Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Angular Reference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

The significance of vector magnetic field measurements

Observations of four flaring solar active regions, obtained during 1980-1986 with the NASA Marshall vector magnetograph (Hagyard et al., 1982 and 1985), are presented graphically and characterized in detail, with reference to nearly simultaneous Big Bear Solar Observatory and USAF ASW H-alpha images. It is shown that the flares occurred where local photospheric magnetic fields differed most from the potential field, with initial brightening on either side of a magnetic-neutral line near the point of maximum angular shear (rather than that of maximum magnetic-field strength, typically 1 kG or greater). Particular emphasis is placed on the fact that these significant nonpotential features were detected only by measuring all three components of the vector magnetic field.

Hagyard, M. J.↗

Slew maneuver dynamics of the Spacecraft Control Laboratory experiment

Mathematical expressions for slew maneuver dynamics are presented. The total kinetic energy expression of the system is given as T = T(0) + T(1) + T(2), where T(0), T(1), and T(2) refer to the kinetic energies of the shuttle, the flexible beam, and the tip mass (the reflector), respectively. The specific equations for each of these are defined and integrated into the total energy expression. Using the chain rule in the Lagrange equations and an expression allowing the transformation of the orbiter angular velocity from the inertial frame to the body-fixed frame, the rotational equations are obtained. Finally, the vibration equations for the beam are derived, again using the Lagrange equations.

Kakad, Y. P.↗

The Berkeley extreme ultraviolet calibration facility

The vacuum calibration facilities of the Space Sciences Laboratory, University of California at Berkeley are designed for the calibration and testing of EUV and FUV spaceborne instrumentation (spectral range 44-2500 A). The facility includes one large cylindrical vacuum chamber (3 x 5 m) containing two EUV collimators, and it is equipped with a 4-axis manipulator of angular-control resolution 1 arcsec for payloads weighing up to 500 kg. In addition, two smaller cylindrical chambers, each 0.9 x 1.2 m, are available for vacuum and thermal testing of UV detectors, filters, and space electronics hardware. All three chambers open into class-10,000 clean rooms, and all calibrations are referred to NBS secondary standards.

Welsh, Barry Y.↗

Video Meteor Fluxes

The flux of meteoroids, or number of meteoroids per unit area per unit time, is critical for calibrating models of meteoroid stream formation and for estimating the hazard to spacecraft from shower and sporadic meteors. Although observations of meteors in the millimetre to centimetre size range are common, flux measurements (particularly for sporadic meteors, which make up the majority of meteoroid flux) are less so. It is necessary to know the collecting area and collection time for a given set of observations, and to correct for observing biases and the sensitivity of the system. Previous measurements of sporadic fluxes are summarized in Figure 1; the values are given as a total number of meteoroids striking the earth in one year to a given limiting mass. The Gr n et al. (1985) flux model is included in the figure for reference. Fluxes for sporadic meteoroids impacting the Earth have been calculated for objects in the centimeter size range using Super-Schmidt observations (Hawkins & Upton, 1958); this study used about 300 meteors, and used only the physical area of overlap of the cameras at 90 km to calculate the flux, corrected for angular speed of meteors, since a large angular speed reduces the maximum brightness of the meteor on the film, and radiant elevation, which takes into account the geometric reduction in flux when the meteors are not perpendicular to the horizontal. They bring up corrections for both partial trails (which tends to increase the collecting area) and incomplete overlap at heights other than 90 km (which tends to decrease it) as effects that will affect the flux, but estimated that the two effects cancelled one another. Halliday et al. (1984) calculated the flux of meteorite-dropping fireballs with fragment masses greater than 50 g, over the physical area of sky accessible to the MORP fireball cameras, counting only observations in clear weather. In the micron size range, LDEF measurements of small craters on spacecraft have been used to estimate the flux (Love & Brownlee, 1993); here the physical area of the detector is well known, but the masses depend strongly on the unknown velocity distribution. In the same size range, Thomas & Netherway (1989) used the narrow-beam radar at Jindalee to calculate the flux of sporadics. In between these very large and very small sizes, a number of video and photographic observations were reduced by Ceplecha (2001). These fluxes were calculated (details are given in Ceplecha, 1988) taking the Halliday et al. (1984) MORP fireball fluxes, slightly corrected in mass, as a calibration, and adjusting the flux of small cameras to overlap with the number/mass relation from that work.

