations or instruments and user facilities, and addressing scientific challenges unique to DOE user facilities and the agency’s wide-ranging fundamental and applied science enterprise.

36 MATERIALS SCIENCE↗

Design, Development and Testing Plan for Energy Efficiency Algorithms Related to Building-Integrated Cooling, Heating, and Power Systems

Building-integrated cooling, heating and power (CHP) systems are more efficient than conventional systems at providing local power and thermal energy, and favorable fuel prices are bound to spur their increased adoption. It is estimated that the total CHP technical potential in the commercial building sector is approximately 76 GW, but only a small fraction of it is actually deployed. Advanced control and monitoring systems that realize the full potential of these CHP systems can transform this capacity into an asset for both the owner and the grid and also accelerate the adoption of these systems in the building sector. However, to realize the full benefit of the CHP systems, we must ensure persistence of energy efficient operations. It has been demonstrated by several studies that as much as 30% of building energy use is wasted. Much of the waste results from the inability to anticipate load variations (design day vs. non-design day operations; diurnal variation of loads), identify improper operation, and efficiently operate, control and maintain building systems. Moreover, many buildings, even those with adequate control infrastructure, lack knowledgeable staff to operate and maintain energy systems. Operators of buildings with CHP systems will constantly need to make tradeoffs (economic dispatch) between onsite power generation and purchasing power, between onsite heat production from distributed generation versus heating/cooling from conventional systems, and different passive and active load management measures. Much of the inefficiency in the current building operations can be eliminated by use of automated performance monitoring (PM), real-time commissioning verification (CxV) and automated fault detection and diagnostic (AFDD) tools. Automation can help system operators make intelligent decisions. Remote and continuous monitoring of system conditions and performance will enable better management and integration of CHP with existing building systems. Continuous PM, real-time CxV and AFDD could alleviate burdens for operations staff, enhance operations and maintenance (O&M), and improve reliability of building and CHP systems. To address the O&M challenges and to provide a means to maximize the rate-of-return of building-integrated CHP systems, the Building Technologies Office (BTO) within the U.S. Department of Energy’s (DOE’s) Office of Energy Efficiency and Renewable Energy (EERE) initiated a project to design, develop, and field test a VOLTTRON™-based supervisory controller and associated open-source algorithms. These algorithms will ensure real-time optimal operation of a building-integrated CHP system, support electric grid reliability, and lead to achieving the goal of a clean, efficient, reliable and affordable next-generation integrated energy systems. This report lists the components for which PM, real-time CxV and AFDD algorithms will be developed, how the algorithms will be tested, and metrics that will be used to validate the algorithms and easy of deployment. Deployment of these algorithms in the field will result in savings reduction in energy consumption of between 10% and 20%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Implementation Plan for Combined Heat and Power Systems VOLTTRON Controller: Performance Monitoring and Real-Time Commissioning Algorithm Verification

Building-integrated cooling, heating, and power (CHP) systems are more efficient than conventional systems at providing local power and thermal energy, and favorable fuel prices are bound to spur their increased adoption. However, to realize the full benefit of the CHP systems, we must ensure persistence of energy efficient operations. Much of the inefficiency in the current building operations can be eliminated by use of automated performance monitoring (PM), real-time commissioning verification (CxV) and automated fault detection and diagnostic (AFDD) tools. Automation can help system operators make intelligent decisions. Remote and continuous monitoring of system conditions and performance will enable better management and integration of CHP with existing building systems. Continuous PM, real-time CxV, and AFDD could alleviate burdens for operations staff, enhance operations and maintenance (O&M), and improve reliability of building and CHP systems. To address the O&M challenges and to provide a means to maximize the rate-of-return of building-integrated CHP systems, the Building Technologies Office (BTO) within the U.S. Department of Energy’s (DOE’s) Office of Energy Efficiency and Renewable Energy (EERE) initiated a project to design, develop, and field test a VOLTTRON™-based supervisory controller and associated open-source algorithms. These algorithms will ensure real-time optimal operation of a building-integrated CHP system, support electric grid reliability, and lead to achieving the goal of clean, efficient, reliable, and affordable next-generation integrated energy system. Previous report listed the components for which PM, real-time CxV, and AFDD algorithms will be developed, how the algorithms will be tested, and the metrics that will be used to validate the algorithms and their ease of deployment. Deployment of these algorithms in the field will result in a reduction in energy consumption of between 10% and 20% (for both CHP and conventional building systems). This report builds upon the previous report by detailing the process by which PNNL will implement performance monitoring and real-time commissioning algorithms for CHP systems in conjunction with the use of the VOLTTRON CHP economic dispatch agent in host facilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Open-Source Framework for Characterizing Urban Energy Models: Integrating Top-Down and Bottom-Up Methods to Predict Residential Buildings Characteristics: Preprint

