Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Average Accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Automated thematic mapping and change detection of ERTS-A images

The author has identified the following significant results. In the first part of the investigation, spatial and spectral features were developed which were employed to automatically recognize terrain features through a clustering algorithm. In this part of the investigation, the size of the cell which is the number of digital picture elements used for computing the spatial and spectral features was varied. It was determined that the accuracy of terrain recognition decreases slowly as the cell size is reduced and coincides with increased cluster diffuseness. It was also proven that a cell size of 17 x 17 pixels when used with the clustering algorithm results in high recognition rates for major terrain classes. ERTS-1 data from five diverse geographic regions of the United States were processed through the clustering algorithm with 17 x 17 pixel cells. Simple land use maps were produced and the average terrain recognition accuracy was 82 percent.

Gramenopoulos, N.↗

AutonomieAI: An efficient and deployable vehicle energy consumption estimation toolkit

Here, this paper presents AutonomieAI, a novel toolkit designed for efficient energy estimation of vehicles across diverse trip scenarios, routes, and drive cycles, applicable to a broad range of vehicle powertrain technologies. It leverages state-of-the-art Machine Learning techniques to deliver real-time energy prediction of vehicles, enabling co-simulation with transportation level system tools and opening doors for large-scale optimization at city, network or national level. Benchmark results show that AutonomieAI achieves high accuracy, with an average percentage error below 2% for most powertrain types, and computational efficiency capable of processing over 10,000 trips per second. Applications of AutonomieAI have potential to offer the flexibility to assist in solving eco-routing problems, optimize for vehicle and powertrain selection, study charging decision behavior, and optimize for charging station placement. AutonomieAI is the result of large neural network based model architectures, trained on very large and unique high fidelity vehicle simulation data. It is lightweight, deployable, efficient and has accuracy comparable to specialized and complex physics based simulation softwares.

Autonomie↗

Relative Accuracy Assessment of LANDSAT-4 MSS and TM Data for Level 1 Land Cover Inventory

Digital data for the Washington, D.C. scene from the LANDSAT-4 Multispectral Scanner (MSS) and the LANDSAT-4 Thematic Mapper (TM) are compared. Classification success for the TM and MSS data sets was determined by a per pixel comparison with digitized ground verification data (GVD). These GVD were comprised of Level I land cover (developed, agriculture, forest, water, wetlands, and barren) for four USGS 7.5-minute topographic quadrangle maps. Classification accuracy was computed as an average value and for each cover type. Accuracy was expressed two ways: (1) as the percent correspondence with GVD (% correct) and (2) as the percent correspondence relative to both the GVD and LANDSAT classification schemes. Errors of omission and commission associated with the LANDSAT classifications were also computed. Specific results are discussed.

Middleton, E. M.↗

SU-E-T-453: A Novel Daily QA System for Robotic Image Guided Radiosurgery with Variable Aperture Collimator

Purpose: A novel end-to-end system using a CCD camera and a scintillator based phantom that is capable of measuring the beam-by-beam delivery accuracy of Robotic Radiosurgery has been developed and reported in our previous work. This work investigates its application to end-to-end type daily QA for Robotic Radiosurgery (Cyberknife) with Variable Aperture Collimator (Iris). Methods: The phantom was first scanned with a CT scanner at 0.625 slice thickness and exported to the Cyberknife Muliplan (v4.6) treatment planning system. An isocentric treatment plan was created consisting of ten beams of 25 Monitor Units each using Iris apertures of 7.5, 10, 15, 20, and 25 mm. The plan was delivered six times in two days on the Cyberknife G4 system with fiducial tracking on the four metal fiducials embedded in phantom with re-positioning between the measurements. The beam vectors (X, Y, Z) are measured and compared with the plan from the machine delivery file (XML file). The Iris apertures (FWHM) were measured from the beam flux map and compared with the commissioning data. Results: The average beam positioning accuracies of the six deliveries are 0.71 ± 0.40 mm, 0.72 ± 0.44 mm, 0.74 ± 0.42 mm, 0.70 ± 0.40 mm, 0.79 ± 0.44 mm and 0.69 ± 0.41 mm respectively. Radiation beam width (FWHM) variations are within ±0.05 mm, and they agree with the commissioning data within 0.22 mm. The delivery time for the plan is about 7 minutes and the results are given instantly. Conclusion: The experimental results agree with stated sub-millimeter delivery accuracy of Cyberknife system. Beam FWHM variations comply with the 0.2 mm accuracy of the Iris collimator at SAD. The XRV-100 system has proven to be a powerful tool in performing end-to-end type tests for Robotic Image Guided Radiosurgery Daily QA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving Prediction of Peroxide Value of Edible Oils Using Regularized Regression Models

