Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Adaptive optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Data driven drift correction for complex optical systems

To exploit the thousand-fold increase in spectral brightness of modern light sources, increasingly intricate experiments are being conducted that demand extremely precise beam trajectory. Maintaining the optimal trajectory over several hours of an experiment with the needed precision necessitates active drift control. Here, we outline time varying Bayesian optimization (TVBO) as a data driven approach for robust drift correction, and illustrate its application for a split and delay optical system composed of six crystals and twelve input dimensions. Using numerical simulations, we exhibit the application of TVBO for linear drift, non-smooth temporal drift as well as constrained TVBO for multi-objective control settings, representing real-life operating conditions. This approach can be easily adapted to other X-ray beam conditioning and guidance systems, including multi-crystal monochromators and grazing-incidence mirrors, to maintain sub-micrometer and nanoradian beam stability over the course of an experiment spanning several hours.

Bayesian optimization↗

Adapting confocal Raman microscopy for in situ studies of redox transformations at electrode-electrolyte interfaces

Confocal Raman microscopy was applied to quantify redox species present within the diffusion layer adjacent to an electrode surface under potentiostatic control. A glass microscope coverslip with a thin indium tin oxide (ITO) coating served as both the working electrode and optical window for a microscope-stage mountable spectroelectrochemical cell. A high numerical aperture objective mounted in an inverted microscope frame just below the stage brought excitation radiation through the coverslip window and to a tight focus a few micrometers above the ITO film surface. Species diffusing into the confocal probe volume defined by the excitation beam focus and the collected light region were detected, identified and quantified based on their Raman scattering frequencies and intensities. Here, in measurements that interrogated the interconversion of ferrocyanide and ferricyanide ions as a function of applied voltage, least-squares regression analysis of spectral datasets predicted the formal potential and relative surface concentrations of the ions in good agreement with the expected Nernstian response. Preliminary studies of methyl viologen reduction at an ITO film/Nafion membrane interface were conducted and show the possibility for estimation of mass transport coefficients of redox species within ionic polymer materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Adjoint-optimized nanoscale light extractor for nitrogen-vacancy centers in diamond

Abstract We designed a nanoscale light extractor (NLE) for the efficient outcoupling and beaming of broadband light emitted by shallow, negatively charged nitrogen-vacancy (NV) centers in bulk diamond. The NLE consists of a patterned silicon layer on diamond and requires no etching of the diamond surface. Our design process is based on adjoint optimization using broadband time-domain simulations and yields structures that are inherently robust to positioning and fabrication errors. Our NLE functions like a transmission antenna for the NV center, enhancing the optical power extracted from an NV center positioned 10 nm below the diamond surface by a factor of more than 35, and beaming the light into a ±30° cone in the far field. This approach to light extraction can be readily adapted to other solid-state color centers.

42 ENGINEERING↗

FY 2026 Midyear Report: Seismic Monitoring of Underground Vibration Sources Using Distributed Acoustic Sensing and Seismometers

Safeguards-relevant temporal changes in underground facilities can be observed using geophysical monitoring techniques. Seismic waves, in particular, provide valuable insights into subsurface activities and can serve as an important tool for detecting anomalous events that may indicate containment breaches at geological repositories. This midyear report summarizes ongoing efforts to automatically and rapidly detect and locate anomalous vibration signals that could be indicative of potential containment breaches. Previous work during FY25 focused on compiling continuous seismic datasets from two underground sites and developing a database of continuous waveforms and ground-truth event data derived from multiple sensing modalities. Building on this foundation, we are adapting anomaly detection and geolocation algorithms to explore methods for monitoring underground activities using two relatively low-maintenance sensing technologies: a dense surface geophone array deployed at the Pleasant Gap mine in Pennsylvania, and a three-dimensional fiber-optic cable array for distributed acoustic sensing (DAS) installed in the subsurface at the Sanford Underground Research Facility (SURF) in South Dakota. This report summarizes work conducted during the first two quarters of FY26, during which we refined a dynamic power spectral density (PSD)-based detector, applied it independently to each geophone station, and then combined the per‑station detections with density-based spatial clustering of applications with noise (DBSCAN) to cluster events and produce spatial maps over a nine‑day interval. In addition, we outline plans for a field trial at the Waste Isolation Pilot Plant (WIPP) in New Mexico to compare traditional seismic monitoring approaches with DAS techniques and to evaluate the benefits of combined data analysis. Activities during the past two quarters have included the preparation and submission of a Field Test Plan to WIPP for approval, as well as submission to headquarters for review and feedback.

