Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Automated Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Seascape Interface Control Document

This paper serves as the Interface Control Document (ICD) for the Seascape automated test harness developed at Sandia National Laboratories. The primary purposes of the Seascape system are: (1) provide a place for accruing large, curated, labeled data sets useful for developing and evaluating detection and classification algorithms (including, but not limited to, supervised machine learning applications) (2) provide an automated structure for specifying, running and generating reports on algorithm performance. Seascape uses GitLab, Nexus, Solr, and Banana, open source software, together with code written in the Python language, to automatically provision and configure computational nodes, queue up jobs to accomplish algorithms test runs against the stored data sets, gather the results and generate reports which are then stored in the Nexus artifact server.

97 MATHEMATICS AND COMPUTING↗

Development of automated electromagnetic compatibility test facilities at Marshall Space Flight Center

The efforts to automate the electromagentic compatibility (EMC) test facilites at Marshall Flight Center were examined. A battery of nine standard tests is to be integrated by means of a desktop computer-controller in order to provide near real-time data assessment, store the data acquired during testing on flexible disk, and provide computer production of the certification report.

Harrison, Cecil A.↗

Oculomotor Assessment of Diurnal Arousal Variations

Saccadic and pupillary responses are reliable indices of arousal decrement (e.g. fatigue), that might be exploited to improve work schedule guidelines. In this study, we tested the sensitivity of a short 30-s oculomotor test to detect diurnal arousal variations. Twelve participants (5 females, 7 males, 37.7+-11.9 years) volunteered to be assessed every hour (66+-20 min) for three consecutive working days, during their regular office-hours. We used a fully automated testing system, the FIT 2000 Fitness Impairment Tester (Pulse Medical Instruments Inc., Rockville, MD, USA), to measure and record saccadic peak velocity, pupil diameter, and latency and amplitude of the pupillary light reflex. In addition, we collected subjective levels of arousal using the Stanford Sleepiness Scale, and body core temperature. We analyzed the data using a linear mixed model approach for longitudinal data. Both saccadic velocity and subjective alertness decreased over the course of a day, while body core temperature increased (all p-values.05). The data also weakly suggested an increase of the pupil diameter (p 07). The findings support the use of oculomotor indices in the assessment of arousal and fatigue in applied settings.

saccadic velocity↗

Results of accelerated thermal cycle tests of solar cells modules

Various candidate solar panel designs were evaluated, both theoretically and experimentally, with respect to their thermal cycling survival capability, and in particular with respect to an accelerated simulation of thermal cycles representative of Viking '75 mission requirements. The experimental results were obtained on 'mini-panels' thermally cycled in a newly installed automated test facility herein described. The resulting damage was analyzed physically and theoretically, and on the basis of these analyses the panel design was suitably modified to significantly improve its ability to withstand the thermal environment. These successful modifications demonstrate the value of the complementary theoretical-experimental approach adopted, and discussed in detail in this paper.

Berman, P.↗

Update to the Microcontroller Benchmark for Radiation Testing

LANL developed a benchmark of software code for radiation testing of microprocessors several years ago, and it was published under an open-source license on GitHub. Publishing the software is necessary for other researchers to adopt and implement this benchmark for radiation testing of other microprocessors to standardize test practices so that test data can be compared across different microprocessors. The original codes have been used several times by other organizations to test a wide range of microcontrollers and microprocessors. After several years of research, LANL is ready to update the benchmark. Changes include: 1. Addition of new codes that allow common software codes to be tested, 2. Addition of new codes that instrument more microprocessor circuitry, 3. Addition of input patterns that allow for a more compressive understanding of how the memory layout affects the sensitivity to radiation-induced faults and better use of automated test pattern generation standards, and 4. Modification of current codes for faster and more resilient detection, reporting and correction of radiation-induced faults. These codes have been tested by LANL researchers over the last few years, which has been published in the open literature. As the code base for the new benchmarks are stable, it is time to release the update to the GitHub repository, where the original codes were released.