We present four unique prediction techniques, combined with multiple data pre-processing methods, utilizing a wide range of both oil types and oil peroxide values (PV) as well as incorporating natural aging for peroxide creation. Samples were PV assayed using a standard starch titration method, AOCS Method Cd 8-53, and used as a verified reference method for PV determination. Near-infrared (NIR) spectra were collected from each sample in two unique optical pathlengths (OPLs), 2 and 24 mm, then fused into a third distinct set. All three sets were used in partial least squares (PLS) regression, ridge regression, LASSO regression, and elastic net regression model calculation. While no individual regression model was established as the best, global models for each regression type and pre-processing method show good agreement between all regression types when performed in their optimal scenarios. Furthermore, small spectral window size boxcar averaging shows prediction accuracy improvements for edible oil PVs. Best-performing models for each regression type are: PLS regression, 25 point boxcar window fused OPL spectral information RMSEP = 2.50; ridge regression, 5 point boxcar window, 24 mm OPL, RMSEP = 2.20; LASSO raw spectral information, 24 mm OPL, RMSEP = 1.80; and elastic net, 10 point boxcar window, 24 mm OPL, RMSEP = 1.91. The results show promising advancements in the development of a full global model for PV determination of edible oils.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fair Concurrent Training of Multiple Models in Federated Learning

Federated learning (FL) enables collaborative learning across multiple clients. In most FL work, all clients train a single learning task. However, the recent proliferation of FL applications may increasingly require multiple FL tasks to be trained simultaneously, sharing clients’ computing resources, which we call Multiple-Model Federated Learning (MMFL). Current MMFL algorithms use naïve average-based client-task allocation schemes that often lead to unfair performance when FL tasks have heterogeneous difficulty levels, as the more difficult tasks may need more client participation to train effectively. Furthermore, in the MMFL setting, we face a further challenge that some clients may prefer training specific tasks to others, and may not even be willing to train other tasks, e.g., due to high computational costs, which may exacerbate unfairness in training outcomes across tasks. We address both challenges by firstly designing FedFairMMFL, a difficulty-aware algorithm that dynamically allocates clients to tasks in each training round, based on the tasks’ current performance levels. We provide guarantees on the resulting task fairness and FedFairMMFL’s convergence rate. We then propose novel auction designs that incentivizes clients to train multiple tasks, so as to fairly distribute clients’ training efforts across the tasks, and extend our convergence guarantees to this setting. Here, we finally evaluate our algorithm with multiple sets of learning tasks on real world datasets, showing that our algorithm improves fairness by improving the final model accuracy and convergence speed of the worst performing tasks, while maintaining the average accuracy across tasks.

Federated learning↗

A hybrid reconstruction algorithm for fast and accurate 4D cone-beam CT imaging

Purpose: 4D cone beam CT (4D-CBCT) has been utilized in radiation therapy to provide 4D image guidance in lung and upper abdomen area. However, clinical application of 4D-CBCT is currently limited due to the long scan time and low image quality. The purpose of this paper is to develop a new 4D-CBCT reconstruction method that restores volumetric images based on the 1-min scan data acquired with a standard 3D-CBCT protocol. Methods: The model optimizes a deformation vector field that deforms a patient-specific planning CT (p-CT), so that the calculated 4D-CBCT projections match measurements. A forward-backward splitting (FBS) method is invented to solve the optimization problem. It splits the original problem into two well-studied subproblems, i.e., image reconstruction and deformable image registration. By iteratively solving the two subproblems, FBS gradually yields correct deformation information, while maintaining high image quality. The whole workflow is implemented on a graphic-processing-unit to improve efficiency. Comprehensive evaluations have been conducted on a moving phantom and three real patient cases regarding the accuracy and quality of the reconstructed images, as well as the algorithm robustness and efficiency. Results: The proposed algorithm reconstructs 4D-CBCT images from highly under-sampled projection data acquired with 1-min scans. Regarding the anatomical structure location accuracy, 0.204 mm average differences and 0.484 mm maximum difference are found for the phantom case, and the maximum differences of 0.3–0.5 mm for patients 1–3 are observed. As for the image quality, intensity errors below 5 and 20 HU compared to the planning CT are achieved for the phantom and the patient cases, respectively. Signal-noise-ratio values are improved by 12.74 and 5.12 times compared to results from FDK algorithm using the 1-min data and 4-min data, respectively. The computation time of the algorithm on a NVIDIA GTX590 card is 1–1.5 min per phase. Conclusions: High-quality 4D-CBCT imaging based on the clinically standard 1-min 3D CBCT scanning protocol is feasible via the proposed hybrid reconstruction algorithm.