Campbell-Brown, M. D.↗

Pressure suit joint analyzer

A measurement system for simultaneously measuring torque and angular flexure in a pressure suit joint is described. One end of a joint under test is held rigid. A torque transducer is pivotably supported on the other movable end of a joint. A potentiometer is attached to the transducer by an arm. The wiper shaft of the potentiometer is gripped by a reference arm that rotates the wiper shaft the same angle as the flexure of joint. A signal is generated by the potentiometer which is representative of the joint flexure. A compensation circuit converts the output of the transducer to a signal representative of joint torque.

Vykukal, H. C.↗

Solar Probe - System concepts and requirements

The design and related constraints relevant to the development of the Solar Probe are examined with reference to the environmental conditions and mission trajectory. The science-related requirements of the Solar Probe mission include instruments with 360-deg sweep on a platform that spins at 60 rpm and carries a magnetometer on a boom. The mission trajectory of a 4-solar-radii perihelion is designed to eliminate angular velocity about the sun, and the unusual requirements of dense interplanetary dust and enhanced gamma-ray radiation are mentioned. A list of specific functional requirements that directly affect the system configuration is given which includes those for the high-gain antenna and the main shield. These requirements are translated into a full-science-scope spacecraft design, and specific mass and power estimates are given. Reduced-scope and baseline configurations are also presented that allow good scientific return with significantly reduced development costs.

Gronroos, H. G.↗

Delimitation of terrestrial impact craters by way of pseudotachylytic rock distribution

The determination of the shape and size of terrestrial impact craters is problematic, yet is critical to understanding cratering mechanics and for scaling bolide mass, volume, and impact velocity with crater size and target response. The problem is particularly difficult in older geological terrains (e.g. Precambrian) which are more likely to have suffered post-impact deformation and hence distortion of the original structure and/or where weathering may have partly removed or obscured its original shape. Traditionally, a number of features are used to assist us in determining the shape and size of an impact structure. These include the following: (1) the occurrence of faults, especially those disposed concentrically relative to the crater--the outermost ring faults being interpreted as indicating a viable minimum diameter; and (2) the development of so-called breccias, some of which are also associated with faults (e.g. the Sudbury Breccia developed within the target rocks of the Sudbury Structure of Onta rio, Canada). 'Breccia' is not a satisfactory term because a number of breccia-types exist at impact sites (e.g. fall-back breccias and in-situ brecciated target material). Of relevance to crater diameter determination is the recognition of discrete zones and fault- and shock-related pseudotachylyte. Pseudotachylyte is a rock type comprising a fine-grained, usually dark matrix containing clasts of minerals and/or rock derived from the country rock target material. It origin is normally attributed to high-speed slip (including vibration) along a slip surface (i.e. fault) or to the passage of a shock wave through the host material. The clasts can occur as angular fragments (i.e. like a breccia), but are more commonly developed as rounded to sub-rounded fragments. Significantly, the scale of these pseudotachylytes can range from sub-millimeter thick veinlets to dyke-like bodies up to 1 km or more thick. It is the latter, larger occurrence which has been referred to as 'breccia.' The smaller-sized occurrence is generally not recognized in the field, nor is it traditionally associated with its larger counterpart.

Spray, John G.↗

Spectral Irradiance Calibration in the Infrared: 3-35 microns Spectra of Three Southern Standard Stars - Part 6

We present three new absolutely calibrated continuous stellar spectra from 3 to 35 microns, constructed as far as possible from actual observed spectral fragments taken from the Kuiper Airborne Observatory (KAO), and the IRAS Low Resolution Spectrometer (LRS). These stars- alpha(sup 1) Cen, alpha TrA, and epsilon Car-augment our previous archive of complete absolutely calibrated spectra for northern K and M giants. All these spectra have a common calibration pedigree. The wavelength coverage is ideal for calibration of many existing and proposed ground-based, airborne, and satellite sensors. KAO and IRAS data in the 15-30 micron range suggest that the spectra of cool giants are close to Rayleigh-Jeans slopes. Our observations of alpha(sup 1) Cen, absolutely calibrated via our adopted Sirius model, indicate an angular diameter in very good agreement with values in the literature, demonstrating 'closure' of the set of spectra within our absolute framework. We compare our observed alpha(sup 1) Cen spectrum with a published grid of theoretical models from Kurucz, and adopt a plausible theoretical shape, that fits our spectrum, as a secondary reference spectrum in the southern sky.

