Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Arms Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Passive high explosive neutron inspection (PHENIX): a new method to confirm the presence or absence of high explosives for nuclear treaty verification

Advanced instruments and methods need to be developed now to create a technical basis to support the negotiation of future nuclear arms control treaties. One new capability that is anticipated is the ability to confirm either the declared presence or declared absence of high explosive (HE) material in the presence of special nuclear material (SNM). Towards this goal, Passive HE Neutron Inspection (PHENIX) has been developed and demonstrated as a method for confirming the presence or absence of HE in the presence of plutonium. The method exploits the inherent presence of neutrons associated with the decay of plutonium as an internal probe source for performing prompt gamma-ray neutron activation analysis (PGNAA), searching for the presence of HE as revealed by the emission of characteristic gamma rays following neutron absorption in hydrogen and nitrogen which are building blocks of present-day, military-grade HE. Tests using stoichiometrically-correct hemishells of mock HE with plutonium show that a system can be expected to positively confirm the presence or absence of these signatures, supporting determination of HE presence or absence with Pu, in a few hours. To protect other potentially sensitive gamma-ray signatures from a treaty accountable item, an analog information barrier has been conceptualized and tested which physically prevents the collection of gamma-ray spectral data outside of user selected energy windows strategically chosen to view only narrow spectral regions corresponding to the hydrogen (2223.2 keV) and nitrogen (9807.2 keV, 10,318.2 keV, and 10,829.2 keV) PGNAA signatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing a detection system for fissile material in nuclear disarmament verification

In arms control treaties, verification plays a crucial role in detecting non-compliance, deterring future violations, and building trust between state parties. Neutron interrogation that induces fission reactions in fissile isotopes and measures the resulting fission neutrons, could be employed for this purpose. This study aims to develop a system which can determine the presence of fissile material while intrinsically protecting information. In this paper, we focus on optimizing the system for discriminating between an enriched uranium block from a depleted uranium (DU) block. The system was built and we report on benchmark measurements with DU and 16% enriched uranium blocks. Furthermore, the Excalibur (Experiment for Calibration with Uranium) neutron source, a neutron spectrometer (redBubble Technology Industries (BTI) N-Probe), and superheated droplet detectors were used for these measurements. MCNP simulations provided insights into detector responses to fissile materials with varying isotopic compositions, confirming that the system functioned as designed.

Active neutron interrogation↗

Monitoring and verification R&D

The 2010 Nuclear Posture Review (NPR) report outlined the Administration's approach to promoting the agenda put forward by President Obama in Prague on April 5, 2009. The NPR calls for a national monitoring and verification R&D program to meet future challenges arising from the Administration's nonproliferation, arms control and disarmament agenda. Verification of a follow-on to New START could have to address warheads and possibly components along with delivery capabilities. Deeper cuts and disarmament would need to address all of these elements along with nuclear weapon testing, nuclear material and weapon production facilities, virtual capabilities from old weapon and existing energy programs and undeclared capabilities. We only know how to address some elements of these challenges today, and the requirements may be more rigorous in the context of deeper cuts as well as disarmament. Moreover, there is a critical need for multiple options to sensitive problems and to address other challenges. There will be other verification challenges in a world of deeper cuts and disarmament, some of which we are already facing. At some point, if the reductions process is progressing, uncertainties about past nuclear materials and weapons production will have to be addressed. IAEA safeguards will need to continue to evolve to meet current and future challenges, and to take advantage of new technologies and approaches. Transparency/verification of nuclear and dual-use exports will also have to be addressed, and there will be a need to make nonproliferation measures more watertight and transparent. In this context, and recognizing we will face all of these challenges even if disarmament is not achieved, this paper will explore possible agreements and arrangements; verification challenges; gaps in monitoring and verification technologies and approaches; and the R&D required to address these gaps and other monitoring and verification challenges.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A Mechanically-Cooled, Highly-Portable, HPGe-Based, Coded-Aperture Gamma-Ray Imager

