Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Brookhaven National Laboratory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

High figure of merit spin polarized electron sources grown via MOCVD

Spin polarized photocathodes are key to the future operation of electron accelerators such as the ones at Thomas Jefferson National Accelerator Facility and Brookhaven National Laboratory. Currently, these photocathodes come in short supply due to limited production by molecular beam epitaxy. By developing a process to implement similar structures using metal organic chemical vapor deposition, the availability of these devices can be increased. Here, in this paper, we detail the implementation of recent photocathode advancements via metal organic chemical vapor deposition process and show an improvement in both polarization and quantum efficiency of our devices compared to those fabricated via molecular beam epitaxy, with devices reaching 82% polarization and 2.9% quantum efficiency.

43 PARTICLE ACCELERATORS↗

Impact of superlattice size on quantum efficiency and polarization in MOCVD-grown strained GaAs/GaAsP photocathodes

Strained superlattice GaAs photocathodes are crucial for providing high photocurrent beams of spin-polarized electrons at several accelerator facilities including the Continuous Electron Beam Accelerator Facility at Thomas Jefferson National Accelerator Facility and the future Electron–Ion Collider at Brookhaven National Laboratory. Here, in this work, we study the effects of varying the number of superlattice pairs on the polarization and photocurrent of the photocathodes. We observe a saturation in quantum efficiency beyond 30 pairs, with additional layers yielding minimal photocurrent improvement while noticeably reducing the polarization of the beam.

Chemical vapor deposition↗

Nuclear Science for the Manhattan Project and Comparison to Today’s ENDF Data

Nuclear physics advances in the United States and Britain from 1939 to 1945 are described. The Manhattan Project’s work led to an explosion in our knowledge of nuclear science. A conference in April 1943 at Los Alamos provided a simple formula used to compute critical masses and laid out the research program needed to determine the key nuclear constants. In short order, four university accelerators were disassembled and reassembled at Los Alamos, and methods were established to make measurements on extremely small samples owing to the initial lack of availability of enriched 235U and plutonium. I trace the program that measured fission cross sections, fission-emitted neutron multiplicities and their energy spectra, and transport cross sections, comparing the measurements with our best understanding today as embodied in the Evaluated Nuclear Data File ENDF/B-VIII.0. The large nuclear data uncertainties at the beginning of the project, which often exceeded 25% to 50%, were reduced by 1945 often to less than 5% to 10%. Uranium-235 and plutonium-239 fission cross-section assessments in the fast mega-electron-volt range were reduced following more accurate measurements, and the neutron multiplicity $\overline{v}$ increased. By a lucky coincidence of canceling errors, the initial critical mass estimates were close to the final estimated masses. Some images from historical documents from our Los Alamos archives are shown. Many of the original measurements from these early years have not previously been widely available. Through this work, these data have now been archived in the international experimental nuclear reaction data library (EXFOR) in a collaboration with the International Atomic Energy Agency and Brookhaven National Laboratory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Synchrotron Catalysis Consortium (SCC) at NSLS-II: Dedicated Beamline Facilities for In Situ and Operando Characterization of Catalysts

The Synchrotron Catalysis Consortium (SCC) was funded and established in September 2005 at the National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory (BNL). For more than a decade, the SCC was the first of its kind in the United States, with a mission to promote the utilization of synchrotron techniques for cutting-edge catalysis research under in-situ conditions. The consortium consists of three Principal Investigators (Jingguang Chen, Columbia University, Anatoly Frenkel, Stony Brook University/BNL, and Jose Rodriguez, BNL) and scientific staff member Nebojsa Marinkovic. The initial team also included Radoslav Adzic, BNL, and collaborators from academic, national, and industrial laboratories. During the first decade of its operations at three NSLS beamlines (X18A, X18B, and X19A) until the closing of NSLS on September 30, 2014, the primary goal of the SCC team was to provide assistance and to develop new sciences/techniques to the catalysis community...This report outlines a brief history, specifications, techniques, and training and outreach for the facility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multimodal, Multidimensional, and Multiscale X-ray Imaging at the National Synchrotron Light Source II

