Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BUNDLE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Cartesian grid simulations of bubbling fluidized beds with a horizontal tube bundle

In this paper, the flow hydrodynamics in a bubbling fluidized bed with submerged horizontal tube bundle was numerically investigated with an open-source code: Multiphase Flow with Interphase eXchange (MFIX). A newly implemented cut-cell technique was employed to deal with the curved surface of submerged tubes. A series of 2D simulations were conducted to study the effects of gas velocity and tube arrangement on the flow pattern. Hydrodynamic heterogeneities on voidage, particle velocity, bubble fraction, and frequency near the tube circumferential surface were successfully predicted by this numerical method, which agrees qualitatively with previous experimental findings and contributes to a sounder understanding of the non-uniform heat transfer and erosion around a horizontal tube. A 3D simulation was also conducted. Significant differences between 2D and 3D simulations were observed with respect to bed expansion, bubble distribution, voidage, and solids velocity profiles. Hence, the 3D simulation is needed for quantitative prediction of flow hydrodynamics. On the other hand, the flow characteristics and bubble behavior at the tube surface are similar under both 2D and 3D simulations as far as the bubble frequency and bubble phase fraction are concerned. Comparison with experimental data showed that qualitative agreement was obtained in both 2D and 3D simulations for the bubble characteristics at the tube surface.

42 ENGINEERING↗

On the capillary pressure function in porous media based on relative permeabilities of two immiscible fluids: Application of capillary bundle models and validation using experimental data

The objective of this paper is to extend the theoretical approach and an analytical solution, which was proposed by Babchin and Faybishenko (2014), for the evaluation of a capillary pressure (P c ) curve in porous media based on the apparent specific surface area, using an explicit combination of the relative permeability functions for the wetting and nonwetting phases. Specifically, in the current paper, the authors extended this approach by the application of two types of capillary bundle models with different formulations of effective capillary radius formulae. The application of the new models allowed the authors to improve the results of calculations of the effective average contact angle given in the paper by Babchin and Faybishenko (2014). The validation of the new models for calculations of the P c curve is also given in this paper using the results of a specifically designed core experiment, which was originally conducted by Ayub and Bentsen (2001).

58 GEOSCIENCES↗

Annular flow in rod-bundle: Effect of spacer on disturbance waves

A high-speed camera technique is used to study the effect of spacers on the disturbance waves present in annular two-phase flow within a rod-bundle geometry. Images obtained using a backlight configuration to visualize the spacer-wave interactions at the micro-scale resolution (in time and space) are discussed. This paper also presents additional images obtained using a reflected light configuration which provides new observations of the disturbance waves. These images show the separation effect caused by the spacer on the liquid film in which the size of generated liquid droplets can be controlled by the gas superficial velocity. Furthermore, the data confirm that the spacer breaks the circumferential coherent structures of the waves.

disturbance waves↗

On falling film evaporator – A review of mechanisms and critical assessment of correlation on a horizontal tube bundle with updated development

Optimization of the energy efficiency and reduction of the greenhouse gas emission for the heat pump system is imperative to meet the net-zero goals at 2050. Chillers with falling film evaporator design not only possess better system performance but also contain less refrigerant inventory. Hence, accurate prediction of the evaporator performance is pivotal especially when charged with low-GWP refrigerant. Here, the study reviews the correlations for falling film evaporator with a horizontal tube bundle configuration. The major efforts of this study include four tasks: (a) literature review of the experimental studies and available empirical correlations; (b) comprehensive discussion of the falling film evaporation heat transfer mechanism; (c) development of a new rationally based correlation based on available literature; and (d) comparison of different correlations based on the existing data. The collected data includes 4114 data points from 8 sources, 6 refrigerants (R-600a, R-290, R-245fa, R-134a, R-1234ze(E), R-123), 5 types of the tubes (Plain, Turbo-GII-HP, GEWA-B, Low-fin, High-Flux), liquid Weber number from 2.2 × 10 –6 to 0.7, imposed vapor Weber number from 0 to 37.2, heat flux from 2.5 to 151.5 kW/m 2 , and film Reynolds number from 1 to 3159.8. The new correlation gives a MAD of 28.3%, and an R 2 of 0.86. Yet, the developed correlation considers various heat transfer mechanisms, including the transition point from falling film evaporation to the nucleate boiling, local evaporation, dry-out, mist flow, imposed flow, and enhanced tube effects.