Coded-aperture gamma-ray imaging is a mature technology that is capable of providing accurate and quantitative images of nuclear materials. Although it is potentially of high value to the safeguards and arms-control communities, it has yet to be fully embraced by those communities. One reason for this is the limited choice, high-cost, and low efficiency of commercial instruments; while instruments made by research organizations are frequently large and / or unsuitable for field work. In this paper we present the results of a project that mates the coded-aperture imaging approach with the latest in commercially-available, position-sensitive, High Purity Germanium (HPGe) detec-tors. The instrument replaces a laboratory prototype that, was unsuitable for other than demonstra-tions. The original instrument, and the cart on which it is mounted to provide mobility and pointing capabilities, has a footprint of ~ 2/3 m x 2 m, weighs ~ 100 Kg, and requires cryogen refills every few days. In contrast, the new instrument is tripod mounted, weighs of order 25 Kg, operates with a laptop computer, and is mechanically cooled. The instrument is being used in a program that is ex-ploring the use of combined radiation and laser scanner imaging. The former provides information on the presence, location, and type of nuclear materials while the latter provides design verification information. To align the gamma-ray images with the laser scanner data, the Ge imager is fitted and aligned to a visible-light stereo imaging unit. This unit generates a locus of 3D points that can be matched to the precise laser scanner data. With this approach, the two instruments can be used completely independently at a facility, and yet the data can be accurately overlaid based on the very structures that are being measured.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Recent Developments In Fast Neutron Detection And Multiplicity Counting With Verification With Liquid Scintillator

For many years at LLNL, we have been developing time-correlated neutron detection techniques and algorithms for applications such as Arms Control, Threat Detection and Nuclear Material Assay. Many of our techniques have been developed specifically for the relatively low efficiency (a few percent) attainable by detector systems limited to man-portability. Historically, we used thermal neutron detectors (mainly {sup 3}He), taking advantage of the high thermal neutron interaction cross-sections. More recently, we have been investigating the use of fast neutron detection with liquid scintillators, inorganic crystals, and in the near future, pulse-shape discriminating plastics which respond over 1000 times faster (nanoseconds versus tens of microseconds) than thermal neutron detectors. Fast neutron detection offers considerable advantages, since the inherent nanosecond production time-scales of spontaneous fission and neutron-induced fission are preserved and measured instead of being lost by thermalization required for thermal neutron detectors. We are now applying fast neutron technology to the safeguards regime in the form of fast portable digital electronics as well as faster and less hazardous scintillator formulations. Faster detector response times and sensitivity to neutron momentum show promise for measuring, differentiating, and assaying samples that have modest to very high count rates, as well as mixed fission sources like Cm and Pu. We report on measured results with our existing liquid scintillator array, and progress on the design of a nuclear material assay system that incorporates fast neutron detection, including the surprising result that fast liquid scintillator detectors become competitive and even surpass the precision of {sup 3}He-based counters measuring correlated pairs in modest (kg) samples of plutonium.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Delayed Gamma-Ray Spectroscopy for Non-Destructive Assay of Nuclear Materials