60 APPLIED LIFE SCIENCES↗

Improved frame-based estimation of head motion in PET brain imaging

Purpose: Head motion during PET brain imaging can cause significant degradation of image quality. Several authors have proposed ways to compensate for PET brain motion to restore image quality and improve quantitation. Head restraints can reduce movement but are unreliable; thus the need for alternative strategies such as data-driven motion estimation or external motion tracking. Herein, the authors present a data-driven motion estimation method using a preprocessing technique that allows the usage of very short duration frames, thus reducing the intraframe motion problem commonly observed in the multiple frame acquisition method. Methods: The list mode data for PET acquisition is uniformly divided into 5-s frames and images are reconstructed without attenuation correction. Interframe motion is estimated using a 3D multiresolution registration algorithm and subsequently compensated for. For this study, the authors used 8 PET brain studies that used F-18 FDG as the tracer and contained minor or no initial motion. After reconstruction and prior to motion estimation, known motion was introduced to each frame to simulate head motion during a PET acquisition. To investigate the trade-off in motion estimation and compensation with respect to frames of different length, the authors summed 5-s frames accordingly to produce 10 and 60 s frames. Summed images generated from the motion-compensated reconstructed frames were then compared to the original PET image reconstruction without motion compensation. Results: The authors found that our method is able to compensate for both gradual and step-like motions using frame times as short as 5 s with a spatial accuracy of 0.2 mm on average. Complex volunteer motion involving all six degrees of freedom was estimated with lower accuracy (0.3 mm on average) than the other types investigated. Preprocessing of 5-s images was necessary for successful image registration. Since their method utilizes nonattenuation corrected frames, it is not susceptible to motion introduced between CT and PET acquisitions. Conclusions: The authors have shown that they can estimate motion for frames with time intervals as short as 5 s using nonattenuation corrected reconstructed FDG PET brain images. Intraframe motion in 60-s frames causes degradation of accuracy to about 2 mm based on the motion type.

60 APPLIED LIFE SCIENCES↗

Real-Time Target Position Estimation Using Stereoscopic Kilovoltage/Megavoltage Imaging and External Respiratory Monitoring for Dynamic Multileaf Collimator Tracking

Purpose: To develop a real-time target position estimation method using stereoscopic kilovoltage (kV)/megavoltage (MV) imaging and external respiratory monitoring, and to investigate the performance of a dynamic multileaf collimator tracking system using this method. Methods and Materials: The real-time three-dimensional internal target position estimation was established by creating a time-varying correlation model that connected the external respiratory signals with the internal target motion measured intermittently using kV/MV imaging. The method was integrated into a dynamic multileaf collimator tracking system. Tracking experiments were performed for 10 thoracic/abdominal traces. A three-dimensional motion platform carrying a gold marker and a separate one-dimensional motion platform were used to reproduce the target and external respiratory motion, respectively. The target positions were detected by kV (1 Hz) and MV (5.2 Hz) imaging, and external respiratory motion was captured by an optical system (30 Hz). The beam-target alignment error was quantified as the positional difference between the target and circular beam center on the MV images acquired during tracking. The correlation model error was quantified by comparing a model estimate and measured target positions. Results: The root-mean-square errors in the beam-target alignment that had ranged from 3.1 to 7.6 mm without tracking were reduced to <1.5 mm with tracking, except during the model building period (6 s). The root-mean-square error in the correlation model was submillimeters in all directions. Conclusion: A novel real-time target position estimation method was developed and integrated into a dynamic multileaf collimator tracking system and demonstrated an average submillimeter geometric accuracy after initializing the internal/external correlation model. The method used hardware tools available on linear accelerators and therefore shows promise for clinical implementation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Protein structure prediction guided by crosslinking restraints – A systematic evaluation of the impact of the crosslinking spacer length

