Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BOILING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Validation of the SCALE/Polaris–PARCS Code Procedure With the ENDF/B-VII.1 AMPX 56-Group Library: Boiling Water Reactor

The SCALE/Polaris–PARCS code procedure has been used in the confirmatory analysis for boiling water reactors by the US Nuclear Regulatory Commission. In this study, the SCALE/Polaris v6.3.0–PARCS v3.4.2 code procedure with the Evaluated Nuclear Data File (ENDF)/B-VII.1 AMPX 56-group library was validated by comparing the simulated results with the measured data for operating boiling water reactors, including Peach Bottom Unit 2 cycles 1–3, Hatch Unit 1 cycles 1–3, and Quad Cities Unit 1 cycles 1–3. The uncertainties and biases of the SCALE/Polaris–PARCS code package for boiling water reactor physics analysis were evaluated in the validation for key nuclear parameters such as reactivity and traversing in-core probe data.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental, Computational, Theoretical and Analytical Investigation of Flow Boiling in Reduced Gravity

Two-phase thermal management systems are far superior to their single-phase counterparts because of their ability to capitalize on the coolant’s both sensible and latent heats, thereby yielding orders of magnitude higher heat transfer coefficients and smaller system footprints. A vital knowledge necessary for their implementation in future space systems is performance in microgravity. Long-duration microgravity experiments are necessary to obtain reliable databases, which would then be used to build reliable predictive tools. To achieve this goal, investigators at the Purdue University Boiling and Two-Phase Flow Laboratory (PU-BTPFL) and the NASA Glenn Research Center (NASA-GRC) have been collaborating towards the development of the Flow Boiling and Condensation Experiment (FBCE) and eventual execution onboard the International Space Station (ISS). FBCE has now matured to a point where it is ready for transport to the ISS, where first tests will be conducted using the Flow Boiling Module (FBM). In preparation for the ISS tests, a series of pre-launch Mission Sequence Tests (MSTs) was performed at GRC in Earth gravity with FBM mounted in a vertical upflow orientation using n-perfluorohexane as working fluid. The pre-launch tests included variations of flow rate, surface heat flux, inlet conditions, and both single-sided and double-sided wall heating. This presentation will summarize experimental results from these tests as well as both analytic and theoretical tools for prediction of two-phase heat transfer coefficient and critical heat flux (CHF). Also discussed will be an assessment of predictive accuracy of these tools against the experimental data.

Mission Sequence tests↗

Modeling and Simulation of Tank Pressure Control using Zero-Boil Off Active Thermal Control for LOXSAT Technology Demonstration Mission