High-­energy, beta-delayed gamma-­ray spectroscopy is a potential, non-­destructive assay techniques for the independent verification of declared quantities of special nuclear materials at key stages of the fuel cycle and for directly assaying nuclear material inventories for spent fuel handling, interim storage, reprocessing facilities, repository sites, and final disposal. Other potential applications include determination of MOX fuel composition, characterization of nuclear waste packages, and challenges in homeland security and arms control verification. Experimental measurements were performed to evaluate fission fragment yields, to test methods for determining isotopic fractions, and to benchmark the modeling code package. Experimental measurement campaigns were carried out at the IAC using a photo-­neutron source and at OSU using a thermal neutron beam from the TRIGA reactor to characterize the emission of high-­energy delayed gamma rays from 235 U, 239 Pu, and 241 Pu targets following neutron induced fission. Data were collected for pure and combined targets for several irradiation/spectroscopy cycle times ranging from 10/10 seconds to 15/30 minutes.The delayed gamma-ray signature of 241 Pu, a significant fissile constituent in spent fuel, was measured and compared to 239 Pu. The 241 Pu/ 239 Pu ratios varied between 0.5 and 1.2 for ten prominent lines in the 2700-­3600 keV energy range. Such significant differences in relative peak intensities make it possible to determine relative fractions of these isotopes in a mixed sample. A method for determining fission product yields by fitting the energy and time dependence of the delayed gamma-­ray emission was developed and demonstrated on a limited 235 U data set. De-­convolution methods for determining fissile fractions were developed and tested on the experimental data. The use of high count-­rate LaBr 3 detectors was investigated as a potential alternative to HPGe detectors. Modeling capabilities were added to an existing framework and codes were adapted as needed for analyzing experiments and assessing application-­specific assay concepts. A de-­convolution analysis of the delayed gamma-­ray response spectra modeled for spent fuel assemblies was performed using the same method that was applied to the experimental spectra.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thoughts on Verification of Nuclear Disarmament

It is my pleasure to be here to day to participate in this Conference. My thanks to the organizers for preparing such an interesting agenda on a very difficult topic. My effort in preparing my presentation was performed under the auspices of the U.S. Department of Energy by University of California, Lawrence Livermore National Laboratory under Contract W-7405-Eng-48. And as many of you know Lawrence Livermore National Laboratory is now, as of Oct 1st, under contract to the Lawrence Livermore National Security LLC. There has been a long history of how to view verification of arms control agreements. The basis for verification during the days of SALT was that verification would be based on each country's national technical means. For treaties dealing with strategic missiles this worked well as the individual items subject to verification were of such a size that they were visible by the National Technical Means available at the time. And it was felt that the counting of missiles and launchers could be verified by our National Technical Means. For nuclear testing treaties the use of seismic measurements developed into a capability that was reasonably robust for all but the smallest of nuclear tests. However, once we had the Threshold Test Ban Treaty, there was a significant problem in that the fidelity of the measurements were not sufficient to determine if a test was slightly above the 150 kt limit or slightly below the 150 kt limit. This led some in the US to believe that the Soviet Union was not living up to the TTBT agreement. An on-site verification protocol was negotiated in 1988 and 1989 that allowed the US to make hydrodynamic yield measurements on Soviet tests above 50 kt yield and regional seismic measurements on all tests above 35 kt of yield; and the Soviets to make the same type of measurements on US tests to ensure that they were not over 150 kt. These on-site measurements were considered reasonably intrusive. Again the measurement capability was not perfect and it was expected that occasionally there might be a verification measurement that was slightly above 150 kt. But the accuracy was much improved over the earlier seismic measurements. In fact some of this improvement was because as part of this verification protocol the US and Soviet Union provided the yields of several past tests to improve seismic calibrations. This actually helped provide a much needed calibration for the seismic measurements. It was also accepted that since nuclear tests were to a large part R&D related, it was also expected that occasionally there might be a test that was slightly above 150 kt, as you could not always predict the yield with high accuracy in advance of the test. While one could hypothesize that the Soviets could do a test at some other location than their test sites, if it were even a small fraction of 150 kt it would clearly be observed and would be a violation of the treaty. So the issue of clandestine tests of significance was easily covered for this particular treaty.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Imaging Biomarker Dynamics in an Intracranial Murine Glioma Study of Radiation and Antiangiogenic Therapy