Quinn, Heather↗

Sample Processor for Life on Icy Worlds (SPLIce): Design and Test Results

We report the design, development, and testing of the Sample Processor for Life on Icy Worlds (SPLIce) system, a microfluidic sample processor to enable autonomous detection of signatures of life and measurements of habitability parameters in Ocean Worlds. This monolithic fluid processing-and-handling system (Figure 1; mass 0.5 kg) retrieves a 50-L-volume sample and prepares it to supply a suite of detection instruments, each with unique preparation needs. SPLIce has potential applications in orbiter missions that sample ocean plumes, such as found in Saturns icy moon Enceladus, or landed missions on the surface of icy satellites, such as Jupiters moon Europa. Answering the question Are we alone in the universe? is captivating and exceptionally challenging. Even general criteria that define life very broadly include a significant role for water [1,2]. Searches for extinct or extant life therefore prioritize locations of abundant water whether in ancient (Mars), or present (Europa and Enceladus) times. Only two previous planetary missions had onboard fluid processing: the Viking Biology Experiments [3] and Phoenixs Wet Chemistry Laboratory (WCL) [4]. SPLIce differs crucially from those systems, including its capability to process and distribute L-volume samples and the integration autonomous control of a wide range of fluidic functions, including: 1) retrieval of fluid samples from an evacuated sample chamber; 2) onboard multi-year storage of dehydrated reagents; 3) integrated pressure, pH, and conductivity measurement; 4) filtration and retention of insoluble particles for microscopy; 5) dilution or vacuum-driven concentration of samples to accommodate instrument working ranges; 6) removal of gas bubbles from sample aliquots; 7) unidirectional flow (check valves); 8) active flow-path selection (solenoid-actuated valves); 9) metered pumping in 100 nL volume increments. The SPLIce manifold, made of three thermally fused layers of precision-machined cyclo-olefin polymer, supports all fluidic components (Figure 1) and integrated microchannels (125 x 250 m). Fluid is pumped by a stepper-motor-driven pump (Lee Co.). The functionality of the integrated MEMS pressure sensor (Honeywell) and passive check valves (Figure 2) were tested in conjunction with our newly designed integral bubble traps (Figure 3) and hydrophobic membrane-based concentrator (Figure 4). The concentrator (initially tested as a standalone component) demonstrated 5-fold vacuum-evaporative concentration. Polyethylene fused bead beds (PEFBBs; 50 porosity) store drylyophilized buffers, calibrants, and fluorescent dyes, and also promote mixing of sample with calibrant, dye, or H2O. Software-controlled automated tests demonstrated successful 1) fluid delivery to each component 2) valve and pump synchronization 3) sample aliquot delivery to instrument interface ports, and 4) rehydration of vacuum-dried fluorescent dye. In Figure 5, fluorescein on PEFBBs was rehydrated for 15 min using a pump-delivered water aliquot; it is displaced as H2O enters the bottom of the channel and pushes the dye into a check valve. Ultimately, SPLIce will fluorescently label amino acids in the sample for microchip-based electrophoretic (MCE) chiral separation and detection to seek and quantify key organic bio-signatures [5]; it will also deliver sample to a microfluidic version of WCL (mWCL) to measure soluble ions and redox-active species.

Life detection↗

Field-Emission Properties of Vertically Aligned Carbon Nanotube Cathodes of Varying Geometries

This work characterizes the bulk emission properties of carbon nanotube (CNT) forest cathodes fabricated with various geometries. Geometries explored include dense nanotube forests of varying height grown on 5×5 mm silicon (Si) substrates and discrete, patterned CNT pillars fabricated using UV photolithography. Dense forests heights ranged from 526 μ m to 1.41 mm, with packing fraction for dense forest calculated to be 4e10 nanotubes/cm2 based on an average nanotube separation distance of 100 nm for fixed growth dense forests. Patterned sample micro pillar heights ranged from 47 to 393 μ m with pillar widths on tested samples ranging from 250 to 270 μ m . Properties explored include emission current, turn-on field, and emission current performance over time. A parallel plate electron beam diode with a 100- μ m A-K gap and an automated test apparatus were developed to provide a configurable experiment that provides accurate and repeatable measurements for dc, dc sweep, and timed performance testing. Operating voltages for the voltage sweeps spanned from 0 to −350 V. Furthermore, testing has shown evidence of a hysteresis effect on the emission current tied to the applied field history as well as shifting of the turn-on field magnitude throughout the testing period, suggesting a conditioning effect during use. Three separate emission regions in the I–V curves during sweep testing have also been observed. In the geometric study, dense forests and patterned samples were sweep tested up to a peak applied voltage of −250 V, with the taller samples generally performing better. Currents produced in the geometric study from the dense forest emitters ranged from 36.8 to 572.34 μ A , with current densities ranging from 15 to 2.29 mA/cm2. Currents produced from the patterned micropillar emitters ranged from 39.4 to 317.51 μ A , with current densities ranging from 67 to 3 mA/cm2. DC time testing s...

36 MATERIALS SCIENCE↗

Automated Characterization of Uranium-Molybdenum Fuel Microstructures

Currently, performance evaluators rely on visual inspection or manual segmentation to assess most parameters of interest within an irradiated microstructure. Automating this process has the potential to significantly speed up the data extraction process, enhance its reliability, and improve its correctness. Automatic image segmentation of target features is a critical tool for providing measurements of features that may be used to increase the fidelity of fuel performance modeling. This summary will present the progress made in developing and testing automated image processing routines capable of fully characterizing the presence of fission gas bubbles in irradiated U-Mo plate-type fuel microstructures.

