Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM CURRENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Li+ alumino-silicate ion source development for the Neutralized Drift Compression Experiment (NDCX-II)

To heat targets to electron-volt temperatures for the study of warm dense matter with intense ion beams, low mass ions, such as lithium, have an energy loss peak (dE/dx) at a suitable kinetic energy. The Heavy Ion Fusion Sciences (HIFS) program at Lawrence Berkeley National Laboratory will carry out warm dense matter experiments using Li{sup +} ion beam with energy 1.2-4 MeV in order to achieve uniform heating up to 0.1-1 eV. The accelerator physics design of Neutralized Drift Compression Experiment (NDCX-II) has a pulse length at the ion source of about 0.5 {micro}s. Thus for producing 50 nC of beam charge, the required beam current is about 100 mA. Focusability requires a normalized (edge) emittance {approx}2 {pi}-mm-mrad. Here, lithium aluminosilicate ion sources, of {beta}-eucryptite, are being studied within the scope of NDCX-II construction. Several small (0.64 cm diameter) lithium aluminosilicate ion sources, on 70%-80% porous tungsten substrate, were operated in a pulsed mode. The distance between the source surface and the mid-plane of the extraction electrode (1 cm diameter aperture) was 1.48 cm. The source surface temperature was at 1220 C to 1300 C. A 5-6 {micro}s long beam pulsed was recorded by a Faraday cup (+300 V on the collector plate and -300 V on the suppressor ring). Figure 1 shows measured beam current density (J) vs. V{sup 3/2}. A space-charge limited beam density of {approx}1 mA/cm{sup 2} was measured at 1275 C temperature, after allowing a conditioning time of about {approx} 12 hours. Maximum emission limited beam current density of {ge} 1.8mA/cm{sup 2} was recorded at 1300 C with 10-kV extractions. Figure 2 shows the lifetime of two typical sources with space-charge limited beam current emission at a lower extraction voltage (1.75 kV) and at temperature of 1265 {+-} 7 C. These data demonstrate a constant, space-charge limited beam current for 20-50 hours. The lifetime of a source is determined by the loss of lithium from the alumino-silicate material either as ions or as neutral atoms. Our measurements suggest that for the low duty factor ({approx}10{sup -8}) required for NDCX-II, the lifetime of an emitter depends mostly on the duration that the emitter spends at elevated temperature, that is, at {ge} 1250 C. At this temperature, lithium loss is due mostly to neutral loss (not charged ion extraction). Extension of the lifetime of the source may be possible by lowering the temperature between beam pulses, when the idling time is sufficiently long between shots. The NDCX-II design seeks to operate the ion source at the maximum current density without running into heat management and lifetime problems. In preparation to fabricate a large (10.9 cm in diameter) source for the NDCXII experiment, recently a 7.6 cm diameter source has been fabricated. The method of fabrication of this larger source is similar to that of fabrication of a 6.3mm diameter source, except a longer furnace heating time was used due to mass differences. NDCX-II construction is in progress. Progress of lithium source study for NDCX-II is available in literature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-189: Commission Range Shifter On a Spot Scanning Proton System Using Raystation Treatment Planning System