58 GEOSCIENCES↗

Optical diagnostics of laser-produced plasmas

Laser-produced plasmas (LPPs) engulf exotic and complex conditions ranging in temperature, density, pressure, magnetic and electric fields, charge states, charged particle kinetics, and gas-phase reactions, based on the irradiation conditions, target geometries, and the background cover gas. The application potential of the LPP is so diverse that it generates considerable interest for both basic and applied research areas. The fundamental research on LPPs can be traced back to the early 1960s, immediately after the invention of the laser. In the 1970s, the laser was identified as a tool to pursue inertial confinement fusion, and since then, several other technologies emerged out of LPPs. These applications prompted the development and adaptation of innovative diagnostic tools for understanding the fundamental nature and spatiotemporal properties of these complex systems. Although most of the traditional characterization techniques developed for other plasma sources can be used to characterize the LPPs, care must be taken to interpret the results because of their small size, transient nature, and inhomogeneities. The existence of the large spatiotemporal density and temperature gradients often necessitates non-uniform weighted averaging over distance and time. Among the various plasma characterization tools, optical-based diagnostic tools play a key role in the accurate measurements of LPP parameters. The optical toolbox contains optical spectroscopy (emission, absorption, and fluorescence), passive and active imaging and optical probing methods (shadowgraphy, Schlieren, interferometry, Thomson scattering, deflectometry, and velocimetry). Each technique is useful for measuring a specific property, and its use is limited to a certain time span during the LPP evolution because of the sensitivity issues related to the selected measuring tool. Therefore, multiple diagnostic tools are essential for a comprehensive insight into the entire plasma behavior. In recent times, the improvements in performance in the lasers and detector systems expanded the capability of the aforementioned passive and active diagnostics tools. Furthermore, this review provides an overview of optical diagnostic tools frequently employed for the characterization of the LPPs and emphasizes techniques, associated assumptions, and challenges. Considering most of the industrial and other applications of the LPP belong to low to moderate laser intensities (10 8 – 10 15 Wcm –2 ), this review focuses on diagnostic tools pertaining to this regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integrated photonic molecule Brillouin laser with a high-power sub-100-mHz fundamental linewidth

Photonic integrated lasers with an ultra-low fundamental linewidth and a high output power are important for precision atomic and quantum applications, high-capacity communications, and fiber sensing, yet wafer-scale solutions have remained elusive. Here we report an integrated stimulated Brillouin laser (SBL), based on a photonic molecule coupled resonator design, that achieves a sub-100-mHz fundamental linewidth with greater than 10-mW output power in the C band, fabricated on a 200-mm silicon nitride (Si 3 N 4 ) CMOS-foundry compatible wafer-scale platform. The photonic molecule design is used to suppress the second-order Stokes (S2) emission, allowing the primary lasing mode to increase with the pump power without phase noise feedback from higher Stokes orders. The nested waveguide resonators have a 184 million intrinsic and 92 million loaded Q, over an order of magnitude improvement over prior photonic molecules, enabling precision resonance splitting of 198 MHz at the S2 frequency. We demonstrate S2-suppressed single-mode SBL with a minimum fundamental linewidth of 71±18 mHz, corresponding to a 23±6-mHz 2 /Hz white-frequency-noise floor, over an order of magnitude lower than prior integrated SBLs, with an ∼11-mW output power and 2.3-mW threshold power. The frequency noise reaches the resonator-intrinsic thermo-refractive noise from 2-kHz to 1-MHz offset. The laser phase noise reaches −155 dBc/Hz at 10-MHz offset. The performance of this chip-scale SBL shows promise not only to improve the reliability and reduce size and cost but also to enable new precision experiments that require the high-speed manipulation, control, and interrogation of atoms and qubits. Realization in the silicon nitride ultra-low loss platform is adaptable to a wide range of wavelengths from the visible to infrared and enables integration with other components for systems-on-chip solutions for a wide range of precision scientific and engineering applications including quantum sensing, gravitometers, atom interferometers, precision metrology, optical atomic clocks, and ultra-low noise microwave generation.