Cohen, Martin↗

As the World Turns: Everything You Wanted to Know about Earth's Rotation

Earth's rotation vector is not a constant in space. Rather, it varies slightly with time on all temporal scales in a very complex, but interesting way. Phenomenologically, the variation can be considered separately in terms of (1) variations in the rotational speed (which translates into the length of day); and (2) variations in the orientation of the rotation axis (called the polar motion relative to the Earth reference frame, and the nutations relative to the inertial space). From the dynamics point of view, these changes can be separated into two types: astronomical (due to external torques mostly exerted by Moon and Sun), and geophysical (due to mass transport in the geophysical fluids of the Earth system under the conservation of angular momentum). Interesting and significant phenomena result. Decades of advancing measurements and active research have yielded fascinating stories.

Chao, Benjamin F.↗

Optical Alignment of the Global Precipitation Measurement (GPM) Star Trackers

The optical alignment of the star trackers on the Global Precipitation Measurement (GPM) core spacecraft at NASA Goddard Space Flight Center (GSFC) was challenging due to the layout and structural design of the GPM Lower Bus Structure (LBS) in which the star trackers are mounted as well as the presence of the star tracker shades that blocked line-of-sight to the primary star tracker optical references. The initial solution was to negotiate minor changes in the original LBS design to allow for the installation of a removable item of ground support equipment (GSE) that could be installed whenever measurements of the star tracker optical references were needed. However, this GSE could only be used to measure secondary optical reference cube faces not used by the star tracker vendor to obtain the relationship information and matrix transformations necessary to determine star tracker alignment. Unfortunately, due to unexpectedly large orthogonality errors between the measured secondary adjacent cube faces and the lack of cube calibration data, we required a method that could be used to measure the same reference cube faces as originally measured by the vendor. We describe an alternative technique to theodolite auto-collimation for measurement of an optical reference mirror pointing direction when normal incidence measurements are not possible. This technique was used to successfully align the GPM star trackers and has been used on a number of other NASA flight projects. We also discuss alignment theory as well as a GSFC-developed theodolite data analysis package used to analyze angular metrology data.

Hetherington, Samuel↗

Uncertainty in Soil Moisture Retrievals: an Ensemble Approach Using SMOS L-Band Microwave Data

The uncertainty of soil moisture (SM) retrievals from satellite brightness temperature (TB) observations depends primarily on the choice of radiative transfer model (RTM) parameters, prior SM information and TB inputs. This paper studies the sensitivity of several (quasi-)operational and experimental SM retrieval products from the Soil Moisture Ocean Salinity (SMOS) mission to these choices at 11 reference sites, located in 7 watersheds across the United States (US). Different literature-based RTM parameter sets cause large biases between retrievals. Whereas typical RTM parameter sets are calibrated for SM retrievals, it is shown that a parameter set carefully optimized for TB forward modeling can also be used for retrieving SM. It is also shown that the inclusion of dynamic prior SM estimates in a Bayesian retrieval scheme can strongly improve SM retrievals, regardless of the choice of RTM parameters, and that the use of multi-angular and multi-polarization TB does not necessarily lead to superior retrievals compared to retrievals based on TB data at a single incidence angle and polarization. The second part of this paper evaluates ensemble uncertainty metrics for SM retrievals obtained by propagating a wide range of RTM parameters through the RTM. As expected for bounded variables, the spread in the ensemble SM retrievals is smallest for wet and dry SM values and highest for intermediate SM values. After removal of the strong long-term mean bias associated with the RTM parameter values for individual ensemble members, the remaining anomaly ensemble SM spread of 0.037 cu m/cu m approximates the actual time series unbiased root-mean-square-difference of 0.042 cu m/cu m between ensemble mean retrievals and in situ reference data across the reference sites. However, the temporal variability in the anomaly ensemble spread reveals higher-order biases in the retrieval error, which should be accounted for when characterizing retrieval error.