Bottom-up urban energy models are crucial for understanding current energy use patterns and informing design strategies. However, accurately characterizing these models to represent different communities remains a challenge due to the extensive data needed for simulating existing energy use behavior. This data includes information related to human activities and building characteristics, all of which correlate with socioeconomic factors. To overcome this challenge, we developed an automated framework that utilizes both top-down and bottom-up data, to predict unknown building and occupant characteristics that are needed for more accurate and equitable modeling and analytics. Our framework, integrated into the URBANopt district energy modeling platform, uses statistical data models from ResStock. URBANopt models co-located buildings and neighborhoods. At this scale there are data gaps in building characteristic data, such as materials, insulation, occupancy, income, and energy usage of the buildings. To address this data gap, we use ResStock data, representative at the census tract scale, and develop machine-learning and deeplearning techniques to disaggregate it to individual buildings. By mapping unique occupant, building and economic properties to URBANopt energy models, we gain detailed insights into the variability of building energy use across different neighborhoods. This insight helps deploy technologies for co-located buildings and supports targeted upgrades for communities with unique economic and demographic characteristics, ensuring energy equity. Accurate characterization of energy models allows us to develop equitable strategies tailored to diverse neighborhoods, whether underserved or affluent. Our automated framework streamlines energy modeling and provides a reliable tool for building energy characterization.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Provider and User Perspectives on Automated Fault Detection and Diagnostic Products for Packaged Rooftop Units

The goal of this project was to understand, based on the primary reporting of AFDD providers and building owners, 1) the features currently available for RTU AFDD in the market today, 2) how RTU AFDD is used by building owners and managers, 3) how well RTU AFDD meets their needs, and 4) what barriers stand in the way of its broad industry adoption. To achieve this goal, 13 AFDD providers were asked about their products and seven building owners were questioned about their practical experience related to the automated detection, diagnosis, and communication of RTU faults.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstration and Validation of a Virtual Energy Audit Tool for DoD Buildings

Electricity consumption has been in the spotlight as part of the battle for sustainability resulting in legislative measures to try and reduce the amount of energy used. EISA 432 and the Energy Act of 2020 are two examples that require federal facilities to investigate buildings and find saving opportunities through energy audits. EDIFES solves this problem by providing fully virtual audits. Only five inputs are needed (15-minute interval electricity consumption, location, square footage, number of stories, and building end use) to produce complete energy audits. The virtual audit is automated, making them inexpensive and the small number of inputs allows a large number of buildings to be entered quickly. During this project, EDIFES performed energy audits on hundreds of buildings to ensure proper functionality and workflow. Over 250 DoD buildings received energy audits that then had their results posted to an interactive dashboard with portfolio rankings. Several validation methods were employed. All confirmed that EDIFES's methods worked as expected and with a high degree of accuracy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application and evaluation of a pattern-based building energy model calibration method using public building datasets

Building performance simulation has been adopted to support decision making in the building life cycle. An essential issue is to ensure a building energy simulation model can capture the reality and complexity of buildings and their systems in both the static characteristics and dynamic operations. Building energy model calibration is a technique that takes various types of measured performance data (e.g., energy use) and tunes key model parameters to match the simulated results with the actual measurements. This study performed an application and evaluation of an automated pattern-based calibration method on commercial building models that were generated based on characteristics of real buildings. A public building dataset that includes high-level building attributes (e.g., building type, vintage, total floor area, number of stories, zip code) of 111 buildings in San Francisco, California, USA, was used to generate building models in EnergyPlus. Monthly level energy use calibrations were then conducted by comparing building model results against the actual buildings' monthly electricity and natural gas consumption. The results showed 57 out of 111 buildings were successfully calibrated against actual buildings, while the remaining buildings showed opportunities for future calibration improvements. Enhancements to the pattern-based model calibration method are identified to expand its use for: (1) central heating, ventilation and air conditioning (HVAC) systems with chillers, (2) space heating and hot water heating with electricity sources, (3) mixed-use building types, and (4) partially occupied buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The good, the bad, and the ugly: Data-driven load profile discord identification in a large building portfolio