Purpose: There is a growing need for noninvasive biomarkers to guide individualized spatiotemporal delivery of radiation therapy (RT) and antiangiogenic (AA) therapy for brain tumors. This study explored early biomarkers of response to RT and the AA agent sunitinib (SU), in a murine intracranial glioma model, using serial magnetic resonance imaging (MRI). Methods and Materials: Mice with MRI-visible tumors were stratified by tumor size into 4 therapy arms: control, RT, SU, and SU plus RT (SURT). Single-fraction conformal RT was delivered using MRI and on-line cone beam computed tomography (CT) guidance. Serial MR images (T2-weighted, diffusion, dynamic contrast-enhanced and gadolinium-enhanced T1-weighted scans) were acquired biweekly to evaluate tumor volume, apparent diffusion coefficient (ADC), and tumor perfusion and permeability responses (K{sub trans}, K{sub ep}). Results: Mice in all treatment arms survived longer than those in control, with a median survival of 35 days for SURT (P<.0001) and 30 days for RT (P=.009) and SU (P=.01) mice vs 26 days for control mice. At Day 3, ADC rise was greater with RT than without (P=.002). Sunitinib treatment reduced tumor perfusion/permeability values with mean K{sub trans} reduction of 27.6% for SU (P=.04) and 26.3% for SURT (P=.04) mice and mean K{sub ep} reduction of 38.1% for SU (P=.01) and 27.3% for SURT (P=.02) mice. The magnitude of individual mouse ADC responses at Days 3 and 7 correlated with subsequent tumor growth rate R values of −0.878 (P=.002) and −0.80 (P=.01), respectively. Conclusions: Early quantitative changes in diffusion and perfusion MRI measures reflect treatment responses soon after starting therapy and thereby raise the potential for these imaging biomarkers to guide adaptive and potentially individualized therapy approaches in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PROACTIVE FA4: Progress Update 2024

The Priority Research Objectives for Arms Control Technology Innovation, Verification, and Evaluation (PROACTIVE) venture’s overall goal is to address the technical challenges that will “enable the negotiation and implementation of future nuclear arms limitation/reduction treaties with verification at the level of individual warheads by advancing the state of the art in verification and monitoring capabilities.” One of the four focus areas of the venture, Focus Area 4 (FA4), is a system-of-systems effort to establish methodologies for the integration of monitoring and verification (M&V) technologies into verification systems that support treaty objectives.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A Discrete Event Simulation Approach to Nuclear Arms Enterprise Modeling and Analysis

We overview a discrete event simulation of an arms control enterprise developed to familiarize individuals with the challenges of verification and monitoring at the enterprise level. We will review the design of the simulation applied to a notional country’s nuclear arms enterprise. This simulation models how these nuclear weapons move over their lifetime from deployment, storage, maintenance, and dismantlement. With this output information, we then characterize the “ground truth” of the enterprise. Next, based on these data, we built a sophisticated analysis engine designed to provide treaty monitoring and verification information to support partner country inspectors and their evaluation. This tool was designed to be used as a game, enabling teams to compete on developing the best inspection plan to determine if the host country is complying with the conceptual treaty developed for this effort.

Pulliam, Rachel M.↗

WE-FG-BRA-01: Cancer Treatment Utilizing Photo-Activation of Psoralen with KV X-Rays