Liu, Kaikai (ORCID:0000000213609646)↗

Deterministic fabrication of highly reproducible monochromatic quantum emitters in hexagonal boron nitride

Quantum emitters in hexagonal boron nitride are important room temperature single-photon sources. However, conventional fabrication methods yield quantum emitters with dispersed and inconsistent spectral profiles, limiting their potential for practical quantum applications, which demand reproducible high quality single-photon sources. Here, we report the deterministic creation of highly reproducible monochromatic quantum emitters by applying carbon-ion implantation on freestanding hexagonal boron nitride flakes, while a carbon mask with suitable thickness was adapted to optimize the implantation results. Quantum emitters fabricated using this approach exhibited thermally limited monochromaticity, with an emission center wavelength of 590.7 ± 2.7 nm, a narrow full width at half maximum of 7.1 ± 1.7 nm, an emission rate of 1 MHz without optical engineering, and exceptional stability under ambient conditions. Density functional theory calculations and scanning transmission electron microscopy suggest that these emitters are comprised of boron centered carbon tetramers. This method provides a reliable single-photon source for optical quantum computing and potential future industry-scale applications.

Hua, Muchuan [Argonne National Laboratory (ANL), A↗

Learning the Temporal Effect in Infrared Thermal Videos With Long Short-Term Memory for Quality Prediction in Resistance Spot Welding

With the advances of sensing technology, in-situ infrared thermal videos can be collected from Resistance Spot Welding (RSW) processes. Each video records the formulation process of a weld nugget. The nugget evolution creates a “temporal effect” across the frames, which can be leveraged for real-time, nondestructive evaluation (NDE) of the weld quality. Currently, quality prediction with imaging data mainly focuses on optical feature extraction with Convolutional Neural Network (CNN) but does not make the most of such temporal effect. In this study, pixels corresponding to critical locations on the weld nugget surface are extracted from a video to form multivariate time series (MTS). Multivariate Adaptive Regression Splines (MARS) is used in MTS processing to remove noisy signals related to uninformative frames. A Stacked Long Short-Term Memory (LSTM) model is developed to learn from the processed MTS and then predicts weld nugget size and thickness in real-time NDE. Results from a case study on RSW of Boron steel demonstrates the improvement in prediction accuracy and computational time with the proposed method, as compared to CNN-based weld quality prediction.

Guo, Shenghan↗

Phase noise limited frequency shift impulsive Raman spectroscopy

We introduce a method to enable optical amplification of a coherent Raman spectroscopy signal, which we call radio frequency (RF) Doppler Raman spectroscopy. In this article, we consider the perturbation of a probe pulse in a sample due to an excited Raman vibrational coherence as a generalized Doppler shift, which connects a time-varying optical path length (the product of the propagation length and refractive index, OPL = n ℓ) with an optical frequency shift. Amplification of a Raman signal outside of the focused interaction is enabled by converting the Doppler frequency shift experienced by a laser probe pulse into a periodic timing jitter. This transit time perturbation is detected through the phase of a RF electronic signal measured at a harmonic of the probe pulse train with a method adapted from precision metrology techniques used to measure laser pulse train timing jitter. Measurement of a timing jitter allows access to much lower noise floors than other coherent Raman techniques, and by exploiting the new capability to scale the signal of a coherent Raman spectroscopic signal, this method opens the potential to detect very weak Raman signals that are currently not observable due to limits of illumination intensity imposed by laser damage to the specimen and noise.