Purpose: To treat superficial target e.g. chest wall, head&neck or cranial cases, we commissioned two range shifter(RS) in Raystation4.0 with 7.37cm(RS1) and 4.1cm(RS2) Water Equivalent Thickness(WET) respectively. However, current beam model has limitations due to the secondary scattered proton. This study provides a detailed and critical commission data and provides suggestions for using RS in clinic. Methods: RS’ WET was verified by Multi-Layer Ionization Chamber from 120MeV to 226.7MeV before TPS modeling. Spot characteristics were measured using 2D scintillate detector at ISO with different air gap. A 8×8×10cm3 cube is created in 8cm depth of water to verify the absolute dose accuracy. Plans were created with different air gap using both RS. Absolute dose verification was measured along the central axis from distal end to surface using PPC05. 10 clinical RS2 plans were measured using MatriXXPT in 3 planes (proximal, distal and midSOBP). Results: RS material’s proton stopping power is energy dependent(from 70MeV to 226.7MeV) ranging from 7.42 to 7.31cm and from 4.10 to 4.03cm respectively. We chose 7.37cm (RS1) and 4.10cm (RS2) to favor the low and median proton energy. With different air gap(3cm to 32cm), spot size expands from 3.2mm to 5.5mm(RS1) and from 3.1mm to 4.1mm(RS2) respectively(226.7MeV in air, 1-sigma). For the absolute dose verification, the larger air gap and shallower depth causes larger discrepancy between TPS and measurements. All 10 clinical plans with 5–10cm air gap passed gamma index 95% with 3%/3mm criteria and outputs differences were within 3%. Conclusion: We strongly recommend each institution to verify the WET independently and choose the value to fit the clinical needs. To minimize the output difference in Raystation4.0 while avoid potential collision to the patient, we recommend to use 5–10cm air gap to minimize the output difference within 2% and preferably use RS with smaller WET if possible.

60 APPLIED LIFE SCIENCES↗

Towards a Precision Measurement of Parity-Violating e-p Elastic Scattering at Low Momentum Transfer

The goal of the Q-weak experiment is to make a measurement of the proton's weak charge Q W p = 1 - 4 sin 2 (θ W 2 (θ W 2 (θ W W p by measuring the parity violating asymmetry in elastic electron-proton scattering at low momentum transfer Q 2 = 0.026 (GeV/c) 2 and forward angles (8 degrees). The anticipated size of the asymmetry, based on the SM, is about 230 parts per billion (ppb). With the proposed accuracy, the experiment may probe new physics beyond Standard Model at the TeV scale. This thesis focuses on my contributions to the experiment, including track reconstruction for momentum transfer determination of the scattering process, and the focal plane scanner, a detector I designed and built to measure the flux profile of scattered electrons on the focal plane of the Q-weak spectrometer to assist in the extrapolation of low beam current tracking results to high beam current. Preliminary results from the commissioning and the first run period of the Q-weak experiment are reported and discussed.

43 PARTICLE ACCELERATORS↗

Studies on a Q/A selector for the SECRAL electron cyclotron resonance ion source

Electron cyclotron resonance ion sources are widely used in heavy ion accelerators in the world because they are capable of producing high current beams of highly charged ions. However, the design of the Q/A selector system for these devices is challenging, because it must have a sufficient ion resolution while controlling the beam emittance growth. Moreover, this system has to be matched for a wide range of ion beam species with different intensities. In this paper, research on the Q/A selector system at the SECRAL (Superconducting Electron Cyclotron Resonance ion source with Advanced design in Lanzhou) platform both in experiment and simulation is presented. Based on this study, a new Q/A selector system has been designed for SECRAL II. The features of the new design including beam simulations are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parametric Modeling of Electron Beam Loss in Synchrotron Light Sources

Synchrotron light is used for a wide variety of scientific disciplines ranging from physical chemistry to molecular biology and industrial applications. As the electron beam circulates, random single-particle collisional processes lead to decay of the beam current in time. We report a simulation study in which a combined neural network (NN) and first-principles (FP) model is used to capture the decay in beam current due to Touschek, Bremsstrahlung, and Coulomb effects. The FP block in the combined model is a parametric description of the beam current decay where model parameters vary as a function of beam operating conditions (e.g. vertical scraper position, RF voltage, number of the bunches, and total beam current). The NN block provides the parameters of the FP model and is trained (through constrained nonlinear optimization) to capture the variation in model parameters as operating condition of the beam changes. Simulation results will be presented to demonstrate that the proposed combined framework accurately models beam decay as well as variation to model parameters without direct access to parameter values in the model.

