Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BACKGROUND NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A multi-dataset data-collection strategy produces better diffraction data

Theoretical analysis and experimental validation prove that a multi-dataset data-collection strategy produces better diffraction data. The readiness test is a simple and sensitive method for X-ray data-collection system evaluation and a benchmark. A multi-dataset (MDS) data-collection strategy is proposed and analyzed for macromolecular crystal diffraction data acquisition. The theoretical analysis indicated that the MDS strategy can reduce the standard deviation (background noise) of diffraction data compared with the commonly used single-dataset strategy for a fixed X-ray dose. In order to validate the hypothesis experimentally, a data-quality evaluation process, termed a readiness test of the X-ray data-collection system, was developed. The anomalous signals of sulfur atoms in zinc-free insulin crystals were used as the probe to differentiate the quality of data collected using different data-collection strategies. The data-collection results using home-laboratory-based rotating-anode X-ray and synchrotron X-ray systems indicate that the diffraction data collected with the MDS strategy contain more accurate anomalous signals from sulfur atoms than the data collected with a regular data-collection strategy. In addition, the MDS strategy offered more advantages with respect to radiation-damage-sensitive crystals and better usage of rotating-anode as well as synchrotron X-rays.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of Absorption Coefficient of Paraformaldehyde and Metaldehyde with Terahertz Spectroscopy

The characteristic absorption spectra of paraformaldehyde and metaldehyde in the terahertz frequency region are obtained by terahertz time-domain spectroscopy (THz-TDS). In order to reduce the absorption of terahertz (THz) wave by water vapor in the air and the background noise, the measurement system was filled with dry air and the measurements were conducted at the temperature of 24°C. Meanwhile, the humidity was controlled within 10% RH. The THz frequency domain spectra of samples and their references from 0 to 2.5 THz were analyzed via Fourier transform. The refractive index and absorption coefficients of the two aldehydes were calculated by the model formulas. From 0.1 to 2.5 THz, there appear two weak absorption peaks at 1.20 and 1.66 THz in the absorption spectra of paraformaldehyde. Only one distinct absorption peak emerges at 1.83 THz for metaldehyde. There are significant differences between the terahertz absorption coefficients of paraformaldehyde and metaldehyde, which can be used as 'fingerprints' to identify these substances. Furthermore, the relationship between the average absorption coefficients and mass concentrations was investigated and the average absorption coefficient–mass concentration diagrams of paraformaldehyde and metaldehyde were shown. For paraformaldehyde, there is a linear relationship between the average absorption coefficient and the natural logarithm of mass concentration. For metaldehyde, there exists a simpler linear relationship between the average absorption coefficient and the mass concentration. Because of the characteristics of THz absorption of paraformaldehyde and metaldehyde, the THz-TDS can be applied to the qualitative and quantitative detection of the two aldehydes to reduce the unpredictable hazards due to these substances.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a Convolutional Neural Network Classifier for Data Starved Spectra - 20199

The Institute for Clean Energy Technology (ICET) at Mississippi State University is exploring the utility of machine learning in augmenting its mobile radiation surveying platforms, which are currently being developed as means to survey depleted uranium contaminated areas in support of remediation and decommissioning efforts. Mobile survey platforms provide a means to efficiently scan large areas of interest while reducing human exposure to radiation and other hazards. The survey platforms can also be used for scanning for any gamma emitting isotope in addition to depleted uranium. The spectral data that the platforms collect may be data starved with relatively low counts and poorly defined spectral features depending on the speed of the platforms and scintillation detector selection. Such data-starved spectra are difficult to use for isotope identification, requiring advanced knowledge of the possible radionuclides that could be present and environmental factors that could attenuate signals or introduce background noise. These factors in combination with the volume of survey data increases the time it takes to perform analysis of survey data when the source type is unknown. There are a number of algorithms in the field of machine learning that can be used to classify data that would be challenging and time-consuming for a human to identify. Supervised machine learning algorithms train models based on extensive amounts of human-labeled training data. Once sufficiently trained, these models can be used to quickly make high-fidelity predictions on new data. Convolutional neural networks are machine learning algorithms that excel in learning representations of 'shapes'. They do this by taking numerical input data and convolving them with spatial feature detectors referred to as filters. These filters are incrementally adjusted to reduce the prediction error on the data during the backpropagation step of training. Discussed in this paper is the development of a convolutional neural network classifier (CNNC) that can utilize spectral survey data for source discrimination and isotope identification. Bench-top laboratory experiments data using LaBr{sub 3}(Ce) scintillation detectors were used to train and evaluate the performance of the developed CNNC. The CNNC is capable of discriminating a variety of gamma emitting source types, differentiating different forms of uranium (depleted vs. natural), and estimating the amount of uranium for a known geometry. The discussed CNNC may be useful in scenarios where survey systems are deployed in situations where hazardous radioactive material maybe present, but the type is unknown. When used in remediation applications the CNNC can be used to screen-out false positives, helping reduce remediation costs. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