Purpose: This work investigates X-PACT (X-ray Psoralen Activated Cancer Therapy): a new approach for the treatment of cancer. X-PACT utilizes psoralen, a potent anti-cancer therapeutic with immunogenic anti-cancer potential. Psoralen therapies have been limited due to the requirement for psoralen activation by UVA light. X-PACT solves this challenge by activating psoralen with UV light emitted from novel non-tethered phosphors (co-incubated with psoralen) that absorb x-rays and reradiate (phosphoresce) at UV wavelengths. Methods: The efficacy of X-PACT was evaluated in both in-vitro and in-vivo settings. In-vitro studies utilized breast (4T1), glioma (CT2A) and sarcoma (KP-B) cell lines. Cells were exposed to X-PACT treatments where the concentrations of drug (psoralen and phosphor) and radiation parameters (energy, dose, and dose rate) were varied. Efficacy was evaluated primarily using flow cell cytometry to investigate treatment induced apoptosis. Methylene blue staining, and WST assays were also used. X-PACT was then evaluated in an in-vivo pilot study on BALBc mice with syngeneic 4T1 tumors, including control arms for X-PACT components. Analysis focused on tumor growth delay. Results: A multivariable regression analysis of 36 independent in-vitro irradiation experiments demonstrated that X-PACT induces significant tumor cell apoptosis and cytotoxicity on all three tumor cell lines in-vitro (p<0.0001). Neither psoralen nor phosphor alone had a strongly significant effect. The in-vivo studies show a pronounced tumor growth delay when compared to controls (42% reduction at 25 days, p=0.0002). Conclusions: These studies demonstrate for the first time a therapeutic effect for X-PACT, and provide a foundation and rationale for future studies. X-PACT represents a novel treatment approach in which well-tolerated low doses of x-ray radiation generate UVA light in-situ (including deep seated lesions) which in-turn photo-activates powerful anticancer therapeutics which may lead to short and long term therapeutic effect. This work was supported by Immunolight Llc.

60 APPLIED LIFE SCIENCES↗

Remote inspection of adversary-controlled environments

Remotely monitoring the location and enduring presence of valuable items in adversary-controlled environments presents significant challenges. In this article, we demonstrate a monitoring approach that leverages the gigahertz radio-wave scattering and absorption of a room and its contents, including a set of mirrors with random orientations placed inside, to remotely verify the absence of any disturbance over time. Our technique extends to large physical systems the application of physical unclonable functions for integrity protection. Its main applications are scenarios where parties are mutually distrustful and have privacy and security constraints. Examples range from the verification of nuclear arms-control treaties to the securing of currency, artwork, or data centers.

47 OTHER INSTRUMENTATION↗

Prospective Evaluation of Quality of Life and Neurocognitive Effects in Patients With Multiple Brain Metastases Receiving Whole-Brain Radiotherapy With or Without Thalidomide on Radiation Therapy Oncology Group (RTOG) Trial 0118

Purpose: Radiation Therapy Oncology Group (RTOG) 0118 randomized patients with multiple brain metastases to whole-brain radiotherapy (WBRT) {+-} thalidomide. This secondary analysis of 156 patients examined neurocognitive and quality of life (QOL) outcomes. Methods and Materials: Quality of life was determined with the Spitzer Quality of Life Index (SQLI). The Folstein Mini-Mental Status Exam (MMSE) assessed neurocognitive function. SQLI and MMSE were administered at baseline and at 2-month intervals. MMSE was scored with a threshold value associated with neurocognitive functioning (absolute cutoff level of 23) and with the use of corrections for age and educational level. Results: Baseline SQLI predicted survival. Patients with SQLI of 7-10 vs. <7 had median survival time (MST) of 4.8 vs. 3.1 months, p = 0.05. Both arms showed steady neurocognitive declines, but SQLI scores remained stable. Higher levels of neurocognitive decline were observed with age and education-level corrections. Of patients considered baseline age/educational level neurocognitive failures, 32% died of intracranial progression. Conclusions: Quality of life and neuropsychological testing can be prospectively administered on a Phase III cooperative group trial. The MMSE should be evaluated with adjustments for age and educational level. Baseline SQLI is predictive of survival. Despite neurocognitive declines, QOL remained stable during treatment and follow-up. Poor neurocognitive function may predict clinical deterioration. Lack of an untreated control arm makes it difficult to determine the contribution of the respective interventions (i.e., WBRT, thalidomide) to neurocognitive decline. The RTOG has developed a trial to study the role of preventative strategies aimed at forestalling neurocognitive decline in this population.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ONIX: An open-source depletion code