Recent development of high-resolution mass spectrometry (MS) instruments enables chemical crosslinking (XL) to become a high-throughput method for obtaining structural information about proteins. Restraints derived from XL-MS experiments have been used successfully for structure refinement and protein–protein docking. However, one formidable question is under which circumstances XL-MS data might be sufficient to determine a protein’s tertiary structure de novo? Answering this question will not only include understanding the impact of XL-MS data on sampling and scoring within a de novo protein structure prediction algorithm, it must also determine an optimal crosslinker type and length for protein structure determination. While a longer crosslinker will yield more restraints, the value of each restraint for protein structure prediction decreases as the restraint is consistent with a larger conformational space. In this study, the number of crosslinks and their discriminative power was systematically analyzed in silico on a set of 2055 non-redundant protein folds considering Lys–Lys, Lys–Asp, Lys–Glu, Cys–Cys, and Arg–Arg reactive crosslinkers between 1 and 60 Å. Depending on the protein size a heuristic was developed that determines the optimal crosslinker length. Next, simulated restraints of variable length were used to de novo predict the tertiary structure of fifteen proteins using the BCL::Fold algorithm. The results demonstrate that a distinct crosslinker length exists for which information content for de novo protein structure prediction is maximized. The sampling accuracy improves on average by 1.0 Å and up to 2.2 Å in the most prominent example. XL-MS restraints enable consistently an improved selection of native-like models with an average enrichment of 2.1.

Biochemistry & Molecular Biology↗

Data-Driven Kinetic Reaction Networks for Separation Chemistry

Understanding complex, multistep chemical reactions at the molecular level is a major challenge whose solution would greatly benefit the design and optimization of numerous chemical processes. The separation of rare-earth (4f) and actinide (5f) elements is an example where improving our chemical understanding is important for designing and optimizing new chemistries, even with a limited number of observations. Here, in this work, we leverage data-driven artificial intelligence and machine-learning approaches to develop kinetic reaction networks that describe the liquid–liquid extraction mechanism of uranium using N,N-di-2-ethylhexyl-isobutyramide (DEHiBA). Specifically, we compare and contrast the properties of two classes of models: (1) purely data-driven models that are regularized using chemistry-agnostic, L1 regression and (2) chemistry-informed models that are regularized using relative reaction energies provided by quantum mechanical calculations. We observe that purely data-driven models are unbiased, simple, and accurate in their predictions of experimental measurements when provided with sufficient data but are difficult to fully constrain and interpret. In contrast, chemistry-informed models exhibit significantly improved chemical interpretability and consistency, providing a detailed description of the separation process while achieving high accuracy through ensemble averaging. Overall, the dominant species predicted to be extracted into the organic phase is UO 2 (NO 3 ) 2 (DEHiBA) 2 , agreeing with experimental slope analysis, thermodynamic modeling, EXAFS, and crystal structures. This work demonstrates that leveraging the fundamental structure of the problem can lead to efficient learning schemes that provide both accurate predictions and chemical insights at a low computational cost.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deep learning of electrochemical CO 2 conversion literature reveals research trends and directions

Large-scale and openly available material science databases are mainly composed of computer simulation results rather than experimental data. Some examples include the Materials Project, Open Quantum Materials Database, and Open Catalyst 2022. Unfortunately, building large-scale experimental databases remains challenging due to the difficulties in consolidating locally distributed datasets. In this work, focusing on the catalysis literature of CO 2 reduction reactions (CO 2 RRs), we present a machine learning (ML)-based protocol for selecting highly relevant papers and extracting important experimental data. First, we report a document embedding method (Doc2Vec) for collecting papers of greatest relevance to the specific target domain, which yielded 3154 CO 2 RR-related papers from six publishers. Next, we developed named entity recognition (NER) models to extract twelve entities related to material names (catalyst, electrolyte, etc.) and catalytic performance (Faradaic efficiency, current density, etc.). Further, among several tested models, the MatBERT-based approach achieved the highest accuracy, with an average F1-score of 90.4% and an F1-score of 95.2% in a boundary relaxation evaluation scheme. The accurate and accelerated NER-based data extraction from a large volume of catalysis literature enables temporal trend analyses of the CO 2 RR catalysts, products, and performances, revealing the potentially effective material space in CO 2 RRs. While this work demonstrates the effectiveness of our ML-based text mining methods for specifically CO 2 RR literature, the methods and approach are applicable to and may be used to accelerate the development of other catalytic chemical reactions.