43 PARTICLE ACCELERATORS↗

Performance Evaluation Of An Irradiation Facility Using An Electron Accelerator

Irradiation parameters over a period of seven years have been evaluated for a radiation processing electron accelerator facility. The parameters monitored during this time were the electron beam energy, linearity of beam current, linearity of dose with the reciprocal value of the samples speed, and dose uniformity along the scanning area after a maintenance audit performed by the electron accelerator manufacturer. The electron energy was determined from the depth-dose curve by using a two piece aluminum wedge and measuring the practical range from the obtained curves. The linearity of dose with beam current, and reciprocal value of the speed and dose uniformity along the scanning area of the electron beam were determined by measuring the dose under different beam current and cart conveyor speed conditions using film dosimetry. The results of the experiments have shown that the energy in the range from 1 to 5 MeV has not changed by more than 15% from the High Voltage setting of the machine over the evaluation period, and dose linearity with beam current and cart conveyor speed has not changed. The dose uniformity along the scanning direction of the beam showed a dose uniformity of 90% or better for energies between 2 and 5 MeV, however for 1 MeV electrons this value was reduced to 80%. This parameter can be improved by changing the beam optics settings in the control console of the accelerator though.

43 PARTICLE ACCELERATORS↗

Ramping up the SNS Beam Power with the H- Source using 0 mg Cs/Day

This paper describes the ramp up of the beam power for the Spallation Neutron Source by ramping up the pulse length, the repetition rate, and the beam current emerging from the H- source. Starting out with low rep rates (<10 Hz) and short pulse lengths (<<0.3 ms) the H- source and LEBT delivered from LBNL exceeded the requirements with almost perfect availability. This paper discusses the modifications that were required to exceed 0.2 ms pulse length and 0.2% duty factor with acceptable availability and performance. Currently the source is supporting neutron production at 1 MW with 38 mA LINAC beam current at 60 Hz and 0.9 ms pulse length. The pulse length will be increased to ~1.1 ms to meet the requirements for neutron production with a power between 1 and 1.4 MW. A MEBT beam current of 46 mA with a 5.4% duty factor has been demonstrated for 32 hours. A 56mA MEBT beam current with a 4.1% duty factor has been demonstrated for 20 minutes at the conclusion of a 12 day production run. This is close to the 59 mA needed for 3 MW neutron productions. Also notable is the Cs2CrO4 cesium system, which dispenses ~10 mg of Cs during the startup of the ion source, sufficient for producing the required 38 mA for 4 weeks without significant degradation.

H- source↗

Apex Study: Compensating Transient Beam Loading in the RHIC 28 MHZ

With the EIC on the way, it is important that developments and strategies are in place to deal with the very high beam currents that the machine will feature. Specifically, the EIC will collide beams of up to 2.5 A, three times the beam current in RHIC. This higher beam current will cause significant voltage transients in the cavity fields which can lead to longitudinal instabilities and beam loss. In anticipation of these negative effects, studies were carried out on the RHIC 28 MHz cavities using newly developed firmware and software to diagnose and combat beam loading. Diagnostic tools such as the bunch-by-bunch (BbyB) ADC firmware and digital network analyzer (DNA) were used to characterize the closed loop system and transient on the cavity voltage magnitude and phase. Then, a one-turn delay feedback (OTFB) and adaptive feed-forward (aFFWD) were used to minimize the transient beam loading. The studies were carried out with beam during 2 accelerator physics experiements (APEXs) using one of the 28 MHz accelerating cavities here at RHIC.