47 OTHER INSTRUMENTATION↗

Multifrequency Models of Black Hole Photon Rings from Low-luminosity Accretion Disks

Images of black holes encode both astrophysical and gravitational properties. Detecting highly lensed features in images can differentiate between these two effects. We present an accretion disk emission model coupled to the Adaptive Analytical Ray Tracing (AART) code that allows a fast parameter space exploration of black hole photon ring images produced from synchrotron emission from 10 to 670 GHz. As an application, we systematically study several disk models and compute their total flux density, average radii, and optical depth. The model parameters are chosen around fiducial values calibrated to general relativistic magnetohydrodynamic (GRMHD) simulations and observations of M87*. For the parameter space studied, we characterize the transition between optically thin and thick regimes and the frequency at which the first photon ring is observable. Our results highlight the need for careful definitions of photon ring radius in the image domain, as in certain models the highly lensed photon ring is dimmer than the direct emission at certain angles. We find that at low frequencies the ring radii are set by the electron temperature, while at higher frequencies the magnetic field strength plays a more significant role, demonstrating how multifrequency analysis can also be used to infer plasma parameters. Lastly, we show how our implementation can qualitatively reproduce multifrequency black hole images from GRMHD simulations when adding time variability to our disk model through Gaussian random fields. This approach provides a new method for simulating observations from the Event Horizon Telescope and the proposed Black Hole Explorer space mission.

79 ASTRONOMY AND ASTROPHYSICS↗

Excalibur: A Nonparametric, Hierarchical Wavelength Calibration Method for a Precision Spectrograph

Excalibur is a nonparametric, hierarchical framework for precision wavelength calibration of spectrographs. It is designed with the needs of extreme-precision radial-velocity (EPRV) instruments in mind, which require calibration or stabilization to better than 10{sup −4} pixels. Instruments vary along only a few dominant degrees of freedom, especially EPRV instruments that feature highly stabilized optical systems and detectors. Excalibur takes advantage of this property by using all calibration data to construct a low-dimensional representation of all accessible calibration states for an instrument. Excalibur also takes advantage of laser-frequency combs or etalons, which generate a dense set of stable calibration points. This density permits the use of a nonparametric wavelength solution that can adapt to any instrument or detector oddities better than parametric models, such as a polynomial. We demonstrate the success of this method with data from the Extreme Precision Spectrograph (EXPRES), which uses a laser-frequency comb. When wavelengths are assigned to laser comb lines using excalibur, the rms of the residuals is about one-fifth that of wavelengths assigned using polynomial fits to individual exposures. Radial-velocity measurements of HD 34411 show a reduction in rms scatter over a 10 month time baseline from 1.17 to 1.05 m s{sup −1}.

47 OTHER INSTRUMENTATION↗

Estimation of cutting tool wear using an elastomeric tactile sensor

Machining performance of cutting tools and part quality are affected by the geometric condition of the cutting edge, which is influenced by thermomechanical loads experienced during the process. Tool condition monitoring (TCM) systems provide insight for timely replacement of cutting tools. However, existing TCM systems are expensive and require specialized equipment or sensors, hindering widespread adoption. A novel TCM system is developed herein using an elastomeric tactile sensor. Sensor images of the cutting edge are used to quantify wear using two distinct algorithms. In the first algorithm, the unworn and worn edges are identified based on Canny edge detect. In the second, the unworn edge is identified using edge detection while the region of wear is identified using a relative intensity method. In both cases, the maximum wear width is calculated based on an experimentally determined pixel to-physical distance scale. The TCM system is first used to estimate flank wear on a solid carbide helical end mill before evaluating its robustness by employing it to estimate insert wear of an indexable helical end mill. Measurements are also performed manually using an optical microscope and a high-resolution focus variation microscope for verification. The novel technique estimates flank wear in the solid carbide tool with a high accuracy of 98%. Larger discrepancies are observed for the inserts, however, with overlapping uncertainties. In conclusion, the technique shows promise in adaptability, automation, and closed loop control of machine tools.