Reducing the overall energy consumption and associated greenhouse gas emissions in the building sector is essential for meeting our future sustainability goals. Recently, smart energy metering facilities have been deployed to enable monitoring of energy consumption data with hourly or subhourly temporal resolution. This unprecedented data collection has created various opportunities for advanced data analytics involving load profiles (e.g., building energy benchmarking programs, building-to-grid integration, and calibration of urban-scale energy models). These applications often need preprocessing steps to detect daily load profile discords, such as: 1) outliers due to system malfunctions (the bad) and 2) irregular energy consumption patterns, such as those resulting from holidays (the ugly) compared to normal consumption patterns (the good). However, current preprocessing methods predominantly focus on filtering using statistical threshold values, which fail to capture the contextual discords of daily profiles. In addition, discord detection algorithms in building research are often aimed at finding individual building-level discords, which are not suitable at a large scale. Thus, here, we develop a method for automated load profile discord identification (ALDI) in a large portfolio of buildings (more than 100 buildings). Specifically, ALDI 1) uses the matrix profile (MP) method to quantify the similarities of daily subsequences in time series meter data, 2) compares daily MP values with typical-day MP distributions using the Kolmogorov-Smirnov test, and 3) identifies daily load profile discords in a large building portfolio. We evaluate ALDI using the metering data of both an academic campus and a residential neighborhood. Our results demonstrate that ALDI efficiently discovers measurement errors by system malfunctions and low energy consumption days in the academic campus portfolio, and it detects unique load shape patterns likely driven by occupant behavior and extreme weather conditions in the residential neighborhood.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lab-Scale Cable-Driven Parallel Robot Prototype for Automated Prefabricated Component Manipulation

This paper presents the design and evaluation of a lab-scale cable-driven parallel robot (CDPR) developed as a flexible platform for automated installation of prefabricated components onto exterior building envelopes. Traditional manual installation methods for prefabricated components, which depend on scaffolding, cranes, cherry pickers, and verbal coordination, are not only labor-intensive and error-prone but also face significant limitations in dense urban environments due to site access constraints. To address these challenges, we developed a lab-scale CDPR platform capable of autonomously transporting building envelope components from a designated pickup zone to their target installation location, minimizing the need for human intervention. This study describes the system’s mechanical design, actuation architecture, real-time feedback system, and control strategy of the CDPR, and evaluates its performance in a laboratory environment. The robot’s actuation system uses torque control for end-effector manipulation. The robot’s real-time pose feedback comes from a construction-grade total station and a wireless inertial measurement unit (IMU), which together support precise end-effector control. Experimental results demonstrate the successful integration of the hardware, sensing, state estimation, and control subsystems. Preliminary tests showed that our lab-scale prototype can position the end effector with an error of less than 3 mm, which is a level of precision not previously achieved by existing CDPRs in construction applications. The key findings are twofold: (1) torque-only control is necessary but not sufficient for minimizing final pose error, and (2) incorporating real-time pose feedback can achieve the desired placement accuracy.

Liu, Yifang [Oak Ridge National Laboratory (ORNL),↗

stor4build

The EnergyPlus simulation engine supports modeling and simulation of thermal energy storage (TES) systems in several ways, including using the Python-EMS feature, which extends the operation of the engine with custom code written in Python. Creation of models using this feature can be tedious and error prone, with the connection of the model components to the Python code a particularly troublesome area. The stor4build Python package simplifies this process by modifying an input model to add a selected TES technology (implemented with the Python-EMS feature) and runs the simulation. The package leverages the OpenStudio middleware software development kit to automate this process as much as possible, eliminating potential errors and simplifying usage of EnergyPlus. The package provides objects, functions, and OpenStudio measures that implement the necessary operations to automate the creation of EnergyPlus models that integrate TES technologies with building systems. In addition, two user interfaces are provided: a command line interface and a web application programming interface. The automated process implemented by the package greatly simplifies the modeling and simulation process, allowing for parametric studies to be executed much more efficiently and effectively. The OpenStudio-based workflow is also very flexible and will allow for future additions of new technologies.