42 ENGINEERING↗

On the use of LES-based turbulent thermal-stress models for rod bundle simulations

An alternative methodology is proposed here to overcome the excessive cost of large eddy simulations (LES) of full-length heated rod bundle calculations, while improving the inaccurate results typically obtained with Reynolds-averaged Navier-Stokes equations (RANS). While the cost of the full-length LES is generally too high, LES of a small section of a single rod is usually affordable. The idea presented here consists of using the information granted by the small LES calculation to determine the appropriate turbulence viscosity or turbulent thermal diffusivity that can be used to solve only for the temperature field in a pseudo-RANS approach. The study has been performed with single-rod simulations with a P/D of 1.12 and 1.24, considering rod lengths that are representative of reactor applications, for the cases of uniform heat flux and a more realistic cosine-like axial heat distribution. Here, the spectral element code Nek5000 has been used for all LES, RANS, and pseudo-RANS simulations. The recently proposed Nek5000 steady-state solver has been used for solving the temperature field in the pseudo-RANS approach and has proved significantly faster than transient schemes. Prediction of thermal quantities is compared with classical linear and nonlinear RANS models. LES for the full-length rods has also been performed and is used as a reference. Results of the proposed method show significant improvements with respect to those obtained with RANS.

42 ENGINEERING↗

Comparison of experimental and simulation results on interior subchannels of a 61-pin wire-wrapped hexagonal fuel bundle

As part of a joint U.S. Department of Energy project, Framatome, Argonne National Laboratory, Terrapower, and Texas A&M University have collaborated to produce experimental data and computational results to characterize the flow behavior of a 61-pin wire-wrapped hexagonal fuel bundle. Here, comparisons are made between Texas A&M’s experimental particle image velocimetry velocity field measurements and Argonne National Laboratory’s large-eddy simulation results in an interior subchannel for a Reynolds number of 19,000. It can be concluded that the shape and magnitude of the mean vertical velocity component is in excellent agreement for the selected horizontal line plots. Maximum relative errors are less than 10% until the subchannel walls are approached. Finally, the shape and, to a lesser extent, magnitude of the mean horizontal velocity component is in satisfactory agreement between the particle image velocimetry and large-eddy simulation results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Three-Dimensional Magnetic Reconnection With a Spatially Confined X-Line Extent: Implications for Dipolarizing Flux Bundles and the Dawn-Dusk Asymmetry

Using 3-D particle-in-cell simulations, we study magnetic reconnection with the X-line being spatially confined in the current direction.We include thick current layers to prevent reconnection at two ends of a thin current sheet that has a thickness on an ion inertial ($d_i$) scale. The reconnection rate and outflow speed drop significantly when the extent of the thin current sheet in the current direction is $≲ O$(10$d_i$). When the thin current sheet extent is long enough, we find that it consists of two distinct regions; a suppressed reconnecting region (on the ion-drifting side) exists adjacent to the active region where reconnection proceeds normally as in a 2-D case with a typical fast rate value ≃ 0.1. The extent of this suppression region is $≃ O$(10$d_i$), and it suppresses reconnection when the thin current sheet extent is comparable or shorter. The time scale of current sheet thinning toward fast reconnection can be translated into the spatial scale of this suppression region, because electron drifts inside the ion diffusion region transport the reconnected magnetic flux, which drives outflows and furthers the current sheet thinning, away from this region. This is a consequence of the Hall effect in 3-D. While the existence of this suppression region may explain the shortest possible azimuthal extent of dipolarizing flux bundles at Earth, it may also explain the dawn-dusk asymmetry observed at the magnetotail of Mercury, which has a global dawn-dusk extent much shorter than that of Earth.

79 ASTRONOMY AND ASTROPHYSICS↗

Pressure Drop in Seven-Pin Wire-Wrapped Rod Bundle for the Sodium Cartridge Loop in Versatile Test Reactor