Image Processing↗

Monitoring system for testing the radiation hardness of a KINTEX-7 FPGA

A much more efficient Ring Imaging Cherenkov sub-detector system will be rebuilt in the second long shutdown of Large Hadron Collider for the LHCb experiment. Radiation-hard electronic components together with Commercial Off-The-Shelf ones will be used in the new Cherenkov photon detection system architecture. An irradiation program was foreseen to determine the radiation tolerance for the new electronic devices, including a Field Programmable Gate Array from KINTEX-7 family of XILINX. An automated test bench for online monitoring of the XC7K70T KINTEX-7 device operation in radiation conditions was designed and implemented by the LHCb Romanian group.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mars Science Laboratory Flight Software Internal Testing

The Mars Science Laboratory (MSL) team is sending the rover, Curiosity, to Mars, and therefore is physically and technically complex. During my stay, I have assisted the MSL Flight Software (FSW) team in implementing functional test scripts to ensure that the FSW performs to the best of its abilities. There are a large number of FSW requirements that have been written up for implementation; however I have only been assigned a few sections of these requirements. There are many stages within testing; one of the early stages is FSW Internal Testing (FIT). The FIT team can accomplish this with simulation software and the MSL Test Automation Kit (MTAK). MTAK has the ability to integrate with the Software Simulation Equipment (SSE) and the Mission Processing and Control System (MPCS) software which makes it a powerful tool within the MSL FSW development process. The MSL team must ensure that the rover accomplishes all stages of the mission successfully. Due to the natural complexity of this project there is a strong emphasis on testing, as failure is not an option. The entire mission could be jeopardized if something is overlooked.

entry, descent, and landing (EDL)↗

Automation of electromagnetic compatability (EMC) test facilities

Efforts to automate electromagnetic compatibility (EMC) test facilities at Marshall Space Flight Center are discussed. The present facility is used to accomplish a battery of nine standard tests (with limited variations) deigned to certify EMC of Shuttle payload equipment. Prior to this project, some EMC tests were partially automated, but others were performed manually. Software was developed to integrate all testing by means of a desk-top computer-controller. Near real-time data reduction and onboard graphics capabilities permit immediate assessment of test results. Provisions for disk storage of test data permit computer production of the test engineer's certification report. Software flexibility permits variation in the tests procedure, the ability to examine more closely those frequency bands which indicate compatibility problems, and the capability to incorporate additional test procedures.

Harrison, C. A.↗

Computerized System for Safety Verification of External Beam Radiation Therapy Planning

Purpose: To report an assessment of in-house software, Verifier, developed to improve efficacy and efficiency of the radiation therapy (RT) treatment planning process and quality control review (QCR). Methods and Materials: Radiation therapy plan parameters retrieved from our treatment planning database are used by automated tests to give 75 types of warnings, such as prescription and plan discrepancies. The software is continuously updated on the basis of new issues, ideas, and planning policies. Verifier was retrospectively assessed (2007-2015) by examining impact on treatment plan revisions, frequency of quality improvement incident reports of avoidable RT plan-related safety events, unaddressed issues, and staff efficiency. Results: Plan revisions for specific issues declined dramatically in response to implementation of corresponding Verifier tests. Between 2012 and 2015 our institution's total rate of plan revisions dropped from 18.0% to 11.2%. Between 2008 and 2015 specific tests were added to Verifier while the rate of corresponding avoidable safety events was reduced from 0.34% to 0.00% over the same period. Simulations suggest Verifier saves approximately 2 to 5 minutes per QCR. Conclusions: The decrease in quantifiable metrics of plan revisions and incident reports suggests automatic RT plan-checking software enhances patient safety and clinical efficiency. Although only modest time savings may be gained using Verifier for the QCR itself, the greater impact on efficiency is through avoiding late-stage plan modifications and improving documentation via automation. We encourage other institutions to consider working toward adding similar technologies to enhance their RT quality assurance programs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

First On-Wafer Power Characterization of MMIC Amplifiers at Sub-Millimeter Wave Frequencies

Recent developments in semiconductor technology have enabled advanced submillimeter wave (300 GHz) transistors and circuits. These new high speed components have required new test methods to be developed for characterizing performance, and to provide data for device modeling to improve designs. Current efforts in progressing high frequency testing have resulted in on-wafer-parameter measurements up to approximately 340 GHz and swept frequency vector network analyzer waveguide measurements to 508 GHz. On-wafer noise figure measurements in the 270-340 GHz band have been demonstrated. In this letter we report on on-wafer power measurements at 330 GHz of a three stage amplifier that resulted in a maximum measured output power of 1.78mW and maximum gain of 7.1 dB. The method utilized demonstrates the extension of traditional power measurement techniques to submillimeter wave frequencies, and is suitable for automated testing without packaging for production screening of submillimeter wave circuits.