To-date, research and modeling of cryogenic fluid management technologies (CFM) for spaceflight has been limited to ground tests, short-duration zero-g simulations (e.g. drop towers), and small-scale experiments on-orbit. There has not been a large-scale flight demonstration of a flight-like system. As future NASA missions to take humans further from Earth will require large, in-space cryogenic propulsion vehicles, it is imperative to begin collecting flight data for these systems to accurately model and design future vehicles. To meet this goal, NASA awarded tipping point technology demonstration awards to Eta Space, Lockheed Martin, Space Exploration Technologies (SpaceX), and United Launch Alliance (ULA) to demonstrate on-orbit storage and transfer of cryogenic propellant. For its award, Eta Space is developing LOXSAT-1. It is a small satellite that will be launched on a Rocket Lab Electron rocket. The spacecraft consists of a Rocket Lab Photon spacecraft bus with a primary payload of a spherical liquid oxygen (LOX) storage tank with thermodynamic control systems. The primary objective of the mission is to demonstrate zero-boil-off storage of liquid oxygen. To accomplish this objective, the payload is equipped with an active thermal control system fluid loop that consists of propellant management device (PMD), positive-displacement pump, heat exchanger connected to a cryocooler, and a spray bar mixing injector. When the fluid loop is operating, fluid is drawn from the tank by the PMD and pumped through the heat exchanger, lowering the fluid temperature below the fluid temperature in the tank. This subcooled liquid is then injected back into the tank through the spray bar. The subcooled injected liquid has two effects. If it is sprayed into the ullage space, the injected liquid will form into jets or droplets and exchange heat with the ullage gas. This will cool and condense the gas, reducing the pressure in the tank. Additionally, the liquid that is not sprayed through the ullage, as well as any remaining liquid spray from the ullage, will rejoin the liquid mass of the tank, lowering the bulk temperature of the liquid. These combines effects provide for zero-boil off pressure control by lowering the tank pressure and the liquid saturation pressure simultaneously, ensuring the liquid stays subcooled. To model these complex mechanics and predict the performance of the active thermal control system, NASA is providing Eta Space with 3 parallel models of the tank. The approach of providing 3 different models allows for cross-checking and comparisons between the three to better understand how different modeling assumptions and selection semi-empirical factors affects the modeling result. Additionally, developing 3 models provides three different schemes for numerical simulation, providing confidence that results depict real physical phenomenon and not numerical quirks of the program. Within the tank thermodynamics, there are two primary areas of heat transfer we concern ourselves with: the heat transfer between the ullage space and the droplet spray, and between the ullage space and bulk liquid. For the droplet heat transfer, there are multiple sets of assumptions that can be made and correlations that can be used. Currently, two working models - the TankSIM model and Easy5 model – provide for an overview of the different approaches available. The TankSIM model and Easy5 model use two different models for droplet heating and evaporation that illustrate how the models use different types of mechanisms to arrive at the same answer. For the TankSIM model, droplets are treated as spheres of constant radius. Heat is transferred from the ullage to the droplet and warms the droplet until it reaches saturation, then the droplet begins evaporating and reducing its radius and mass. To calculate the heat transfer coefficient between the droplet and ullage, the Ranz-Marshall correlation is used. To determine the number of droplets in the ullage, a resident mass approach is used. This approach averages the number of droplets such that residuals at the start-up and shut-off of the spray bar cancel out. This same approach is used in the Easy5 model. The GFSSP model implements a linked list to track individual droplet “nodes” within the model. For the Easy5 model, the droplet is assumed to have an interface at a temperature equal to the saturation temperature corresponding to the pressure of the gas phase. The heat transfer from the gas to the interface and the interface to the droplet bulk is then calculated, and the net mass transfer between the droplet and interface is determined by performing an energy balance across the interface. For the gas side of the interface, the Ranz-Marshall correlation is used. For the liquid side of the interface, a variety of correlations were tried, including Kronig and Brink (1950) and effective conductivity models. As a result of these assumptions, the Easy5 model currently predicts faster depressurization, as at saturated vapor conditions, the heat transfer coeffect on the liquid side for the Easy5 model is greater than the heat transfer coefficient predicted by Ranz-Marshall used in the TankSIM code. This greater heat flux translates into faster condensation of the saturated ullage gas. At the bulk liquid to ullage interface, the models are in much closer agreement. Both models model the ullage as a sphere centered within the bulk liquid in the tank, and both use the energy-jumping boundary condition to model heat and mass transfer across the interface. There are slight differences in how the interface temperature is calculated, however. The Easy5 model assumes the temperature of the interface is equal to the saturation temperature associated with the pressure of the gas phase. The TankSIM model calculates this temperature with Alabovskii’s equation, which provides a correction factor for interface temperatures. Analysis tasks are focused on determining rates of depressurization within the tank during active cooling operation. To maintain net positive suction head at the pump inlet, the tank pressure cannot fall faster than the saturation pressure associated with the temperature of the bulk liquid. Additionally, there is interest in analyzing the performance of the loop at different pump speeds and cryocooler input powers. Adjusting the flowrate affects both the performance of the heat exchanger between the cryocooler and pumped liquid, and the heat transfer between the droplet spray and the ullage. Ideally, a pump speed and cryocooler power can be selected that will allow the tank to operate in zero-boil-off mode with a very narrow range of storage pressure.

zero boil-off↗

Modeling and Simulation of Tank Pressure Control using Zero-Boil Off Active Thermal Control for LOXSAT Technology Demonstration Mission