DeGraw, JasonWilliam [Oak Ridge National Laborator↗

Self-Driving Laboratory for Polymer Electronics

Owing to the chemical pluripotency and viscoelastic nature of electronic polymers, polymer electronics have shown unique advances in many emerging applications such as skin-like electronics, large-area printed energy devices, and neuromorphic computing devices, but their development period is years-long. Recent advancements in automation, robotics, and learning algorithms have led to a growing number of self-driving (autonomous) laboratories that have begun to revolutionize the development and accelerated discovery of materials. In this perspective, we first introduce the current state of autonomous laboratories. Then we analyze why it is challenging to conduct polymer electronics research by an autonomous laboratory and highlight the needs. Here, we further discuss our efforts in building an autonomous laboratory, namely Polybot, for the automated synthesis and characterization of electronic polymers and their processing and fabrication into electronic devices. Finally, we share our vision in using a self-driving laboratory for different types of polymer electronics research.

36 MATERIALS SCIENCE↗

A scoping review of non-destructive testing (NDT) techniques in building performance diagnostic inspections

Understanding building envelope thermodynamics is an essential foundation of building sciences, mainly due to the envelope’s role as a boundary layer for exterior environments, as well as a container and regulator of internal microclimates. This paper presents a scoping literature review of select Non-destructive Testing (NDT) techniques for building envelope scanning and surveying for thermodynamic diagnostics. The investigation focuses specifically on reviewing six NDT techniques: Ground Penetrating Radar (GPR), Light Detection and Ranging (LiDAR)/Laser Scanning, Thermography, Ultrasound, Close-Range Photogrammetry and Through Wall Imaging Radar (TWIR). The aim is to identify knowledge gaps in terms of their use in accurately characterizing envelope compositions for further integration in Building Energy Modeling (BEM). Each technique was evaluated according to set categories imbibed from the American Society of Heating, Refrigerating, and Air Conditioning Engineering (ASHRAE) Standard 211P that showcase the technique’s ability to extract various relevant information. A framework is then developed to inform users on how to use hybrid NDT-based workflows applied in building envelope energy audits. The study concludes by discussing possibilities of utilizing NDT in large-scale audit automation, BEM integration, and developing built environment policies focusing on increasing existing building performance through retrofitting design.

36 MATERIALS SCIENCE↗

lumicap v0.1

Automated HDR luminance imaging system designed for daylighting research and building science. It controls a fisheye-lens camera to capture time-lapse bracket sequences, merges them into calibrated HDR images, and runs a full post-processing pipeline — all unattended. Features: - Scheduled LDR bracket capture via gphoto2 - HDR merging with vignetting, ND filter, and fisheye projection corrections - Illuminance and luminance meter integration (Konica Minolta T-10A, LS-100/150) - Daylight glare probability (DGP) and solar position computation - Automated false-color rendering, JPEG thumbnails, and daily time-lapse video - CSV data logging per timestep Uses: - Long-term monitoring of daylight conditions in buildings - Glare analysis for occupant comfort research - Solar irradiance and sky luminance studies Advantages: - End-to-end automation — capture, calibration, analysis, and archiving run without manual intervention - Built on the proven Radiance toolchain, ensuring photometrically accurate HDR output - Hardware-agnostic meter support via serial auto-detection - Lightweight — no GUI overhead, deployable on a headless Raspberry Pi or similar embedded system

Wang, Taoning [Lawrence Berkeley National Laborato↗

Laboratory Validation of Integrated Lighting Systems Retrofit Performance and Energy Savings