DECONVOLUTION OF IMAGES FROM BLAST 2005: INSIGHT INTO THE K3-50 AND IC 5146 STAR-FORMING REGIONS

We present an implementation of the iterative flux-conserving Lucy-Richardson (L-R) deconvolution method of image restoration for maps produced by the Balloon-borne Large Aperture Submillimeter Telescope (BLAST). Compared to the direct Fourier transform method of deconvolution, the L-R operation restores images with better-controlled background noise and increases source detectability. Intermediate iterated images are useful for studying extended diffuse structures, while the later iterations truly enhance point sources to near the designed diffraction limit of the telescope. The L-R method of deconvolution is efficient in resolving compact sources in crowded regions while simultaneously conserving their respective flux densities. We have analyzed its performance and convergence extensively through simulations and cross-correlations of the deconvolved images with available high-resolution maps. We present new science results from two BLAST surveys, in the Galactic regions K3-50 and IC 5146, further demonstrating the benefits of performing this deconvolution. We have resolved three clumps within a radius of 4.'5 inside the star-forming molecular cloud containing K3-50. Combining the well-resolved dust emission map with available multi-wavelength data, we have constrained the spectral energy distributions (SEDs) of five clumps to obtain masses (M), bolometric luminosities (L), and dust temperatures (T). The L-M diagram has been used as a diagnostic tool to estimate the evolutionary stages of the clumps. There are close relationships between dust continuum emission and both 21 cm radio continuum and {sup 12}CO molecular line emission. The restored extended large-scale structures in the Northern Streamer of IC 5146 have a strong spatial correlation with both SCUBA and high-resolution extinction images. A dust temperature of 12 K has been obtained for the central filament. We report physical properties of ten compact sources, including six associated protostars, by fitting SEDs to multi-wavelength data. All of these compact sources are still quite cold (typical temperature below {approx} 16 K) and are above the critical Bonner-Ebert mass. They have associated low-power young stellar objects. Further evidence for starless clumps has also been found in the IC 5146 region.

79 ASTRONOMY AND ASTROPHYSICS↗

Advanced Background Subtraction Applied to Aeroacoustic Wind Tunnel Testing

An advanced form of background subtraction is presented and applied to aeroacoustic wind tunnel data. A variant of this method has seen use in other fields such as climatology and medical imaging. The technique, based on an eigenvalue decomposition of the background noise cross-spectral matrix, is robust against situations where isolated background auto-spectral levels are measured to be higher than levels of combined source and background signals. It also provides an alternate estimate of the cross-spectrum, which previously might have poor definition for low signal-to-noise ratio measurements. Simulated results indicate similar performance to conventional background subtraction when the subtracted spectra are weaker than the true contaminating background levels. Superior performance is observed when the subtracted spectra are stronger than the true contaminating background levels. Experimental results show limited success in recovering signal behavior for data where conventional background subtraction fails. They also demonstrate the new subtraction technique's ability to maintain a proper coherence relationship in the modified cross-spectral matrix. Beam-forming and de-convolution results indicate the method can successfully separate sources. Results also show a reduced need for the use of diagonal removal in phased array processing, at least for the limited data sets considered.

Bahr, Christopher J.↗

New results and techniques in space radio astronomy.

The methods and results of early space radioastronomy experiments are reviewed, with emphasis on the RAE 1 spacecraft which was designed specifically and exclusively for radio astronomical studies. The RAE 1 carries two gravity-gradient-stabilized 229-m traveling-wave V-antennas, a 37-m dipole antenna, and a number of radiometer systems to provide measurements over the 0.2 to 9.2 MHz frequency range with a time resolution of 0.5 sec and an absolute accuracy of plus or minus 25%. Observations of solar bursts at frequencies down to 0.2 MHz provide new information on the density, plasma velocity, and dynamics of coronal streamers out to distances greater than 50 solar radii. New information on the distribution of the ionized component of the interstellar medium is being obtained from galactic continuum background maps at frequencies around 4 MHz. Cosmic noise background spectra measured down to 0.5 MHz produce new estimates on the interstellar flux of cosmic rays, on magnetic fields in the galactic halo, and on distant extragalactic radio sources.