To-date, research and modeling of cryogenic fluid management technologies (CFM) for spaceflight has been limited to ground tests, short-duration zero-g simulations (e.g. drop towers), and small-scale experiments on-orbit. There has not been a large-scale flight demonstration of a flight-like system. As future NASA missions to take humans further from Earth will require large, in-space cryogenic propulsion vehicles, it is imperative to begin collecting flight data for these systems to accurately model and design future vehicles. To meet this goal, NASA awarded tipping point technology demonstration awards to Eta Space, Lockheed Martin, Space Exploration Technologies (SpaceX), and United Launch Alliance (ULA) to demonstrate on-orbit storage and transfer of cryogenic propellant. For its award, Eta Space is developing LOXSAT-1. It is a small satellite that will be launched on a Rocket Lab Electron rocket. The spacecraft consists of a Rocket Lab Photon spacecraft bus with a primary payload of a spherical liquid oxygen (LOX) storage tank with thermodynamic control systems. The primary objective of the mission is to demonstrate zero-boil-off storage of liquid oxygen. To accomplish this objective, the payload is equipped with an active thermal control system fluid loop that consists of propellant management device (PMD), positive-displacement pump, heat exchanger connected to a cryocooler, and a spray bar mixing injector. When the fluid loop is operating, fluid is drawn from the tank by the PMD and pumped through the heat exchanger, lowering the fluid temperature below the fluid temperature in the tank. This subcooled liquid is then injected back into the tank through the spray bar. The subcooled injected liquid has two effects. If it is sprayed into the ullage space, the injected liquid will form into jets or droplets and exchange heat with the ullage gas. This will cool and condense the gas, reducing the pressure in the tank. Additionally, the liquid that is not sprayed through the ullage, as well as any remaining liquid spray from the ullage, will rejoin the liquid mass of the tank, lowering the bulk temperature of the liquid. These combines effects provide for zero-boil off pressure control by lowering the tank pressure and the liquid saturation pressure simultaneously, ensuring the liquid stays subcooled. To model these complex mechanics and predict the performance of the active thermal control system, NASA is providing Eta Space with 3 parallel models of the tank. The approach of providing 3 different models allows for cross-checking and comparisons between the three to better understand how different modeling assumptions and selection semi-empirical factors affects the modeling result. Additionally, developing 3 models provides three different schemes for numerical simulation, providing confidence that results depict real physical phenomenon and not numerical quirks of the program. Within the tank thermodynamics, there are two primary areas of heat transfer we concern ourselves with: the heat transfer between the ullage space and the droplet spray, and between the ullage space and bulk liquid. For the droplet heat transfer, there are multiple sets of assumptions that can be made and correlations that can be used. Currently, two working models - the TankSIM model and Easy5 model – provide for an overview of the different approaches available. The TankSIM model and Easy5 model use two different models for droplet heating and evaporation that illustrate how the models use different types of mechanisms to arrive at the same answer. For the TankSIM model, droplets are treated as spheres of constant radius. Heat is transferred from the ullage to the droplet and warms the droplet until it reaches saturation, then the droplet begins evaporating and reducing its radius and mass. To calculate the heat transfer coefficient between the droplet and ullage, the Ranz-Marshall correlation is used. To determine the number of droplets in the ullage, a resident mass approach is used. This approach averages the number of droplets such that residuals at the start-up and shut-off of the spray bar cancel out. This same approach is used in the Easy5 model. The GFSSP model implements a linked list to track individual droplet “nodes” within the model. For the Easy5 model, the droplet is assumed to have an interface at a temperature equal to the saturation temperature corresponding to the pressure of the gas phase. The heat transfer from the gas to the interface and the interface to the droplet bulk is then calculated, and the net mass transfer between the droplet and interface is determined by performing an energy balance across the interface. For the gas side of the interface, the Ranz-Marshall correlation is used. For the liquid side of the interface, a variety of correlations were tried, including Kronig and Brink (1950) and effective conductivity models. As a result of these assumptions, the Easy5 model currently predicts faster depressurization, as at saturated vapor conditions, the heat transfer coeffect on the liquid side for the Easy5 model is greater than the heat transfer coefficient predicted by Ranz-Marshall used in the TankSIM code. This greater heat flux translates into faster condensation of the saturated ullage gas. At the bulk liquid to ullage interface, the models are in much closer agreement. Both models model the ullage as a sphere centered within the bulk liquid in the tank, and both use the energy-jumping boundary condition to model heat and mass transfer across the interface. There are slight differences in how the interface temperature is calculated, however. The Easy5 model assumes the temperature of the interface is equal to the saturation temperature associated with the pressure of the gas phase. The TankSIM model calculates this temperature with Alabovskii’s equation, which provides a correction factor for interface temperatures. Analysis tasks are focused on determining rates of depressurization within the tank during active cooling operation. To maintain net positive suction head at the pump inlet, the tank pressure cannot fall faster than the saturation pressure associated with the temperature of the bulk liquid. Additionally, there is interest in analyzing the performance of the loop at different pump speeds and cryocooler input powers. Adjusting the flowrate affects both the performance of the heat exchanger between the cryocooler and pumped liquid, and the heat transfer between the droplet spray and the ullage. Ideally, a pump speed and cryocooler power can be selected that will allow the tank to operate in zero-boil-off mode with a very narrow range of storage pressure.