36 MATERIALS SCIENCE↗

Rotational excitations in rare-earth nuclei: A comparative study within three cranking models with different mean fields and treatments of pairing correlations

High-spin rotational bands in rare-earth Er (Z = 68), Tm (Z = 69), and Yb (Z = 70) isotopes are investigated by three different nuclear models. These are (i) the cranked relativistic Hartree-Bogoliubov (CRHB) approach with approximate particle number projection by means of the Lipkin-Nogami (LN) method, (ii) the cranking covariant density functional theory (CDFT) with pairing correlations treated by a shell-model-like approach (SLAP) or the so-called particle-number conserving (PNC) method, and (iii) cranked shell model (CSM) based on the Nilsson potential with pairing correlations treated by the PNC method. A detailed comparison between these three models in the description of the ground-state rotational bands of even-even Er and Yb isotopes is performed. The similarities and differences between these models in the description of the moments of inertia, the features of band crossings, and equilibrium deformations and pairing energies of the even-even nuclei under study are discussed. These quantities are considered as a function of rotational frequency and proton and neutron numbers. The changes in the properties of the first band crossings with increasing neutron number in this mass region are investigated. On average, a comparable accuracy of the description of available experimental data is achieved in these models. However, the differences between model predictions become larger above the first band crossings. Because of the time-consuming nature of numerical calculations in the CDFT-based models, a systematic study of the rotational properties of both ground-state and excited-state bands in odd-mass Tm nuclei is carried out only by the PNC-SCM. With few exceptions, the rotational properties of experimental 1-quasiparticle and 3-quasiparticle bands in 165,167,169,171 Tm are reproduced reasonably well. As a result, the appearance of backbendings or upbendings in these nuclei is well understood from the analysis of the variations of the occupation probabilities of the single-particle states and their contributions to total angular momentum alignment with rotational frequency.

150 ≤ A ≤ 189↗

Ultra-Short-Term Spatiotemporal Forecasting of Renewable Resources: An Attention Temporal Convolutional Network Based Approach

The rapid increase in the penetration of renewable energy resources characterized by high variability and uncertainty is bringing new challenges to the power system operation. To ensure the efficient and reliable operation of electric grid, an accurate and general short-term forecasting algorithm with interpretability is desired. Moreover, the extensive off-site information provided by the proliferation of new renewable plants stimulates the interests in the spatiotemporal forecasting. In this paper, an attention temporal convolutional network, which is built on stacked dilated causal convolutional networks and attention mechanisms, is proposed to perform the ultra-short-term spatiotemporal forecasting of renewable resources. Compared with the existing spatiotemporal forecasting methods, the presented model needs no domain knowledge and can be applied to different forecasting tasks such as solar generation and wind speed forecasting. Here, the attention mechanism improves the interpretability. The algorithm can be used to produce both point and probabilistic forecasts. Numerical results on the data sets from National Renewable Energy Laboratory show superior performance over five baselines, in terms of skill scores. Compared with the baselines, the average improvements of accuracy introduced by the proposed method for the point and probabilistic forecasting are 15.08% and 15.85%, respectively.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Characterization and differentiation of aluminum powders used in improvised explosive devices. Part 2: Micromorphometric method refinement and preliminary statistical analysis

Abstract Aluminum (Al) powder is commonly encountered in improvised explosive devices (IEDs) as a metallic fuel due to its availability and low cost. Although available commercially in powder form, amateur bomb‐makers also produce their own Al powder via simple methods found online. In order to provide investigative leads and forensic intelligence, it is important to evaluate not only the composition of homemade devices, but also to distinguish between the various forms of Al powder they contain. To achieve this goal, a method using automated microscopy in combination with statistical techniques has been demonstrated to have the potential to provide source discrimination and investigative leads in source attribution of Al powders in IEDs. The present research refined this method and investigated 59 industrially and amateurly produced Al powder sources with seven subsamples per source using two traditional linear discriminant analyses (LDA), one with a standard data split for training and testing, and another using leave‐one‐out cross‐validation. Averaging the classification accuracies for the two LDA‐based analyses, LDA has the ability to correctly classify 59.26%, 83.35%, and 80.69% of the samples based on their powder source, type, and production method, respectively. This classification accuracy represents a 3407%, 317%, and 61.38% increase in accuracy from random class assignment, respectively. Further, in most instances of incorrect data attribution to a particular source, the subsample has been misidentified with another sample of the same powder type or production method.