Alexander, J. K.↗

Thunderstorms observed by radio astronomy Explorer 1 over regions of low man made noise

Radio Astronomy Explorer (RAE) I observations of thunderstorms over regions of low man-made noise levels are analyzed to assess the satellite's capability for noise source differentiation. The investigation of storms over Australia indicates that RAE can resolve noise generation due to thunderstorms from the general noise background over areas of low man-made noise activity. Noise temperatures observed by RAE over stormy regions are on the average 10DB higher than noise temperatures over the same regions in the absence of thunderstorms. In order to determine the extent of noise contamination due to distant transmitters comprehensive three dimensional computer ray tracings were generated. The results indicate that generally, distant transmitters contribute negligibly to the total noise power, being 30DB or more below contributions arriving from an area immediately below the satellite.

Caruso, J. A.↗

Guide to the evaluation of human exposure to noise from large wind turbines

Guidance for evaluating human exposure to wind turbine noise is provided and includes consideration of the source characteristics, the propagation to the receiver location, and the exposure of the receiver to the noise. The criteria for evaluation of human exposure are based on comparisons of the noise at the receiver location with the human perception thresholds for wind turbine noise and noise-induced building vibrations in the presence of background noise.

Stephens, D. G.↗

Autonomously Calibrating a Quadrupole Mass Spectrometer

A computer program autonomously manages the calibration of a quadrupole ion mass spectrometer intended for use in monitoring concentrations and changes in concentrations of organic chemicals in the cabin air of the International Space Station. The instrument parameters calibrated include the voltage on a channel electron multiplier, a discriminator threshold, and an ionizer current. Calibration is achieved by analyzing the mass spectrum obtained while sweeping the parameter ranges in a heuristic procedure, developed by mass spectrometer experts, that involves detection of changes in signal trends that humans can easily recognize but cannot necessarily be straightforwardly codified in an algorithm. The procedure includes calculation of signal-to-noise ratios, signal-increase rates, and background-noise-increase rates; finding signal peaks; and identifying peak patterns. The software provides for several recovery-from-error scenarios and error-handling schemes. The software detects trace amounts of contaminant gases in the mass spectrometer and notifies associated command- and-data-handling software to schedule a cleaning. Furthermore, the software autonomously analyzes the mass spectrum to determine whether the parameters of a radio-frequency ramp waveform are set properly so that the peaks of the mass spectrum are at expected locations.

Lee, Seungwon↗

Frame-Transfer Gating Raman Spectroscopy for Time-Resolved Multiscalar Combustion Diagnostics

Accurate experimental measurement of spatially and temporally resolved variations in chemical composition (species concentrations) and temperature in turbulent flames is vital for characterizing the complex phenomena occurring in most practical combustion systems. These diagnostic measurements are called multiscalar because they are capable of acquiring multiple scalar quantities simultaneously. Multiscalar diagnostics also play a critical role in the area of computational code validation. In order to improve the design of combustion devices, computational codes for modeling turbulent combustion are often used to speed up and optimize the development process. The experimental validation of these codes is a critical step in accepting their predictions for engine performance in the absence of cost-prohibitive testing. One of the most critical aspects of setting up a time-resolved stimulated Raman scattering (SRS) diagnostic system is the temporal optical gating scheme. A short optical gate is necessary in order for weak SRS signals to be detected with a good signal- to-noise ratio (SNR) in the presence of strong background optical emissions. This time-synchronized optical gating is a classical problem even to other spectroscopic techniques such as laser-induced fluorescence (LIF) or laser-induced breakdown spectroscopy (LIBS). Traditionally, experimenters have had basically two options for gating: (1) an electronic means of gating using an image intensifier before the charge-coupled-device (CCD), or (2) a mechanical optical shutter (a rotary chopper/mechanical shutter combination). A new diagnostic technology has been developed at the NASA Glenn Research Center that utilizes a frame-transfer CCD sensor, in conjunction with a pulsed laser and multiplex optical fiber collection, to realize time-resolved Raman spectroscopy of turbulent flames that is free from optical background noise (interference). The technology permits not only shorter temporal optical gating (down to <1 s, in principle), but also higher optical throughput, thus resulting in a substantial increase in measurement SNR.