zero boil-off↗

Control System Development for A Zero Boil-Off Hydrogen Storage Demonstration With Two-Stage Active Cooling

A NASA team is designing and building a test article to demonstrate the long duration storage of liquid hydrogen via active cooling (cryocoolers) while implementing a two-stage cooling approach. This activity is one of a large portfolio of NASA’s Space Technology Mission Directorate funded activities which focuses on the technology maturation needed for long duration storage of cryogenic liquid in-space. The current state-of-the-art for liquid hydrogen storage on-orbit is on the order of hours while NASA’s planned missions require storage for months, or even years. To enable such a long duration, Zero Boil-Off conditions must be achieved which requires passive technologies to minimize environmental heat loads, but also active cooling to intercept and reject the remaining heat to deep space. The implementation of active cooling results in a significant amount of dry mass added to the vehicle. Utilizing a Two-Stage Cooling approach, analysis and testing to date indicates the Zero Boil-Off of liquid hydrogen can be achieved with less mass and electrical power relative to a single-stage cooling approach where only one cryocooler is used. This activity will demonstrate the fully integrated suite of technologies needed to enable the Two-Stage Cooling approach which includes Multi-Layer Insulation blankets, Low Conductivity Structures, a Tube-On-Tank Heat Exchanger, Tube-On-Shield Heat Exchanger and a Two-Stage Cryogenerator (both 90 Kelvin and 20 Kelvin) with each stage having an independently controlled circulation loop. The bulk of the heat load is intercepted by the 90 Kelvin loop via a thin foil heat exchanger internal to the insulation blankets (also known as a Broad Area Cooling Shield), with the remainder removed at cryofluid temperature (20 Kelvin) by tubes directly welded to the outer tank surface. In this paper, we examine the challenges of controlling the system, and describe the development of control algorithms and software for future testing with liquid hydrogen. The interactions between the cryofans which control circulation loop mass flow rates, electrical heaters which vary the cryocooler lift to simulate the operation of variable-lift flight units, tank heaters which can vary the overall heat load, and the effects of changes in circulation loop pressure as temperatures change, can be complex and must be well understood to maintain steady-state propellant conditions and achieve Zero Boil-Off. Parallel PID loops and watchdog programs implemented on the user interface system will help bring the systems to steady state operation and keep them at selected operating points within acceptable error, while avoiding runaway feedback loops.

cryogenics↗

Visible and Infrared Imaging of Various Flow Regimes in the Flow Boiling and Condensation Experiment Transfer Line

The Flow Boiling and Condensation Experiment (FBCE) Transfer Line (TL) test module is being developed to study fluid physics of cryogenic transfer lines in microgravity. The TL module will reside in the FBCE facility located within the Fluids Integration Rack (FIR) aboard the International Space Station (ISS). TL will use the same normal perfluoro hexane (nPFH) used in the previous FBCE test sections. To simulate cryogenic line transfer in the visualization section, a sapphire tube coated with indium tin oxide (ITO) is heated via Joule heated while a bypass line is used to flow liquid nPFH at the desired inlet conditions. Once the visualization line reaches steady-state temperature and pressure conditions, flow is diverted through the heated line and chilldown begins. All flow regimes observed within a cryogenic TL are created and studied using visible imaging with diffuse backlighting to image inverted annular flow, transition, and nucleate boiling. A visible laser light sheet provided by FIR will provide a means to observe and track droplets in the dispersed flow regime. IR imaging of the visualization tube outer surface with the emissivity of the ITO coating provides the surface chilldown temperature profile. Preliminary imaging system development includes some of the components used in the Flow Boiling Module (FBM) and some new components that are easily integrated into the PC-based system but will require some refinement to operate properly on the FIR PCIe/104 imaging system. Optical design and packaging within the limited volume of the module enclosure is also presented. This paper presents FBCE-TL visible and infrared laboratory-based imaging studies and anticipated visualization capabilities of the TL module under preliminary breadboard development and under the utilization constraints within the FBCE/FIR host facility.