Ommen, Danica M.↗

Fast, accurate, and robust automatic marker detection for motion correction based on oblique kV or MV projection image pairs

Purpose: A robust and accurate method that allows the automatic detection of fiducial markers in MV and kV projection image pairs is proposed. The method allows to automatically correct for inter or intrafraction motion. Methods: Intratreatment MV projection images are acquired during each of five treatment beams of prostate cancer patients with four implanted fiducial markers. The projection images are first preprocessed using a series of marker enhancing filters. 2D candidate marker locations are generated for each of the filtered projection images and 3D candidate marker locations are reconstructed by pairing candidates in subsequent projection images. The correct marker positions are retrieved in 3D by the minimization of a cost function that combines 2D image intensity and 3D geometric or shape information for the entire marker configuration simultaneously. This optimization problem is solved using dynamic programming such that the globally optimal configuration for all markers is always found. Translational interfraction and intrafraction prostate motion and the required patient repositioning is assessed from the position of the centroid of the detected markers in different MV image pairs. The method was validated on a phantom using CT as ground-truth and on clinical data sets of 16 patients using manual marker annotations as ground-truth. Results: The entire setup was confirmed to be accurate to around 1 mm by the phantom measurements. The reproducibility of the manual marker selection was less than 3.5 pixels in the MV images. In patient images, markers were correctly identified in at least 99% of the cases for anterior projection images and 96% of the cases for oblique projection images. The average marker detection accuracy was 1.4{+-}1.8 pixels in the projection images. The centroid of all four reconstructed marker positions in 3D was positioned within 2 mm of the ground-truth position in 99.73% of all cases. Detecting four markers in a pair of MV images takes a little less than a second where most time is spent on the image preprocessing. Conclusions: The authors have developed a method to automatically detect multiple markers in a pair of projection images that is robust, accurate, and sufficiently fast for clinical use. It can be used for kV, MV, or mixed image pairs and can cope with limited motion between the projection images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An iterative method for tomographic x-ray perfusion estimation in a decomposition model-based approach

Purpose: X-ray based tomographic blood perfusion imaging requires recovery of contrast time-attenuation-curves from dynamic projection data. When using slowly rotating imaging systems, this task is challenging due to nonsimultaneous projection acquisition. A dynamic reconstruction method is proposed that aims at compensating the lack of simultaneously acquired information by incorporating prior knowledge about the expected temporal contrast dynamics. Methods: A decomposition model using temporal basis functions to approximate time-attenuation-curves is integrated into an iterative tomographic reconstruction method. The computationally efficient implementation of the proposed approach makes use of standard forward-projections and backprojections, as well as scalar products in image space. The critical issue of projection noise propagation is tackled by the application of regularization which is realized by the early stopping of iteration cycles and by the proper selection of smooth temporal basis functions. The performance of the proposed dynamic reconstruction approach is evaluated in a simulation study concerning various aspects: Noise propagation and regularization, specification of the temporal model, and type of acquisition mode. Results: The evaluation based on dynamic phantom data indicates that tomographic recovery of contrast time-attenuation-curves in tissue can be achieved with an average range of accuracy of {approx}2% (with respect to dynamic peak attenuation) under ideal noise-free conditions. The relative estimation error for arterial time-attenuation-curves is in the range of 8%, which is due to faster contrast dynamics in the artery. In general, performance depends on the level of acquired information contained in the projection data, which is mainly influenced by the type of rotational acquisition mode; restrictions in angular range and speed can lead to limited accuracy. The analysis of propagated projection noise in a statistical bias-variance framework reveals relative noise levels in estimated time-attenuation-curves of 3%-4% in tissue regions and below 1% in vessels when using optimized settings for regularization. Here, the effect of noise suppression depends on the interrelation between the number of iteration cycles and the constraints imposed by the temporal decomposition model. Conclusions: For usage with slowly rotating imaging systems, the presented model-based iterative dynamic reconstruction method is capable of recovering contrast time-attenuation-curves related to tissue perfusion. The proposed regularization framework is an effective means to limit the impact of projection noise, which is a factor dominating estimation accuracy in tissue regions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Towards Architecture and OS-Independent Malware Detection via Memory Forensics

In this work, we take a fundamentally different approach to the problem of analyzing a device for compromises via malware; our approach is OS and instruction architecture independent and relies only on having the raw binary data extracted from the memory dump of a device. Our system leverages a multi-hundred TB dataset of both compromised host memory dumps extracted from the MalRec dataset [8] and the first known dataset of benign host memory dumps running normal, non-compromised software. After an average of 30 to 45 seconds of pre-processing on a single memory dump, our system leverages both traditional machine learning and deep learning algorithms to achieve an average of 98% accuracy of detecting a compromised host.

Petrik, Rachel L.↗