Over the last couple of decades, the synchrotron radiation research community has witnessed tremendous advancement in the field of x-ray imaging and microscopy. Continuing enhancement of the light sources’ brightness, advances in x-ray focusing optics, incorporation of precision instruments, and development of innovative imaging techniques are some of the leading contributors for the rapid progress. New imaging and microscopy beamlines, such as the ones at the National Synchrotron Light Source II (NSLS-II), a Department of Energy (DOE) Office of Science user facility located at DOE’s Brookhaven National Laboratory, are capable of performing more sophisticated and complicated measurements than ever before, either on their own or used together as a suite of tools. These sophisticated and complex measurements exhibit attributes for multimodal, multidimensional, and multiscale imaging. Recent popularity of these methods is strongly driven by the current trends in materials characterizations, where researchers desire to map out hierarchical materials structure over a large range of length scales, to understand structure-property correlation, to quantify materials structures in 3D, and/or to perform operando or in situ experiments. It is important to emphasize that “materials” under investigation are not only synthesized materials but also the natural materials. In this article, we describe multimodal, multidimensional and multiscale x-ray imaging capabilities of the NSLS-II beamlines and how these methods are used to tackle complex scientific problems.

47 OTHER INSTRUMENTATION↗

Characterizing Hidden Structures at NSLS-II: Strongly Correlated Electron Systems, Functional Ceramics, Batteries, and Beyond

Brookhaven National Laboratory (New York) launched its highenergy X-ray science program at the inception of the National Synchrotron Light Source (NSLS), a U.S. Department of Energy (DOE) Office of Science User Facility. Built in the 1980s, the NSLS X17 beamline was the world’s first super-conducting wiggler facility and remained in service for more than 30 years. The NSLS facility was decommissioned in October 2014 and a third-generation synchrotron machine, DOE’s National Synchrotron Light Source II (NSLS-II), took over. Six years after completing construction, NSLS-II has a portfolio of 29 beamlines that includes two operating high-energy powder diffraction beamlines (XPD and PDF) and one high-energy imaging and diffraction beamline under construction (HEX).

36 MATERIALS SCIENCE↗

Recommendations for harmonized reporting of radiation Dosimetry by adoption of Compatibility in Irradiation Research Protocols Expert Roundtable (CIRPER)

Here, in radiobiology, radiation physics, and related areas, there is growing interest in transitioning from cesium-based irradiators to X-ray technologies. Therefore, it makes it imperative for reproducibility purposes, for researchers to provide specifications regarding device parameters, machine calibration details, and experimental setup when innovative X-ray technology is being employed. Several groups have already identified a glaring lack in completeness of critical information on experimental setups, equipment, and physical parameters in published radiation biology studies. The Alternative Technologies Meta Study Report by Brookhaven National Laboratory (BNL) examined 456 manuscripts published between 2017-2021. Only 64 of the reviewed studies (14.0%) consistently reported methods that could allow for replication of their studies. However, 85% provided information on the manufacturer, the irradiator model and the absorbed radiation dose. Approximately 66% provided information on the energy spectra and the dose rate, but only one third disclosed the filter used. Less than 15% of the reviewed studies reported information on calibration and field geometry, specifically field size and distance from source, which are critical parameters in determining the absorbed radiation dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Future trends in synchrotron science at NSLS-II

In this paper, we summarize briefly some of the future trends in synchrotron science as seen at the National Synchrotron Light Source II, a new, low emittance source recently commissioned at Brookhaven National Laboratory. We touch upon imaging techniques, the study of dynamics, the increasing use of multimodal approaches, the vital importance of data science, and finally, other enabling technologies. Each are presently undergoing a time of rapid change, driving the field of synchrotron science forward at an ever increasing pace. It is truly an exciting time and one in which Roger Cowley, to whom this journal issue is dedicated, would surely be both invigorated by, and at the heart of.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurements of an AC-LGAD strip sensor with a 120 GeV proton beam

The development of detectors that provide high resolution in four dimensions has attracted wide-spread interest in the scientific community for several applications in high-energy physics, nuclear physics, medical imaging, mass spectroscopy as well as quantum information. In addition to high time resolution and thanks to the AC-coupling of the electrodes, LGAD silicon sensors can provide high resolution in the measurement of spatial coordinates of an incident minimum ionizing particle. Such AC-coupled LGADs, also known as AC-LGADs, are therefore considered as candidates for future detectors to provide 4-dimensional measurements in a single sensing device with 100% fill factor. This article presents the first characterization of an AC-LGAD sensor with a proton beam of 120 GeV momentum at Fermilab. The sensor consists of strips with 80 μm width, fabricated at Brookhaven National Laboratory. The signal properties, efficiency, spatial, and time resolution are presented. Overall, the experimental results show that the time resolution of such an AC-LGAD is compatible to standard LGADs with similar gain, and that AC-LGADs can be segmented with fine pitches as standard strip or pixel detectors.