transfer line↗

Experimental Investigation of Flow Orientation Effects on Cryogenic Flow Boiling

Cryogenic flow boiling physics is of paramount importance for future cryogenic space applications employing Cryogenic Fluid Management (CFM) technologies. This experimental study investigates the two-phase flow and heat transfer performance of LN 2 flow boiling across five distinct flow orientations: vertical upflow, vertical downflow, horizontal flow, 45° inclined upflow, and 45° inclined downflow. The study employed the steady- state heating method within a circular heated tube featuring an 8.5-mm inner diameter and a 680-mm heated length. High-speed video recordings were utilized to capture two-phase flow patterns and interfacial behaviors across various flow orientations. The experiments covered a wide range of operating conditions, including mass velocities ranging from 351.80 to 1572.77 kg/m 2 s and inlet pressures from 297.14 to 1032.97 kPa, primarily with near-saturated inlet subcooling. Distinct two-phase flow patterns and regime transitions were identified for each flow orientation. Symmetrical flow patterns were evident in vertical orientations, whereas non-vertical orientations exhibited asymmetric flow stratifications, primarily influenced by the buoyancy force in a terrestrial gravity environment. Bubble dynamic parameters were quantified, and bubble collision and dispersion phenomena were visualized. Analyzing heat transfer performance based on local flow boiling curves and variations in heat transfer coefficients (HTCs), it was observed that vertical upflow demonstrated the most enhanced heat transfer performance, while vertical downflow exhibited the lowest. As mass velocity exceeded 830 kg/ m 2 s, the differences in heat transfer among orientations became less distinct, emphasizing the role of flow inertia in mitigating the influence of flow orientation. A direct comparison of microgravity HTC data from a recent study by the authors against the 1-𝘨 e HTC data indicated enhanced heat transfer performance in microgravity for flow orientation configurations in terrestrial gravity. However, this enhancement progressively diminished as the heat flux increased. Distinct HTC trends were observed as mass velocity increased for different flow orientations and gravity levels.

Cryogens↗

Unified descriptor for enhanced critical heat flux during pool boiling of hemi-wicking surfaces

Boiling heat transfer is dictated by interfacial phenomena at the three-phase contact line where vapor bubbles form on the surface. Structured surfaces have shown significant enhancement in critical heat flux (CHF) during pool boiling by tailoring interfacial phenomena. This CHF enhancement has been primarily explained by two structural effects: roughness, which extends the contact line length at the bubble base, and wickability, the ability to imbibe liquid through surface structures by capillary pumping. Here, in this work, we show that CHF enhancement on structured surfaces cannot be described by roughness or wickability alone. This result was confirmed using systematically designed micropillar surfaces with controlled roughness and wickability. Further, we performed a scaling analysis and derived a unified descriptor, which represents the combined effects of thin film density and volumetric wicking rate. This unified descriptor shows a reasonable correlation with CHF values with our experiments and literature data. This work provides important insights in understanding the role of surface structures on CHF enhancement, thereby providing guidelines for the systematic design of surface structures for enhanced pool boiling heat transfer.

42 ENGINEERING↗

Properties and Autoignition Reactivity of Diesel Boiling Range Ethers Produced from Guerbet Alcohols

We examine the properties of diesel boiling range ethers made from coupling of alcohols produced by oligomerization of ethanol (Guerbet alcohols) for their utility as low-carbon liquid fuel blendstocks. Basic properties of boiling point, flash point, freezing point, density and viscosity are well suited for blending into diesel fuels. For the mixture of ethers the lightest component, di-n-butyl ether, can be present at up to 20 vol% while still having adequately high flashpoint for safe handling. Soot formation tendency (as yield sooting index) is well below that of conventional diesel. The ethers have similar compatibility with elastomers as conventional diesel, based on Hansen solubility parameter analysis. Oxidation stability was assessed for 30 vol% blends of individual ethers in a conventional diesel fuel using a long-term storage test. Over 6 weeks we observed no formation of peroxides or degradation. n-alkyl ethers with carbon number of 8 or higher have cetane number over 100, which is outside the defined range of cetane number, while branched ethers are over 70. The ethers also blend antagonistically into conventional diesel for cetane number, meaning that the blend cetane value is lower than predicted based on a linear by volume, mass, or mole model. We show that aromatics and naphthenes likely act as radical scavengers to slow or shut down autoignition of the highly reactive ethers at low to medium blend levels. Overall, diesel boiling range ethers show significant promise as high quality low-net carbon diesel blendstocks.