monolithic microwave integrated circircuit↗

An expert system for simulating electric loads aboard Space Station Freedom

Space Station Freedom will provide an infrastructure for space experimentation. This environment will feature regulated access to any resources required by an experiment. Automated systems are being developed to manage the electric power so that researchers can have the flexibility to modify their experiment plan for contingencies or for new opportunities. To define these flexible power management characteristics for Space Station Freedom, a simulation is required that captures the dynamic nature of space experimentation; namely, an investigator is allowed to restructure his experiment and to modify its execution. This changes the energy demands for the investigator's range of options. An expert system competent in the domain of cryogenic fluid management experimentation was developed. It will be used to help design and test automated power scheduling software for Freedom's electric power system. The expert system allows experiment planning and experiment simulation. The former evaluates experimental alternatives and offers advice on the details of the experiment's design. The latter provides a real-time simulation of the experiment replete with appropriate resource consumption.

Kukich, George↗

An expert system for simulating electric loads aboard Space Station Freedom

Space Station Freedom will provide an infrastructure for space experimentation. This environment will feature regulated access to any resources required by an experiment. Automated systems are being developed to manage the electric power so that researchers can have the flexibility to modify their experiment plan for contingencies or for new opportunities. To define these flexible power management characteristics for Space Station Freedom, a simulation is required that captures the dynamic nature of space experimentation; namely, an investigator is allowed to restructure his experiment and to modify its execution. This changes the energy demands for the investigator's range of options. An expert system competent in the domain of cryogenic fluid management experimentation, was developed. It will be used to help design and test automated power scheduling software for Freedom's electric power system. The expert system allows experiment planning and experiment simulation. The former evaluates experimental alternatives and offers advice on the details of the experiment's design. The latter provides a real-time simulation of the experiment replete with appropriate resource consumption.

Kukich, George↗

The Language Research Center's Computerized Test System for environmental enrichment and psychological assessment

In the spring of 1987, we undertook to provide environmental enrichment to nonhuman primate subjects in ways that would complement and even contribute to the bio-behaviorial science that justified the monkeys' captivity. Of course, the psychological well-being of captive primates--and indeed all research species-- has been an area of intense research activity since the 1985 amendment of the Animal Welfare Act. This mandate for researchers to ensure the psychological, as well as physical, fitness of experimental animals catalyzed the humane and scientific interests of the research community. The contemporary literature is replete with proposed means both of assaying and of providing enrichment and well-being. Notwithstanding, consensus on either assessment or intervention has yet to be reached. The paradigm we employed was modelled after successful efforts with chimpanzees. An automated test system was constructed in which subjects responded to computer tasks by manipulating a joystick. The tasks, interactive game-like versions of many of the classic testing paradigms of cognitive and comparative psychology, permitted the controlled presentation of stimuli and demands without the required presence of a human experimenter. Despite significant barriers to the success, rhesus monkeys (Macaca mulatta) and a variety of other primate species (including, of course, humans) have mastered the skills necessary for testing in this paradigm. Previous experiments have illustrated the utility of the test system for addressing questions of learning, memory, attention, perception, and motivation. Additional data have been reported to support the contention that the Language Research Center's Computerized Test System (LRC-CTS) serves its other raison d'etre--providing environmental enrichment and assessing psychological well-being. This paper is designed to augment previous descriptions of the technology and the paradigm for scientists and caretakers interested in environmental enrichment and performance assessment with primates.

Non-NASA Center↗

Model-Based GN and C Simulation and Flight Software Development for Orion Missions beyond LEO

For Orion missions beyond low Earth orbit (LEO), the Guidance, Navigation, and Control (GN&C) system is being developed using a model-based approach for simulation and flight software. Lessons learned from the development of GN&C algorithms and flight software for the Orion Exploration Flight Test One (EFT-1) vehicle have been applied to the development of further capabilities for Orion GN&C beyond EFT-1. Continuing the use of a Model-Based Development (MBD) approach with the Matlab®/Simulink® tool suite, the process for GN&C development and analysis has been largely improved. Furthermore, a model-based simulation environment in Simulink, rather than an external C-based simulation, greatly eases the process for development of flight algorithms. The benefits seen by employing lessons learned from EFT-1 are described, as well as the approach for implementing additional MBD techniques. Also detailed are the key enablers for improvements to the MBD process, including enhanced configuration management techniques for model-based software systems, automated code and artifact generation, and automated testing and integration.

Odegard, Ryan↗