Machining↗

Thermobifida fusca Cel6B moves bidirectionally while processively degrading cellulose

Abstract Background Cellulose, an abundant biopolymer, has great potential to be utilized as a renewable fuel feedstock through its enzymatic degradation into soluble sugars followed by sugar fermentation into liquid biofuels. However, crystalline cellulose is highly resistant to hydrolysis, thus industrial-scale production of cellulosic biofuels has been cost-prohibitive to date. Mechanistic studies of enzymes that break down cellulose, called cellulases, are necessary to improve and adapt such biocatalysts for implementation in biofuel production processes. Thermobifida fusca Cel6B ( Tf Cel6B) is a promising candidate for industrial use due to its thermostability and insensitivity to pH changes. However, mechanistic studies probing Tf Cel6B hydrolytic activity have been limited to ensemble-scale measurements. Results We utilized optical tweezers to perform single-molecule, nanometer-scale measurements of enzyme displacement during cellulose hydrolysis by Tf Cel6B. Records featured forward motility on the order of 0.17 nm s −1 interrupted by backward motions and long pauses. Processive run lengths were on the order of 5 nm in both forward and backward directions. Motility records also showed rapid bidirectional displacements greater than 5 nm. Single-enzyme velocity and bulk ensemble activity were assayed on multiple crystalline cellulose allomorphs revealing that the degree of crystallinity and hydrogen bonding have disparate effects on the single-molecule level compared to the bulk scale. Additionally, we isolated and monitored the catalytic domain of Tf Cel6B and observed a reduction in velocity compared to the full-length enzyme that includes the carbohydrate-binding module. Applied force has little impact on enzyme velocity yet it readily facilitates dissociation from cellulose. Preliminary measurements at elevated temperatures indicated enzyme velocity strongly increases with temperature. Conclusions The unexpected motility patterns of Tf Cel6B are likely due to previously unknown mechanisms of processive cellulase motility implicating irregularities in cellulose substrate ultrastructure. While Tf Cel6B is processive, it has low motility at room temperature. Factors that most dramatically impact enzyme velocity are temperature and the presence of its native carbohydrate-binding module and linker. In contrast, substrate ultrastructure and applied force did not greatly impact velocity. These findings motivate further study of Tf Cel6B for its engineering and potential implementation in industrial processes.

Johnson, Madeline M. (ORCID:000000029518293X)↗

A Combined Computer Vision and Deep Learning Approach for Rapid Drone-Based Optical Characterization of Parabolic Troughs

Optical accuracy is a primary driver of parabolic trough concentrating solar power (CSP) plant performance, but can be damaged by wind loads, gravity, error during installation, and regular plant operation. Collecting and analyzing optical measurements over an entire operating parabolic trough plant is difficult, given the large scale of typical installations. Distant Observer, a software tool developed at the National Renewable Energy Laboratory, uses images of the absorber tube reflected in the collector mirror to measure both surface slope in the parabolic mirror and offset of the absorber tube from the ideal focal point. This technology has been adapted for fast data collection using low-cost commercial drones, but until recently still required substantial human labor to process large amounts of data. A new method leveraging advanced deep learning and computer vision tools can drastically reduce the time required to process images. This new method addresses the primary analysis bottleneck, identifying featureless, reflective mirror corner points to a high degree of accuracy. Recent work has shown promising results using computer vision methods. The combined deep learning and computer vision approach presented here proved highly effective and has the potential to further automate data collection and analysis, making the tool more robust. The method presented in this paper automatically identified 74.3% of mirror corners within 2 pixels of their manually marked counterparts and 91.9% within 3 pixels. This level of accuracy is sufficient for practical Distant Observer analysis within a target uncertainty. A commercial drone collected video of over 100 parabolic trough modules at an operating CSP plant to demonstrate the deep learning and computer vision method's usefulness in processing large amounts of data. These troughs were successfully analyzed using Distant Observer, paired with the new deep learning and computer vision algorithm, and can provide plant operators and trough designers with valuable insight about plant performance, operating strategies, and plant-wide optical error trends.

computer vision↗

A mid-scale plasma-electrode Pockels cell for the FLUX laser

A mid-scale (270 x 270-mm aperture) plasma-electrode Pockels cell (PEPC) has been developed for the pump laser system in FLUX (the fourth-generation laser for ultrabroadband experiments). The FLUX mid-scale PEPC is adapted from the PEPC used in the OMEGA EP beamlines (410 x 410-mm aperture), with certain dimensions scaled to reduce capacitance while maintaining key plasma characteristics. After experimental optimization of operating parameters, particularly the plasma current, <70-ns switching time with excellent (>1000:1) contrast has been demonstrated. Dependence of optical switching performance on operating conditions is explained by a plasma model.