Light-emitting diodes (LED) fixtures and lamps have emerged as leading technologies for general illumination and are a well-established energy efficiency retrofit measure in commercial buildings (from around 2% of installed fixtures and lamps in 2013 to 28% by 2020). Retrofit approaches that integrate elements, such as networked controls, daylight dimming, and advanced shade technologies lag in comparison. Integrated retrofits have been shown to increase savings over single end-use retrofits, but are perceived as higher complexity and risk. More validation of integrated lighting system performance is needed. This study presents results from laboratory testing of three packages combining fixtures, networked controls, task tuning, and daylight dimming, advanced shades, and lighting layout changes. We characterize performance in perimeter open-office zones, finding energy savings from 20% for daylight dimming and automated shades (no LED retrofit) to over 70% for LED retrofits with advanced controls and shades or lighting layout changes. We present some implementation details, including lessons learned from installation and commissioning in the laboratory setting. We also discuss cost-benefit analysis approaches for the types of packages presented, including the need to quantify and incorporate energy and non-energy benefits for advanced shades packages, which enhance occupant comfort but add significant cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Optimization-Based Planning Tool for On-Demand Mobility Service Operations

Regions worldwide are adopting and exploring low-speed automated electric shuttle (AES) service as an on-demand shared mobility service in dense geofenced urban areas. Building on this concept, the National Renewable Energy Laboratory (NREL) recently developed the Automated Mobility District (AMD) toolkit. The AMD toolkit—comprising of a travel micro-simulation model and an energy estimation model—estimates the mobility and energy impacts of a given shuttle configuration within an AMD. Early-stage AMD deployments need to find optimal operational configurations that include: (a) passenger capacity of an AES, (b) time-dependent routes, and (c) fleet size (AES units) to satisfy the demand for the region. This research extends the AMD toolkit functionality by developing an optimization-based planning module that will assist in the operations of AES units. We developed a constrained mixed-integer program accounting for passenger waiting time, battery range, and passenger capacity of AES units. For scalability, we demonstrated the Tabu search-based solution technique for a real-world network—a proposed AMD deployment in Greenville, South Carolina, USA. Compared to rule-based operations, our developed solution yields higher travel time and energy savings for the network at different demand levels. The sensitivity analyses for waiting time thresholds indicate nonlinearity in the system performance, underscoring the need to meet shared-use mobility user-level expectations. The developed optimization framework can be adapted and extended to accommodate different categories of shared-use on-demand mobility services.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

OpenStudio® HPXML workflow [SWR-25-13]

OpenStudio-HPXML allows running residential EnergyPlus™ simulations using an HPXML file for the building description. It is intended to be used by user interfaces or other automated software workflows that automatically produce the HPXML file. OpenStudio-HPXML can accommodate a wide range of different building technologies and geometries. End-to-end simulations typically run in 3-10 seconds, depending on complexity, computer platform and speed, etc. For more information on running simulations, generating HPXML files with the appropriate inputs to run EnergyPlus, etc., please visit the documentation linked below. https://openstudio-hpxml.readthedocs.io/en/latest

Horowitz, Scott↗

Maximizing Efficiency and Quality: Leveraging Automated Testing for Laboratory Commissioning

The traditional commissioning process uses sampling to select equipment for functional acceptance testing when large quantities of equipment are present. Although this approach is generally effective in identifying wide-spread issues, it has several shortcomings: it fails to evaluate equipment not included in the sample, provides only a one-time validation of equipment operation, and the standard documentation is a simple checklist of pass/fail questions. During the construction and commissioning process of the new Research and Innovation Laboratory (RAIL) in Golden, CO, the National Renewable Energy Laboratory team engaged Group14 Engineering to implement a Connected Commissioning process using fault detection and diagnostic software for automated functional acceptance testing. This presentation highlights the advantages offered by automated functional testing in this critical laboratory setting: (1) sampling 100% of BAS-connected equipment during functional testing, (2) testing results backed by data beyond the traditional pass/fail checklist, and (3) an automated test process that can be regularly executed by the building management team for ongoing commissioning throughout the life of the building. The presentation will also cover technical challenges associated with Connected Commissioning and the important conversations with key stakeholders that need to occur well before functional acceptance testing in order to successfully implement the automated testing processes.

automated testing↗