Open Source software enables innovative, community-based software development. ONIX brings this concept to the field of depletion calculations. It is an open-source depletion software to be used for nuclear reactor simulations, for fissile material production analysis as well as for nuclear arms control applications. ONIX provides a module to solve the depletion equation using a Chebyshev Rational Approximation Method. For the generation of one-group cross sections, it includes a coupling interface for the open-source neutron transport code, OpenMC, as well as a module to read pre-computed values in a stand-alone mode. ONIX has special features to optimize nuclear data libraries, to update isomeric branching ratio during burnup, and to support automation of simulations for nuclear archaeology. In conclusion, ONIX has been validated against results from numerical and experimental benchmarks, and its results agree with other methods within expected error ranges.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Radiotherapy Breast Boost With Reduced Whole-Breast Dose Is Associated With Improved Cosmesis: The Results of a Comprehensive Assessment From the St. George and Wollongong Randomized Breast Boost Trial

Purpose: To evaluate comprehensively the effect of a radiotherapy boost on breast cosmetic outcomes after 5 years in patients treated with breast-conserving surgery. Methods: The St. George and Wollongong trial (NCT00138814) randomized 688 patients with histologically proven Tis-2, N 0-1, M0 carcinoma to the control arm of 50 Gy in 25 fractions (342 patients) and the boost arm of 45 Gy in 25 fractions to the whole breast followed by a 16 Gy in 8 fraction electron boost (346 patients). Five-year cosmetic outcomes were assessed by a panel subjectively in 385 patients and objectively using pBRA (relative breast retraction assessment). A subset of patients also had absolute BRA measurements. Clinician assessment and patient self-assessment of overall cosmetic and specific items as well as computer BCCT.core analysis were also performed. Results: The boost arm had improved cosmetic overall outcomes as scored by the panel and BCCT.core software with 79% (p = 0.016) and 81% (p = 0.004) excellent/good cosmesis respectively compared with 68% in no-boost arm. The boost arm also had lower pBRA and BRA values with a mean difference of 0.60 and 1.82 mm, respectively, but was not statistically significant. There was a very high proportion of overall excellent/good cosmetic outcome in 95% and 93% in the boost and no-boost arms using patient self-assessment. However, no difference in overall and specific items scored by clinician assessment and patient self-assessment was found. Conclusion: The results show the negative cosmetic effect of a 16-Gy boost is offset by a lower whole-breast dose of 45 Gy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Silver Clear Nylon Dressing is Effective in Preventing Radiation-Induced Dermatitis in Patients With Lower Gastrointestinal Cancer: Results From a Phase III Study

Purpose: For patients with anal canal and advanced rectal cancer, chemoradiation therapy is a curative modality or an important adjunct to surgery. Nearly all patients treated with chemoradiation experience some degree of radiation-induced dermatitis (RID). Prevention and effective treatment of RID, therefore, is of considerable clinical relevance. The present phase III randomized trial compared the efficacy of silver clear nylon dressing (SCND) with that of standard skin care for these patients. Methods and Materials: A total of 42 rectal or anal canal cancer patients were randomized to either a SCND or standard skin care group. SCND was applied from Day 1 of radiation therapy (RT) until 2 weeks after treatment completion. In the control arm, sulfadiazine cream was applied at the time of skin dermatitis. Printed digital photographs taken 2 weeks prior to, on the last day, and two weeks after the treatment completion were scored by 10 blinded readers, who used the common toxicity scoring system for skin dermatitis. Results: The radiation dose ranged from 50.4 to 59.4 Gy, and there were no differences between the 2 groups. On the last day of RT, when the most severe RID occurs, the mean dermatitis score was 2.53 (standard deviation [SD], 1.17) for the standard and 1.67 (SD, 1.2; P=.01) for the SCND arm. At 2 weeks after RT, the difference was 0.39 points in favor of SCND (P=.39). There was considerable intraclass correlation among the 10 observers. Conclusions: Silver clear nylon dressing is effective in reducing RID in patients with lower gastrointestinal cancer treated with combined chemotherapy and radiation treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anti-PD-1 Blockade and Stereotactic Radiation Produce Long-Term Survival in Mice With Intracranial Gliomas