Nguyen, Quang-Viet↗

Apparatus for reducing aerodynamic noise in a wind tunnel

An apparatus is described for reducing the background noise produced by the porous walls of the test section of a wind tunnel. A finely meshed screen member is placed over the perforations in the test section walls. The mesh wire screen attached to the interior wall provides a smoother surface for the air stream to flow against reducing the vorticies produced by the edges of the perforations in the test section walls.

Howard, P. W.↗

Sensitivity of ultralight axion dark matter search with optical quantum sensors

An optical quantum sensor (OQS) based on lasers and alkali-metal atoms is a sensitive ambient-temperature magnetometer that can be used in axion dark matter search with an inductor-capacitor (LC) circuit at kHz and MHz frequencies. We have previously investigated the sensitivity of an LC circuit-OQS axion detector to ultralight axion dark matter that could be achieved using a fT-noise OQS constructed in our lab. In this paper, we investigate the sensitivity that could be potentially reached by an OQS performing close to the fundamental quantum noise levels of 10 aT / $\sqrt{Hz}$. To take advantage of the quantum-limited OQS, the LC circuit has to be made of a superconductor and cooled to low temperature of a few K. After considering the intrinsic noise of the advanced axion detector and characterizing possible background noises, we estimate that such an experiment could probe benchmark QCD axion models in an unexplored mass range near 10 neV. Reaching such a high sensitivity is a difficult task, so we have conducted some preliminary experiments with a large-bore magnet and a prototype axion detector consisting of a room-temperature LC circuit and a commercial OQS unit. In conclusion, this paper describes the prototype experiment and its projected sensitivity to axions in detail.

79 ASTRONOMY AND ASTROPHYSICS↗

The recognition of extraterrestrial artificial signals

Considerations in the design of receivers for the detection and recognition of artificial microwave signals of extraterrestrial origin are discussed. Following a review of the objectives of SETI and the probable reception and detection characteristics of extraterrestrial signals, means for the improvement of the sensitivity, signal-to-noise ratios and on-line data processing capabilities of SETI receivers are indicated. The characteristics of the signals likely to be present at the output of an ultra-low-noise microwave receiver are then examined, including the system background noise, terrestrial radiations, astrophysical radiations, accidental artificial radiations of terrestrial origin, and intentional radiations produced by humans and by extraterrestrial intelligence. The classes of extraterrestrial signals likely to be detected, beacons and leakage signals, are considered, and options in the specification of gating and thresholding for a high-spectral resolution, high-time-resolution signal discriminator are indicated. Possible tests for the nonhuman origin of a received signal are also pointed out.

Seeger, C. L.↗

Large scale model measurements of airframe noise using cross-correlation techniques

Cross-correlation techniques are used to measure the sound radiated by wing/flap airfoil configurations in the NASA-Ames 40 x 80 ft wind tunnel using a 6.7-m semispan model with three deployed flaps. The dominant source of flap noise is identified as the flap side edges, which exceeds that radiated by the midspan region by more than 10 dB. The turbulent surface eddies at the flap side edge have scales on the order of one-half the flap chord. The installation of flap actuator fairings at the flap side edge reduces the noise radiated from that location by 10 to 15 dB. The cross-correlation technique extracts airframe noise radiated by specific surface locations from the tunnel background noise, even when the noise is 25 dB higher than the measured airframe noise level.

Miller, W. R.↗

Combining visible and infrared techniques with LAMMR for daily rainfall estimates

A brief description of other methods of rainfall measurement at the sea surface is given. The general underwater ambient noise background of the ocean is described. The physics of noise generation by bubbles and splashes is reviewed. Monitoring underwater ambient noise levels to measure rainfall rate requires that the spectral shapes of the noise from wind and rain be different or at least distinguishable. This would allow the rain noise to be separated from the wind noise and then hopefully it can be correlated with rainfall rate. Different spectral shapes are observed experimentally.