47 OTHER INSTRUMENTATION↗

Evaluation of radiation hardness of High-Voltage silicon vertical JFETs

In the future ATLAS Inner Tracker, each silicon strip module will be equipped with a switch able to separate the high voltage supply from the sensor in case the latter becomes faulty. The switch, placed in between the HV supply and the sensor, needs to sustain a high voltage in its OFF state, to offer a low resistance path for the sensor leakage current in the ON state, and be radiation hard up to 1.2 * 10 15 neq/cm 2 along with other requirements. While GaN JFETs have been selected as suitable rad-hard switch, a silicon vertical HV-JFET was developed by Brookhaven National Laboratory as an alternative option. Pre-irradiation results showed the functionality of the device and proved that the silicon HV-JFET satisfied the pre-irradiation requirements for the switch. To assess its suitability after irradiation, a few p-type HV-JFETs have been neutron irradiated at Jozef Stefan Institute (JSI, Ljubljana, Slovenia). Overall, this paper reports the static characterization of these irradiated devices and the TCAD numerical simulations used to get an insight of the physics governing the post-irradiation behaviour.

47 OTHER INSTRUMENTATION↗

Quality assurance test of silicon photomultipliers and electronic boards for STAR event plane detector

The event plane detector (EPD), installed in the Solenoid Tracker at the Relativistic Heavy-Ion Collider located at the Brookhaven National Laboratory is a plastic scintillator-based device that measures the reaction centrality and event plane in the forward region of the relativistic heavy-ion collisions. We used silicon photomultiplier (SiPM) arrays to detect the photons produced in the scintillator via the fiber connection. Signals from the SiPM arrays were amplified by the front-end electronic (FEE) board, and sent to the analog-to-digital converter (ADC) boards for further processing via the receiver (RX) board. The full EPD system consisted of 24 super-sectors (SSs); each SS was equipped with two SiPM boards, two FEE boards and two RX boards, and they corresponded to 744 readout channels. All these boards were mass produced at the University of Science and Technology of China, with a dedicated quality assurance (QA) procedures applied to identify any problems before deployment. This article describes the details of the QA method and the related test system. As a result, the QA test results are presented along with the discussions.

EPD↗

Design of high-performance guns for the HL-LHC HEL

The High Luminosity LHC project (HL-LHC) foresees the construction and installation of important new equipment to increase the performance of the LHC machine. The Hollow Electron Lens (HEL) is a promising system to control the beam halo. It improves the beam collimation system of the HL-LHC and mitigates possible equipment damage in case of failure scenarios from halo losses. The halo can store up to 30 MJ energy. The specifications for this new device are quite demanding. The source, an electron gun with an annular shaped cathode, must deliver a current up to 5 A. Additionally, this is five times higher than the current in the existing electron lenses in Fermi and Brookhaven national laboratories. This note describes the programme carried out to design and test high-perveance guns equipped with two types of high-performance scandate cathodes. The size of the final gun for the HL-LHC lenses is now considerably smaller than the one of the first prototype, allowing a reduction of diameter and cost of the superconducting magnet system used to steer the electron beam. The tests carried out at FNAL, BVERI and BJUT demonstrated that the developed cathodes fulfil the specifications and can supply a 5 A fully Space Charge Limited (SCL) current.