Purpose: Glioblastoma multiforme (GBM) is the most common primary brain tumor in adults, and radiation is one of the main treatment modalities. However, cure rates remain low despite best available therapies. Immunotherapy is a promising modality that could work synergistically with radiation, which has been shown to increase antigen presentation and promote a proinflammatory tumor microenvironment. Programmed-death-1 (PD-1) is a surface receptor expressed on activated and exhausted T cells, which mediate T cell inhibition upon binding with its ligand PD-L1, expressed on many tumor types including human GBMs. We tested the combination of anti-PD-1 immunotherapy with stereotactic radiosurgery in a mouse orthotopic GBM model. Methods and Materials: We performed intracranial implantation of mouse glioma cell line GL261 transfected with luciferase into C57BL/6 mice. Mice were stratified into 4 treatment groups: (1) control; (2) radiation only; (3) anti-PD-1 antibody only; and (4) radiation plus anti-PD-1 antibody. Overall survival was quantified. The mice were killed on day 21 after implantation to assess immunologic parameters in the brain/tumor, cervical lymph nodes, and spleen. Results: Improved survival was demonstrated with combination anti-PD-1 therapy plus radiation compared with either modality alone: median survival was 25 days in the control arm, 27 days in the anti-PD-1 antibody arm, 28 days in the radiation arm, and 53 days in the radiation plus anti-PD-1 therapy arm (P<.05 by log-rank Mantle-Cox). Long-term survival was seen only in the combined treatment arm, with a fraction (15%-40%) of animals alive at day 180+ after treatment. Immunologic data on day 21 after implantation showed increased tumor infiltration by cytotoxic T cells (CD8+/interferon-γ+/tumor necrosis factor-α+) and decreased regulatory T cells (CD4+/FOXP3) in the combined treatment group compared with the single modality arms. Conclusions: The combination of PD-1 blockade and localized radiation therapy results in long-term survival in mice with orthotopic brain tumors. These studies provide strong preclinical evidence to support combination trials in patients with GBM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase 3 Trial of Domiciliary Humidification to Mitigate Acute Mucosal Toxicity During Radiation Therapy for Head-and-Neck Cancer: First Report of Trans Tasman Radiation Oncology Group (TROG) 07.03 RadioHUM Study

Purpose: To assess the impact of domicile-based humidification on symptom burden during radiation therapy (RT) for head-and-neck (H and N) cancer. Methods and Materials: From June 2007 through June 2011, 210 patients with H and N cancer receiving RT were randomized to either a control arm or to receive humidification using the Fisher and Paykel Healthcare MR880 humidifier. Humidification commenced on day 1 of RT and continued until Common Terminology Criteria for Adverse Events (CTCAE), version 3.0, clinical mucositis (CMuc) grade ≤1 occurred. Forty-three patients (42%) met a defined benchmark for humidification compliance and contributed to per protocol (PP) analysis. Acute toxicities, hospitalizations, and feeding tube events were recorded prospectively. The McMaster University Head and Neck Radiotherapy Questionnaire (HNRQ) was used for patient-reported outcomes. The primary endpoint was area under the curve (AUC) for CMuc grade ≥2. Results: There were no significant differences in AUC for CMuc ≥2 between the 2 arms. Humidification patients had significantly fewer days in hospital (P=.017). In compliant PP patients, the AUC for CTCAE functional mucositis score (FMuc) ≥2 was significantly reduced (P=.009), and the proportion who never required a feeding tube was significantly greater (P=.04). HNRQ PP analysis estimates also in the direction favoring humidification with less symptom severity, although differences at most time points did not reach significance. Conclusions: TROG 07.03 has provided efficacy signals consistent with a role for humidification in reducing symptom burden from mucositis, but the influence of humidification compliance on the results moderates recommendations regarding its practical utility.

62 RADIOLOGY AND NUCLEAR MEDICINE↗