09 BIOMASS FUELS↗

Use of boiled hexamethylenetetramine and urea to increase the porosity of cerium dioxide microspheres formed in the internal gelation process

Cerium dioxide (CeO 2 ) is a commonly used simulant for plutonium dioxide and for plutonium (Pu) in a mixed uranium (U) and Pu oxide [(U, Pu)O 2 ] in nuclear fuel development. This effort developed CeO 2 microspheres with different porosities and diameters for use in a crush-strength study. The internal gelation technique has produced CeO 2 microspheres with limited initial porosity. When an equal molar solution of urea and hexamethylenetetramine (HMTA) is gently boiling for 1 hr and used in the gelation process, the crystallite size and porosity of mixed U and thorium oxide microspheres and the (U, Pu)O 2 microspheres increased significantly. In this study with cerium, the combination of ammonium cerium nitrate and 1-h boiled HMTA-urea failed to produce a stable feed broth. However, when the 1-h heated HMTA-urea was combined with unheated HMTA-urea in 1 to 3 volume ratio or the boiling time of the HMTA-urea was reduced to 15-20 min, a stable solution of HMTA, urea, and Ce was formed at 273 K. This new Ce solution produced CeO 2 microspheres with much higher initial porosities. Intermediate porosities were possible when the heated HMTA/urea was aged prior to use.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Bubble departure and sliding in high-pressure flow boiling of water

Bubble growth, departure and sliding in low-pressure flow boiling has received considerable attention in the past. However, most applications of boiling heat transfer rely on high-pressure flow boiling, for which very little is known, as experimental data are scarce and very difficult to obtain. In this work, we conduct an experiment using high-resolution optical techniques. By combining backlit shadowgraphy and phase-detection imaging, we track bubble shape and physical footprint with high spatial ($6\,\mathrm {\mu }{\rm m}$) and temporal ($33\,\mathrm {\mu }{\rm s}$) resolutions, as well as bubble size and position as bubbles nucleate and slide on top of the heated surface. We show that at pressures above 1 MPa bubbles retain a spherical shape throughout the growth and sliding process. We analytically derive non-dimensional numbers to correlate bubble velocity and liquid velocity throughout the turbulent boundary layer and predict the sliding of bubbles on the surface, solely from physical properties and the bubble growth rate. We also show that these non-dimensional solutions can be leveraged to formulate elementary criteria that predict the effect of pressure and flow rate on bubble departure diameter and growth time.

Mechanics↗

Insight into pseudo-film-boiling in supercritical water under simplified interfacial conditions

The focus of this paper is the physics of supercritical water film boiling through the simulation of natural convection of supercritical water in a rectangular cavity. It has been widely believed that above a fluid's critical point, only one phase exists. However, recent research has indicated the existence of distinct gas-like and liquid-like regions separated by the Widom line, which is the locus of the maxima of the specific heat. Along the Widom line, density decreases sixfold, viscosity drops by a factor of two, while specific heat spikes by an order of magnitude. These variations, specifically in density and viscosity, produce a thick pseudo-interface and flow dynamics behavior akin to film-boiling, denoted here as pseudo-two-phase flow dynamics. When the cavity is heated from the bottom, a pseudo-film of gas-like fluid is formed at the heated wall, and the flow complexity evolves, characterized by the formation of multiple vortices. Results demonstrate the ability of modern conjugate heat transfer computational fluid dynamics to capture the pseudo two-phase regime, with the formation of a pseudo-film at the heated wall. Further, the boiling curve is studied, showing an increase in heat flux with an increase in the temperature differential between the wall and the pseudo-critical temperature. Furthermore, results also show a previously uncharacterized instability, where the convection cells in the cavity oscillate and can flip directions under certain conditions.

Computational fluid dynamics↗

Modification in Applying Appendix D of 40 CFR Part 61 to Heated Solid Radionuclide Materials With High Melting and Boiling Points