43 PARTICLE ACCELERATORS↗

Measurements of time and spatial resolution of AC-LGADs with different designs

AC-LGAD sensors are prime candidates for fast and precise measurement of charged particles in a variety of applications. In a fine-pitched pixel or strip AC-LGAD sensor, the signal generated by the passage of a particle is not localized in a limited volume in the sensor, but is shared among multiple electrodes. This signal sharing characteristic allows us to improve the spatial resolution of AC-LGAD sensors beyond the capabilities of common silicon trackers. Since the magnitude of the shared signal depends on the distance between the pixels or strips and the point of passage of the particle, signal sharing is strongly influenced by the geometry of the sensor. The electrode pitch and gap size as well as the shape can be fine tuned to maximize the space resolution, while keeping the detector granularity and the number of channels to be read out under control. Prototypes of AC-LGAD sensors produced at the Brookhaven National Laboratory covering a variety of possible geometries have been studied via Transient Current Technique using an infrared laser, and the signal sharing, spatial resolution, and time resolution of the different topologies have been measured. These results have been compared with measurements performed in test-beams with 120 GeV protons at the Fermilab Test Beam Facility. A time resolution of ~30 ps can be achieved using AC-LGAD sensors with a thickness of 50 μm, compatible to that of standard DC-coupled LGADs, while presenting a far superior spatial resolution. Finally, this combination of high precision, fast timing capabilities, and low material budget makes AC-LGADs an ideal choice for a truly 4D detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electrical performances of pre-production staves for the ATLAS ITk Strip Detector Upgrade

The ATLAS experiment is currently preparing for an upgrade of the inner tracking detector for the High-Luminosity LHC. The new tracker, ITk, employs an all-silicon detector with outer strip layers. The building block of the ITk strip barrel is the stave which consists of a low-mass support structure hosting the common electrical, optical and cooling services as well as 28 silicon modules. In this contribution, we outline the challenging aspects of the stave pre-production testing phase at Brookhaven National Laboratory. Here, the electrical characterization of these staves, hosting the final design of all ASICs, will be discussed in detail.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a large array of Silicon Drift Detectors for high-rate synchrotron fluorescence spectroscopy

An array of small-area Silicon Drift Detectors (SDD), named Hera, has been developed at Brookhaven National Laboratory (BNL) in the past few years. Its primary application is high-rate spectroscopy at synchrotrons. Each SDD pixel is a 1 mm × 1 mm square to match the footprint of the original diode-based pixel detector called Maia, which was developed for the same application. The replacement of the diode with an SDD allows for better energy resolution at short shaping times and an increased stability of the detector. 32, 96, and 384-channel arrays were designed and fabricated and achieved a Full Width Half Maximum (FWHM) as low as 176 eV at 5.9 keV with peaking time of 1 μs at -13°C. The sensor design, simulation, fabrication, its readout system, and its spectroscopic performance are reported.

47 OTHER INSTRUMENTATION↗

First survey of centimeter-scale AC-LGAD strip sensors with a 120 GeV proton beam

We present the first beam test results with centimeter-scale AC-LGAD strip sensors, using the Fermilab Test Beam Facility and sensors manufactured by the Brookhaven National Laboratory. Sensors of this type are envisioned for applications that require large-area precision 4D tracking coverage with economical channel counts, including timing layers for the Electron Ion Collider (EIC), and space-based particle experiments. A survey of sensor designs is presented, with the aim of optimizing the electrode geometry for spatial resolution and timing performance. Several design considerations are discussed towards maintaining desirable signal characteristics with increasingly larger electrodes. The resolutions obtained with several prototypes are presented, reaching simultaneous 18 μm and 32 ps resolutions from strips of 1 cm length and 500 μm pitch. With only slight modifications, these sensors would be ideal candidates for a 4D timing layer at the EIC.

47 OTHER INSTRUMENTATION↗

The potential of a TeV-scale muon-ion collider

We propose the development of a novel muon-proton and muon-nucleus collider facility at the TeV scale that is capable of performing precision deep inelastic scattering measurements in new regimes and providing a rich program in nuclear and particle physics. Such a facility could seed, or leverage, the development of a muon-antimuon collider and make use of the existing hadron accelerator infrastructure when sited at a facility such as Brookhaven National Laboratory, Fermilab, or CERN. Here, we discuss the possible energy and luminosity design parameters for several collider configurations, and illustrate the science potential with several studies on deep inelastic scattering kinematics, Higgs and vector boson production, top quark production, and beyond Standard Model leptoquark production. Detector design considerations and a possible road map toward development are also given.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