This work studies the hydrodynamics of the seven pin wire-wrapped rod bundle in the sodium cartridge loop for the Versatile Test Reactor (VTR) through scaled water experiments and computational fluid dynamics (CFD) simulations. Here, the scaling analysis is first performed to demonstrate the hydrodynamic similarity between water and sodium flows at the same Reynolds number Re. A separate-effects test facility is designed and constructed based on the scaling analysis. Detailed experimental data on the pressure drop covering a wide range of Re values (1165 to 27 689) are obtained, which are used to evaluate existing correlations for friction factor and to benchmark CFD simulations. The experimentally determined friction factors f Exp agree well with the Upgraded Cheng and Todreas Detailed Correlation and Pacio-Chen-Todreas Detailed Model within ±7% but are significantly underpredicted by Rehme's correlation by 25%. Various CFD near-wall treatment methods are tested using ANSYS Fluent and evaluated by experimental data. It is found that when the recommended wall y + values are met, most of the near-wall treatment methods can give accurate friction factor predictions. The resolved near-wall method (y + ~ 1) with the Shear Stress Transport k - ω turbulence model and the scalable wall functions (y + > 12) with the realizable k - ε turbulence model can predict f Exp within ±5% The standard wall functions (y + > 30) and nonequilibrium wall functions (y + > 30) with the realizable k - ε model can predict f Exp within ±10%.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hydra-TH Simulation of Single-Phase Flow and Heat Transfer in a Rod Bundle Segment

The focus of this report is on the comparison of numerical prediction by Hydra-TH of single phase flow and heat transfer in a segment of Light Water Reactor (LWR) rod bundle geometries with experimental results of Krauss and Meyer. This effort is to support the development of Hydra-TH code, which is a centerpiece of the CASL advanced CFD capability.

97 MATHEMATICS AND COMPUTING↗

Alpha1 LASSO data bundles Lamont, OK

A data bundle is a unified package consisting of LASSO LES input and output, observations, evaluation diagnostics, and model skill scores. LES input includes model configuration information and forcing data. LES output includes profile statistics and full domain fields of cloud and environmental variables. Model evaluation data consists of LES output and ARM observations co-registered on the same grid and sampling frequency. Model performance is quantified by skill scores and diagnostics in terms of cloud and environmental variables.

54 ENVIRONMENTAL SCIENCES↗

Heat Emission and Temperature Non-uniformity in Rod Bundles with Different Spacing, Cooled by Heavy Liquid-Metal Coolant

Heat emission and temperature non-uniformity along the perimeter of rods in free lattices of fuel elements with heavy liquid-metal coolant are studied. The experimental data for an assembly of smooth rods, assemblies of fuel elements with spiral ribbing, and transverse lattices are analyzed. The studies show that there is almost no temperature non-uniformity in a lattice of smooth fuel elements along its perimeter, which is in contrast to the high general azimuthal temperature non-uniformity in an assembly with spacing by spiral coils. Rib spacing resulted in significant reduction of heat emission. In an assembly with transverse spacer lattices, the heat emission increases only in the region containing the lattices; in the spaces between lattices, it is approximately equal to the heat emission in a bundle with smooth fuel elements. Inside a spacer lattice, periodic temperature non-uniformities appear along the perimeter of the fuel elements; these non-uniformities are due to the fuel elements touching the elements of the lattice. A relation is recommended for calculating heat emission (Nusselt numbers) and temperature non-uniformity along the perimeter of the fuel elements for the studied methods of spacing the fuel elements.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

New Examples of Integrable Systems with Dissipation on the Tangent Bundles of Multidimensional Spheres

In many problems of multidimensional dynamics, systems appear whose state spaces are spheres of finite dimension. Clearly, phase spaces of such systems are tangent bundles of these spheres. In this paper, we examine nonconservative force fields in the dynamics of a multidimensional rigid body in which the system possesses a complete set of first integrals that can be expressed as finite combinations of elementary transcendental functions. We consider the case where the moment of nonconservative forces depends on the tensor of angular velocity.

97 MATHEMATICS AND COMPUTING↗

Relationships between electrical and mechanical dyssynchrony in patients with left bundle branch block and healthy controls