Jan Quets↗

Some aversive characteristics of centrifugally generated gravity.

The effective weight of rats was manipulated by centrifugation. Two effective weight levels were obtained. In three escape avoidance conditions a lever press produced a change from a base level of 2.1 g to a response level of 1.1 g. In a punishment condition a response produced a change from a 1.1 g level to a 2.1 g level and in an extinction condition responses had no effect on the 2.1 g effective weight level present. All changes took 30 sec and were maintained for an additional 10 sec before a return to base level was initiated. When responses occurred closer together than the 40 sec, they delayed the return to base level by 40 sec. This 40 sec interval is referred to as response-contingent-time. The response rate and amount of response-contingent-time served as the data. The results confirmed previous data that centrifugation is aversive. The results are interpreted as indicating that the aversiveness is attributable to the increase in effective weight, and that rats can discriminate the different angular velocity-radius of rotation combinations used.

Altman, F.↗

The soft X-ray telescope for the SOLAR-A mission

The Soft X-ray Telescope (SXT) of the SOLAR-A mission is designed to produce X-ray movies of flares with excellent angular and time resolution as well as full-disk X-ray images for general studies. A selection of thin metal filters provide a measure of temperature discrimination and aid in obtaining the wide dynamic range required for solar observing. The co-aligned SXT aspect telescope will yield optical images for aspect reference, white-light flare and sunspot studies, and, possibly, helioseismology. This paper describes the capabilities and characteristics of the SXT for scientific observing.

Tsuneta, S.↗

Output Measurement Equations for Flexible Aircraft Flight Dynamics

A summary of output measurement equations for onboard sensors used in flight testing of flexible aircraft is presented. These equations include the effects of structural flexibility and are considerably more complex than the standard equations for rigid-body aircraft. The output equations discussed include accelerations from linear accelerometers, strains, angular rates, angular accelerations, Euler angles, true airspeed, and air flow angles. The output equations are derived in full form and then simplified in some cases. Linearized output equations, suitable for state-space or transfer function models, are also developed. Example flight test data from the X-56A subscale aeroelastic demonstrator is discussed, for reference.

Grauer, Jared A.↗

Aerodynamic Stability and Performance of Next-Generation Parachutes for Mars Descent

The Low Density Supersonic Decelerator Project is developing a next-generation supersonic parachute for use on future Mars missions. In order to determine the new parachute configuration, a wind tunnel test was conducted at the National Full-scale Aerodynamics Complex 80- by 120-foot Wind Tunnel at the NASA Ames Research Center. The goal of the wind tunnel test was to quantitatively determine the aerodynamic stability and performance of various canopy configurations in order to help select the design to be flown on the Supersonic Flight Dynamics tests. Parachute configurations included the diskgap- band, ringsail, and ringsail-variant designs referred to as a disksail and starsail. During the wind tunnel test, digital cameras captured synchronized image streams of the parachute from three directions. Stereo hotogrammetric processing was performed on the image data to track the position of the vent of the canopy throughout each run. The position data were processed to determine the geometric angular history of the parachute, which were then used to calculate the total angle of attack and its derivatives at each instant in time. Static and dynamic moment coefficients were extracted from these data using a parameter estimation method involving the one-dimensional equation of motion for a rotation of parachute. The coefficients were calculated over all of the available canopy states to reconstruct moment coefficient curves as a function of total angle of attack. From the stability curves, useful metrics such as the trim total angle of attack and pitch stiffness at the trim angle could be determined. These stability metrics were assessed in the context of the parachute's drag load and geometric porosity. While there was generally an inverse relationship between the drag load and the stability of the canopy, the data showed that it was possible to obtain similar stability properties as the disk-gap-band with slightly higher drag loads by appropriately tailoring the geometric porosity distribution.