Lovejoy, S.↗

Daytime adaptive optics for deep space optical communications

The deep space optical communications subsystem offers a higher bandwidth communications link in smaller size, lower mass, and lower power consumption subsystem than does RF. To demonstrate the benefit of this technology to deep space communications NASA plans to launch an optical telecommunications package on the 2009 Mars Telecommunications orbiter spacecraft. Current performance goals are 30-Mbps from opposition, and 1-Mbps near conjunction (-3 degrees Sun-Earth-Probe angle). Yet, near conjunction the background noise from the day sky will degrade the performance of the optical link. Spectral and spatial filtering and higher modulation formats can mitigate the effects of background sky. Narrowband spectral filters can result in loss of link margin, and higher modulation formats require higher transmitted peak powers. In contrast, spatial filtering at the receiver has the potential of being lossless while providing the required sky background rejection. Adaptive optics techniques can correct wave front aberrations caused by atmospheric turbulence and enable near-diffraction-limited performance of the receiving telescope. Such performance facilitates spatial filtering, and allows the receiver field-of-view and hence the noise from the sky background to be reduced.

adaptive optics↗

An Algorithm for Enhancing the Image Contrast of Electron Tomography

Abstract Three-dimensional (3D) reconstruction of a single protein molecule is essential for understanding the relationship between the structural dynamics and functions of the protein. Electron tomography (ET) provides a tool for imaging an individual particle of protein from a series of tilted angles. Individual-particle electron tomography (IPET) provides an approach for reconstructing a 3D density map from a single targeted protein particle (without averaging from different particles of this type of protein), in which the target particle was imaged from a series of tilting angles. However, owing to radiation damage limitations, low-dose images (high noise, and low image contrast) are often challenging to be aligned for 3D reconstruction at intermediate resolution (1–3 nm). Here, we propose a computational method to enhance the image contrast, without increasing any experimental dose, for IPET 3D reconstruction. Using an edge-preserving smoothing-based multi-scale image decomposition algorithm, this method can detect the object against a high-noise background and enhance the object image contrast without increasing the noise level or significantly decreasing the image resolution. The method was validated by using both negative staining (NS) ET and cryo-ET images. The successful 3D reconstruction of a small molecule (<100 kDa) indicated that this method can be used as a supporting tool to current ET 3D reconstruction methods for studying protein dynamics via structure determination from each individual particle of the same type of protein.

47 OTHER INSTRUMENTATION↗

Constraining neutrino-nucleon form factors with charged-current scattering at the Electron-Ion Collider

Next-generation neutrino oscillation experiments such as the Deep Underground Neutrino Experiment require percent-level knowledge of neutrino-nucleon interaction cross sections. The nucleon axial form factor 𝐹 𝐴 ⁡(𝑄 2 ), parametrized by the axial mass 𝑀 𝐴 , is the dominant source of uncertainty in the quasielastic channel, and the parity-violating structure function 𝑥⁢𝐹 3 is poorly constrained on free nucleons. We propose using charged-current (CC) electron-proton scattering at the Electron-Ion Collider (EIC) to address both problems simultaneously. The measurement exploits three key features of the EIC: (1) helicity-selective electron bunches provide in situ electromagnetic background rejection; (2) a longitudinally polarized proton target enables extraction of 𝐹 𝐴 ⁡(𝑄 2 ) through the target-spin asymmetry 𝐴 𝑈⁢𝐿 ; and (3) the 𝑦-distribution leverage in CC deep inelastic scattering (DIS) separates 𝐹 2 and 𝑥⁢𝐹 3 on a free proton, without nuclear corrections. Using a Fisher information analysis at $\sqrt{𝑠}$ =141 GeV with 500 fb −1 of integrated luminosity, we project the Cramér-Rao statistical floor of 𝛿⁢𝑀 𝐴 ≈0.03 GeV (3%). Incorporating first-order realistic detector effects, such as zero-degree calorimeter acceptance, 𝑄 2 smearing (5%), and background noise from helicity subtraction, the projected sensitivity is severely background-limited due to the small signal-to-background ratio (𝑆/𝐵 ≈ 3 ×10 −4 ) in the elastic channel. Achieving competitive sensitivity (𝛿⁢𝑀 𝐴 ≈ 0.14 GeV) would require ∼10 −7 background suppression, 3 orders of magnitude beyond current projections. The CC DIS 𝑦 distribution provides subpercent extraction of 𝑥⁢𝐹$^{𝑊^{−}}_{3}$ over 0.05 < 𝑥 < 0.5, representing the most robust electroweak measurement in the near term.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