Background: Abnormal electrical activation may cause dyssynchronous left ventricular (LV) contraction. In this study, we characterized and analyzed electrical and mechanical dyssynchrony in patient with left bundle branch block (LBBB) and healthy controls. Methods: Myocardial perfusion imaging (MPI) data from 994 patients were analyzed. Forty-three patient fulfilled criteria for LBBB and 24 for controls. Electrical activation was characterized with vector electrocardiography (VECG) and LV function including mechanical dyssynchrony with ECG-gated MPI phase analysis. Results: QRS duration (QRSd; r = 0.69, P < .001) and a few other VECG parameters correlated significantly with phase bandwidth (phaseBW) representing mechanical dyssynchrony. End-diastolic volume (EDV; r = 0.59, P < .001), ejection fraction and end-systolic volume correlated also with phaseBW. QRSd (β = 0.47, P < .001) and EDV (β = 0.36, P = .001) were independently associated with phaseBW explaining 55% of its variation. Sixty percent of patients with LBBB had significant mechanical dyssynchrony. Those patients had wider QRSd (159 vs 147 ms, P = .013) and larger EDV (144 vs 94 mL, P = .008) than those with synchronous LV contraction. Cut-off values for mechanical dyssynchrony seen in patients with LBBB were QRSd ≥ 165 ms and EDV ≥ 109 mL. Conclusions: Despite obvious conduction abnormality, LBBB is not always accompanied by mechanical dyssynchrony. QRSd and EDV explained 55% of variation seen in phaseBW. These two parameters were statistically different between LBBB cases with and without mechanical dyssynchrony.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Complex equations of motion for a body under gravitational influence by using a nine-parameter space–time bundle with the structural group SO(3,C)

We give equations of motion of a body under gravitational influence using a model which employs nonlinear connection adapted to 3+3+3-dimensional bundle. It is analogous to the corresponding 3+1 model with nonlinear connection in Minkowski spacetime. The equations of motion are simple complex equations whose real part gives the equations of motion previously obtained in the 3+1 model with nonlinear connection in Minkowski spacetime. They lead to the same predictions as the General Relativity, which are experimentally verified. The imaginary part of the equations of motion gives the total precession of a gyroscope (geodetic precession and frame dragging). The complex equations of motion can be used also in electrodynamics. In this case, the imaginary part corresponds to the Lorentz force, while the real part leads to the angular velocity of an electron in a magnetic field. It is obtained Ω-vector =(e/(mc)) H-vector (if E-vector =0), which fits well with the observations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Crystal structure of the GTPase domain and the bundle signalling element of dynamin in the GDP state

Dynamin is the prototype of a family of large multi-domain GTPases. The 100 kDa protein is a key player in clathrin-mediated endocytosis, where it cleaves off vesicles from membranes using the energy from GTP hydrolysis. We have solved the high resolution crystal structure of a fusion protein of the GTPase domain and the bundle signalling element (BSE) of dynamin 1 liganded with GDP. The structure provides a hitherto missing snapshot of the GDP state of the hydrolytic cycle of dynamin and reveals how the switch I region moves away from the active site after GTP hydrolysis and release of inorganic phosphate. Comparing our structure of the GDP state with the known structures of the GTP state, the transition state and the nucleotide-free state of dynamin 1 we describe the structural changes through the hydrolytic cycle. - Highlights: • High resolution crystal structure of the GDP-state of a dynamin 1 GTPase-BSE fusion. • Visualizes one of the key states of the hydrolytic cycle of dynamin. • The dynamin-specific loop forms a helix as soon as a guanine base is present.

60 APPLIED LIFE SCIENCES↗

There Is No Correlation Between Erectile Dysfunction and Dose to Penile Bulb and Neurovascular Bundles Following Real-Time Low-Dose-Rate Prostate Brachytherapy

Purpose: We evaluated the relationship between the onset of erectile dysfunction and dose to the penile bulb and neurovascular bundles (NVBs) after real-time ultrasound-guided prostate brachytherapy. Methods and Materials: One hundred forty-seven patients who underwent prostate brachytherapy met the following eligibility criteria: (1) treatment with {sup 125}I brachytherapy to a prescribed dose of 160 Gy with or without hormones without supplemental external beam radiation therapy, (2) identification as potent before the time of implantation based on a score of 2 or higher on the physician-assigned Mount Sinai Erectile Function Score and a score of 16 or higher on the abbreviated International Index of Erectile Function patient assessment, and (3) minimum follow-up of 12 months. Median follow-up was 25.7 months (range, 12-47 months). Results: The 3-year actuarial rate of impotence was 23% (34 of 147 patients). An additional 43% of potent patients (49 of 113 patients) were using a potency aid at last follow-up. The penile bulb volume receiving 100% of the prescription dose (V{sub 100}) ranged from 0-0.05 cc (median, 0 cc), with a dose to the hottest 5% (D{sub 5}) range of 12.5-97.9 Gy (median, 40.8 Gy). There was no correlation between penile bulb D{sub 5} or V{sub 100} and postimplantation impotency on actuarial analysis. For the combined right and left NVB structures, V{sub 100} range was 0.3-5.1 cc (median, 1.8 cc), and V{sub 150} range was 0-1.5 cc (median, 0.31 cc). There was no association between NVB V{sub 100} or V{sub 150} and postimplantation impotency on actuarial analysis. Conclusion: Penile bulb doses are low after real-time ultrasound-guided prostate brachytherapy. We found no correlation between dose to either the penile bulb or NVBs and the development of postimplantation impotency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Neurovascular bundle–sparing radiotherapy for prostate cancer using MRI-CT registration: A dosimetric feasibility study