Low Density Supersonic Decelerator (LDSD)↗

NASA's CLARREO Pathfinder Mission: The Reflected Solar’s First SITSat

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) Pathfinder mission will take reflected solar (RS) highly accurate measurements needed to monitor Earth’s climate and will be the first RS SI-traceable Satellite Sensor (SITSat). The mission includes a RS spectrometer that will be installed on the International Space Station (ISS) and take measurements for at least one year. CLARREO Pathfinder (CPF) will use on-orbit calibration to achieve an unprecedented high accuracy with SI-traceability and the inter-calibration of other on-orbit instruments. The spectrometer is based on the HyperSpectral Imager for Climate Science (HySICS) instrument developed by the University of Colorado/Laboratory for Atmospheric and Space Physics of Boulder, CO, USA. HySICS is being designed to have a radiometric uncertainty of 0.3% (1-sigma), a five to ten times improvement over existing spaceflight RS instruments. High accuracy SI-traceable measurements such as these are critical to develop long-term climate-quality data sets. Additionally, by measuring spectral reflectance with high accuracy the CPF instrument will serve as an on-orbit intercalibration radiometric reference for operational Earth-viewing sensors, such as the Clouds and Earth’s Radiant Energy System (CERES) broadband shortwave instrument and the Visible/Infrared Imaging Radiometer Suite (VIIRS). Two-axis pointing, a spectral range from 350 nm to 2300 nm, and a spectral resolution ≤6 nm enable CPF to provide nearly coincident temporal, spatial, angular, and spectral matching of intercalibration targets, with sampling sufficient to reduce random errors. The intercalibration method will refine knowledge of target sensors’ effective offsets, gain, non-linearity, spectral response, and polarization sensitivity (as is relevant). Calibrated reflectance and reflected radiance spectra will be distributed to the scientific community through a NASA Distributed Active Archive Center (DAAC). We will present an overview of the CLARREO Pathfinder mission, its anticipated impact on monitoring climate variability, and the novel CPF direct intercalibration approach.

climate↗

The Vestibular System and Human Dynamic Space Orientation

The motion sensors of the vestibular system are studied to determine their role in human dynamic space orientation and manual vehicle control. The investigation yielded control models for the sensors, descriptions of the subsystems for eye stabilization, and demonstrations of the effects of motion cues on closed loop manual control. Experiments on the abilities of subjects to perceive a variety of linear motions provided data on the dynamic characteristics of the otoliths, the linear motion sensors. Angular acceleration threshold measurements supplemented knowledge of the semicircular canals, the angular motion sensors. Mathematical models are presented to describe the known control characteristics of the vestibular sensors, relating subjective perception of motion to objective motion of a vehicle. The vestibular system, the neck rotation proprioceptors and the visual system form part of the control system which maintains the eye stationary relative to a target or a reference. The contribution of each of these systems was identified through experiments involving head and body rotations about a vertical axis. Compensatory eye movements in response to neck rotation were demonstrated and their dynamic characteristics described by a lag-lead model. The eye motions attributable to neck rotations and vestibular stimulation obey superposition when both systems are active. Human operator compensatory tracking is investigated in simple vehicle orientation control system with stable and unstable controlled elements. Control of vehicle orientation to a reference is simulated in three modes: visual, motion and combined. Motion cues sensed by the vestibular system through tactile sensation enable the operator to generate more lead compensation than in fixed base simulation with only visual input. The tracking performance of the human in an unstable control system near the limits of controllability is shown to depend heavily upon the rate information provided by the vestibular sensors.

VESTIBULAR APPARATUS↗

Laser Frequency Stabilization

Laser ranging and interferometry are essential technologies allowing for many astounding new spacebased missions such as the Laser Interferometer Space Antenna (LISA) to measure gravitational radiation emitted from distant super massive black hole mergers or distributed aperture telescopes with unprecedented angular resolution in the NIR or visible regime. The requirements on laser frequency noise depend on the residual motion and the distances between the spacecraft forming the interferometer. The intrinsic frequency stability of commercial lasers is several orders of magnitude above these requirements. Therefore, it is necessary for lasers to be stabilized to an ultrastable frequency reference so that they can be used to sense and control distances between spacecraft. Various optical frequency references and frequency stabilization schemes are considered and investigated for the applicability and usefulness for space-based interferometry missions.

Donelan, Darsa↗