AMICA↗

HAMscope: a snapshot Hyperspectral Autofluorescence Miniscope for real-time molecular imaging

We introduce HAMscope, a compact, snapshot hyperspectral autofluorescence miniscope that enables real-time, label-free molecular imaging in a wide range of biological systems. By integrating a thin polymer diffuser into a widefield miniscope, HAMscope spectrally encodes each frame and employs a probabilistic deep learning framework to reconstruct 30-channel hyperspectral stacks (452-703 nm) or directly infer molecular composition maps from single images. A scalable multi-pass U-Net architecture with transformer-based attention and per pixel uncertainty estimation enables high spatio-spectral fidelity (mean absolute error ∼0.0048) at video rates. While initially demonstrated in plant systems, including lignin, chlorophyll, and suberin imaging in intact poplar and cork tissues, the platform is readily adaptable to other applications such as neural activity mapping, metabolic profiling, and histopathology. We show that the system generalizes to out-of-distribution tissue types and supports direct molecular mapping without the need for spectral unmixing. HAMscope establishes a general framework for compact, uncertainty-aware spectral imaging that combines minimal optics with advanced deep learning, offering broad utility for real-time biochemical imaging across neuroscience, environmental monitoring, and biomedicine.

59 BASIC BIOLOGICAL SCIENCES↗

Comparison of temperature adaptive calibration methods for laser induced fluorescence based fuel-in-oil instrument

Fuel dilution of engine oil (or fuel-in-oil, FiO) is an important issue as multiple and late-cycle fuel injection, integral to many combustion efficiency and emissions improvements (e.g., downsized boosted gasoline engines and catalyst thermal management) increases FiO rate. In addition to causing general wear and corrosion in engine due to decreased oil viscosity and pH buffering, FiO is also believed to cause destructive low speed pre-ignition (or super knock) in boosted SI engines. To understand the effects of engine operating conditions on the FiO rate, an optical diagnostic capable of measuring transient FiO on minute timescales was recently developed and demonstrated on a modified GM Ecotech engine system (Neupane et al., Applied Spectroscopy 2021). The measurement is based on adding a dye to the fuel and monitoring for its presence in oil via laser-induced fluorescence (LIF). The measured LIF signal is related to FiO concentration via pre-determined calibration factors using a multivariate classical least square (CLS) method.Since fluorescence quantum yield is a function of temperature, measured LIF intensity not only depends on FiO concentration but also oil temperature. To expand the applicability of the FiO diagnostic to transient oil-temperature conditions (e.g., cold start in practical engines), this study develops a method to account for oil-temperature variations. The effect of oil temperature (20°C - 95°C) on the LIF spectra of eight FiO samples ranging from ~0.8-15% was investigated. LIF intensities of the FiO samples decreased linearly with increasing temperature; the reductions being more significant at dye peaks. We develop a new calibration model (T-adaptive CLS) incorporating the temperature (T) effects on LIF intensity that enables simultaneous calculation of FiO and oil temperature. The improved FiO diagnostic with T-adaptive calibration is more robust, and applicable to varying oil-temperature conditions. For example, when strategies such as multiple/late fuel injections are applied to overcome cold-start instability due to use of low vaporization bio-based fuels such as ethanol, FiO rate is expected to be very high; the improved T-adaptive FiO diagnostic is hence relevant for engine- and fuel-system calibration and optimization. The diagnostic could also provide validation data for flow-field and spray interaction CFD models, further broadening the diagnostic’s utility for advancing engine technology and efficiency.

Neupane, Sneha↗