Purpose: Sexual dysfunction after radiotherapy for prostate cancer remains an important late adverse toxicity. The neurovascular bundles (NVB) that lie posterolaterally to the prostate are typically spared during prostatectomy, but in traditional radiotherapy planning they are not contoured as an organ-at-risk with dose constraints. Our goal was to determine the dosimetric feasibility of “NVB-sparing” prostate radiotherapy while still delivering adequate dose to the prostate. Methods: Twenty-five consecutive patients with prostate cancer (with no extraprostatic disease on pelvic magnetic resonance imaging [MRI]) who that were treated with external beam radiotherapy, with the same primary planning target volume margins, to a dose of 79.2 Gy were evaluated. Pelvic MRI and simulation computed tomography scans were registered using dedicated software to allow for bilateral NVB target delineation on T2-weighted MRI. A volumetric modulated arc therapy plan was generated using the NVB bilaterally with 2 mm margin as an organ to spare and compared to the patient’s previously delivered plan. Dose-volume histogram endpoints for NVB, rectum, bladder, and planning target volume 79.2 were compared between the 2 plans using a 2-tailed paired t-test. Results: The V70 for the NVB was significantly lower on the NVB-sparing plan (p <0.01), while rectum and bladder endpoints were similar. Target V100% was similar but V{sub 105%} was higher for the NVB-sparing plans (p <0.01). Conclusions: “NVB-sparing” radiotherapy is dosimetrically feasible using CT-MRI registration, and for volumetric modulated arc therapy technology — target coverage is acceptable without increased dose to other normal structures, but with higher target dose inhomogeneity. The clinical impact of “NVB-sparing” radiotherapy is currently under study at our institution.

61 RADIATION PROTECTION AND DOSIMETRY↗

One-way coupled simulation of FIV in a 7-pin wire-wrapped fuel pin bundle

A normal fuel geometry found in sodium cooled reactor designs is the hexagonal lattice of wire-wrapped fuel pins. The wire-wrappers, which replace the more common spacer grids, act as a spacer between the fuel pins, while simultaneously increasing the fluid mixing between subchannels. The induced transverse flow, while good for mixing, increases the force load experienced by the fuel pins, increasing the possibility of problematic flow induced vibrations. The primary source of vibrations is turbulent buffeting, so very small in amplitude, but capable of rupturing the fuel cladding by fretting. The vast majority of research on fretting has been for bare rods with spacer grids. There are several significant ways that wire-wrapped fuel pins differ from bare rods that may have significant impact on the vibrations present. The increased transverse flow and asymmetrical flow pattern may result in larger and imbalanced force loads on the pins. The helical bracing of each pin may result in unique vibration patterns, and gaps may form between pins affecting how they are braced. Simulation allows for the observation of the forces present, how the flow field affects these forces, and how the structure responds and can be repeated for multiple cases for relatively low cost. Here, simulation of the flow induced vibrations for a 7-pin wire-wrapped fuel pin bundle is carried out by coupling Nek5000, a spectral element LES/DNS solver with DIABLO, a finite element CSM solver. The small amplitude vibrations allow for the assumption that the structure motion has negligible effect on the fluid flow, permitting the much less computationally expensive one-direction coupling. In order to gather significant force history data for the 2.63 helical pitch structure, a scheme was developed to artificially create force history from the power spectrum density of the one-pitch CFD simulation forces. The vibrations could then be simulated in the structure multiple times varying the contact and gaps between various pins. This provides for the search of worst-case scenarios and informs about the types of fretting that might be present. The simulation geometry is based on an experiment for comparison. However, the viscosity of the simulation was increased by a factor of four to make the simulation computationally feasible. While validation is not possible, comparisons are still valuable.

42 ENGINEERING↗