Appendix D of Title 40 Part 61 of the US Code of Federal Regulations (CFR) provides a procedure that US Department of Energy (US DOE) facility owners and operators can use to estimate radionuclide emissions to the atmosphere for dose calculations instead of measuring emissions for minor sources under the 40 CFR Part 61, Subpart H, National Emission Standards for Emissions of Radionuclides Other Than Radon From Department of Energy Facilities, regulation. The procedure assumes that any radioactive material heated above 100 °C is completely vaporized and emitted to the atmosphere. In 1991, the US DOE Oak Ridge Reservation (ORR) requested approval to use different release fractions (RFs) for uranium because of its high melting and boiling points. In response to the request, the US Environmental Protection Agency (US EPA) Region IV approved the use of modified RFs for elemental uranium provided no reaction had taken place to alter its chemical form. In 2015, the ORR requested approval to use different RFs for tungsten, again because of its high melting and boiling points. EPA Region IV approved the use of modified RFs for heated radioactive tungsten metal. In accordance with the two precedents set for heating uranium and radioactive tungsten metals, in 2016, the ORR requested approval to use modified RFs in a similar fashion for other radioactive solid metals and compounds with melting and boiling points above 500 °C that might be heated above 100 °C in future research projects and experiments. EPA Region IV again granted approval to use modified RFs for the list of compounds. This note discusses the proposed modified RFs and their development.

36 MATERIALS SCIENCE↗

Heat transfer and visual observation of pool boiling of next-generation low-pressure refrigerant: R1336mzz(Z)

R1336mzz(Z) is a non-flammable and non-toxic hydrofluoroolefin (HFO), which is a potential alternative working fluid for multiple applications such as centrifugal chillers, industrial high temperature heat pumps, and Organic Rankine Cycles. Pool boiling is one of the primary heat transfer modes in shell-and-tube evaporators, and there is limited data for R1336mzz(Z) due to its recent introduction. This study investigated the pool boiling characteristics of R1336mzz(Z) using a closed-loop apparatus. Heat transfer coefficients on a smooth aluminum surface were measured at various heat fluxes with a heating block, and the results were compared to predictions from various correlations. Additionally, a high-speed camera was employed to visualize and analyze the pool boiling behavior of this next-generation low-pressure refrigerant.

Yang, Cheng-Min [ORNL]↗

Experimental Investigation of Coolant Boiling in a Half-Heated Circular Tube - Final CRADA Report

Coolant subcooled boiling in the cylinder head regions of heavy-duty vehicle engines is unavoidable at high thermal loads due to high metal temperatures. However, theoretical, numerical, and experimental studies of coolant subcooled flow boiling under these specific application conditions are generally lacking in the engineering literature. The objective of this project was to provide such much-needed information, including the coolant subcooled flow boiling characteristics and the corresponding heat transfer coefficients, through experimental investigations.

36 MATERIALS SCIENCE↗

Building 1090 Boil-Off Exhaust Modifications 90% Basis of Design

This document provides analysis and proposed modifications to correct current issues at Building 1090. Electrical modifications will add additional emergency Iighting in Labs 170, 174, 178, 182, 184, 186, and 190, and back-up power for the exhaust systems, fume hood lighting and exhaust system controls during a power outage. Mechanical modifications will address building pressurization between the lab and office areas, and replacement of corroded exhaust ductwork and fume hoods related to boil-off operations of corrosive chemicals. Mechanical modifications include the installation of a dedicated, chemical boil-off exhaust fan and ductwork to support corrosive boil-off operations in Lab 184. It should be noted that the proposed solution increases the overall building exhaust demand, also increasing the supply air needed. Electrical modifications include the installation of an uninterruptible power supply (UPS) to provide power to the exhaust fan, controls, and fume hoods to allow safe exit from Laboratory 186 during a power outage. The existing lighting inverter will also be replaced with a larger model to support additional emergency lighting within the labs. Architectural modifications include exterior doors on the east wall of the IDR room. An additional door in the corridor west of Lab 184 will provide direct access to Lab 186 without entering a common building corridor. Lab casework will be modified as-required to accommodate the new layout.

42 ENGINEERING↗

A review on film boiling

Film boiling covering drops and puddles, pool boiling for various geometries and forced convective film boiling

Hsu, Y. Y.↗

Diffusive and radiative effects on vaporization times of drops in film boiling

Diffusive and radiative effects are incorporated into an analysis for the vaporization time of drops in film boiling. The momentum, energy, and continuity equations are solved with some appropriate simplifications so as to obtain a simple closed form solution for the overall film boiling heat transfer coefficient. Next, a theoretical expression for the droplet vaporization time is developed and compared to the measured vaporization times of water droplets vaporizing into air, argon, nitrogen, and helium. The agreement between experiment and theory is good. Under the helium blanket, the diffusive evaporative component is significant in comparison to the film boiling component.

Baumeister, K. J.↗