43 PARTICLE ACCELERATORS↗

DCS - A high flux beamline for time resolved dynamic compression science – Design highlights

The Dynamic Compression Sector (DCS) beamline, a national user facility for time resolved dynamic compression science supported by the National Nuclear Security Administration (NNSA) of the Department of Energy (DOE), has recently completed construction and is being commissioned at Sector 35 of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The beamline consists of a First Optics Enclosure (FOE) and four experimental enclosures. A Kirkpatrick–Baez focusing mirror system with 2.2 mrad incident angles in the FOE delivers pink beam to the experimental stations. A refocusing Kirkpatrick–Baez mirror system is situated in each of the two most downstream enclosures. Experiments can be conducted in either white, monochromatic, pink or monochromatic-reflected beam mode in any of the experimental stations by changing the position of two interlocked components in the FOE. The beamline Radiation Safety System (RSS) components have been designed to handle the continuous beam provided by two in-line revolver undulators with periods of 27 and 30 mm, at closed gap, 150 mA beam current, and passing through a power limiting aperture of 1.5 x 1.0 mm{sup 2}. A novel pink beam end station stop [1] is used to stop the continuous and focused pink beam which can achieve a peak heat flux of 105 kW/mm{sup 2}. A new millisecond shutter design [2] is used to deliver a quick pulse of beam to the sample, synchronized with the dynamic event, the microsecond shutter, and the storage ring clock.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Cyclotron Targetry to Enhance F-18 clinical Position Emission Tomography

This project proposes to develop cyclotron targets that produce F-18 for clinical Positron Emission Tomography (PET) at significantly higher rates than that available from current targetry. This production rate of 18F is directly proportional to the beam current. Higher beam currents would result in increased 18F production but would be accompanied by higher heat loads to the target. The beam power available in most commercial cyclotrons exceeds the heat removal capacity of current target technology by a factor of two to four, significantly limiting the production rate of Fluorine-18.

43 PARTICLE ACCELERATORS↗

Investigations on residual strains and the cathodoluminescence and electron beam induced current signal of grain boundaries in silicon

Cathodoluminescence (CL) and electron beam induced current (EBIC) measurements were used to investigate the optical behavior and electrical activity of grain boundaries (GBs) in coarsely grained silicon. Electron backscatter diffraction (EBSD) was applied for a comprehensive characterization of the structural properties of the high angle and low angle GBs (HAGBs and LAGBs) in the sample. It was found that not only the EBIC but also the panchromatic (pan) CL contrast of Σ3 HAGBs strongly depends on the hkl-type of the boundary plane. At room temperature coherent Σ3 GBs exhibit no significant contrast in the CL or EBIC images, whereas at low temperatures the pan-CL contrast is strong. For incoherent Σ3 GBs, a strong pan-CL and EBIC contrast was observed in the entire temperature range. Only on a LAGB (misorientation angle 4.5°) CL investigations at low temperatures revealed a line with peak position at about (0.82 ± 0.01) eV, usually related to the dislocation associated D1 transition. Cross-correlation EBSD was applied to analyze the strain fields of Σ3 HAGBs as well as of the LAGB. All the components of the local strain tensors were quantitatively determined. The relationship between the extension of the strain field at the LAGB and the spatial D1 intensity distribution is discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A theoretical study of the effects of interacting grain boundaries on electron-beam-induced currents

The influence of several grain boundaries on the electron-beam-induced current in polycrystalline silicon is investigated. The simple geometry contemplated here, consisting of two plane parallel grain boundaries possessing different effective, albeit constant, surface recombination velocities, intersecting a planar junction at right angles allows for an exact solution of the corresponding boundary value problem. It is shown that if the distance between the grain boundaries w becomes less than the diffusion length for minority carriers L within the grain, the grain boundary with the smaller effective recombination velocity becomes less and less visible the smaller the ratio w/L.

Luke, K. L.↗

rf improvements for Spallation Neutron Source H{sup -} ion source

The Spallation Neutron Source at Oak Ridge National Laboratory is ramping up the accelerated proton beam power to 1.4 MW and just reached 1 MW. The rf-driven multicusp ion source that originates from the Lawrence Berkeley National Laboratory has been delivering {approx}38 mA H{sup -} beam in the linac at 60 Hz, 0.9 ms. To improve availability, a rf-driven external antenna multicusp ion source with a water-cooled ceramic aluminum nitride (AlN) plasma chamber is developed. Computer modeling and simulations have been made to analyze and optimize the rf performance of the new ion source. Operational statistics and test runs with up to 56 mA medium energy beam transport beam current identify the 2 MHz rf system as a limiting factor in the system availability and beam production. Plasma ignition system is under development by using a separate 13 MHz system. To improve the availability of the rf power system with easier maintenance, we tested a 70 kV isolation transformer for the 80 kW, 6% duty cycle 2 MHz amplifier to power the ion source from a grounded solid-state amplifier.

43 PARTICLE ACCELERATORS↗

Development of C{sub 60} plasma ion source for time-of-flight secondary ion mass spectrometry applications

Initial data from a multicusp ion source developed for buckminsterfullerene (C{sub 60}) cluster ion production are reported in this article. A C{sub 60}{sup +} beam current of 425 nA and a C{sub 60}{sup -} beam current of 200 nA are obtainable in continuous mode. Compared to prior work using electron impact ionization, the multicusp ion source provides at least two orders of magnitude increase in the extractable C{sub 60}{sup +} beam current. Mass spectra for both positive and negative bismuth cluster ions generated by the multicusp ion source are also included.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Space-charge compensation measurements in electron cyclotron resonance ion source low energy beam transport lines with a retarding field analyzer

In this paper we describe the first systematic measurement of beam neutralization (space charge compensation) in the ECR low energy transport line with a retarding field analyzer, which can be used to measure the potential of the beam. Expected trends for the space charge compensation levels such as increase with residual gas pressure, beam current, and beam density could be observed. However, the overall levels of neutralization are consistently low (<60%). The results and the processes involved for neutralizing ion beams are discussed for conditions typical for ECR injector beam lines. The results are compared to a simple theoretical beam plasma model as well as simulations.

43 PARTICLE ACCELERATORS↗

Single and Multi-bunch End-to-end Tracking in the LHeC

The LHeC study aims at delivering an electron beam for collision with the LHC proton beam. The current baseline design consists of a multi-pass superconductive energy-recovery linac operating in a continuous wave mode. The high current beam (~100 mA) in the linacs excites long-range wake-fields between bunches of different turns, which induce instabilities and might cause beam losses. PLACET2, a novel version of the tracking code PLACET, capable to handle recirculation and time dependencies, has been employed to perform the first LHeC end-to-end tracking. The impact of long-range wake-fields, synchrotron radiation, and beam-beam effects has been assessed. The simulation results and recent improvements in the lattice design are presented and discussed in this paper.

Pellegrini, Dario↗

Machine learning at the Spallation Neutron Source accelerator and target

We describe the ongoing efforts to apply Machine Learning techniques to improve the performance of our accelerator and target. Specially, we are looking to minimize halo beam losses in the absence of a proper physics model, automatically detect and log anomalies in the target support systems such as cooling, and detect and prevent errant beam pulses in the linac. We also describe the infrastructure we use to acquire and stream data to the GPU cluster for training, our code development cycle, and edge computing for model inference. To minimize halo beam losses, we use a Reinforcement Learning technique tested on a virtual accelerator. The target anomaly detection is trained on archived data using incomplete physics models and is made part of the existing target reporting system. The errant beam prevention analyzes beam current and beam phase waveforms as well as accelerator configuration data to predict errant pulses. We also develop continual learning to adapt to changes in the accelerator.

Accelerator Physics↗

Safe operating conditions for NSLS-II Storage Ring Frontends commissioning

The NSLS-II Storage Ring Frontends are designed to safely accept the synchrotron radiation fan produced by respective insertion device when the electron beam orbit through the ID is locked inside the predefined Active Interlock Envelope. The Active Interlock is getting enabled at a particular beam current known as AI safe current limit. Below such current the beam orbit can be anywhere within the limits of the SR beam acceptance. During the FE commissioning the beam orbit is getting intentionally disturbed in the particular ID. In this paper we explore safe operating conditions for the Frontends commissioning.

43 PARTICLE ACCELERATORS↗